Shaorong Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shaorong Liu has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
Joann J. Lu
Department of Chemistry and Biochemistry, University of Oklahoma, USA
18 shared publicationsZaifang Zhu
Department of Chemistry and Biochemistry, University of Oklahoma, 101 Stephenson Parkway, Norman, OK 73019, USA; AB Sciex LLC, Brea, CA 92821, USA
16 shared publicationsHuang Chen
Department of Chemistry and Biochemistry , University of Oklahoma , Norman , Oklahoma 73019 , United States
12 shared publicationsYu Yang
Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK, 73019, USA
10 shared publications- Apeng Chen
Department of Respiratory Medicine Children's Hospital of Nanjing Medical University Nanjing China
9 shared publications Kyle B. Lynch
Department of Chemistry and Biochemistry, University of Oklahoma, 101 Stephenson Parkway, Norman, OK, 73019, United States
8 shared publications
Latest Publications
- 6 June 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1673, 463202
Open tubular liquid chromatographic system for using columns with inner diameter of 2 µm. A tutorial
- 6 June 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1673, 463202
Open tubular liquid chromatographic system for using columns with inner diameter of 2 µm. A tutorial
- 1 September 2021
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 142, 116321
Liquid chromatography using ≤5 μm open tubular columns
- 1 September 2021
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 142, 116321
Liquid chromatography using ≤5 μm open tubular columns
- 1 March 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (10) , 4361-4364
Liquid Chromatographic Separation Using a 2 μm i.d. Open Tubular Column at Elevated Temperature
We have experimentally demonstrated the extraordinarily high resolving power of liquid chromatography (LC) using a narrow open tubular (OT) column. In this work, we show that we can further increase its efficiency, peak capacity, and separation speed by elevating the operation (or column) temperature; all of these three numbers can be improved without mutual compromises. We use a mixture of five amino acids as a sample and show that we can increase the efficiency by 34%–260% and the separation speeds by 7%–10% by raising the operation temperature from 30 to 70 °C. When we use a 2 μm i.d. × 80 cm in length OT column coated with OTMS at a temperature of 70 °C, we can frequently obtain peak capacities of 700–800 within 20–30 min for separating cytochrome C digests. By increasing the column length to 160 cm, we can obtain a peak capacity of 2720 within 143 min for separating a complex peptide sample. This peak capacity is the highest peak capacity to date for one-dimensional LC separations. Importantly, heating the column is easy to implement and does not cost much, and many commercial LC systems already have compartments to control column temperatures. Running LC using a narrow OT column at an elevated temperature should broaden the applications of OT-LC in chemical and biochemical analyses.
- 1 March 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (10) , 4361-4364
Liquid Chromatographic Separation Using a 2 μm i.d. Open Tubular Column at Elevated Temperature
We have experimentally demonstrated the extraordinarily high resolving power of liquid chromatography (LC) using a narrow open tubular (OT) column. In this work, we show that we can further increase its efficiency, peak capacity, and separation speed by elevating the operation (or column) temperature; all of these three numbers can be improved without mutual compromises. We use a mixture of five amino acids as a sample and show that we can increase the efficiency by 34%–260% and the separation speeds by 7%–10% by raising the operation temperature from 30 to 70 °C. When we use a 2 μm i.d. × 80 cm in length OT column coated with OTMS at a temperature of 70 °C, we can frequently obtain peak capacities of 700–800 within 20–30 min for separating cytochrome C digests. By increasing the column length to 160 cm, we can obtain a peak capacity of 2720 within 143 min for separating a complex peptide sample. This peak capacity is the highest peak capacity to date for one-dimensional LC separations. Importantly, heating the column is easy to implement and does not cost much, and many commercial LC systems already have compartments to control column temperatures. Running LC using a narrow OT column at an elevated temperature should broaden the applications of OT-LC in chemical and biochemical analyses.
- 25 November 2020
- Published by Wiley in Journal of Separation Science
- Vol. 44 (1) , 274-309
Recent advances and applications of molecularly imprinted polymers in solid‐phase extraction for real sample analysis
Sample pretreatment is essential for the analysis of complicated real samples due to their complex matrices and low analyte concentrations. Among all sample pretreatment methods, solid‐phase extraction is arguably the most frequently used one. However, the majority of available solid‐phase extraction adsorbents suffer from limited selectivity. Molecularly imprinted polymers are a type of tailor‐made artificial antibodies and receptors with specific recognition sites for target molecules. Using molecularly imprinted polymers instead of conventional adsorbents can greatly improve the selectivity of solid‐phase extraction, and therefore molecularly imprinted polymer‐based solid‐phase extraction has been widely applied to separation, clean up and/or preconcentration of target analytes in various kinds of real samples. In this article, after a brief introduction, the recent developments and applications of molecularly imprinted polymer‐based solid‐phase extraction for determination of different analytes in complicated real samples during the 2015‐2020 are reviewed systematically, including the solid‐phase extraction modes, molecularly imprinted adsorbent types and their preparations, and the practical applications of solid‐phase extraction to various real samples (environmental, food, biological, and pharmaceutical samples). Finally, the challenges and opportunities of using molecularly imprinted polymer‐based solid‐phase extraction for real sample analysis are discussed.
- 25 November 2020
- Published by Wiley in Journal of Separation Science
- Vol. 44 (1) , 274-309
Recent advances and applications of molecularly imprinted polymers in solid‐phase extraction for real sample analysis
Sample pretreatment is essential for the analysis of complicated real samples due to their complex matrices and low analyte concentrations. Among all sample pretreatment methods, solid‐phase extraction is arguably the most frequently used one. However, the majority of available solid‐phase extraction adsorbents suffer from limited selectivity. Molecularly imprinted polymers are a type of tailor‐made artificial antibodies and receptors with specific recognition sites for target molecules. Using molecularly imprinted polymers instead of conventional adsorbents can greatly improve the selectivity of solid‐phase extraction, and therefore molecularly imprinted polymer‐based solid‐phase extraction has been widely applied to separation, clean up and/or preconcentration of target analytes in various kinds of real samples. In this article, after a brief introduction, the recent developments and applications of molecularly imprinted polymer‐based solid‐phase extraction for determination of different analytes in complicated real samples during the 2015‐2020 are reviewed systematically, including the solid‐phase extraction modes, molecularly imprinted adsorbent types and their preparations, and the practical applications of solid‐phase extraction to various real samples (environmental, food, biological, and pharmaceutical samples). Finally, the challenges and opportunities of using molecularly imprinted polymer‐based solid‐phase extraction for real sample analysis are discussed.
- 1 May 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1109, 19-26
Performing flow injection chromatography using a narrow open tubular column
- 1 May 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1109, 19-26
Performing flow injection chromatography using a narrow open tubular column
- 27 March 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (7) , 4711-4715
Picoflow Liquid Chromatography–Mass Spectrometry for Ultrasensitive Bottom-Up Proteomics Using 2-μm-i.d. Open Tubular Columns
In many areas of applications key objectives of chemical separations and analysis are to minimize the sample quantity while maximizing the chemical information obtained. Increasing measurement sensitivity is especially critical for proteomics research, especially when processing trace samples and where multiple measurements are desired. A rich collection of technologies has been developed, but the resulting sensitivity remains insufficient for achieving in-depth coverage of proteomic samples as small as single cells. Here we combine picoliter-scale liquid chromatography (picoLC) with mass spectrometry (MS) to address this issue. The picoLC employs 2-µm-i.d. open tubular column to reduce the sample input needed to greatly increase the sensitivity achieved using electrospray ionization (ESI) with MS. With this picoLC-MS system, we show that we can identify ~1000 proteins reliably using only 75 pg of tryptic peptides, representing a 10–100-fold sensitivity improvement compared with the state-of-the-art liquid chromatography (LC) or capillary electrophoresis (CE)-MS methods. PicoLC-MS extends the limit of separation science and is expected to be a powerful tool for single cell proteomics.
- 27 March 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (7) , 4711-4715
Picoflow Liquid Chromatography–Mass Spectrometry for Ultrasensitive Bottom-Up Proteomics Using 2-μm-i.d. Open Tubular Columns
In many areas of applications key objectives of chemical separations and analysis are to minimize the sample quantity while maximizing the chemical information obtained. Increasing measurement sensitivity is especially critical for proteomics research, especially when processing trace samples and where multiple measurements are desired. A rich collection of technologies has been developed, but the resulting sensitivity remains insufficient for achieving in-depth coverage of proteomic samples as small as single cells. Here we combine picoliter-scale liquid chromatography (picoLC) with mass spectrometry (MS) to address this issue. The picoLC employs 2-µm-i.d. open tubular column to reduce the sample input needed to greatly increase the sensitivity achieved using electrospray ionization (ESI) with MS. With this picoLC-MS system, we show that we can identify ~1000 proteins reliably using only 75 pg of tryptic peptides, representing a 10–100-fold sensitivity improvement compared with the state-of-the-art liquid chromatography (LC) or capillary electrophoresis (CE)-MS methods. PicoLC-MS extends the limit of separation science and is expected to be a powerful tool for single cell proteomics.