WUWaqas Ullah

Waqas Ullah

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Waqas Ullah has a total of 157 co-authors. Here are the top co-authors by number of shared publications:

  • Mark J. Earley

    Cardiovascular Biomedical Research Unit, Barts Heart Centre, St. Bartholomew's Hospital, Barts Health National Health Service Trust, London, United Kingdom

    14 shared publications
  • Ross J. Hunter

    Cardiovascular Biomedical Research Unit, Barts Heart Centre, St. Bartholomew's Hospital, Barts Health National Health Service Trust, London, United Kingdom

    12 shared publications
  • Simon Sporton

    Cardiovascular Biomedical Research Unit, Barts Heart Centre, St. Bartholomew's Hospital, Barts Health National Health Service Trust, London, United Kingdom

    12 shared publications
  • Richard J. Schilling

    Cardiovascular Biomedical Research Unit, Barts Heart Centre, St. Bartholomew's Hospital, Barts Health National Health Service Trust, London, United Kingdom

    9 shared publications
  • Mehul B. Dhinoja

    Cardiovascular Biomedical Research Unit, Barts Heart Centre, St. Bartholomew's Hospital, Barts Health National Health Service Trust, London, United Kingdom

    7 shared publications
  • Victoria Baker

    Barts Heart Centre, St. Bartholomew's Hospital, Barts Health NHS Trust, London, UK

    7 shared publications

Latest Publications

  • Open Access

    Next-generation ICDs: Individualised Selection for Improved Cardiac Outcomes

    by Lin-Thiri Toon, Christopher Monkhouse, Waqas Ullah, John Paisey

    Cardiovascular disease is a major global cause of death, with sudden cardiac death accounting for up to half of cases, largely due to ventricular tachyarrhythmias. In the UK, approximately 60,000 out-of-hospital cardiac arrests occur annually, with survival rates of only 2–12%. Younger individuals are also affected, with one cardiac-related death daily in those under 35 years of age. Despite advances in care, arrhythmia recurrence remains high (40–50% within 5 years). ICDs have become pivotal in preventing sudden cardiac death, with continuous innovations in device design, implantation, and arrhythmia detection since their introduction in 1980. Transvenous single-chamber ICDs remain the standard, while dual-chamber and CRT defibrillator devices serve patients needing atrial pacing or heart failure support. Subcutaneous and extravascular ICD systems protect patients not requiring pacing while avoiding lead-related risks. Device selection must be individualised, considering clinical profile, comorbidities, lifestyle, patient preferences, and operator expertise. Ongoing advances, including leadless pacing and modular anti-tachycardia pacing systems, continue to expand personalised device strategies.


  • Open Access

    The Biophysics of Radiofrequency Ablation and Factors Affecting Lesion Size

    by Alexander P Bates, Waqas Ullah

    Radiofrequency ablation is the mainstay of interventional electrophysiology. The biophysics of radiofrequency ablation involve converting electrical energy into heat to irreversibly damage an area of myocardium. To create an ablation lesion, a temperature of >50°C must be generated in the tissue for 60 seconds. This is influenced by factors affecting either the current delivered, electrode impedance, ablation duration or the thermoconductive properties of the tissue. These factors can be altered to affect ablation lesion size to optimise arrhythmia treatment.


  • Open Access

    Comparison of voltages between atria: differences in sinus rhythm and atrial fibrillation

    by Alexander P. Bates, John Paisey, Arthur Yue, Phil Banks, Paul R. Roberts, Waqas Ullah

    Background: Ultra high-density mapping systems allow for comparison of atrial electroanatomical maps in unprecedented detail. Atrial scar determined by voltages and surface area between atria, rhythm and atrial fibrillation (AF) types was assessed. Methods: Left (LA) and right atrial (RA) maps were created using Rhythmia HDx in patients listed for ablation for paroxysmal (PAF, sinus rhythm (SR) maps only) or persistent AF (PeAF, AF and SR maps). Electrograms on corresponding SR/AF maps were paired for direct comparison. Percentage surface area of scar was assigned low- (LVM, ≤ 0.05 mV), intermediate- (IVM, 0.05–0.5 mV) or normal voltage myocardium, (NVM, > 0.5 mV). Results: Thirty-eight patients were recruited generating 96 maps using 913,480 electrograms. Paired SR-AF bipolar electrograms showed fair correlation in LA (Spearman’s ρ = 0.32) and weak correlation in RA (ρ = 0.19) and were significantly higher in SR in both (LA: 0.61 mV (0.20–1.67) vs 0.31 mV (0.10–0.74), RA: 0.68 mV (0.19–1.88) vs 0.47 mV (0.14–1.07), p < 0.0005 both). Voltages were significantly higher in patients with PAF over PeAF, (LA: 1.13 mV (0.39–2.93) vs 0.52 mV (0.16–1.49); RA: 0.93 mV (0.24–2.46) vs 0.57 mV (0.17–1.69)). Minimal differences were seen in electrogram voltages between atria. Significantly more IVM/LVM surface areas were seen in AF over SR (LA only, p < 0005), and PeAF over PAF (LA: p = 0.01, RA: p = 0.04). There was minimal difference between atria within patients. Conclusions: Ultra high-density mapping shows paired electrograms correlate poorly between SR and AF. SR electrograms are typically (but not always) larger than those in AF. Patients with PeAF have a lower global electrogram voltage than those with PAF. Electrogram voltages are similar between atria within individual patients.


  • Trends and outcomes of cardiogenic shock in Asian populations compared with non-Asian populations in the US: NIS Analysis (2002-2019)

    by Harigopal Sandhyavenu, Waqas Ullah, Irisha Badu, Amro Taha, Aravind Reddy Polam, Tanveer Mir, Yevgeniy Brailovsky, Indranee N. Rajapreyar, Saraschandra Vallabhajosyula, M Chadi Alraies

    Current understanding of outcomes of cardiogenic shock (CS) in Asian populations is limited. We aim to study the clinical outcomes of CS in Asian population compared with non-Asians in the US. The National Inpatient Sample (NIS) database was queried between 2002-2019 to identify hospitalizations with CS. Race was classified as Asians and non-Asians. The adjusted odds ratios (aOR) for in-hospital outcomes were calculated using multivariate logistic regression analysis. Results Of 1,573,285 CS hospitalizations, 48,398 (3%) were Asians and 1,524,887 (97%) were non-Asians between 2002-2019. Adjusted odds of in-hospital mortality (aOR 1.03, 95% CI 1.01–1.05), and use of intra-aortic balloon pump (IABP) (aOR 1.15, 95% CI 1.12–1.17) were significantly higher among Asians compared with non-Asians. The in-hospital mean cost of hospitalization was higher in Asian population ($63,787±$80,261) with CS compared with non-Asians ($56,207±$76,120, p < 0.001). The use of Impella (aOR 0.90, 95% CI 0.86–0.95) and left ventricular assist devices (LVAD) (aOR 0.71, 95% CI 0.65–0.77) were lower with no difference in the use of extracorporeal membrane oxygenation (ECMO) compared with non-Asians. Asian populations with CS have higher in-hospital mortality, increased requirement of IABP and higher mean cost of hospitalization compared with non-Asians.


  • Radiofrequency Ablation of the Diseased Human Left Ventricle

    by Alexander P. Bates, John Paisey, Arthur Yue, Phil Banks, Paul R. Roberts, Waqas Ullah


  • Iatrogenic cardiac perforation due to pacemaker and defibrillator leads: a contemporary multicentre experience

    by Peter H Waddingham, James Elliott, Alexander Bates, James Bilham, Amal Muthumala, Shohreh Honarbakhsh, Waqas Ullah, Ross J Hunter, Pier D Lambiase, Rebecca E Lane, et al.

    To determine the incidence, clinical features, management, and outcomes of pacemaker (PM) and implantable cardioverter-defibrillator (ICD) lead cardiac perforation. Cardiac perforations due to PM and ICD leads are rare but serious complications. Clinical features vary widely and may cause diagnostic delay. Management strategies are non-guideline based due to paucity of data. A multicentre retrospective series including 3 UK cardiac tertiary centres from 2016 to 2020. Patient, device, and lead characteristics were obtained including 6-month outcomes. Seventy cases of perforation were identified from 10 631 procedures; perforation rate was 0.50% for local implants. Thirty-nine (56%) patients were female, mean ( ± standard deviation) age 74 ( ± 13.8) years. Left ventricular ejection fraction 51 ( ± 13.2) %. Median time to diagnosis was 9 (range: 0–989) days. Computed tomography (CT) diagnosed perforation with 97% sensitivity. Lead parameter abnormalities were present in 86% (whole cohort) and 98.6% for perforations diagnosed >24 h. Chest pain was the commonest symptom, present in 46%. The management strategy was percutaneous in 98.6% with complete procedural success in 98.6%. Pericardial effusion with tamponade was present in 17% and was associated with significantly increased mortality and major complications. Anticoagulation status was associated with tamponade by multivariate analysis (odds ratio 21.7, 95% confidence interval: 1.7–275.5, P = 0.018). Perforation was rare (0.50%) and managed successfully by a percutaneous strategy with good outcomes. Tamponade was associated with increased mortality and major complications. Anticoagulation status was an independent predictor of tamponade. Case complexity is highly variable and requires skilled operators with a multi-disciplinary approach to achieve good outcomes.


  • Open Access

    Local catheter impedance drop during pulmonary vein isolation predicts acute conduction block in patients with paroxysmal atrial fibrillation: initial results of the LOCALIZE clinical trial

    by Moloy Das, Armin Luik, Ewen Shepherd, Matthew Sulkin, Jacob Laughner, Tobias Oesterlein, Elizabeth Duffy, Christian Meyer, Pierre Jais, Josselin Duchateau, et al.

    Radiofrequency ablation creates irreversible cardiac damage through resistive heating and this temperature change results in a generator impedance drop. Evaluation of a novel local impedance (LI) technology measured exclusively at the tip of the ablation catheter found that larger LI drops were indicative of more effective lesion formation. We aimed to evaluate whether LI drop is associated with conduction block in patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein isolation (PVI). Sixty patients underwent LI-blinded de novo PVI using a point-by-point ablation workflow. Pulmonary vein rings were divided into 16 anatomical segments. After a 20-min waiting period, gaps were identified on electroanatomic maps. Median LI drop within segments with inter-lesion distance ≤6 mm was calculated offline. The diagnostic accuracy of LI drop for predicting segment block was assessed using receiver operating characteristic analysis. For segments with inter-lesion distance ≤6 mm, acutely blocked segments had a significantly larger LI drop [19.8 (14.1–27.1) Ω] compared with segments with gaps [10.6 (7.8–14.7) Ω, P < 0.001). In view of left atrial wall thickness differences, the association between LI drop and block was further evaluated for anterior/roof and posterior/inferior segments. The optimal LI cut-off value for anterior/roof segments was 16.1 Ω (positive predictive value for block: 96.3%) and for posterior/inferior segments was 12.3 Ω (positive predictive value for block: 98.1%) where inter-lesion distances were ≤6 mm. The magnitude of LI drop was predictive of acute PVI segment conduction block in patients with paroxysmal AF. The thinner posterior wall required smaller LI drops for block compared with the thicker anterior wall.


  • Open Access

    Two zebras and a cardiac arrest: a case report of concomitant Brugada syndrome and an anomalous coronary artery

    by Alexander Bates, Waqas Ullah, James Wilkinson, James Shambrook

    Background: Discovering concomitant diagnoses results in a challenge to determine the true cause of a patient’s presentation. Evaluating this fully is vital to plan appropriate and avoid inappropriate therapy. Case summary: A 55-year-old gentleman presents in cardiac arrest whilst watching an unusual occurrence of England dominating a Football World Cup game vs. Panama in 2018. Diagnostic coronary angiography discovered an anomalous right coronary artery from the opposite sinus (R-ACAOS), but clinical suspicion this was incidental lead to a further diagnosis of Type 1 Brugada Syndrome (BrS) following a positive Ajmaline provocation challenge. Risk stratification of these two zebras using computed tomography coronary angiography (CTCA), Cardiac magnetic resonance imaging (CMRI), Exercise Stress Echocardiography was performed and following a multi-disciplinary meeting, BrS was felt to be the primary diagnosis. The patient received a secondary prevention implantation of a cardiac defibrillator and avoided cardiac surgery. Discussion: Diagnosing a rare condition does not necessarily mean it is the cause of a patient’s presentation and should not end the investigative process. Right coronary artery from the opposite sinus rarely causes cardiac arrest in middle age and is typically associated with peak exercise. Type 1 BrS is associated with cardiac arrest with vagal activity, perhaps such as England winning a World Cup game! Clinical correlation and risk stratification is required for suspected incidental findings.


  • UK multicenter retrospective comparison of novel active versus conventional passive fixation coronary sinus leads

    by Dimitrios Gerontitis, Ihab Diab, Anthony W. C. Chow, Ross J. Hunter, Francisco Leyva, Andrew J. Turley, Ian Williams, Waqas Ullah, other members of the Attain Stability Study Group/Consortium

    Background: A novel active fixation coronary sinus (CS) lead, Attain Stability (AS), has been released aiming to improve targeted lead positioning. Rather than being wedged into the distal vessel, it relies on a side helix for fixation. We aimed to compare implant procedure parameters and electromechanical stability of the AS lead with passive CS leads.Methods: A retrospective study involving six major UK cardiac centers. Patients who received active fixation leads were compared with passive fixation lead recipients in a 1:2 ratio. The primary outcome was total lead displacements (combined macrodisplacement/microdisplacement, defined as displacements requiring repositioning procedures, an increase in threshold ≥0.5 V or pulse width ≥0.5 ms, or a change in pacing polarity).Results: A total of 761 patients were included (253 AS leads and 508 passive fixation leads), of which 736 had follow‐up data. The primary endpoint rate was 31% (75/241) in the active and 43% (214/495) in the passive group (p = .002). Six patients (2.5%) in the active group and 14 patients (2.8%) in the passive group required CS lead repositioning procedures (p = 0.981). On multivariable analysis, active leads were associated with a reduction in lead displacements, odds ratio 0.66 (95% confidence interval: 0.46–0.95), p = .024. There were differences in favor of passive leads in procedure duration, 120 (96–149) versus 127 (105–155) min (p = .008), and fluoroscopy time, 17 (11–26) versus 18.5 (13–27) min (p = .0022). The median follow‐up duration was similar (active vs. passive): 31 (17–47) versus 34 (16–71) weeks, (p = .052).Conclusion: AS CS leads had improved electromechanical stability compared with passive fixation leads, with only minimal increases in implant procedure and fluoroscopy times.


  • Ablation Index and Surround Flow Catheter Irrigation

    by Waqas Ullah, Ross J. Hunter, Malcolm C. Finlay, Ailsa McLean, Mehul B. Dhinoja, Simon Sporton, Mark J. Earley, Richard J. Schilling