Victoria Guerrero-Mestre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Victoria Guerrero-Mestre has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Javier Contreras
E.T.S. de Ingenieros Industriales, University of Castilla–La Mancha 13071 Ciudad Real Spain
5 shared publications- Agustin A. Sanchez de la Nieta
Department of Electrical Engineering, Eindhoven University of Technology (TU/e), Eindhoven, Netherlands
1 shared publication Ahmad Nikoobakht
Department of Electrical and Electronics Engineering Shiraz University of Technology Shiraz Iran
1 shared publication- Andrés Honrubia-Escribano
Renewable Energy Research Institute, Department of Electrical, Electronic, Automatic and Communications Engineering of ETSII-AB, University of Castilla-La Mancha (UCLM), 02071 Albacete, Spain
1 shared publication - Emilio Gómez-Lázaro
Renewable Energy Research Institute, DIEEAC-ETSIIA, Campus Universitario s/n, Universidad de Castilla-La Mancha, 02071 Albacete, Spain
1 shared publication - Jamshid Aghaei
School of Engineering and Technology, Central Queensland University, Rockhampton, QLD, Australia
1 shared publication
Latest Publications
- Open Access
- 5 September 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (18) , 4206-4215
Incorporating energy storage into probabilistic security‐constrained unit commitment
System operators still rely on deterministic criteria such as the (i.e. the system would be able to withstand the outage of any single component without any load shedding) to hedge the system against contingencies. While simple and practical, this criterion miscalculates the actual amount of reserve required since it ignores the probability of contingency occurrence. Therefore, this criterion may lead to suboptimal reserve procurement and economic performance of the system. This study presents a multiperiod probabilistic security‐constrained unit commitment (UC) model that includes the probabilities of generation and transmission contingencies for optimal reserve sizing, sourcing, allocation, and timing. The ability of energy storage systems (ESS) to provide contingency reserve is explicitly modelled. Benders’ decomposition and linearisation techniques are applied to solve the proposed probabilistic UC, which would be intractable otherwise. The impact of ESS on the contingency reserve procurement and deployment in post‐contingency states are analysed on a modified version of the IEEE One‐Area Reliability Test System.
- 5 September 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (18) , 4206-4215
Open AccessIncorporating energy storage into probabilistic security‐constrained unit commitment
System operators still rely on deterministic criteria such as the (i.e. the system would be able to withstand the outage of any single component without any load shedding) to hedge the system against contingencies. While simple and practical, this criterion miscalculates the actual amount of reserve required since it ignores the probability of contingency occurrence. Therefore, this criterion may lead to suboptimal reserve procurement and economic performance of the system. This study presents a multiperiod probabilistic security‐constrained unit commitment (UC) model that includes the probabilities of generation and transmission contingencies for optimal reserve sizing, sourcing, allocation, and timing. The ability of energy storage systems (ESS) to provide contingency reserve is explicitly modelled. Benders’ decomposition and linearisation techniques are applied to solve the proposed probabilistic UC, which would be intractable otherwise. The impact of ESS on the contingency reserve procurement and deployment in post‐contingency states are analysed on a modified version of the IEEE One‐Area Reliability Test System.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Generation Adequacy of the European Electricity System
The idea of a Single Pan-European electricity market has been taking form during the last years and is propitiating deep changes and challenges of the electricity system and the different electricity markets. In order to assess such challenges, several dispatch models have been developed in recent years to study how a single electricity market could work. These models and those to come, will assess the future needs of electricity in Europe. EUPowerDispatch is a minimum-cost dispatch model of the European electricity system which was originally developed to investigate the need for cross-border transmission investment in Europe. This paper proposes an updated version of EUPow-erDispatch that aims at analyzing the generation adequacy of the European electricity system in 2025. For that purpose, planned and unplanned outages of all single conventional generating units are modeled. The former are optimally and timely allocated while the latter are generated with chronological Monte Carlo simulations. Data of wind and PV solar production from several climate years are accounted for as well as hydro series of run-of-river and natural inflows to the hydro reservoirs.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Generation Adequacy of the European Electricity System
The idea of a Single Pan-European electricity market has been taking form during the last years and is propitiating deep changes and challenges of the electricity system and the different electricity markets. In order to assess such challenges, several dispatch models have been developed in recent years to study how a single electricity market could work. These models and those to come, will assess the future needs of electricity in Europe. EUPowerDispatch is a minimum-cost dispatch model of the European electricity system which was originally developed to investigate the need for cross-border transmission investment in Europe. This paper proposes an updated version of EUPow-erDispatch that aims at analyzing the generation adequacy of the European electricity system in 2025. For that purpose, planned and unplanned outages of all single conventional generating units are modeled. The former are optimally and timely allocated while the latter are generated with chronological Monte Carlo simulations. Data of wind and PV solar production from several climate years are accounted for as well as hydro series of run-of-river and natural inflows to the hydro reservoirs.
- Open Access
- 1 January 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (1) , 142-153
Flexible power system operation accommodating uncertain wind power generation using transmission topology control: an improved linearised AC SCUC model
Stochastic security constrained unit commitment (SSCUC) based on a DC model could be problematic in AC networks because the DC model is potentially inaccurate. However, solving SSCUC problems using an AC model is still very challenging. Accordingly, an improved linearised AC optimal power flow (ILACOPF) model is provided in order to optimise the SSCUC problem. The proposed SSCUC model includes a linear representation of network losses and reactive power and bus voltage magnitudes. Moreover, in this study, transmission switching (TS), a powerful tool for grid side flexibility, is introduced and utilised to facilitate the mitigation of the uncertainty of wind power generation. Nevertheless, solving the SSCUC problem with TS in a full AC network is still one of the challenges in practical implementation, which is facilitated by the proposed ILACOPF model. Additionally, the aim of this study is to develop a more accurate power flow model to obtain a more realistic SSCUC solution using TS. The proposed ILAC‐SSCUC model using TS is formulated as a mixed‐integer linear programme, being solved by the proposed effective solution approach based on Benders’ decomposition. Numerical simulations on a 6‐bus and IEEE 118‐bus systems have been performed to evaluate the effectiveness of the method.
- 1 January 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (1) , 142-153
Open AccessFlexible power system operation accommodating uncertain wind power generation using transmission topology control: an improved linearised AC SCUC model
Stochastic security constrained unit commitment (SSCUC) based on a DC model could be problematic in AC networks because the DC model is potentially inaccurate. However, solving SSCUC problems using an AC model is still very challenging. Accordingly, an improved linearised AC optimal power flow (ILACOPF) model is provided in order to optimise the SSCUC problem. The proposed SSCUC model includes a linear representation of network losses and reactive power and bus voltage magnitudes. Moreover, in this study, transmission switching (TS), a powerful tool for grid side flexibility, is introduced and utilised to facilitate the mitigation of the uncertainty of wind power generation. Nevertheless, solving the SSCUC problem with TS in a full AC network is still one of the challenges in practical implementation, which is facilitated by the proposed ILACOPF model. Additionally, the aim of this study is to develop a more accurate power flow model to obtain a more realistic SSCUC solution using TS. The proposed ILAC‐SSCUC model using TS is formulated as a mixed‐integer linear programme, being solved by the proposed effective solution approach based on Benders’ decomposition. Numerical simulations on a 6‐bus and IEEE 118‐bus systems have been performed to evaluate the effectiveness of the method.
- 14 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Stochastic unit commitment considering start-up and shut-down trajectories
The aim of this paper is to provide a formulation of the stochastic unit commitment (UC), modeling in detail the operational phases of the thermal units as well as their start-up and shut-down trajectories. A MILP two-stage stochastic model is proposed for the solution of the proposed UC problem, where the uncertainty considered is related to the wind power penetration and the demand consumption. With this formulation, the thermal units can follow the changes in the wind power generation and the demand more accurately.
- 14 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Stochastic unit commitment considering start-up and shut-down trajectories
The aim of this paper is to provide a formulation of the stochastic unit commitment (UC), modeling in detail the operational phases of the thermal units as well as their start-up and shut-down trajectories. A MILP two-stage stochastic model is proposed for the solution of the proposed UC problem, where the uncertainty considered is related to the wind power penetration and the demand consumption. With this formulation, the thermal units can follow the changes in the wind power generation and the demand more accurately.
- 25 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 31 (4) , 2688-2700
Optimal Bidding of a Group of Wind Farms in Day-Ahead Markets Through an External Agent
In deregulated electricity markets, producers offer their energy to the day-ahead market. As the subsidies for renewable producers are becoming lower and lower, they have to adapt to market prices. This paper models the energy trading in the day-ahead market for wind power producers. Different strategies are proposed for this purpose: 1) several wind farms offering their energy separately to the day-ahead market; 2) the same strategy as in 1) but compensating the imbalance among different wind farms; and 3) a joint offer involving several wind farms through an external agent in order to minimize the imbalances between the offer and the final power generation. The strategies are modeled with stochastic mixed integer linear programming and Conditional Value at Risk is used to consider the risk assessment. The expected profit including risk aversion is maximized for each wind power producer and for the set of wind power producers in the case of a joint offer. A comparison of the different cases is described in detail in a case study and relevant conclusions are provided.
- 25 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 31 (4) , 2688-2700
Optimal Bidding of a Group of Wind Farms in Day-Ahead Markets Through an External Agent
In deregulated electricity markets, producers offer their energy to the day-ahead market. As the subsidies for renewable producers are becoming lower and lower, they have to adapt to market prices. This paper models the energy trading in the day-ahead market for wind power producers. Different strategies are proposed for this purpose: 1) several wind farms offering their energy separately to the day-ahead market; 2) the same strategy as in 1) but compensating the imbalance among different wind farms; and 3) a joint offer involving several wind farms through an external agent in order to minimize the imbalances between the offer and the final power generation. The strategies are modeled with stochastic mixed integer linear programming and Conditional Value at Risk is used to consider the risk assessment. The expected profit including risk aversion is maximized for each wind power producer and for the set of wind power producers in the case of a joint offer. A comparison of the different cases is described in detail in a case study and relevant conclusions are provided.
- 9 December 2014
- Published by Springer Nature
- p. 55-70
Wind Power Forecast Error Probabilistic Model Using Markov Chains
- 9 December 2014
- Published by Springer Nature
- p. 55-70
Wind Power Forecast Error Probabilistic Model Using Markov Chains