Eunae Cho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eunae Cho has a total of 147 co-authors. Here are the top co-authors by number of shared publications:
- Chang-Hwan Park
Department of Internal Medicine, Chonnam National University Medical School, Gwangju, Korea
8 shared publications - Seong Hun Kim
Department of Internal Medicine Research Institute of Clinical Medicine Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital Jeonju Korea
7 shared publications Chang Hwan Park
Department of Internal Medicine, Chonnam National University Medical School Chonnam National University Hospital Gwangju South Korea
6 shared publications- Se Woo Park
Division of Gastroenterology, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Korea
5 shared publications - Seon-Young Park
Department of Internal Medicine, Chonnam National University Medical School, Gwangju 501757, Republic of Korea
3 shared publications - Byeong Jun Song
Department of Internal Medicine, Myongji Hospital, Goyang, Republic of Korea
2 shared publications
Latest Publications
- 17 November 2026
- Published by Wiley in Digestive Endoscopy
- Vol. 38 (11)
EUS ‐Guided Drainage of Postoperative Fluid Collections: A Multicenter Comparison of Plastic Stents, SEMS , and LAMS
Objectives: Postoperative fluid collection (POFC) can lead to significant morbidity if not managed effectively. Endoscopic ultrasound (EUS)‐guided drainage has become a preferred minimally invasive approach, yet the optimal stent type remains uncertain. Thus, this study aimed to evaluate clinical outcomes by stent type. Methods: This multicenter retrospective study evaluated patients with POFCs who underwent EUS‐guided drainage between January 2010 and June 2024. The primary outcome was clinical success according to stent types. Secondary outcomes included adverse events, recurrence, and predictors of clinical failure. Results: Seventy patients underwent EUS‐guided drainage using plastic stents ( n = 20), SEMS ( n = 30), or LAMS ( n = 20). Index surgeries included pancreaticoduodenectomy (37.1%) and distal or subtotal pancreatectomy (52.9%). Early drainage (≤ 28 days) was performed in 70% of cases. Overall clinical success was 87.1%. Clinical success did not differ among stent types (plastic: 80%, SEMS: 90%, LAMS: 90%; p = 0.66), drainage timing (87.8% vs. 85.7%; p = 1.00), or surgery type (84.6% vs. 89.2%; p = 0.71). Adverse events occurred in 11.4% of patients, without a significant difference among the stent groups. No factor was significantly associated with clinical failure. Conclusions: EUS‐guided drainage for POFC demonstrated high clinical success with a low adverse event rate. No statistically significant difference in clinical outcomes was detected across stent types. However, this comparative finding should be regarded as exploratory and requires confirmation in larger prospective studies. Until robust evidence becomes available, stent selection may reasonably be individualized according to the procedural preference and clinical scenario.
- 17 November 2026
- Published by Wiley in Digestive Endoscopy
- Vol. 38 (11)
EUS ‐Guided Drainage of Postoperative Fluid Collections: A Multicenter Comparison of Plastic Stents, SEMS , and LAMS
Objectives: Postoperative fluid collection (POFC) can lead to significant morbidity if not managed effectively. Endoscopic ultrasound (EUS)‐guided drainage has become a preferred minimally invasive approach, yet the optimal stent type remains uncertain. Thus, this study aimed to evaluate clinical outcomes by stent type. Methods: This multicenter retrospective study evaluated patients with POFCs who underwent EUS‐guided drainage between January 2010 and June 2024. The primary outcome was clinical success according to stent types. Secondary outcomes included adverse events, recurrence, and predictors of clinical failure. Results: Seventy patients underwent EUS‐guided drainage using plastic stents ( n = 20), SEMS ( n = 30), or LAMS ( n = 20). Index surgeries included pancreaticoduodenectomy (37.1%) and distal or subtotal pancreatectomy (52.9%). Early drainage (≤ 28 days) was performed in 70% of cases. Overall clinical success was 87.1%. Clinical success did not differ among stent types (plastic: 80%, SEMS: 90%, LAMS: 90%; p = 0.66), drainage timing (87.8% vs. 85.7%; p = 1.00), or surgery type (84.6% vs. 89.2%; p = 0.71). Adverse events occurred in 11.4% of patients, without a significant difference among the stent groups. No factor was significantly associated with clinical failure. Conclusions: EUS‐guided drainage for POFC demonstrated high clinical success with a low adverse event rate. No statistically significant difference in clinical outcomes was detected across stent types. However, this comparative finding should be regarded as exploratory and requires confirmation in larger prospective studies. Until robust evidence becomes available, stent selection may reasonably be individualized according to the procedural preference and clinical scenario.
- Open Access
- 25 October 2026
- Published by The Korean Society of Gastroenterology in The Korean Journal of Gastroenterology
- Vol. 86 (4) , 468-476
Extensive Arterial Thrombosis Complicating Acute Pancreatitis: A Case Report and Literature Review
Min-Seok Cho, Eunae Cho, Hyung-Hoon Oh, and Chang Hwan Park. Korean J Gastroenterol 2026;86:468-76. https://doi.org/10.4166/kjg.2026.035
- 25 October 2026
- Published by The Korean Society of Gastroenterology in The Korean Journal of Gastroenterology
- Vol. 86 (4) , 468-476
Open AccessExtensive Arterial Thrombosis Complicating Acute Pancreatitis: A Case Report and Literature Review
Min-Seok Cho, Eunae Cho, Hyung-Hoon Oh, and Chang Hwan Park. Korean J Gastroenterol 2026;86:468-76. https://doi.org/10.4166/kjg.2026.035
- 20 September 2026
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 41 (11) , 3385-3392
Heparin Wet Suction Versus Conventional Suction in Endoscopic Ultrasound–Guided Fine‐Needle Biopsy for Solid Pancreatic Masses: A Multicenter Randomized Crossover Study
Background and Aim: The heparin wet suction technique (HWST) may improve tissue quality in endoscopic ultrasound–guided fine‐needle biopsy (EUS‐FNB) by preventing blood clot formation within the needle. We compared the diagnostic performance and safety of HWST with the conventional suction technique (CST), using a novel 22‐gauge FNB needle in patients with solid pancreatic masses. Methods: In this multicenter, single‐blinded, randomized crossover trial, patients with solid pancreatic masses (≥ 1 cm) were randomized 1:1 to HWST‐first or CST‐first. Each patient underwent one pass with each technique using the novel 22‐gauge needle. The primary outcome was diagnostic yield; secondary outcomes included technical success, adverse events, and adequacy for immunohistochemistry (IHC). Results: Of 174 randomized patients, 170 received both interventions and were analyzed; baseline characteristics were comparable. The diagnostic yield was 82.9% (95% confidence interval [CI], 76.6–87.9) with HWST and 83.5% (95% CI, 77.2–88.4) with CST. The paired difference was −0.6 percentage points (95% CI, −6.7 to 5.5; exact McNemar p = 1.000). The combined diagnostic yield after sequential sampling was 91.2% (95% CI, 86.0–94.6). Technical success was 100% with both techniques, and IHC adequacy was similar (HWST: 80.6% vs. CST: 78.8%). One self‐limiting bleeding event occurred during CST. Conclusions: HWST showed diagnostic yield, technical success, and safety comparable to CST. Both techniques are highly effective for EUS‐FNB of solid pancreatic masses. Sequential sampling may improve overall diagnostic yield, although this finding should be interpreted cautiously and requires further validation.
- 20 September 2026
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 41 (11) , 3385-3392
Heparin Wet Suction Versus Conventional Suction in Endoscopic Ultrasound–Guided Fine‐Needle Biopsy for Solid Pancreatic Masses: A Multicenter Randomized Crossover Study
Background and Aim: The heparin wet suction technique (HWST) may improve tissue quality in endoscopic ultrasound–guided fine‐needle biopsy (EUS‐FNB) by preventing blood clot formation within the needle. We compared the diagnostic performance and safety of HWST with the conventional suction technique (CST), using a novel 22‐gauge FNB needle in patients with solid pancreatic masses. Methods: In this multicenter, single‐blinded, randomized crossover trial, patients with solid pancreatic masses (≥ 1 cm) were randomized 1:1 to HWST‐first or CST‐first. Each patient underwent one pass with each technique using the novel 22‐gauge needle. The primary outcome was diagnostic yield; secondary outcomes included technical success, adverse events, and adequacy for immunohistochemistry (IHC). Results: Of 174 randomized patients, 170 received both interventions and were analyzed; baseline characteristics were comparable. The diagnostic yield was 82.9% (95% confidence interval [CI], 76.6–87.9) with HWST and 83.5% (95% CI, 77.2–88.4) with CST. The paired difference was −0.6 percentage points (95% CI, −6.7 to 5.5; exact McNemar p = 1.000). The combined diagnostic yield after sequential sampling was 91.2% (95% CI, 86.0–94.6). Technical success was 100% with both techniques, and IHC adequacy was similar (HWST: 80.6% vs. CST: 78.8%). One self‐limiting bleeding event occurred during CST. Conclusions: HWST showed diagnostic yield, technical success, and safety comparable to CST. Both techniques are highly effective for EUS‐FNB of solid pancreatic masses. Sequential sampling may improve overall diagnostic yield, although this finding should be interpreted cautiously and requires further validation.
- Open Access
- 19 August 2026
- Published by The Editorial Office of Gut and Liver in Gut and Liver
- Vol. 20 (6) , 1067-1068
Comments on Creation of a Durable Conduit with a Novel Self-Expandable Metal Stent for Stone Extraction in Endoscopic Retrograde Cholangiopancreatography: A Pilot Study: Reply
Eunae Cho, Chang Hwan Park. Gut and Liver -0001;0:. https://doi.org/10.5009/gnl260169
- 19 August 2026
- Published by The Editorial Office of Gut and Liver in Gut and Liver
- Vol. 20 (6) , 1067-1068
Open AccessComments on Creation of a Durable Conduit with a Novel Self-Expandable Metal Stent for Stone Extraction in Endoscopic Retrograde Cholangiopancreatography: A Pilot Study: Reply
Eunae Cho, Chang Hwan Park. Gut and Liver -0001;0:. https://doi.org/10.5009/gnl260169
- Open Access
- 30 May 2026
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 59 (3) , 403-405
Peripheral vascular rim on endoscopic ultrasound as a practical rule-in sign for pancreatic neuroendocrine neoplasms
Peripheral vascular rim on endoscopic ultrasound as a practical rule-in sign for pancreatic neuroendocrine neoplasms
- 30 May 2026
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 59 (3) , 403-405
Open AccessPeripheral vascular rim on endoscopic ultrasound as a practical rule-in sign for pancreatic neuroendocrine neoplasms
Peripheral vascular rim on endoscopic ultrasound as a practical rule-in sign for pancreatic neuroendocrine neoplasms
- 28 April 2026
- Published by Elsevier in Endocrine Practice
- Vol. 32 (9) , 1369-1377
Incidence and Predictors of Acute Pancreatitis in Patients With Diabetic Ketoacidosis (DKA) and Hyperosmolar Hyperglycemic State (HHS): A Multicenter Retrospective Study
- 28 April 2026
- Published by Elsevier in Endocrine Practice
- Vol. 32 (9) , 1369-1377
Incidence and Predictors of Acute Pancreatitis in Patients With Diabetic Ketoacidosis (DKA) and Hyperosmolar Hyperglycemic State (HHS): A Multicenter Retrospective Study
- Open Access
- 31 January 2026
- Published by Korean Pancreatobiliary Association in The Korean Journal of Pancreas and Biliary Tract
- Vol. 31 (1) , 30-32
Comparison of Safety and Efficacy of In-Stent Radiofrequency Ablation with Uncovered Metal Stent Placement in Patients with Distal Malignant Biliary Obstruction
Comparison of Safety and Efficacy of In-Stent Radiofrequency Ablation with Uncovered Metal Stent Placement in Patients with Distal Malignant Biliary Obstruction
- 31 January 2026
- Published by Korean Pancreatobiliary Association in The Korean Journal of Pancreas and Biliary Tract
- Vol. 31 (1) , 30-32
Open AccessComparison of Safety and Efficacy of In-Stent Radiofrequency Ablation with Uncovered Metal Stent Placement in Patients with Distal Malignant Biliary Obstruction
Comparison of Safety and Efficacy of In-Stent Radiofrequency Ablation with Uncovered Metal Stent Placement in Patients with Distal Malignant Biliary Obstruction
- Open Access
- 15 November 2025
- Published by The Editorial Office of Gut and Liver in Gut and Liver
- Vol. 20 (6) , 1055-1061
Creation of a Durable Conduit with a Novel Self-Expandable Metal Stent for Stone Extraction in Endoscopic Retrograde Cholangiopancreatography: A Pilot Study
Eunae Cho, Chang Hwan Park. Gut and Liver -0001;0:. https://doi.org/10.5009/gnl250355
- 15 November 2025
- Published by The Editorial Office of Gut and Liver in Gut and Liver
- Vol. 20 (6) , 1055-1061
Open AccessCreation of a Durable Conduit with a Novel Self-Expandable Metal Stent for Stone Extraction in Endoscopic Retrograde Cholangiopancreatography: A Pilot Study
Eunae Cho, Chang Hwan Park. Gut and Liver -0001;0:. https://doi.org/10.5009/gnl250355
- Open Access
- 21 August 2025
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 58 (5) , 779-781
The polyp puzzle: multiple lesions, one diagnosis
The polyp puzzle: multiple lesions, one diagnosis
- 21 August 2025
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 58 (5) , 779-781
Open AccessThe polyp puzzle: multiple lesions, one diagnosis
The polyp puzzle: multiple lesions, one diagnosis