Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrzej Marcinek has a total of 307 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sex-specific differences in vascular circulation and metabolic regulation associated with aging and cardiovascular health problems

    by Andrzej Marcinek, Joanna Katarzynska, Jerzy Gebicki

    The Flow Mediated Skin Fluorescence–Post-Occlusive Reactive Hyperemia (FMSF–PORH) technique proves that the skin can serve as an easily accessible and sensitive model for monitoring systemic redox changes in the NADH/NAD + balance. The three most important diagnostic parameters of the method are related to the response to transient ischemia. Hyperemic Response (HR max ) characterizes the hyperemia phase and reflects the rapid increase in macrocirculatory blood flow after occlusion of the brachial artery. Hypoxia Sensitivity (HS) characterizes the reperfusion phase, by assessing the activation of myogenic microcirculatory oscillations. Ischemic Response (IR max ) is related to the ischemia phase and reflects the adaptation of cellular metabolism to ischemia. All three FMSF–PORH parameters depend on health condition and age. Sex-specific differences in the FMSF–PORH parameters are not seen in young healthy individuals, but appear with cardiovascular health problems and/or advanced age. Females compared to males have a significantly lower the IR max parameter, characterizing metabolic (mitochondrial) regulation. In contrast, the HR max parameter, characterizing macrocirculation, is higher in females than in males. All parameters slowly deteriorate with age and cardiovascular health problems. The results of this study highlight the need for a sex-specific perspective on vascular and metabolic health, as well as differentiated preventive healthcare strategies.

  • Open Access

    Prediction of Microvascular Adaptation to Hypoxia Based on Myogenic Microcirculation Oscillations

    by Andrzej Marcinek, Joanna Katarzynska, Artur Stanek, Jerzy Gebicki

    Microcirculatory oscillations known as flowmotion are a recognized feature of blood flow that reflect the functional state of the vascular system. Many diseases are associated with impaired flowmotion, especially diseases that are accompanied by hypoxia. Low-frequency myogenic oscillations (0.052–0.15 Hz) are an important regulator of microvascular adaptation to hypoxia. Here, we study the myogenic component of flowmotion using the FMSF–PORH (Flow Mediated Skin Fluorescence–Post Occlusive Reactive Hyperemia) technique. Myogenic oscillations were strongly activated under hypoxic conditions caused by occlusion of the brachial artery or intermittent hypoxic treatment. A strong correlation was noted between the hypoxia sensitivity parameter HS (the intensity of myogenic oscillations activated by hypoxia) and the normoxic myogenic flowmotion parameter VM (the intensity of myogenic oscillations under normoxic conditions). If HS is considered as a direct measure of the microcirculation response to hypoxia, then VM can be considered a measure of the microcirculation’s readiness to provide this response. The predictive value of the VM parameter is presented. The assessment of myogenic activity under normoxia conditions could thus provide a simple and rapid diagnostic tool for health care practitioners.


  • Open Access

    Prediction of Microvascular Adaptation to Hypoxia Based on Myogenic Microcirculation Oscillations

    by Andrzej Marcinek, Joanna Katarzynska, Artur Stanek, Jerzy Gebicki

    Microcirculatory oscillations known as flowmotion are a recognized feature of blood flow that reflect the functional state of the vascular system. Many diseases are associated with impaired flowmotion, especially diseases that are accompanied by hypoxia. Low frequency myogenic oscillations (0.052–0.15 Hz) are an important regulator of microvascular adaptation to hypoxia. Here, we study the myogenic component of flowmotion using the FMSF–PORH (Flow Mediated Skin Fluorescence–Post Occlusive Reactive Hyperemia) technique. Myogenic oscillations were strongly activated under hypoxic conditions caused by occlusion of brachial artery or intermittent hypoxic treatment. A strong correlation was noted between the hypoxia sensitivity parameter HS (the intensity of myogenic oscillations activated by hypoxia) and the normoxic myogenic flowmotion parameter VM (the intensity of myogenic oscillations under normoxia conditions). If HS is considered as a direct measure of the microcirculation response to hypoxia, then VM can be considered a measure of the microcirculation's readiness to provide this response. The assessment of myogenic activity under normoxia conditions could thus provide a simple and rapid diagnostic tool for health care practitioners.

  • Open Access

    Simultaneous assessment of mitochondrial and vascular function using the Flow Mediated Skin Fluorescence technique

    by Andrzej Marcinek, Joanna Katarzynska, Jerzy Gebicki

    Flow Mediated Skin Fluorescence (FMSF) is a new non-invasive diagnostic method for assessing vascular circulation and/or metabolic regulation. The method measures stimulation of the circulation in response to post-occlusive reactive hyperemia (PORH). It analyzes the dynamical changes in NADH fluorescence emitted from skin tissue, providing information on mitochondrial metabolic status and intracellular oxygen delivery through the circulatory system. Assessment of the vascular state using the FMSF technique is based on three parameters: flowmotion (FM) under normoxia conditions, hypoxia sensitivity (HS), and hyperemic response (HRmax). The functioning of mitochondria can be assessed by analyzing the ischemic response (IRmax), hypoxia sensitivity (HS), and the basal level of NADH fluorescence. There is a close relationship between the functioning of mitochondria and the vascular system. Despite these interactions, mitochondrial and vascular regulatory function can be monitored separately as well as simultaneously by the FMSF technique. Uniquely, this approach delivers information on both mitochondrial and vascular function based on a single measurement.


  • Open Access

    Assessment of Microvascular Function Based on Flowmotion Monitored by the Flow-Mediated Skin Fluorescence Technique

    by Andrzej Marcinek, Joanna Katarzynska, Katarzyna Cypryk, Agnieszka Los-Stegienta, Jolanta Slowikowska-Hilczer, Renata Walczak-Jedrzejowska, Jacek Zielinski, Jerzy Gebicki

    This review summarizes studies dedicated to the assessment of microvascular function based on microcirculatory oscillations monitored by the Flow-Mediated Skin Fluorescence (FMSF) technique. Two approaches are presented. The first approach uses oscillatory parameters measured under normoxic conditions, expressed as flowmotion (FM), vasomotion (VM), and the normoxia oscillatory index (NOI). These parameters have been used for the identification of impaired microcirculatory oscillations associated with intense physical exercise, post-COVID syndrome, psychological stress, and erectile dysfunction. The second approach involves characterization of the microcirculatory response to hypoxia based on the measurement of hypoxia sensitivity (HS). The HS parameter is used to characterize microvascular complications in diabetes, such as diabetic kidney disease and diabetic foot ulcers. Based on research conducted by the authors of this review, the FMSF parameter ranges characterizing microvascular function are presented. The diagnostic approach to assessing microvascular function based on flowmotion monitored by the FMSF technique has a wide range of applications and the potential to be integrated into widespread medical practice.


  • Open Access

    Assessment of Microvascular Function Based on Flowmotion Monitored by the FMSF Technique

    by Andrzej Marcinek, Joanna Katarzynska, Katarzyna Cypryk, Agnieszka Los-Stegienta, Jolanta Slowikowska-Hilczer, Renata Walczak-Jedrzejowska, Jacek Zielinski, Jerzy Gebicki

    This review summarizes studies dedicated to the assessment of microvascular function based on microcirculatory oscillations monitored by the FMSF technique. Two approaches are presented. The first approach uses oscillatory parameters measured under normoxia conditions, expressed as flowmotion (FM), vasomotion (VM), and the normoxia oscillatory index (NOI). These parameters have been used for identification of impaired microcirculatory oscillations associated with intense physical exercise, post-COVID syndrome, psychological stress, and erectile dysfunction. The second approach involves characterization of the microcirculatory response to hypoxia based on the measurement of hypoxia sensitivity (HS). The HS parameter is used to characterize microvascular complications in diabetes, such as diabetic kidney disease and diabetic foot ulcers. Based on research conducted by the authors of this review, the FMSF parameter ranges characterizing microvascular function are presented. The diagnostic approach to assessing microvascular function based on flowmotion monitored by the FMSF technique has a wide range of applications and potential to be integrated into widespread medical practice.


  • Open Access

    A New Approach to Vascular Screening: Identification of Impaired Vascular Function Using the FMSF Technique

    by Andrzej Marcinek, Joanna Katarzynska, Jerzy Gebicki

    Arterial blood pressure monitoring plays an important role in preventive medicine, allowing, in selected cases, the identification of vascular dysfunction. In this review, we propose a new non-invasive approach to assessment of the circulatory system, based on its reaction to hypoxia induced by post-occlusive reactive hyperemia (PORH). Three key parameters can be used for vascular screening: the Reactive Hyperemia Response (RHR), which represents the overall reaction of the macro- and microcirculation to transient hypoxia; Hypoxia Sensitivity (HS), which reflects hypoxia-induced activation of myogenic oscillations of the microcirculation; and Normoxia Oscillatory Index (NOI), which characterizes microcirculatory oscillations under normoxia conditions. A method for assessing these parameters, analogous in simplicity to arterial blood pressure measurement, is provided by the Flow Mediated Skin Fluorescence (FMSF) technique. Reference values are proposed based on numerous test measurements.


  • Open Access

    Assessment of NADH/NAD+ Redox Imbalance in Psoriatic Lesions Using the FMSF Technique: Therapeutic Aspects

    by Jerzy Gebicki, Tomasz Filipiak, Andrzej Marcinek, Anna Wozniacka

    Mitochondrial dysfunction has been linked to psoriasis, and it may be an important underlying factor contributing to this disease. However, a precise methodology for assessing mitochondrial dysfunction has yet to be developed. One promising approach is to measure NADH autofluorescence from the affected skin areas. In this study, we show that Flow-Mediated Skin Fluorescence (FMSF) can be used for the non-invasive assessment of mitochondrial dysfunction in psoriasis. The fluorescence level at baseline and the half-time of ischemic growth (t1/2) derived from the FMSF traces can be used for the non-invasive assessment of NADH/NAD+ redox imbalance in psoriatic lesions compared to unaffected skin. These results are supported by an analysis of the key FMSF parameters: Reactive Hyperemia Response (RHR) and Hypoxia Sensitivity (HS). This method not only contributes to understanding the biochemical processes involved in the etiopathogenesis of psoriasis, but it also provides a basis for identifying new drug targets and improving the treatment process.


  • Open Access

    Assessment of NADH/NAD+ Redox Imbalance in Psoriatic Lesions Using the FMSF Technique: Therapeutic Aspects

    by Jerzy Gebicki, Tomasz Filipiak, Andrzej Marcinek, Anna Woźniacka

    Mitochondrial dysfunction has been linked to psoriasis, and may be an important underlying factor contributing to this disease. However, a precise methodology for assessing mitochondrial dysfunction has yet to be developed. One promising approach is to measure NADH autofluorescence from affected skin areas. In this study, we show that Flow Mediated Skin Fluorescence (FMSF) can be used for non-invasive assessment of mitochondrial dysfunction in psoriasis. The fluorescence level at baseline and the half-time of ischemic growth (t1/2) derived from the FMSF traces can be used for non-invasive assessment of NADH/NAD+ redox imbalance in psoriatic lesions compared to unaffected skin. These results are supported by analysis of the key FMSF parameters, Reactive Hyperemia Response (RHR) and Hypoxia Sensitivity (HS). This method not only contributes to understanding of the biochemical processes involved in the etiopathogenesis of psoriasis, but also provides a basis for identifying new drug targets and improving the treatment process.


  • Open Access

    Non-Invasive Assessment of Vascular Circulation Based on Flow Mediated Skin Fluorescence (FMSF)

    by Andrzej Marcinek, Joanna Katarzynska, Leslaw Sieron, Robert Skokowski, Jacek Zielinski, Jerzy Gebicki

    Flow Mediated Skin Fluorescence (FMSF) is a new non-invasive method for assessing vascular circulation and/or metabolic regulation. It enables assessment of both vasoconstriction and vasodilation. The method measures stimulation of the circulation in response to post-occlusive reactive hyperemia (PORH). It analyzes the dynamical changes in the emission of NADH fluorescence from skin tissue, providing the information on mitochondrial metabolic status and intracellular oxygen delivery through the circulatory system. Assessment of the vascular state using the FMSF technique is based on three parameters: reactive hyperemia response (RHR), hypoxia sensitivity (HS), and normoxia oscillatory index (NOI). The RHR and HS parameters determine the risk of vascular circulatory disorders and are the main diagnostic parameters. The NOI parameter is an auxiliary parameter for evaluating the state of microcirculation under stress of various origins (e.g., emotional stress, physical exhaustion, or post-infection stress). The clinical data show that the risk of vascular complications is limited among people whose RHR, log(HS), and NOI parameters are not significantly below the mean values determined by the FMSF technique, especially if they simultaneously meet the conditions RHR > 30% and log(HS) > 1.5 (HS > 30), and NOI > 60%.