Anju Dubey
Research Subjects
Research Interests
Anju Dubey has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Atul Sonker
Department of Transfusion Medicine, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
17 shared publicationsRajendra Chaudhary
Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
5 shared publications- Atul Sonker
Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India
3 shared publications - Rajendra Chaudhary
Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India
3 shared publications RajendraK Chaudhary
Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
2 shared publicationsYatendra Mohan
Department of Transfusion Medicine, S.N. Medical College, Agra, Uttar Pradesh, India
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by Wolters Kluwer Health in Asian Journal of Transfusion Science
- Vol. 19 (1) , 11-16
Evaluation of knowledge, attitude, and response regarding transfusion-transmitted infections in blood donors sero-reactive for viral markers during postdonation counselling as an attempt to identify and bridge the gaps in the blood donation process
BACKGROUND: Donor notification and counseling have been mandated by the Indian action plan for blood safety to facilitate the early diagnosis and subsequent management of sero-reactive blood donors as well as to prevent the spread of infection through subsequent blood donations. This retrospective and questionnaire-based study was conducted with the aim of understanding the level of knowledge, difference in attitudes, and pattern of responses of sero-reactive blood donors which could aid in designing of clear and unambiguous donor educational program as well as enhance the effectiveness of donor selection procedures. Furthermore, the rates of donors’ response to notification and compliance to clinical referral were assessed to find the areas which require improvement. METHODS: Blood donors sero-reactive for viral markers were notified and subjected to postdonation counselling and were asked questions to assess their knowledge, attitude, and response. Retrospective analysis of data of 5 years was done. Donors were followed up by enquiring their status 6 months’ postreferral. RESULTS: Of the 1991 repeat reactive blood donors, 1256 (63.08%) responded for counseling and referral. Long distance and busy schedule were the most common reasons for nonresponse. Lack of privacy and lack of understanding were the main reason for nondisclosure of pertinent information by blood donors. On follow–up, 634 (50.48%) of those counseled actually visited the prescribed referral center. CONCLUSION: Donor counseling should be done by a trained counselor ensuring an understanding of the importance of transfusion-transmitted infection transmission. Donors should be informed about high-risk behavior and self-exclusion should be facilitated.
- 1 January 2025
- Published by Wolters Kluwer Health in Asian Journal of Transfusion Science
- Vol. 19 (1) , 11-16
Open AccessEvaluation of knowledge, attitude, and response regarding transfusion-transmitted infections in blood donors sero-reactive for viral markers during postdonation counselling as an attempt to identify and bridge the gaps in the blood donation process
BACKGROUND: Donor notification and counseling have been mandated by the Indian action plan for blood safety to facilitate the early diagnosis and subsequent management of sero-reactive blood donors as well as to prevent the spread of infection through subsequent blood donations. This retrospective and questionnaire-based study was conducted with the aim of understanding the level of knowledge, difference in attitudes, and pattern of responses of sero-reactive blood donors which could aid in designing of clear and unambiguous donor educational program as well as enhance the effectiveness of donor selection procedures. Furthermore, the rates of donors’ response to notification and compliance to clinical referral were assessed to find the areas which require improvement. METHODS: Blood donors sero-reactive for viral markers were notified and subjected to postdonation counselling and were asked questions to assess their knowledge, attitude, and response. Retrospective analysis of data of 5 years was done. Donors were followed up by enquiring their status 6 months’ postreferral. RESULTS: Of the 1991 repeat reactive blood donors, 1256 (63.08%) responded for counseling and referral. Long distance and busy schedule were the most common reasons for nonresponse. Lack of privacy and lack of understanding were the main reason for nondisclosure of pertinent information by blood donors. On follow–up, 634 (50.48%) of those counseled actually visited the prescribed referral center. CONCLUSION: Donor counseling should be done by a trained counselor ensuring an understanding of the importance of transfusion-transmitted infection transmission. Donors should be informed about high-risk behavior and self-exclusion should be facilitated.
- Open Access
- 1 January 2024
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 18 (1) , 56-61
Molecular typing of Kell, Kidd, and Duffy antigens in direct antiglobulin test-positive autoimmune hemolytic anemia patients
BACKGROUND: In autoimmune hemolytic anemia (AIHA) patients, conventional pretransfusion testing is difficult to interpret due to the presence of autoantibodies which may show panreactivity. Molecular phenotyping of red cell antigens could potentially be used to precisely match blood units, thereby reducing the need to perform intensive serologic laboratory testing, hence time delay in providing transfusion to such patients. The aim of this study is to perform the molecular typing for Kell, Kidd, and Duffy blood group antigens in direct antiglobulin test (DAT)-positive red blood cells of AIHA patients and provide corresponding antigen-matched blood for transfusion therapy. MATERIALS AND METHODS: Blood samples from 50 normal blood donors and 30 DAT-positive AIHA patients were tested using standard serological techniques and polymerase chain reaction-based methods for Kell (K/k), Kidd (Jka/Jkb), and Duffy (Fya/Fyb) blood group systems. Five patients requiring blood transfusion were given donor blood units identical for Kell, Kidd, and Duffy antigens and followed up. RESULTS: Genotyping and phenotyping results were 100% concordant for normal blood donors. Serological phenotyping of minor red cell antigens showed varied degree of agglutination for AIHA patients. The molecular typing was able to detect the antigen frequency accurately in all samples. The results of genotyping were used to provide Kell-, Kidd-, and Duffy-matched blood for transfusion therapy to AIHA patients with no adverse reaction. CONCLUSION: Molecular blood group typing has proved immensely useful in the determination of actual antigen profile and hence in providing appropriate transfusion support in patients with AIHA reduced risk of transfusion reactions and alloimmunization.
- 1 January 2024
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 18 (1) , 56-61
Open AccessMolecular typing of Kell, Kidd, and Duffy antigens in direct antiglobulin test-positive autoimmune hemolytic anemia patients
BACKGROUND: In autoimmune hemolytic anemia (AIHA) patients, conventional pretransfusion testing is difficult to interpret due to the presence of autoantibodies which may show panreactivity. Molecular phenotyping of red cell antigens could potentially be used to precisely match blood units, thereby reducing the need to perform intensive serologic laboratory testing, hence time delay in providing transfusion to such patients. The aim of this study is to perform the molecular typing for Kell, Kidd, and Duffy blood group antigens in direct antiglobulin test (DAT)-positive red blood cells of AIHA patients and provide corresponding antigen-matched blood for transfusion therapy. MATERIALS AND METHODS: Blood samples from 50 normal blood donors and 30 DAT-positive AIHA patients were tested using standard serological techniques and polymerase chain reaction-based methods for Kell (K/k), Kidd (Jka/Jkb), and Duffy (Fya/Fyb) blood group systems. Five patients requiring blood transfusion were given donor blood units identical for Kell, Kidd, and Duffy antigens and followed up. RESULTS: Genotyping and phenotyping results were 100% concordant for normal blood donors. Serological phenotyping of minor red cell antigens showed varied degree of agglutination for AIHA patients. The molecular typing was able to detect the antigen frequency accurately in all samples. The results of genotyping were used to provide Kell-, Kidd-, and Duffy-matched blood for transfusion therapy to AIHA patients with no adverse reaction. CONCLUSION: Molecular blood group typing has proved immensely useful in the determination of actual antigen profile and hence in providing appropriate transfusion support in patients with AIHA reduced risk of transfusion reactions and alloimmunization.
- Open Access
- 1 January 2023
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 17 (1) , 53-57
A comparison of serological phenotyping and molecular genotyping for Kell, Kidd, and Duffy antigens in multi-transfused thalassemia patients
BACKGROUND: In multi-transfused thalassemia patients, serological phenotyping fails to test patient's actual blood group antigen profile due to the presence of donor red blood cell (RBC) in the circulation. This limitation of serological tests can be overcome by genotype determination using the polymerase chain reaction (PCR)-based methods. The aim of this study is to compare the serological phenotyping of Kell, Kidd, and Duffy blood group systems with molecular genotyping in the normal blood donors and multi-transfused thalassaemia patients. MATERIALS AND METHODS: Blood samples from 100 normal blood donors and 50 thalassemia patients were tested using standard serological techniques and PCR-based methods for Kell (K/k), Kidd (Jka/Jkb), and Duffy (Fya/Fyb) blood group systems. The results were compared for concordance. RESULTS: Genotyping and phenotyping results were 100% concordant for normal blood donors whereas those for thalassemia patients showed 24% discordance. The frequency of alloimmunization in thalassemia patients was 8%. The results of genotyping were used to provide Kell, Kidd, and Duffy matched blood for transfusion therapy to thalassemia patients. CONCLUSION: The actual antigen profile in multitransfused thalassaemia patients can be reliably determined using genotyping. This would benefit in providing better antigen matched transfusion therapy to such patients hence reducing the rate of alloimmunization.
- 1 January 2023
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 17 (1) , 53-57
Open AccessA comparison of serological phenotyping and molecular genotyping for Kell, Kidd, and Duffy antigens in multi-transfused thalassemia patients
BACKGROUND: In multi-transfused thalassemia patients, serological phenotyping fails to test patient's actual blood group antigen profile due to the presence of donor red blood cell (RBC) in the circulation. This limitation of serological tests can be overcome by genotype determination using the polymerase chain reaction (PCR)-based methods. The aim of this study is to compare the serological phenotyping of Kell, Kidd, and Duffy blood group systems with molecular genotyping in the normal blood donors and multi-transfused thalassaemia patients. MATERIALS AND METHODS: Blood samples from 100 normal blood donors and 50 thalassemia patients were tested using standard serological techniques and PCR-based methods for Kell (K/k), Kidd (Jka/Jkb), and Duffy (Fya/Fyb) blood group systems. The results were compared for concordance. RESULTS: Genotyping and phenotyping results were 100% concordant for normal blood donors whereas those for thalassemia patients showed 24% discordance. The frequency of alloimmunization in thalassemia patients was 8%. The results of genotyping were used to provide Kell, Kidd, and Duffy matched blood for transfusion therapy to thalassemia patients. CONCLUSION: The actual antigen profile in multitransfused thalassaemia patients can be reliably determined using genotyping. This would benefit in providing better antigen matched transfusion therapy to such patients hence reducing the rate of alloimmunization.
- Open Access
- 1 January 2021
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 15 (1) , 21-29
Implementation of internal quality control program for monitoring of enzyme-linked immunosorbent assay performance at a blood center
BACKGROUND: Internal quality control (IQC) samples may be incorporated in enzyme-linked immunosorbent assay (ELISA) routinely for detection of errors occurring due to change in environmental conditions, test system, or operator performance. We have described methodology for preparation of IQC samples, monitoring of results using Levey–Jennings (LJ) charts and their interpretation. We have also described our experience of quality control in ELISA using IQC samples, identification of errors and corrections applied. MATERIALS AND METHODS: IQC samples for anti-HIV, hepatitis B surface antigen (HBsAg), and anti-HCV ELISA were prepared “in-house” using standard methodology. After validation of run, E-ratio of IQC sample was calculated and plotted on LJ chart. Further interpretation was done to detect the errors. LJ charts illustrating the performance of IQC samples on 180 runs for each ELISA were drawn and analyzed. RESULTS: For anti-HIV ELISA, violation of warning rule was found in 2 runs (1.11%). Only one run (0.55%) was rejected due to violation of rejection rule. For HBsAg ELISA, violation of warning rule was indicated in two runs (1.11%). Two runs (1.11%) were rejected due to violation of rejection rules. For anti-HCV ELISA, violation of warning rule was indicated in two runs (1.11%), whereas two runs were rejected due to violation of rejection rules. Comprehensive checks were performed for the evaluation of equipment calibration, handling, and storage temperature of reagents and operator's technique. A thorough investigation was undertaken according to the type of error. CONCLUSION: Inclusion of IQC with each ELISA run is valuable to check the assay performance, ensuring reliability and reproducibility of test results.
- 1 January 2021
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 15 (1) , 21-29
Open AccessImplementation of internal quality control program for monitoring of enzyme-linked immunosorbent assay performance at a blood center
BACKGROUND: Internal quality control (IQC) samples may be incorporated in enzyme-linked immunosorbent assay (ELISA) routinely for detection of errors occurring due to change in environmental conditions, test system, or operator performance. We have described methodology for preparation of IQC samples, monitoring of results using Levey–Jennings (LJ) charts and their interpretation. We have also described our experience of quality control in ELISA using IQC samples, identification of errors and corrections applied. MATERIALS AND METHODS: IQC samples for anti-HIV, hepatitis B surface antigen (HBsAg), and anti-HCV ELISA were prepared “in-house” using standard methodology. After validation of run, E-ratio of IQC sample was calculated and plotted on LJ chart. Further interpretation was done to detect the errors. LJ charts illustrating the performance of IQC samples on 180 runs for each ELISA were drawn and analyzed. RESULTS: For anti-HIV ELISA, violation of warning rule was found in 2 runs (1.11%). Only one run (0.55%) was rejected due to violation of rejection rule. For HBsAg ELISA, violation of warning rule was indicated in two runs (1.11%). Two runs (1.11%) were rejected due to violation of rejection rules. For anti-HCV ELISA, violation of warning rule was indicated in two runs (1.11%), whereas two runs were rejected due to violation of rejection rules. Comprehensive checks were performed for the evaluation of equipment calibration, handling, and storage temperature of reagents and operator's technique. A thorough investigation was undertaken according to the type of error. CONCLUSION: Inclusion of IQC with each ELISA run is valuable to check the assay performance, ensuring reliability and reproducibility of test results.
- 9 May 2019
- Published by Wiley in Transfusion Medicine
- Vol. 29 (4) , 279-283
A comparison of lancets and evaluation of various manoeuvres in reducing finger prick pain during pre‐donation haemoglobin estimation
Summary: Objectives: Three different types of lancets have been compared to identify and implement the one that causes the least pain. Simple manoeuvres during the lancing procedure have been evaluated to determine their effectiveness in reducing the intensity of perceived pain.Background: Pre‐donation haemoglobin estimation is performed by pricking the donor's finger with a lancet. Pain associated with the procedure causes fear and anxiety, which dissuades the donors from donating blood.Methods: In 100 subjects, finger prick was performed using three different lancets, and the subjects were asked to score their pain on a numerical rating scale (NRS). A further 150 blood donors were subjected to routine finger pricking for Hb estimation and were asked to score their pain on an NRS. After 15 min, they underwent a second prick with application of a manoeuvre (breath holding, coughing trick or looking away) and again marked their pain scores on the NRS.Results: Participants reported the least pain scores with lancing devices that have a spring mechanism to retract the lancets soon after penetration into the skin. Breath holding and the cough trick manoeuvre reduced the perceived pain scores significantly.Conclusion: Lancing devices merit consideration for routine use, and a simple manoeuvre may be applied to reduce perceived pain.
- 9 May 2019
- Published by Wiley in Transfusion Medicine
- Vol. 29 (4) , 279-283
A comparison of lancets and evaluation of various manoeuvres in reducing finger prick pain during pre‐donation haemoglobin estimation
Summary: Objectives: Three different types of lancets have been compared to identify and implement the one that causes the least pain. Simple manoeuvres during the lancing procedure have been evaluated to determine their effectiveness in reducing the intensity of perceived pain.Background: Pre‐donation haemoglobin estimation is performed by pricking the donor's finger with a lancet. Pain associated with the procedure causes fear and anxiety, which dissuades the donors from donating blood.Methods: In 100 subjects, finger prick was performed using three different lancets, and the subjects were asked to score their pain on a numerical rating scale (NRS). A further 150 blood donors were subjected to routine finger pricking for Hb estimation and were asked to score their pain on an NRS. After 15 min, they underwent a second prick with application of a manoeuvre (breath holding, coughing trick or looking away) and again marked their pain scores on the NRS.Results: Participants reported the least pain scores with lancing devices that have a spring mechanism to retract the lancets soon after penetration into the skin. Breath holding and the cough trick manoeuvre reduced the perceived pain scores significantly.Conclusion: Lancing devices merit consideration for routine use, and a simple manoeuvre may be applied to reduce perceived pain.
- Open Access
- 1 January 2019
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 13 (1) , 23-29
A study on factors influencing the hemostatic potential of fresh frozen plasma
Background: Fresh frozen plasma (FFP) is administered to correct deficiencies of various coagulation factors. The level of these factors in FFP varies with donor demographics and ex-vivo processing of plasma. In this study we have compared the quality control parameters of FFP collected from donors of different genders, age groups, ABO blood groups, smoking and alcohol intake habits. Materials and Methods: Four ABO group matched plasma units were pooled, split and further processed by four different freeze-thaw algorithms: frozen by contact shock freezer; thawed at 37°C, frozen by contact shock freezer; thawed at 45°C, frozen by mechanical freezer; thawed at 37°C, frozen by mechanical freezer; thawed at 45°C. The coagulation factor levels in plasma units were compared. Results: There were no significant differences in the quality parameters with donor age, gender and alcohol intake. Factor VIII levels were significantly lower in O group FFP (P < 0.05). Smokers had significantly higher levels of fibrinogen (P < 0.05). There were no significant differences in PT, fibrinogen and factor VII levels of FFP processed through various algorithms. Plasma frozen rapidly through contact shock freezer had significantly lower aPTT and higher levels of factor V and VIII compared to mechanical freezing. There were no significant differences between PT, aPTT, fibrinogen, factor V, factor VII and factor VIII levels of FFP thawed at 37°C and 45°C. Mean thawing time was 28 minutes at 37°C and 17 minutes at 45°C. Conclusion: Rapid freezing is recommended for optimum preservation of coagulation factors. Thawing may be done at 45°C in cases of emergency, without compromising hemostatic potential.
- 1 January 2019
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 13 (1) , 23-29
Open AccessA study on factors influencing the hemostatic potential of fresh frozen plasma
Background: Fresh frozen plasma (FFP) is administered to correct deficiencies of various coagulation factors. The level of these factors in FFP varies with donor demographics and ex-vivo processing of plasma. In this study we have compared the quality control parameters of FFP collected from donors of different genders, age groups, ABO blood groups, smoking and alcohol intake habits. Materials and Methods: Four ABO group matched plasma units were pooled, split and further processed by four different freeze-thaw algorithms: frozen by contact shock freezer; thawed at 37°C, frozen by contact shock freezer; thawed at 45°C, frozen by mechanical freezer; thawed at 37°C, frozen by mechanical freezer; thawed at 45°C. The coagulation factor levels in plasma units were compared. Results: There were no significant differences in the quality parameters with donor age, gender and alcohol intake. Factor VIII levels were significantly lower in O group FFP (P < 0.05). Smokers had significantly higher levels of fibrinogen (P < 0.05). There were no significant differences in PT, fibrinogen and factor VII levels of FFP processed through various algorithms. Plasma frozen rapidly through contact shock freezer had significantly lower aPTT and higher levels of factor V and VIII compared to mechanical freezing. There were no significant differences between PT, aPTT, fibrinogen, factor V, factor VII and factor VIII levels of FFP thawed at 37°C and 45°C. Mean thawing time was 28 minutes at 37°C and 17 minutes at 45°C. Conclusion: Rapid freezing is recommended for optimum preservation of coagulation factors. Thawing may be done at 45°C in cases of emergency, without compromising hemostatic potential.
- Open Access
- 1 June 2018
- Published by Manipal College of Nursing, Manipal Academy of Higher Education in Manipal Journal of Medical Sciences
- Vol. 3 (1) , 6
An audit of blood collection process at a blood donation centre of a tertiary care hospital in North India
The process of blood collection should be carried out by trained health care personnel so as to reduce the adverse effects on donors and improve the quality of blood components. This is also important in preventing laboratory errors and injury to the health care personnel. This study was carried out to observe nonconformities in the process of whole blood, apheresis and blood sample collection at our centre, so as to improvise the practices. The data was collected on 5000 whole blood donations, 100 apheresis procedures and 500 blood samplings for screening prior to apheresis. It was analyzed for the frequency of nonconformities. Several nonconformities were noticed in the processes of donor identification, phlebotomy procedure, implementation of biosafety measures and management of adverse donor reactions. The nonconformities were found more in whole blood donations when compared to apheresis screening and procedure. Through the results of this study, we were able to identify the areas that were most vulnerable for deviations and nonconformities. Thereafter, we framed a relevant and targeted competency training program which reinforced personnel’s understanding of the importance of various steps in the process of blood collection. Subsequently, there was a substantial reduction in the nonconformities at our blood donation centre
- 1 June 2018
- Published by Manipal College of Nursing, Manipal Academy of Higher Education in Manipal Journal of Medical Sciences
- Vol. 3 (1) , 6
Open AccessAn audit of blood collection process at a blood donation centre of a tertiary care hospital in North India
The process of blood collection should be carried out by trained health care personnel so as to reduce the adverse effects on donors and improve the quality of blood components. This is also important in preventing laboratory errors and injury to the health care personnel. This study was carried out to observe nonconformities in the process of whole blood, apheresis and blood sample collection at our centre, so as to improvise the practices. The data was collected on 5000 whole blood donations, 100 apheresis procedures and 500 blood samplings for screening prior to apheresis. It was analyzed for the frequency of nonconformities. Several nonconformities were noticed in the processes of donor identification, phlebotomy procedure, implementation of biosafety measures and management of adverse donor reactions. The nonconformities were found more in whole blood donations when compared to apheresis screening and procedure. Through the results of this study, we were able to identify the areas that were most vulnerable for deviations and nonconformities. Thereafter, we framed a relevant and targeted competency training program which reinforced personnel’s understanding of the importance of various steps in the process of blood collection. Subsequently, there was a substantial reduction in the nonconformities at our blood donation centre
- Open Access
- 1 January 2018
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 12 (1) , 93-94
A curious case of thick white slick in a blood bag
Asian Journal of Transfusion Science (AJTS, ISSN 0973-6247) is publication of Indian Society of Blood Transfusion and Immunohemtology (ISBTI).
- 1 January 2018
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 12 (1) , 93-94
Open AccessA curious case of thick white slick in a blood bag
Asian Journal of Transfusion Science (AJTS, ISSN 0973-6247) is publication of Indian Society of Blood Transfusion and Immunohemtology (ISBTI).
- Open Access
- 1 January 2017
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 11 (2) , 215-216
Hello…. there is a blob of quark in my cryo bag!!
Asian Journal of Transfusion Science (AJTS, ISSN 0973-6247) is publication of Indian Society of Blood Transfusion and Immunohemtology (ISBTI).
- 1 January 2017
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 11 (2) , 215-216
Open AccessHello…. there is a blob of quark in my cryo bag!!
Asian Journal of Transfusion Science (AJTS, ISSN 0973-6247) is publication of Indian Society of Blood Transfusion and Immunohemtology (ISBTI).
- Open Access
- 1 January 2017
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 11 (1) , 50-52
Snake in the grass: A case report of transfusion reactions due to contaminated donor arm disinfectant
Bacterial contamination of blood components remains an on-going challenge. In the majority of cases, organisms contaminating the blood components are a part of normal skin flora. Here, we report a case of bacterial contamination of blood units through contaminated donor arm disinfectant. There was a series of reactions due to random donor platelet (RDP) transfusion. The patients had features of septic transfusion reactions. On root cause analysis, spirit swabs used for disinfection of donors' arm were identified as the culprit and presence of Clostridium difficile was established. All the blood components prepared on the dates of implicated RDP units were removed from the stock and we replaced the existing 70% alcohol disinfectant with chlorhexidine-alcohol-based antiseptic rub. Further, no such transfusion reactions were reported. Implementation of good donor arm disinfection technique in addition to the use of blood bags with diversion pouch is proposed to be best preventive strategy for resource-poor settings.
- 1 January 2017
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 11 (1) , 50-52
Open AccessSnake in the grass: A case report of transfusion reactions due to contaminated donor arm disinfectant
Bacterial contamination of blood components remains an on-going challenge. In the majority of cases, organisms contaminating the blood components are a part of normal skin flora. Here, we report a case of bacterial contamination of blood units through contaminated donor arm disinfectant. There was a series of reactions due to random donor platelet (RDP) transfusion. The patients had features of septic transfusion reactions. On root cause analysis, spirit swabs used for disinfection of donors' arm were identified as the culprit and presence of Clostridium difficile was established. All the blood components prepared on the dates of implicated RDP units were removed from the stock and we replaced the existing 70% alcohol disinfectant with chlorhexidine-alcohol-based antiseptic rub. Further, no such transfusion reactions were reported. Implementation of good donor arm disinfection technique in addition to the use of blood bags with diversion pouch is proposed to be best preventive strategy for resource-poor settings.