Hyun-Woo Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hyun-Woo Lee has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Du-Hyeong Lee
Department of Prosthodontics, University of Iowa College of Dentistry and Dental Clinics, Iowa City, USA
2 shared publications - Baek-Soo Lee
Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyung Hee University, Seoul, Korea
1 shared publication - Bo-Yeon Hwang
Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyung Hee University, Seoul 02447, Korea
1 shared publication - Byung-Joon Choi
Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyung Hee University, Seoul, Korea
1 shared publication - Cheong-Hee Lee
Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
1 shared publication - Cheong-Hee Lee
Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu 41940, Korea
1 shared publication
Latest Publications
- Open Access
- 31 December 2023
- Published by The Korean Association of Oral and Maxillofacial Surgeons in Journal of the Korean Association of Oral and Maxillofacial Surgeons
- Vol. 49 (6) , 347-353
Implant placement with inferior alveolar nerve repositioning in the posterior mandible
Doogyum Kim, Taeil Lim, Hyun-Woo Lee, Baek-Soo Lee, Byung-Joon Choi, Joo Young Ohe, Junho Jung. JKAOMS 2023;49:347-53. https://doi.org/10.5125/jkaoms.2023.49.6.347
- 31 December 2023
- Published by The Korean Association of Oral and Maxillofacial Surgeons in Journal of the Korean Association of Oral and Maxillofacial Surgeons
- Vol. 49 (6) , 347-353
Open AccessImplant placement with inferior alveolar nerve repositioning in the posterior mandible
Doogyum Kim, Taeil Lim, Hyun-Woo Lee, Baek-Soo Lee, Byung-Joon Choi, Joo Young Ohe, Junho Jung. JKAOMS 2023;49:347-53. https://doi.org/10.5125/jkaoms.2023.49.6.347
- Open Access
- 1 January 2023
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 15 (1) , 1-10
Three-dimensional morphometric analysis of facial units in virtual smiling facial images with different smile expressions
Mai HN, et al. J Adv Prosthodont. 2023 Feb;15(1):1-10. https://doi.org/10.4047/jap.2023.15.1.1
- 1 January 2023
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 15 (1) , 1-10
Open AccessThree-dimensional morphometric analysis of facial units in virtual smiling facial images with different smile expressions
Mai HN, et al. J Adv Prosthodont. 2023 Feb;15(1):1-10. https://doi.org/10.4047/jap.2023.15.1.1
- Open Access
Reliability of Metal 3D Printing with Respect to the Marginal Fit of Fixed Dental Prostheses: A Systematic Review and Meta-Analysis
Three-dimensional (3D) printing technologies have been widely used to manufacture crowns and frameworks for fixed dental prostheses. This systematic review and meta-analysis aimed to assess the reliability of the marginal fit of 3D-printed cobalt-chromium-based fixed dental prostheses in comparison to conventional casting methods. Articles published until 25 June 2020, reporting the marginal fit of fixed prostheses fabricated with metal 3D printing, were searched using electronic literature databases. After the screening and quality assessment, 21 eligible peer-reviewed articles were selected. Meta-analysis revealed that the marginal gap of the prostheses manufactured using 3D printing was significantly smaller compared to that manufactured using casting methods (standard mean difference (95% CI): −0.92 (−1.45, −0.38); Z = −3.37; p = 0.0008). The estimated difference between the single and multi-unit types did not differ significantly (p = 0.3573). In the subgroup analysis for the measurement methods, the tendency of marginal discrepancy between the 3D printing and casting groups was significantly different between articles that used direct observation and those that used the silicone replica technique (p < 0.001). Metal 3D printing technologies appear reliable as an alternative to casting methods in terms of the fit of the fixed dental prostheses. In order to analyze the factors influencing manufacturing and confirm the results of this review, further controlled laboratory and clinical studies are required.
Open AccessReliability of Metal 3D Printing with Respect to the Marginal Fit of Fixed Dental Prostheses: A Systematic Review and Meta-Analysis
Three-dimensional (3D) printing technologies have been widely used to manufacture crowns and frameworks for fixed dental prostheses. This systematic review and meta-analysis aimed to assess the reliability of the marginal fit of 3D-printed cobalt-chromium-based fixed dental prostheses in comparison to conventional casting methods. Articles published until 25 June 2020, reporting the marginal fit of fixed prostheses fabricated with metal 3D printing, were searched using electronic literature databases. After the screening and quality assessment, 21 eligible peer-reviewed articles were selected. Meta-analysis revealed that the marginal gap of the prostheses manufactured using 3D printing was significantly smaller compared to that manufactured using casting methods (standard mean difference (95% CI): −0.92 (−1.45, −0.38); Z = −3.37; p = 0.0008). The estimated difference between the single and multi-unit types did not differ significantly (p = 0.3573). In the subgroup analysis for the measurement methods, the tendency of marginal discrepancy between the 3D printing and casting groups was significantly different between articles that used direct observation and those that used the silicone replica technique (p < 0.001). Metal 3D printing technologies appear reliable as an alternative to casting methods in terms of the fit of the fixed dental prostheses. In order to analyze the factors influencing manufacturing and confirm the results of this review, further controlled laboratory and clinical studies are required.
- Open Access
- 3 September 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (17) , 6141
Easy, Fast, and Accurate Method of 3-Dimensional Mirror Plane Creation for Actual Clinical Users
The first thing to do before planning the surgical treatment of unilateral defects or the asymmetry of the facial area is probably establishing adequate mid-plane for comparison and analysis of the normal and affected side. In such cases, a mirror image can be useful to obtain customized and optimized mid-plane for specific individuals considering the degree of the defect and asymmetry. With the concept of the iterative closest point (ICP) algorithm, the surface-based registration of the initial structure and mirrored structure allow us to generate a mirror plane that bisects the mid planes of each structure. This mirror plane would improve the quality of pre-operative evaluation and provide an appropriate start point for the treatment plan with as few errors as possible. Hence, the aim of this article is to introduce a method to create a mirror plane that can be assisting in increasing the accuracy of evaluation and analysis so a precise treatment plan would follow consequently.
- 3 September 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (17) , 6141
Open AccessEasy, Fast, and Accurate Method of 3-Dimensional Mirror Plane Creation for Actual Clinical Users
The first thing to do before planning the surgical treatment of unilateral defects or the asymmetry of the facial area is probably establishing adequate mid-plane for comparison and analysis of the normal and affected side. In such cases, a mirror image can be useful to obtain customized and optimized mid-plane for specific individuals considering the degree of the defect and asymmetry. With the concept of the iterative closest point (ICP) algorithm, the surface-based registration of the initial structure and mirrored structure allow us to generate a mirror plane that bisects the mid planes of each structure. This mirror plane would improve the quality of pre-operative evaluation and provide an appropriate start point for the treatment plan with as few errors as possible. Hence, the aim of this article is to introduce a method to create a mirror plane that can be assisting in increasing the accuracy of evaluation and analysis so a precise treatment plan would follow consequently.
- Open Access
- 1 January 2015
- Published by The Korean Association of Oral and Maxillofacial Surgeons in Journal of the Korean Association of Oral and Maxillofacial Surgeons
- Vol. 41 (2) , 97-101
Salvage rapid maxillary expansion for the relapse of maxillary transverse expansion after Le Fort I with parasagittal osteotomy
Lee HW, et al. J Korean Assoc Oral Maxillofac Surg. 2015 Apr;41(2):97-101. http://dx.doi.org/10.5125/jkaoms.2015.41.2.97
- 1 January 2015
- Published by The Korean Association of Oral and Maxillofacial Surgeons in Journal of the Korean Association of Oral and Maxillofacial Surgeons
- Vol. 41 (2) , 97-101
Open AccessSalvage rapid maxillary expansion for the relapse of maxillary transverse expansion after Le Fort I with parasagittal osteotomy
Lee HW, et al. J Korean Assoc Oral Maxillofac Surg. 2015 Apr;41(2):97-101. http://dx.doi.org/10.5125/jkaoms.2015.41.2.97