Ralf Kaegi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ralf Kaegi has a total of 304 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Voegelin
Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600 Dübendorf, Switzerland
15 shared publications - Ruben Kretzschmar
Soil Chemistry Group, Institute of Biogeochemistry and Pollutant Dynamics, ETH Zurich, CHN, Universitätstrasse 16, 8092 Zurich, Switzerland
11 shared publications - Laurel K. ThomasArrigo
Environmental Chemistry, Institute of Chemistry, University of Neuchatel
8 shared publications - Jonas Wielinski
Department of Civil and Environmental Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213, USA
7 shared publications - Alexander Gogos
Nanomaterials in Health Laboratory Department of Materials Meet Life Swiss Federal Laboratories for Materials Science and Technology (Empa) St. Gallen Switzerland
5 shared publications - Eberhard Morgenroth
Eawag: Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland
5 shared publications
Latest Publications
- Open Access
- 12 November 2026
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 13 (11) , 4387-4398
How does organic matter affect Ce redox speciation and the formation of CeO 2 nanoparticles?
Understanding the interactions between trace metals and natural organic matter (OM) is crucial due to its influence on metal speciation, mobility, toxicity, and bioavailability.
- 12 November 2026
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 13 (11) , 4387-4398
Open AccessHow does organic matter affect Ce redox speciation and the formation of CeO 2 nanoparticles?
Understanding the interactions between trace metals and natural organic matter (OM) is crucial due to its influence on metal speciation, mobility, toxicity, and bioavailability.
- Open Access
- 13 July 2026
- Published by American Chemical Society (ACS) in ACS ES&T Water
Microplastic Particle Loads Discharged by Swiss Wastewater Treatment Plants
- 13 July 2026
- Published by American Chemical Society (ACS) in ACS ES&T Water
Open AccessMicroplastic Particle Loads Discharged by Swiss Wastewater Treatment Plants
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
AFM-IR as a tool to detect nanoplastic particles in aerosols
Whereas the presence of microplastic particles (1µm – 1mm) have been documented all around the globe, the evidence for plastic particles in the submicrometer size range (
- 14 March 2026
- Published by Copernicus GmbH
Open AccessAFM-IR as a tool to detect nanoplastic particles in aerosols
Whereas the presence of microplastic particles (1µm – 1mm) have been documented all around the globe, the evidence for plastic particles in the submicrometer size range (
- Open Access
- 27 February 2026
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 13 (4) , 1910-1925
Possibilities and limitations of AFM-IR to detect nanoplastic particles in the atmosphere
Atomic force microscopy infrared spectroscopy provides sufficient spatial resolution and chemical specificity to identify nanoplastics. Application of the technique to environmental samples is restricted by high (particle-based) detection limits.
- 27 February 2026
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 13 (4) , 1910-1925
Open AccessPossibilities and limitations of AFM-IR to detect nanoplastic particles in the atmosphere
Atomic force microscopy infrared spectroscopy provides sufficient spatial resolution and chemical specificity to identify nanoplastics. Application of the technique to environmental samples is restricted by high (particle-based) detection limits.
- Open Access
- 23 February 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (9) , 7183-7193
Temperature Dependence of Poly(3-hydroxybutyrate- co -3-hydroxyhexanoate) Biodegradation in Agricultural Soils
Biodegradable polyesters are increasingly used in agricultural applications with soil biodegradation as the targeted postapplication end-of-life. Soil biodegradability is typically established in laboratory soil incubations at constant temperatures exceeding those in many field soils, highlighting the need for robust temperature-biodegradability relationships to transfer laboratory-determined biodegradation rates to field conditions. This work systematically assesses the temperature dependence of the biodegradation of three poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) (PHBHHx) variants, containing differing molar amounts of 3-hydroxyhexanoate (where x = 5, 9, and 12%) in three agricultural soils. Scanning electron microscopy images of PHBHH9 films incubated for 18 days showed increasing film surface colonization by fungi and/or filamentous bacteria from 5 to 15, 25, and 35 °C, with dense hyphal networks and film disintegration at the higher tested temperatures. Soil biodegradation of PHBHHx powders over the same temperature range was followed by extracting and quantifying residual PHBHHx mass over time by proton nuclear magnetic resonance spectroscopy. Fitting of these residual masses with a shoulder-log linear kinetic model yielded PHBHHx-variant-independent initial lag phases and biodegradation rate constants. Increasing the temperature shortened the initial lag phase and increased the subsequent rate of PHBHHx biodegradation. Arrhenius rate law analysis revealed soil-specific activation energies that correspond to approximately 2- to 5-fold changes in biodegradation rates per 10 °C. This work establishes temperature as a key abiotic factor controlling polyester biodegradation rates in soils and guides more accurate extrapolation of laboratory-determined biodegradation rates at elevated temperatures to field conditions.
- 23 February 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (9) , 7183-7193
Open AccessTemperature Dependence of Poly(3-hydroxybutyrate- co -3-hydroxyhexanoate) Biodegradation in Agricultural Soils
Biodegradable polyesters are increasingly used in agricultural applications with soil biodegradation as the targeted postapplication end-of-life. Soil biodegradability is typically established in laboratory soil incubations at constant temperatures exceeding those in many field soils, highlighting the need for robust temperature-biodegradability relationships to transfer laboratory-determined biodegradation rates to field conditions. This work systematically assesses the temperature dependence of the biodegradation of three poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) (PHBHHx) variants, containing differing molar amounts of 3-hydroxyhexanoate (where x = 5, 9, and 12%) in three agricultural soils. Scanning electron microscopy images of PHBHH9 films incubated for 18 days showed increasing film surface colonization by fungi and/or filamentous bacteria from 5 to 15, 25, and 35 °C, with dense hyphal networks and film disintegration at the higher tested temperatures. Soil biodegradation of PHBHHx powders over the same temperature range was followed by extracting and quantifying residual PHBHHx mass over time by proton nuclear magnetic resonance spectroscopy. Fitting of these residual masses with a shoulder-log linear kinetic model yielded PHBHHx-variant-independent initial lag phases and biodegradation rate constants. Increasing the temperature shortened the initial lag phase and increased the subsequent rate of PHBHHx biodegradation. Arrhenius rate law analysis revealed soil-specific activation energies that correspond to approximately 2- to 5-fold changes in biodegradation rates per 10 °C. This work establishes temperature as a key abiotic factor controlling polyester biodegradation rates in soils and guides more accurate extrapolation of laboratory-determined biodegradation rates at elevated temperatures to field conditions.
- Open Access
- 14 October 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (27) , 6191-6208
Quantification of small (1–10 µm) microplastic particles in soil matrices using automated scanning electron microscopy: possibilities and limitations
Scanning electron microscopy (SEM) provides superb resolution power and allows distinguishing microplastic particles (MPs) from other particles based on elemental ratios derived from energy dispersive x-ray (EDX) analysis. Polycarbonate (PC) membranes are typically used to isolate MPs from suspensions for SEM investigations. This, however, results in poor (atomic weight) contrast between MPs and the underlying PC membrane, challenging automated particle detection. To introduce an elemental contrast between MPs and the PC membrane, a gold (Au) coating was applied to the PC membrane before use. Monte Carlo simulations conducted to optimize operational conditions of the SEM suggest an acceleration voltage of 3 kV in combination with a 40 nm Au coating of PC membranes as most appropriate. Stock suspensions made from polyethylene (PE) fragments, polyvinyl chloride (PVC) fragments, and standard soils, all sieved to 0.45–10 µm, were mixed at different ratios. Selected mixtures were density separated to isolate the MPs from the mixtures. Whereas up to 7% of PE was detected in PVC stocks, likely representing false positives, only negligible amounts of PVC were detected in PE stocks. In soils, neither PE nor PVC was detected in significant amounts. Polyethylene and PVC particles diluted in soil suspensions at particle number ratios of 1:1:2 and 1:1:2000 were density separated, and largely concentration independent recoveries of around 70% and 50% were obtained for PE and PVC, respectively. Good agreement between SEM-EDX and Raman measurements was obtained for MPs, underlining the strength of our approach to address the smallest size fraction of MPs in complex matrices. Graphical abstract
- 14 October 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (27) , 6191-6208
Open AccessQuantification of small (1–10 µm) microplastic particles in soil matrices using automated scanning electron microscopy: possibilities and limitations
Scanning electron microscopy (SEM) provides superb resolution power and allows distinguishing microplastic particles (MPs) from other particles based on elemental ratios derived from energy dispersive x-ray (EDX) analysis. Polycarbonate (PC) membranes are typically used to isolate MPs from suspensions for SEM investigations. This, however, results in poor (atomic weight) contrast between MPs and the underlying PC membrane, challenging automated particle detection. To introduce an elemental contrast between MPs and the PC membrane, a gold (Au) coating was applied to the PC membrane before use. Monte Carlo simulations conducted to optimize operational conditions of the SEM suggest an acceleration voltage of 3 kV in combination with a 40 nm Au coating of PC membranes as most appropriate. Stock suspensions made from polyethylene (PE) fragments, polyvinyl chloride (PVC) fragments, and standard soils, all sieved to 0.45–10 µm, were mixed at different ratios. Selected mixtures were density separated to isolate the MPs from the mixtures. Whereas up to 7% of PE was detected in PVC stocks, likely representing false positives, only negligible amounts of PVC were detected in PE stocks. In soils, neither PE nor PVC was detected in significant amounts. Polyethylene and PVC particles diluted in soil suspensions at particle number ratios of 1:1:2 and 1:1:2000 were density separated, and largely concentration independent recoveries of around 70% and 50% were obtained for PE and PVC, respectively. Good agreement between SEM-EDX and Raman measurements was obtained for MPs, underlining the strength of our approach to address the smallest size fraction of MPs in complex matrices. Graphical abstract
- Open Access
- 10 October 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (41) , 22777-22786
Oxygen Isotope Analyses of Phosphate and Organophosphorus Compounds by Electrospray Ionization Orbitrap Mass Spectrometry
Orbitrap mass spectrometry with electrospray ionization (ESI-Orbitrap MS) enables 18O/16O ratio measurements in phosphate and organophosphorus compounds, which offers promising avenues for the study of metabolic, biogeochemical, and environmental processes. While the instrumental feasibility of such 18O/16O ratio measurements has been shown, the applicability of such analyses in aqueous matrices on multipurpose mass spectrometers remains unaddressed. Here, we (i) evaluated the interplay between instrument parameters and the long-term accuracy and precision of ESI-Orbitrap MS for the determination of δ18O(PO4) from H2PO4- vs PO3- fragments of phosphate, (ii) identified properties of methanolic sample solutions that are critical for accurate and precise measurements, and (iii) propose a sample purification procedure for the elimination of matrix-based interferences. In 10 measurement campaigns over two years, we observed a long-term reproducibility of δ18O(PO4) within ±2.8‰. Results of in-source fragmentation experiments of H2PO4- to PO3- show excellent agreement of δ18O and offer promising opportunities to probe for 18O/16O ratios in organophosphorus compounds. By investigating the effect of the aqueous matrix and interfering anions on 18O/16O ratio measurements, we found that a water content exceeding 50 vol % and the presence of oxyanions such as nitrate and sulfate limit measurement accuracy due to interferences of matrix constituents in the ESI source. To overcome these challenges, we evaluated selective phosphate extraction with a zirconium-based metal-organic framework (MOF) as sorbent. The resulting purification procedure allowed for successful extraction and recovery of phosphate from nitrate- and sulfate-containing aqueous solutions, resulting in methanolic phosphate samples that enabled accurate analyses of δ18O(PO4) by ESI-Orbitrap MS.
- 10 October 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (41) , 22777-22786
Open AccessOxygen Isotope Analyses of Phosphate and Organophosphorus Compounds by Electrospray Ionization Orbitrap Mass Spectrometry
Orbitrap mass spectrometry with electrospray ionization (ESI-Orbitrap MS) enables 18O/16O ratio measurements in phosphate and organophosphorus compounds, which offers promising avenues for the study of metabolic, biogeochemical, and environmental processes. While the instrumental feasibility of such 18O/16O ratio measurements has been shown, the applicability of such analyses in aqueous matrices on multipurpose mass spectrometers remains unaddressed. Here, we (i) evaluated the interplay between instrument parameters and the long-term accuracy and precision of ESI-Orbitrap MS for the determination of δ18O(PO4) from H2PO4- vs PO3- fragments of phosphate, (ii) identified properties of methanolic sample solutions that are critical for accurate and precise measurements, and (iii) propose a sample purification procedure for the elimination of matrix-based interferences. In 10 measurement campaigns over two years, we observed a long-term reproducibility of δ18O(PO4) within ±2.8‰. Results of in-source fragmentation experiments of H2PO4- to PO3- show excellent agreement of δ18O and offer promising opportunities to probe for 18O/16O ratios in organophosphorus compounds. By investigating the effect of the aqueous matrix and interfering anions on 18O/16O ratio measurements, we found that a water content exceeding 50 vol % and the presence of oxyanions such as nitrate and sulfate limit measurement accuracy due to interferences of matrix constituents in the ESI source. To overcome these challenges, we evaluated selective phosphate extraction with a zirconium-based metal-organic framework (MOF) as sorbent. The resulting purification procedure allowed for successful extraction and recovery of phosphate from nitrate- and sulfate-containing aqueous solutions, resulting in methanolic phosphate samples that enabled accurate analyses of δ18O(PO4) by ESI-Orbitrap MS.
- Open Access
- 14 September 2025
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 498, 139875
Efficient removal of microplastic particles from wastewater through formation of heteroagglomerates during the activated sludge process
- 14 September 2025
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 498, 139875
Open AccessEfficient removal of microplastic particles from wastewater through formation of heteroagglomerates during the activated sludge process
- Open Access
- 17 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Oxygen Isotope Analyses of Phosphate and Organophosphorus Compounds by Electrospray Ionization Orbitrap Mass Spectrometry
Orbitrap mass spectrometry with electrospray ionization (ESI-Orbitrap MS) enables 18O/16O ratio measurements in phosphate and organophosphorus compounds which offers promising avenues for the study of metabolic, biogeochemical, and environmental processes. While the instrumental feasibility of such 18O/16O ratio measurements has been shown, the applicability of such analyses in aqueous matrices on multi-purpose mass spectrometers remains unaddressed. Here, we (i) evaluated the interplay between instrument parameters and the long-term accuracy and precision of ESI-Orbitrap MS for the determination of d18O(PO4) from H2PO4– to PO3– fragments of phosphate, (ii) identified properties of methanolic sample solutions that are critical for accurate and precise measurements, and (iii) propose a sample purification procedure for elimination of matrix-based interferences. In ten measurement campaigns over two years, we observed a long-term reproducibility of d18O(PO4) within ±2.8‰. Results of in-source fragmentation experiments of H2PO4– to PO3– show excellent agreement of d18O and offer promising opportunities to probe for 18O/16O ratios in organophosphorus compounds. By investigating the effect of the aqueous matrix and interfering anions on 18O/16O ratio measurements, we found that a water content exceeding 50 vol-% and the presence of oxyanions such as nitrate and sulfate limit measurement accuracy due to interferences of matrix constituents in the ESI source. To overcome these challenges, we evaluated selective phosphate extraction with zirconium-based metal-organic framework (MOF) as sorbent. The resulting purification procedure allowed for successful extraction and recovery of phosphate from nitrate and sulfate-containing aqueous solutions, resulting in methanolic phosphate samples that enabled accurate analyses of d18O(PO4) by ESI-Orbitrap MS.
- 17 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessOxygen Isotope Analyses of Phosphate and Organophosphorus Compounds by Electrospray Ionization Orbitrap Mass Spectrometry
Orbitrap mass spectrometry with electrospray ionization (ESI-Orbitrap MS) enables 18O/16O ratio measurements in phosphate and organophosphorus compounds which offers promising avenues for the study of metabolic, biogeochemical, and environmental processes. While the instrumental feasibility of such 18O/16O ratio measurements has been shown, the applicability of such analyses in aqueous matrices on multi-purpose mass spectrometers remains unaddressed. Here, we (i) evaluated the interplay between instrument parameters and the long-term accuracy and precision of ESI-Orbitrap MS for the determination of d18O(PO4) from H2PO4– to PO3– fragments of phosphate, (ii) identified properties of methanolic sample solutions that are critical for accurate and precise measurements, and (iii) propose a sample purification procedure for elimination of matrix-based interferences. In ten measurement campaigns over two years, we observed a long-term reproducibility of d18O(PO4) within ±2.8‰. Results of in-source fragmentation experiments of H2PO4– to PO3– show excellent agreement of d18O and offer promising opportunities to probe for 18O/16O ratios in organophosphorus compounds. By investigating the effect of the aqueous matrix and interfering anions on 18O/16O ratio measurements, we found that a water content exceeding 50 vol-% and the presence of oxyanions such as nitrate and sulfate limit measurement accuracy due to interferences of matrix constituents in the ESI source. To overcome these challenges, we evaluated selective phosphate extraction with zirconium-based metal-organic framework (MOF) as sorbent. The resulting purification procedure allowed for successful extraction and recovery of phosphate from nitrate and sulfate-containing aqueous solutions, resulting in methanolic phosphate samples that enabled accurate analyses of d18O(PO4) by ESI-Orbitrap MS.
- Open Access
- 7 July 2025
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 27 (8) , 2479-2506
Effects of organic ligands, phosphate and Ca on the structure and composition of Fe(iii)-precipitates formed by Fe(ii) oxidation at near-neutral pH
The oxidation of dissolved Fe(II) in near-neutral natural waters leads to the formation of Fe(III)-precipitates. Organic ligands, PO4, calcium (Ca) and other solutes affect the composition, bulk and nanoscale structure and colloidal properties of Fe(III)-precipitates and their impacts on co-precipitated compounds in interdependent ways. In this study, we quantified the effects of four low molecular weight organic acids (LMWOAs) with different Fe(III) complexation strengths (2,4-dihydroxybenzoic acid (2,4-DHB) ∼ galacturonic acid (Galact) ≪ 3,4-dihydroxybenzoic acid (3,4-DHB) < citric acid (Citr)) and of leonardite humic acid (LH) in combination with PO4 and Ca on Fe(III)-precipitate structure and composition in a multifactorial experiment. Precipitates were synthesized by oxidation of 0.5 mM Fe(II) in bicarbonate-buffered solutions at pH ∼ 7, at molar (OC/Fe) ratios of 0.1 to 9.6, at molar (PO4/Fe) ratios of 0.05 and 0.25, and without/with 4 mM Ca. OC-free controls consisted of amorphous (Ca)Fe(III)–phosphate and ferrihydrite (Fh) aggregated in core–shell nanoparticles with lepidocrocite (Lp) crystallites attached to their surface, reflecting their formation sequence. The LMWOAs promoted the formation of OC-loaded Fh at the expense of Lp and thereby led to more effective PO4 retention and lower residual dissolved PO4. This effect increased with ligand concentration and Fe(III) complexation strength. At a higher PO4 level, the co-precipitation of all LMWOAs was reduced, reflecting the stronger affinity of PO4 for Fe(III). At higher (OC/Fe), the strong ligands 3,4-DHB and Citr increasingly co-precipitated with PO4 into (Ca)–Fe(III)–PO4–OC nanoparticles and led to the formation of Fe(III)-colloids and Fe(III)–organic complexes that passed 0.2 μm filter membranes at the highest tested (OC/Fe) levels. Macromolecular LH (humic acid) had similar effects on Fe coordination and PO4 uptake to 2,4-DHB and Galact, but distinct effects on the nanoscale precipitate structure and colloidal properties. Ca enhanced the co-precipitation of PO4 and OC with Fe(III), the aggregation of Fe(III)-precipitate particles, and LH coagulation. Collectively, the insights presented in this study highlight the need to take the type of OC, its concentration relative to Fe, and interdependent effects of OC, PO4, SiO4, and Ca into account when assessing the formation of Fe(III)-precipitates by Fe(II) oxidation in near-neutral natural waters and their impacts on the cycling of PO4, OC and other co-precipitating compounds.
- 7 July 2025
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 27 (8) , 2479-2506
Open AccessEffects of organic ligands, phosphate and Ca on the structure and composition of Fe(iii)-precipitates formed by Fe(ii) oxidation at near-neutral pH
The oxidation of dissolved Fe(II) in near-neutral natural waters leads to the formation of Fe(III)-precipitates. Organic ligands, PO4, calcium (Ca) and other solutes affect the composition, bulk and nanoscale structure and colloidal properties of Fe(III)-precipitates and their impacts on co-precipitated compounds in interdependent ways. In this study, we quantified the effects of four low molecular weight organic acids (LMWOAs) with different Fe(III) complexation strengths (2,4-dihydroxybenzoic acid (2,4-DHB) ∼ galacturonic acid (Galact) ≪ 3,4-dihydroxybenzoic acid (3,4-DHB) < citric acid (Citr)) and of leonardite humic acid (LH) in combination with PO4 and Ca on Fe(III)-precipitate structure and composition in a multifactorial experiment. Precipitates were synthesized by oxidation of 0.5 mM Fe(II) in bicarbonate-buffered solutions at pH ∼ 7, at molar (OC/Fe) ratios of 0.1 to 9.6, at molar (PO4/Fe) ratios of 0.05 and 0.25, and without/with 4 mM Ca. OC-free controls consisted of amorphous (Ca)Fe(III)–phosphate and ferrihydrite (Fh) aggregated in core–shell nanoparticles with lepidocrocite (Lp) crystallites attached to their surface, reflecting their formation sequence. The LMWOAs promoted the formation of OC-loaded Fh at the expense of Lp and thereby led to more effective PO4 retention and lower residual dissolved PO4. This effect increased with ligand concentration and Fe(III) complexation strength. At a higher PO4 level, the co-precipitation of all LMWOAs was reduced, reflecting the stronger affinity of PO4 for Fe(III). At higher (OC/Fe), the strong ligands 3,4-DHB and Citr increasingly co-precipitated with PO4 into (Ca)–Fe(III)–PO4–OC nanoparticles and led to the formation of Fe(III)-colloids and Fe(III)–organic complexes that passed 0.2 μm filter membranes at the highest tested (OC/Fe) levels. Macromolecular LH (humic acid) had similar effects on Fe coordination and PO4 uptake to 2,4-DHB and Galact, but distinct effects on the nanoscale precipitate structure and colloidal properties. Ca enhanced the co-precipitation of PO4 and OC with Fe(III), the aggregation of Fe(III)-precipitate particles, and LH coagulation. Collectively, the insights presented in this study highlight the need to take the type of OC, its concentration relative to Fe, and interdependent effects of OC, PO4, SiO4, and Ca into account when assessing the formation of Fe(III)-precipitates by Fe(II) oxidation in near-neutral natural waters and their impacts on the cycling of PO4, OC and other co-precipitating compounds.