Omair Inam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Omair Inam has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Hammad Omer
Department of Electrical and Computer Engineering, Medical Image Processing Research Group (MIPRG), COMSATS University Islamabad, Islamabad, Pakistan
8 shared publicationsMahmood Qureshi
Department of Electrical and Computer Engineering, COMSATS University Islamabad, Pakistan
3 shared publications- Mahmood Qureshi
Medical Image Processing Research Group (MIPRG), Department of Electrical & Computer Engineering, COMSATS University Islamabad, Pakistan
3 shared publications - Hammad Omer
Medical Image Processing Research Group (MIPRG), Department of Electrical & Computer Engineering, COMSATS University Islamabad, Pakistan
2 shared publications Ibtisam Aslam
Department of Electrical and Computer Engineering, Medical Image Processing Research Group (MIPRG), COMSATS University Islamabad, Islamabad, Pakistan
2 shared publications- Shahzad Ali Malik
Department of Electrical and Computer Engineering, COMSATS University Islamabad, Islamabad, Pakistan
2 shared publications
Latest Publications
- Open Access
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 178441-178459
GROG Facilitated Compressed Sensing for Radial MRI
ABSTRACT Incoherent k-space sampling plays a critical role in Compressed Sensing MRI (CS-MRI) by facilitating efficient utilization of the limited number of acquired samples to reconstruct high-quality images with reduced acquisition time and improved signal-to-noise ratio. Non-Cartesian sampling like radial, spiral, or randomly sampled trajectories are faster and provide more incoherent k-space compared to Cartesian sampling. However, maintaining the reconstruction quality at high acceleration factors is still challenging with non-Cartesian acquisitions. Addressing these challenges typically involves the use of a GRAPPA operator generated Bunched Phase Encoding data together with a conjugate gradient (CG) reconstruction algorithm, that mimics the functionality of the oscillating gradients required for bunched phase encoding sampling. However, the CG reconstruction method using GROG-generated bunched points is limited to lower acceleration factors ( AF = 2~6). In this paper, a novel CS-based reconstruction framework is proposed leveraging enhanced incoherence along with added redundancy of GROG-generated BPE data, to generate artifact-free images from highly undersampled radial acquisitions. In the proposed framework, GRAPPA operator gridding is applied as a first step, on multi-coil undersampled radial data to generate randomly blipped BPE points. The GROG-generated BPE points (non-Cartesian data) are mapped to the Cartesian grid using self-calibrating GRAPPA operator gridding prior to CS-based image reconstruction. To better understand how the GROG-generated bunched points affect the reconstruction quality, sensitivity maps are not explicitly estimated during the CS reconstruction as a first choice. However, incorporating sensitivity maps of multiple channels helps balance data fidelity and regularization; therefore, the performance of the proposed method using coil sensitivity maps has also been investigated. The proposed methods have been validated with both the simulated and in-vivo multi-coil radial datasets. A comparison between the proposed methods and contemporary CS-based reconstruction methods is performed using quantifying parameters such as Artifact Power, Signal-to-Noise ratio, and Root Mean Square Error. The reconstructed images of the proposed method are also subjectively evaluated by expert radiologists. Experimental results show that the proposed methods yield superior performance, both quantitatively and qualitatively at higher acceleration factors ( upto AF = 14) in comparison with the contemporary CS-based image reconstruction techniques.
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 178441-178459
Open AccessGROG Facilitated Compressed Sensing for Radial MRI
ABSTRACT Incoherent k-space sampling plays a critical role in Compressed Sensing MRI (CS-MRI) by facilitating efficient utilization of the limited number of acquired samples to reconstruct high-quality images with reduced acquisition time and improved signal-to-noise ratio. Non-Cartesian sampling like radial, spiral, or randomly sampled trajectories are faster and provide more incoherent k-space compared to Cartesian sampling. However, maintaining the reconstruction quality at high acceleration factors is still challenging with non-Cartesian acquisitions. Addressing these challenges typically involves the use of a GRAPPA operator generated Bunched Phase Encoding data together with a conjugate gradient (CG) reconstruction algorithm, that mimics the functionality of the oscillating gradients required for bunched phase encoding sampling. However, the CG reconstruction method using GROG-generated bunched points is limited to lower acceleration factors ( AF = 2~6). In this paper, a novel CS-based reconstruction framework is proposed leveraging enhanced incoherence along with added redundancy of GROG-generated BPE data, to generate artifact-free images from highly undersampled radial acquisitions. In the proposed framework, GRAPPA operator gridding is applied as a first step, on multi-coil undersampled radial data to generate randomly blipped BPE points. The GROG-generated BPE points (non-Cartesian data) are mapped to the Cartesian grid using self-calibrating GRAPPA operator gridding prior to CS-based image reconstruction. To better understand how the GROG-generated bunched points affect the reconstruction quality, sensitivity maps are not explicitly estimated during the CS reconstruction as a first choice. However, incorporating sensitivity maps of multiple channels helps balance data fidelity and regularization; therefore, the performance of the proposed method using coil sensitivity maps has also been investigated. The proposed methods have been validated with both the simulated and in-vivo multi-coil radial datasets. A comparison between the proposed methods and contemporary CS-based reconstruction methods is performed using quantifying parameters such as Artifact Power, Signal-to-Noise ratio, and Root Mean Square Error. The reconstructed images of the proposed method are also subjectively evaluated by expert radiologists. Experimental results show that the proposed methods yield superior performance, both quantitatively and qualitatively at higher acceleration factors ( upto AF = 14) in comparison with the contemporary CS-based image reconstruction techniques.
- 4 May 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 160, 107008
Accelerating GRAPPA reconstruction using SoC design for real-time cardiac MRI
- 4 May 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 160, 107008
Accelerating GRAPPA reconstruction using SoC design for real-time cardiac MRI
- 24 February 2022
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 337, 107175
GPU accelerated Cartesian GRAPPA reconstruction using CUDA
- 24 February 2022
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 337, 107175
GPU accelerated Cartesian GRAPPA reconstruction using CUDA
- 1 December 2021
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 333, 107080
Tangent vector-based gradient method with -regularization: Iterative half thresholding algorithm for CS-MRI- 1 December 2021
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 333, 107080
Tangent vector-based gradient method with -regularization: Iterative half thresholding algorithm for CS-MRI- 1 February 2020
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 117, 103598
FPGA-based hardware accelerator for SENSE (a parallel MR image reconstruction method)
- 1 February 2020
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 117, 103598
FPGA-based hardware accelerator for SENSE (a parallel MR image reconstruction method)
- 13 September 2019
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 50 (11) , 1325-1343
De-noising Multi-coil Magnetic Resonance Imaging Using Patch-Based Adaptive Filtering in Wavelet Domain
- 13 September 2019
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 50 (11) , 1325-1343
De-noising Multi-coil Magnetic Resonance Imaging Using Patch-Based Adaptive Filtering in Wavelet Domain
- 4 October 2018
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 50 (1-3) , 243-261
Accelerating Parallel Magnetic Resonance Imaging Using p-Thresholding Based Compressed-Sensing
- 4 October 2018
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 50 (1-3) , 243-261
Accelerating Parallel Magnetic Resonance Imaging Using p-Thresholding Based Compressed-Sensing
- 1 April 2018
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 95, 1-12
QR-decomposition based SENSE reconstruction using parallel architecture
- 1 April 2018
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 95, 1-12
QR-decomposition based SENSE reconstruction using parallel architecture
- Open Access
- 28 September 2017
- Published by Wiley in BioMed Research International
- Vol. 2017, 1-16
Iterative Schemes to Solve Low-Dimensional Calibration Equations in Parallel MR Image Reconstruction with GRAPPA
GRAPPA (Generalized Autocalibrating Partially Parallel Acquisition) is a widely used parallel MRI reconstruction technique. The processing of data from multichannel receiver coils may increase the storage and computational requirements of GRAPPA reconstruction. Random projection on GRAPPA (RP-GRAPPA) uses random projection (RP) method to overcome the computational overheads of solving large linear equations in the calibration phase of GRAPPA, saving reconstruction time. However, RP-GRAPPA compromises the reconstruction accuracy in case of large reductions in the dimensions of calibration equations. In this paper, we present the implementation of GRAPPA reconstruction method using potential iterative solvers to estimate the reconstruction coefficients from the randomly projected calibration equations. Experimental results show that the proposed methods withstand the reconstruction accuracy (visually and quantitatively) against large reductions in the dimension of linear equations, when compared with RP-GRAPPA reconstruction. Particularly, the proposed method using conjugate gradient for least squares (CGLS) demonstrates more savings in the computational time of GRAPPA, without significant loss in the reconstruction accuracy, when compared with RP-GRAPPA. It is also demonstrated that the proposed method using CGLS complements the channel compression method for reducing the computational complexities associated with higher channel count, thereby resulting in additional memory savings and speedup.
- 28 September 2017
- Published by Wiley in BioMed Research International
- Vol. 2017, 1-16
Open AccessIterative Schemes to Solve Low-Dimensional Calibration Equations in Parallel MR Image Reconstruction with GRAPPA
GRAPPA (Generalized Autocalibrating Partially Parallel Acquisition) is a widely used parallel MRI reconstruction technique. The processing of data from multichannel receiver coils may increase the storage and computational requirements of GRAPPA reconstruction. Random projection on GRAPPA (RP-GRAPPA) uses random projection (RP) method to overcome the computational overheads of solving large linear equations in the calibration phase of GRAPPA, saving reconstruction time. However, RP-GRAPPA compromises the reconstruction accuracy in case of large reductions in the dimensions of calibration equations. In this paper, we present the implementation of GRAPPA reconstruction method using potential iterative solvers to estimate the reconstruction coefficients from the randomly projected calibration equations. Experimental results show that the proposed methods withstand the reconstruction accuracy (visually and quantitatively) against large reductions in the dimension of linear equations, when compared with RP-GRAPPA reconstruction. Particularly, the proposed method using conjugate gradient for least squares (CGLS) demonstrates more savings in the computational time of GRAPPA, without significant loss in the reconstruction accuracy, when compared with RP-GRAPPA. It is also demonstrated that the proposed method using CGLS complements the channel compression method for reducing the computational complexities associated with higher channel count, thereby resulting in additional memory savings and speedup.
- 30 August 2017
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 48 (10) , 1055-1074
GPU-Accelerated Self-Calibrating GRAPPA Operator Gridding for Rapid Reconstruction of Non-Cartesian MRI Data
- 30 August 2017
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 48 (10) , 1055-1074
GPU-Accelerated Self-Calibrating GRAPPA Operator Gridding for Rapid Reconstruction of Non-Cartesian MRI Data