Ilker Hacihaliloglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ilker Hacihaliloglu has a total of 141 co-authors. Here are the top co-authors by number of shared publications:
Rafeef Abugharbieh
Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia, Canada
10 shared publicationsJohn L. Nosher
The University of British Columbia
9 shared publicationsRobert N. Rohling
University of British Columbia
9 shared publicationsAbtin Rasoulian
The University of British Columbia
7 shared publications- Pierre Guy
Division of Orthopedic Trauma, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada
7 shared publications - Cosmas Mwikirize
Department of Electrical and Computer Engineering, Makerere University, Kampala, Uganda
6 shared publications
Latest Publications
- 1 September 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (05) , 1-14
Incorporating synthetic data from diffusion models supports echocardiography downstream tasks
PurposeLarge labeled echocardiography datasets are costly to collect. We use diffusion models to generate synthetic training data for segmentation and cardiac phase classification.ApproachWe study three generation approaches on CAMUS: an unconditional image space model, a latent model conditioned on plain English prompts or abstract tokens, and a ControlNet model conditioned on an abstract token and segmentation mask. We evaluate synthesis with Fréchet inception distance (FID) and augmentation using segmentation and classification of end diastole and end systole. We also evaluate segmentation within CardiacUDC and directly from CAMUS to CardiacUDC.ResultsConditioning on an abstract token and segmentation mask gives the lowest mean FID, 1.5, compared with 3.2 for the semantic diffusion model. Abstract token augmentation gives the highest classification accuracy, improving ResNet-18 from 83.8% to 87.2% and VGG-16 from 74.5% to 78.7%. Synthetic augmentation gives the highest mean Dice of 87.6% for the CAMUS 2D U-Net and 84.6% for the CardiacUDC nnU-Net. When nnU-Net models are trained on CAMUS and evaluated directly on CardiacUDC, augmentation raises mean Dice from 74.6% to 75.2%.ConclusionsIncorporating synthetic images into training gives modest gains in CAMUS phase classification, segmentation within CAMUS and CardiacUDC, and direct segmentation from CAMUS to CardiacUDC.
- 1 September 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (05) , 1-14
Incorporating synthetic data from diffusion models supports echocardiography downstream tasks
PurposeLarge labeled echocardiography datasets are costly to collect. We use diffusion models to generate synthetic training data for segmentation and cardiac phase classification.ApproachWe study three generation approaches on CAMUS: an unconditional image space model, a latent model conditioned on plain English prompts or abstract tokens, and a ControlNet model conditioned on an abstract token and segmentation mask. We evaluate synthesis with Fréchet inception distance (FID) and augmentation using segmentation and classification of end diastole and end systole. We also evaluate segmentation within CardiacUDC and directly from CAMUS to CardiacUDC.ResultsConditioning on an abstract token and segmentation mask gives the lowest mean FID, 1.5, compared with 3.2 for the semantic diffusion model. Abstract token augmentation gives the highest classification accuracy, improving ResNet-18 from 83.8% to 87.2% and VGG-16 from 74.5% to 78.7%. Synthetic augmentation gives the highest mean Dice of 87.6% for the CAMUS 2D U-Net and 84.6% for the CardiacUDC nnU-Net. When nnU-Net models are trained on CAMUS and evaluated directly on CardiacUDC, augmentation raises mean Dice from 74.6% to 75.2%.ConclusionsIncorporating synthetic images into training gives modest gains in CAMUS phase classification, segmentation within CAMUS and CardiacUDC, and direct segmentation from CAMUS to CardiacUDC.
- 10 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. PP (00189294) , 1-13
Robust Semi-Supervised CT Radiomics for Lung Cancer Prognosis: Cost-Effective Learning with Limited Labels and SHAP Interpretation
Objective: Computed tomography (CT) imaging is essential for lung cancer (LCa) management, while offering detailed visualization and valuable information for Artificial Intelligence-guided prognosis. Meanwhile, supervised learning (SL) models require extensive labeled data, limiting their real-world utility where annotations are scarce. Methods: We analyzed CT scans from 977 patients across 12 public/private datasets, extracting 1,218 radiomics features using Laplacian of Gaussian and wavelet filters via standardized PyRadiomics. Dimensionality was reduced using 56 feature selection and attribute extraction algorithms, and 27 classifiers were benchmarked. Semi-supervised learning (SSL) framework with pseudo-labeling utilized 478 unlabeled and 499 labeled cases. Model sensitivity was assessed in three scenarios: varying labeled data in SL, increasing unlabeled data in SSL, and jointly scaling both from 10% to 100%. SHapley Additive exPlanations analysis (SHAP)analysis explained and interpreted the top model predictions. Five-fold cross-validation and external testing (in two cohorts) were performed. Results: SSL outperformed SL across all metrics, improving overall survival prediction by up to 17%. The top SSL model (Feature Importance by Random Forest+XGBoost) achieved 0.90±0.01 accuracy in cross-validation and 0.88±0.01 externally. SHAP revealed enhanced feature discriminability in SSL and SL, particularly for class 1 (survival>4 years), and helped explain model decisions. SSL maintained strong performance even with only 10% labeled data. Both SSL-based scenarios demonstrated more stable performance compared to SL, with lower variance across external testing, emphasizing SSL's robustness and cost-efficiency. Conclusion: We propose an interpretable, cost-effective SSL framework for CT-based LCa survival prediction. Significance: It improves performance, generalizability, and clinical readiness via SHAP explainability and unlabeled data utilization.
- 10 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. PP (00189294) , 1-13
Robust Semi-Supervised CT Radiomics for Lung Cancer Prognosis: Cost-Effective Learning with Limited Labels and SHAP Interpretation
Objective: Computed tomography (CT) imaging is essential for lung cancer (LCa) management, while offering detailed visualization and valuable information for Artificial Intelligence-guided prognosis. Meanwhile, supervised learning (SL) models require extensive labeled data, limiting their real-world utility where annotations are scarce. Methods: We analyzed CT scans from 977 patients across 12 public/private datasets, extracting 1,218 radiomics features using Laplacian of Gaussian and wavelet filters via standardized PyRadiomics. Dimensionality was reduced using 56 feature selection and attribute extraction algorithms, and 27 classifiers were benchmarked. Semi-supervised learning (SSL) framework with pseudo-labeling utilized 478 unlabeled and 499 labeled cases. Model sensitivity was assessed in three scenarios: varying labeled data in SL, increasing unlabeled data in SSL, and jointly scaling both from 10% to 100%. SHapley Additive exPlanations analysis (SHAP)analysis explained and interpreted the top model predictions. Five-fold cross-validation and external testing (in two cohorts) were performed. Results: SSL outperformed SL across all metrics, improving overall survival prediction by up to 17%. The top SSL model (Feature Importance by Random Forest+XGBoost) achieved 0.90±0.01 accuracy in cross-validation and 0.88±0.01 externally. SHAP revealed enhanced feature discriminability in SSL and SL, particularly for class 1 (survival>4 years), and helped explain model decisions. SSL maintained strong performance even with only 10% labeled data. Both SSL-based scenarios demonstrated more stable performance compared to SL, with lower variance across external testing, emphasizing SSL's robustness and cost-efficiency. Conclusion: We propose an interpretable, cost-effective SSL framework for CT-based LCa survival prediction. Significance: It improves performance, generalizability, and clinical readiness via SHAP explainability and unlabeled data utilization.
- Open Access
- 14 January 2026
- Published by Elsevier in Mayo Clinic Proceedings: Innovations, Quality & Outcomes
- Vol. 10 (1) , 100691
Multifeature Ultrasound-Based Classification for Breast Lesions: A Comparative Study of PONS Image Enhancement Technology
- 14 January 2026
- Published by Elsevier in Mayo Clinic Proceedings: Innovations, Quality & Outcomes
- Vol. 10 (1) , 100691
Open AccessMultifeature Ultrasound-Based Classification for Breast Lesions: A Comparative Study of PONS Image Enhancement Technology
- Open Access
- 9 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2)
Radiological and biological dictionary of radiomics features: addressing understandable AI issues in personalized breast cancer; dictionary version BM1.0
Objective: Radiomics-based AI models show potential in breast cancer diagnosis but lack interpretability. This study bridges the gap between radiomic features (RF) and BI-RADS descriptors through a clinically interpretable framework. Methods: We developed a dual-dictionary approach. First, a Clinical Mapping Dictionary (CMD) was constructed by mapping 56 RFs to BI-RADS descriptors (shape, margin, internal enhancement) based on literature and expert review. Second, we applied this framework to a classification task to predict triple-negative (TNBC) versus non-TNBC subtypes using Dynamic Contrast-Enhanced MRI data from a multi-institutional cohort of 1,549 patients. We trained 27 machine learning classifiers with 27 feature selection methods. Using SHapley Additive exPlanations (SHAP), we interpreted the model's predictions and developed a Statistical Mapping Dictionary (SMD) for 51 RFs, not included in the CMD. Results: The best-performing model (Variance Inflation Factor feature selector+Extra Trees Classifier) achieved an average cross-validation accuracy of 0.83±0.02. Our dual-dictionary approach successfully translated predictive RFs into understandable clinical concepts. For example, higher values of 'Sphericity', corresponding to a round/oval shape, were predictive of TNBC. Similarly, lower values of 'Busyness', indicating more homogeneous internal enhancement, were also associated with TNBC, aligning with existing clinical observations. This framework confirmed known imaging biomarkers and identified novel, data-driven quantitative features. Conclusion: This study introduces a novel dual-dictionary framework (BM1.0) that bridges RFs and the BI-RADS clinical lexicon. By enhancing the interpretability and transparency of AI models, the framework supports greater clinical trust and paves the way for integrating RFs into breast cancer diagnosis and personalized care.
- 9 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2)
Open AccessRadiological and biological dictionary of radiomics features: addressing understandable AI issues in personalized breast cancer; dictionary version BM1.0
Objective: Radiomics-based AI models show potential in breast cancer diagnosis but lack interpretability. This study bridges the gap between radiomic features (RF) and BI-RADS descriptors through a clinically interpretable framework. Methods: We developed a dual-dictionary approach. First, a Clinical Mapping Dictionary (CMD) was constructed by mapping 56 RFs to BI-RADS descriptors (shape, margin, internal enhancement) based on literature and expert review. Second, we applied this framework to a classification task to predict triple-negative (TNBC) versus non-TNBC subtypes using Dynamic Contrast-Enhanced MRI data from a multi-institutional cohort of 1,549 patients. We trained 27 machine learning classifiers with 27 feature selection methods. Using SHapley Additive exPlanations (SHAP), we interpreted the model's predictions and developed a Statistical Mapping Dictionary (SMD) for 51 RFs, not included in the CMD. Results: The best-performing model (Variance Inflation Factor feature selector+Extra Trees Classifier) achieved an average cross-validation accuracy of 0.83±0.02. Our dual-dictionary approach successfully translated predictive RFs into understandable clinical concepts. For example, higher values of 'Sphericity', corresponding to a round/oval shape, were predictive of TNBC. Similarly, lower values of 'Busyness', indicating more homogeneous internal enhancement, were also associated with TNBC, aligning with existing clinical observations. This framework confirmed known imaging biomarkers and identified novel, data-driven quantitative features. Conclusion: This study introduces a novel dual-dictionary framework (BM1.0) that bridges RFs and the BI-RADS clinical lexicon. By enhancing the interpretability and transparency of AI models, the framework supports greater clinical trust and paves the way for integrating RFs into breast cancer diagnosis and personalized care.
- 20 September 2025
- Published by Springer Nature
- p. 216-226
Flow Matching for Medical Image Synthesis: Bridging the Gap Between Speed and Quality
- 20 September 2025
- Published by Springer Nature
- p. 216-226
Flow Matching for Medical Image Synthesis: Bridging the Gap Between Speed and Quality
- 1 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (7) , 906-919
Synthetic Versus Classic Data Augmentation: Impacts on Breast Ultrasound Image Classification
The effectiveness of Deep Neural Networks (DNNs) for ultrasound image analysis depends on the availability and accuracy of training data. However, large-scale data collection and annotation, particularly in medical fields, is often costly and time-consuming, especially when healthcare professionals are already burdened with their clinical responsibilities. Ensuring that a model remains robust across different imaging conditions—such as variations in ultrasound devices and manual transducer operation—is crucial in ultrasound image analysis. Data augmentation is a widely used solution, as it increases both the size and diversity of datasets, thereby enhancing the generalization performance of DNNs. With the advent of generative networks like Generative Adversarial Networks (GAN) and diffusion-based models, synthetic data generation has emerged as a promising augmentation technique. However, comprehensive studies comparing classic and generative method-based augmentation methods are lacking, particularly in ultrasound-based breast cancer imaging, where variability in breast density, tumor morphology, and operator skill poses significant challenges. This study aims to compare the effectiveness of classic and generative network-based data augmentation techniques in improving the performance and robustness of breast ultrasound image classification models. Specifically, we seek to determine whether the computational intensity of generative networks is justified in data augmentation. This analysis will provide valuable insights into the role and benefits of each technique in enhancing diagnostic accuracy of DNN for breast cancer diagnosis. The code for this work will be available at https://github.com/yasamin-med/SCDA.git.
- 1 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (7) , 906-919
Synthetic Versus Classic Data Augmentation: Impacts on Breast Ultrasound Image Classification
The effectiveness of Deep Neural Networks (DNNs) for ultrasound image analysis depends on the availability and accuracy of training data. However, large-scale data collection and annotation, particularly in medical fields, is often costly and time-consuming, especially when healthcare professionals are already burdened with their clinical responsibilities. Ensuring that a model remains robust across different imaging conditions—such as variations in ultrasound devices and manual transducer operation—is crucial in ultrasound image analysis. Data augmentation is a widely used solution, as it increases both the size and diversity of datasets, thereby enhancing the generalization performance of DNNs. With the advent of generative networks like Generative Adversarial Networks (GAN) and diffusion-based models, synthetic data generation has emerged as a promising augmentation technique. However, comprehensive studies comparing classic and generative method-based augmentation methods are lacking, particularly in ultrasound-based breast cancer imaging, where variability in breast density, tumor morphology, and operator skill poses significant challenges. This study aims to compare the effectiveness of classic and generative network-based data augmentation techniques in improving the performance and robustness of breast ultrasound image classification models. Specifically, we seek to determine whether the computational intensity of generative networks is justified in data augmentation. This analysis will provide valuable insights into the role and benefits of each technique in enhancing diagnostic accuracy of DNN for breast cancer diagnosis. The code for this work will be available at https://github.com/yasamin-med/SCDA.git.
- Top Cited PapersOpen Access
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 47217-47229
Machine Learning Evaluation Metric Discrepancies Across Programming Languages and Their Components in Medical Imaging Domains: Need for Standardization
This study evaluates metrics for tasks such as classification, regression, clustering, correlation analysis, statistical tests, segmentation, and image-to-image (I2I) translation in medical imaging domains. Metrics were compared across Python libraries, R packages, and Matlab functions to assess their consistency and highlight discrepancies. The findings underscore the need for a unified roadmap to standardize metrics, ensuring reliable and reproducible ML evaluations across platforms. This study examined a wide range of evaluation metrics across various tasks in medical imaging and found only some to be consistent across platforms, such as Accuracy, Balanced Accuracy, Cohens Kappa, F-beta Score, MCC, Geometric Mean, AUC, and Log Loss in binary classification; Accuracy, Cohens Kappa, and F-beta Score in multi-class classification; MAE, MSE, RMSE, MAPE, Explained Variance, Median AE, MSLE, and Huber in regression; Davies-Bouldin Index and Calinski-Harabasz Index in clustering; Pearson, Spearman, Kendall’s Tau, Mutual Information, Distance Correlation, Bicor, Percbend, Shepherd, and Partial Correlation in correlation analysis; Paired t-test, Chi-Square Test, ANOVA, Kruskal-Wallis Test, Shapiro-Wilk Test, Welch’s t-test, and Bartlett’s test in statistical tests; Accuracy, Precision, and Recall in 2D segmentation; Accuracy in 3D segmentation; MAE, MSE, RMSE, and R-Squared in 2D-I2I translation; and MAE, MSE, and RMSE in 3D-I2I translation. Given observation of discrepancies in a number of metrics (e.g. precision, recall and F1 score in binary classification, WCSS in clustering, and multiple statistical tests, amongst multiple metrics), this study concludes that ML evaluation metrics require standardization and recommends that future research use consistent metrics for different tasks to effectively compare ML techniques and solutions.
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 47217-47229
Top Cited PapersOpen AccessMachine Learning Evaluation Metric Discrepancies Across Programming Languages and Their Components in Medical Imaging Domains: Need for Standardization
This study evaluates metrics for tasks such as classification, regression, clustering, correlation analysis, statistical tests, segmentation, and image-to-image (I2I) translation in medical imaging domains. Metrics were compared across Python libraries, R packages, and Matlab functions to assess their consistency and highlight discrepancies. The findings underscore the need for a unified roadmap to standardize metrics, ensuring reliable and reproducible ML evaluations across platforms. This study examined a wide range of evaluation metrics across various tasks in medical imaging and found only some to be consistent across platforms, such as Accuracy, Balanced Accuracy, Cohens Kappa, F-beta Score, MCC, Geometric Mean, AUC, and Log Loss in binary classification; Accuracy, Cohens Kappa, and F-beta Score in multi-class classification; MAE, MSE, RMSE, MAPE, Explained Variance, Median AE, MSLE, and Huber in regression; Davies-Bouldin Index and Calinski-Harabasz Index in clustering; Pearson, Spearman, Kendall’s Tau, Mutual Information, Distance Correlation, Bicor, Percbend, Shepherd, and Partial Correlation in correlation analysis; Paired t-test, Chi-Square Test, ANOVA, Kruskal-Wallis Test, Shapiro-Wilk Test, Welch’s t-test, and Bartlett’s test in statistical tests; Accuracy, Precision, and Recall in 2D segmentation; Accuracy in 3D segmentation; MAE, MSE, RMSE, and R-Squared in 2D-I2I translation; and MAE, MSE, and RMSE in 3D-I2I translation. Given observation of discrepancies in a number of metrics (e.g. precision, recall and F1 score in binary classification, WCSS in clustering, and multiple statistical tests, amongst multiple metrics), this study concludes that ML evaluation metrics require standardization and recommends that future research use consistent metrics for different tasks to effectively compare ML techniques and solutions.
- 29 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (9) , 905-908
Guest Editorial A Glimpse Into the Cutting Edge of Interventional Ultrasound
Breakthroughs in deep learning (DL), artificial intelligence (AI), point-of-care ultrasound (POCUS), and medical robotics have set off an exciting era in interventional ultrasound. Advances in DL and AI have enabled better and faster-than-ever extraction of information from ultrasound data. POCUS is becoming increasingly popular due to its cost-effectiveness, improved image quality, and ease of use. In addition, manufacturers have moved away from analog beamforming to digital beamforming, which provides researchers with access to raw data which is usually more information-rich than beamformed B-mode images. Concurrently, medical robotics is becoming ever more established in its traditional application and is further finding new, emerging clinical applications. The Guest Editors are delighted to present 14 papers in this Spotlight Issue on Interventional Ultrasound.
- 29 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (9) , 905-908
Guest Editorial A Glimpse Into the Cutting Edge of Interventional Ultrasound
Breakthroughs in deep learning (DL), artificial intelligence (AI), point-of-care ultrasound (POCUS), and medical robotics have set off an exciting era in interventional ultrasound. Advances in DL and AI have enabled better and faster-than-ever extraction of information from ultrasound data. POCUS is becoming increasingly popular due to its cost-effectiveness, improved image quality, and ease of use. In addition, manufacturers have moved away from analog beamforming to digital beamforming, which provides researchers with access to raw data which is usually more information-rich than beamformed B-mode images. Concurrently, medical robotics is becoming ever more established in its traditional application and is further finding new, emerging clinical applications. The Guest Editors are delighted to present 14 papers in this Spotlight Issue on Interventional Ultrasound.