Latest Publications

  • Open Access

    Comparative validation of speckle contrast optical spectroscopy against diffuse correlation spectroscopy for monitoring human cerebral blood flow

    by Tom Y. Cheng, Mitchell B. Robinson, Marco Renna, Kuan-Cheng Wu, Zachary Starkweather, Olivia S. Kierul, Byungchan (Kenny) Kim, Alexander C. Howard, David A. Boas, Stefan A. Carp, et al.

    SignificanceWithin diffuse optics, speckle contrast optical spectroscopy (SCOS) has emerged as a promising alternative to the state-of-the-art technique of diffuse correlation spectroscopy (DCS) for continuous, noninvasive bedside monitoring of cerebral blood flow (CBF). Although the two methods theoretically yield equivalent relative indices of CBF (rCBFi), in practice, SCOS-based measurements require experimental calibration to obtain unbiased rCBFi values. To date, there are limited validation studies comparing SCOS and DCS in human subjects, particularly at long source–detector separations (SDS) relevant to adult brain monitoring.AimWe aim to compare rCBFi from SCOS and DCS during concurrent, colocalized measurements on tissue-mimicking phantoms and humans at a large SDS of 3 cm.ApproachWe conducted concurrent SCOS and DCS measurements on temperature-ramped, two-layer, and flow phantoms, respectively. We also conducted concurrent CBF measurements on 10 healthy volunteers undergoing various physiological challenges (breath-holding, hyperventilation, pressure modulation, and squatting) designed to elicit measurable changes in blood flow. SCOS and DCS operated from a shared pulsed laser source, which enabled pulsation-resolved human CBF measurements at 3 cm SDS (DCS necessitated the use of cardiac-gated averaging).ResultsWe observed strong agreement (r=0.93, slope = 0.98) between SCOS- and DCS-derived rCBFi at 3 cm SDS and an order-of-magnitude improvement in SCOS noise performance relative to DCS during the in vivo measurements. Phantom experiments showed a small depth-sensitivity disadvantage for SCOS at the same SDS; however, this was far outweighed by its superior noise performance, yielding an order-of-magnitude improvement in SCOS contrast-to-noise ratio.ConclusionsThe results demonstrate the equivalence of properly calibrated SCOS and DCS rCBFi measurements at long SDS in adults, establishing SCOS as a viable alternative to DCS for monitoring CBF. Further validation across larger cohorts and clinical populations is warranted.


  • Open Access

    Temporal dissociation between cerebral blood flow and brain tissue oxygenation during CPR: observations from a porcine model

    by Michael G. Silverman, Ki Tae Jung, Stefan A. Carp, Bryce Carr, Ailis C. Muldoon, Bonsung Koo, Dibbyan Mazumder, Ekaterina Creed, Kichang Lee

  • Long-Term Continuous Monitoring of Aneurysmal Subarachnoid Hemorrhage Using Diffuse Correlation Spectroscopy

    by Ailis Muldoon, Mitchell B. Robinson, Shakeeb Habash, John Sunwoo, Justin Gelman, Andrew Webb, Eric Rosenthal, Maria Angela Franceschini, David Y. Chung, Stefan A. Carp

    We present data from long-term continuous optical monitoring of patients with SAH. We show, that systemic blood pressure is not a suitable surrogate marker for brain blood flow and that CrCP shows agreement with ICP.

  • Pathlength-Selective, Interferometric Diffuse Correlation Spectroscopy

    by Mitchell B. Robinson, Marco Renna, Nikola Otic, Olivia S. Kierul, Ailis Muldoon, Maria Angela Franceschini, Stefan A. Carp

    In this work, we present an enhanced diffuse correlation spectroscopy (DCS) method called pathlength-selective, interferometric DCS (PaLS-iDCS), which uses pathlength-specific coherent gain to improve both the sensitivity to deep tissue hemodynamics and measurement SNR. Through interferometric detection, PaLS-iDCS can provide time-of-flight (ToF) specific blood flow information without the use of expensive time-tagging electronics and low-jitter detectors. The technique is compared to time-domain DCS (TD-DCS), another enhanced DCS method able to resolve photon ToF in tissue, through Monte Carlo simulation, phantom experiments, and human subject measurements. PaLS-iDCS consistently demonstrates improvements in SNR (>2x) for similar measurement conditions (same photon ToF), and the SNR improvements allow for measurements at extended photon ToFs, which have increased sensitivity to deep tissue hemodynamics (~50% increase). Further, like TD-DCS, PaLS-iDCS allows direct estimation of tissue optical properties from the sampled ToF distribution. This method offers a relatively straightforward way to allow DCS systems to make robust measurements of blood flow with greatly enhanced sensitivity to deep tissue hemodynamics without the need for time-resolved detection, enabling further applications of this non-invasive technology.


  • Open Access

    The fNIRS glossary project: a consensus-based resource for functional near-infrared spectroscopy terminology

    by Katharina Stute, Louisa Gossé, Samuel Montero-Hernandez, Guy A. Perkins, Meryem A. Yücel, Simone Cutini, Turgut Durduran, Ann-Christine Ehlis, Marco Ferrari, Judit Gervain, et al.

    SignificanceA shared understanding of terminology is essential for clear scientific communication and minimizing misconceptions. This is particularly challenging in rapidly expanding, interdisciplinary domains that utilize functional near-infrared spectroscopy (fNIRS), where researchers come from diverse backgrounds and apply their expertise in fields such as engineering, neuroscience, and psychology.AimThe fNIRS Glossary Project was established to develop a community-sourced glossary covering key fNIRS terms, including those related to the continuous-wave (CW), frequency-domain (FD), and time-domain (TD) NIRS techniques.ApproachThe glossary was collaboratively developed by a diverse group of 76 fNIRS researchers, representing a wide range of career stages (from PhD students to experts) and disciplines. This collaborative process, structured across five phases, ensured the glossary’s depth and comprehensiveness.ResultsThe glossary features over 300 terms categorized into six key domains: analysis, experimental design, hardware, neuroscience, mathematics, and physics. It also includes abbreviations, symbols, synonyms, references, alternative definitions, and figures where relevant.ConclusionsThe fNIRS glossary provides a community-sourced resource that facilitates education and effective scientific communication within the fNIRS community and related fields. By lowering barriers to learning and engaging with fNIRS, the glossary is poised to benefit a broad spectrum of researchers, including those with limited access to educational resources.


  • Open Access

    Flexible circuit-based spatially aware modular optical brain imaging system for high-density measurements in natural settings

    by Edward Xu, Morris Vanegas, Miguel Mireles, Artem Dementyev, Ashlyn McCann, Meryem Yücel, Stefan Carp, Qianqian Fang

    SignificanceFunctional near-infrared spectroscopy (fNIRS) presents an opportunity to study human brains in everyday activities and environments. However, achieving robust measurements under such dynamic conditions remains a significant challenge.AimThe modular optical brain imaging (MOBI) system is designed to enhance optode-to-scalp coupling and provide a real-time probe three-dimensional (3D) shape estimation to improve the use of fNIRS in everyday conditions.ApproachThe MOBI system utilizes a bendable and lightweight modular circuit-board design to enhance probe conformity to head surfaces and comfort for long-term wearability. Combined with automatic module connection recognition, the built-in orientation sensors on each module can be used to estimate optode 3D positions in real time to enable advanced tomographic data analysis and motion tracking.ResultsOptical characterization of the MOBI detector reports a noise equivalence power of 8.9 and 7.3 pW/Hz at 735 and 850 nm, respectively, with a dynamic range of 88 dB. The 3D optode shape acquisition yields an average error of 4.2 mm across 25 optodes in a phantom test compared with positions acquired from a digitizer. Results for initial in vivo validations, including a cuff occlusion and a finger-tapping test, are also provided.ConclusionsTo the best of our knowledge, the MOBI system is the first modular fNIRS system featuring fully flexible circuit boards. The self-organizing module sensor network and automatic 3D optode position acquisition, combined with lightweight modules (18 g/module) and ergonomic designs, would greatly aid emerging explorations of brain function in naturalistic settings.


  • Open Access

    Pathlength-selective, interferometric diffuse correlation spectroscopy

    by Mitchell B. Robinson, Marco Renna, Nikola Otic, Olivia S. Kierul, Ailis Muldoon, Maria Angela Franceschini, Stefan A. Carp

    Diffuse correlation spectroscopy (DCS) is an optical method that offers non-invasive assessment of blood flow in tissue through the analysis of intensity fluctuations in diffusely backscattered coherent light. The non-invasive nature of DCS has enabled several clinical application areas for deep tissue blood flow measurements, including neuromonitoring, cancer imaging, and exercise physiology. While promising, in measurement configurations targeting deep tissue hemodynamics, standard DCS implementations suffer from insufficient signal-to-noise ratio (SNR), depth sensitivity, and sampling rate, limiting their utility. In this work, we present an enhanced DCS method called pathlength-selective, interferometric DCS (PaLS-iDCS), which uses pathlength-specific coherent gain to improve both the sensitivity to deep tissue hemodynamics and measurement SNR. Through interferometric detection, PaLS-iDCS can provide time-of-flight (ToF) specific blood flow information without the use of expensive time-tagging electronics and low-jitter detectors. The technique is compared to time-domain DCS (TD-DCS), another enhanced DCS method able to resolve photon ToF in tissue, through Monte Carlo simulation, phantom experiments, and human subject measurements. PaLS-iDCS consistently demonstrates improvements in SNR (>2x) for similar measurement conditions (same photon ToF), and the SNR improvements allow for measurements at extended photon ToFs, which have increased sensitivity to deep tissue hemodynamics (∼50% increase). Further, like TD-DCS, PaLS-iDCS allows direct estimation of tissue optical properties from the sampled ToF distribution. This method offers a relatively straightforward way to allow DCS systems to make robust measurements of blood flow with greatly enhanced sensitivity to deep tissue hemodynamics without the need for time-resolved detection, enabling further applications of this non-invasive technology.


  • Open Access

    Functional hemodynamic imaging markers for the prediction of pathological outcomes in breast cancer patients treated with neoadjuvant chemotherapy

    by Bin Deng, Ailis Muldoon, Jayne A. Cormier, Nathaniel D. Mercaldo, Elizabeth Niehoff, Natalie Moffett, Mansi A. A. Saksena, Steven J. Isakoff, Stefan A. Carp

    SignificanceAchieving pathologic complete response (pCR) after neoadjuvant chemotherapy (NACT) is a significant predictor of increased likelihood of survival in breast cancer patients. Early prediction of pCR is of high clinical value as it could allow personalized adjustment of treatment regimens in non-responding patients for improved outcomes.AimWe aim to assess the association between hemoglobin-based functional imaging biomarkers derived from diffuse optical tomography (DOT) and the pathological outcome represented by pCR at different timepoints along the course of NACT.ApproachTwenty-two breast cancer patients undergoing NACT were enrolled in a multimodal DOT and X-ray digital breast tomosynthesis (DBT) imaging study in which their breasts were imaged at different compression levels. Logistic regressions were used to study the associations between DOT-derived imaging markers evaluated after the first and second cycles of chemotherapy, respectively, with pCR status determined after the conclusion of NACT at the time of surgery. Receiver operating characteristic curve analysis was also used to explore the predictive performance of selected DOT-derived markers.ResultsNormalized tumor HbT under half compression was significantly lower in the pCR group compared to the non-pCR group after two chemotherapy cycles (p=0.042). In addition, the change in normalized tumor StO2 upon reducing compression from full to half mammographic force was identified as another potential indicator of pCR at an earlier time point, i.e., after the first chemo cycle (p=0.038). Exploratory predictive assessments showed that AUCs using DOT-derived functional imaging markers as predictors reach as high as 0.75 and 0.71, respectively, after the first and second chemo cycle, compared to AUCs of 0.50 and 0.53 using changes in tumor size measured on DBT and MRI.ConclusionsThese findings suggest that breast DOT could be used to assist response assessment in women undergoing NACT, a critical but unmet clinical need, and potentially enable personalized adjustments of treatment regimens.


  • Open Access

    Flexible-circuit-based 3-D aware modular optical brain imaging system for high-density measurements in natural settings

    by Edward Xu, Morris Vanegas, Miguel Mireles, Artem Dementyev, Meryem Yücel, Stefan Carp, Qianqian Fang

    Significance: Functional near-infrared spectroscopy (fNIRS) presents an opportunity to study human brains in every-day activities and environments. However, achieving robust measurements under such dynamic condition remains a significant challenge. Aim: The modular optical brain imaging (MOBI) system is designed to enhance optode-to-scalp coupling and provide real-time probe 3-D shape estimation to improve the use of fNIRS in everyday conditions. Approach: The MOBI system utilizes a bendable and lightweight modular circuit-board design to enhance probe conformity to head surfaces and comfort for long-term wearability. Combined with automatic module connection recognition, the built-in orientation sensors on each module can be used to estimate optode 3-D positions in real-time to enable advanced tomographic data analysis and motion tracking. Results: Optical characterization of the MOBI detector reports a noise equivalence power (NEP) of 8.9 and 7.3 pW/ Hz at 735 nm and 850 nm, respectively, with a dynamic range of 88 dB. The 3-D optode shape acquisition yields an average error of 4.2 mm across 25 optodes in a phantom test compared to positions acquired from a digitizer. Results for initial in vivo validations, including a cuff occlusion and a finger-tapping test, are also provided. Conclusions: To the best of our knowledge, the MOBI system is the first modular fNIRS system featuring fully flexible circuit boards. The self-organizing module sensor network and automatic 3-D optode position acquisition, combined with lightweight modules (18 g/module) and ergonomic designs, would greatly aid emerging explorations of brain function in naturalistic settings.


  • Multi-wavelength multi-distance diffuse correlation spectroscopy system for assessment of premature infants’ cerebral hemodynamics

    by Nikola Otic, John Sunwoo, Yujing Huang, Alyssa Martin, Mitchell B. Robinson, Bernhard Zimmermann, Stefan Carp, Terrie Inder, Mohamed El-Dib, Maria Angela Franceschini, et al.

    Infants born at an extremely low gestational age (ELGA, < 29 weeks) are at an increased risk of intraventricular hemorrhage (IVH), and there is a need for standalone, safe, easy-to-use tools for monitoring cerebral hemodynamics. We have built a multi-wavelength multi-distance diffuse correlation spectroscopy device (MW-MD-DCS), which utilizes time-multiplexed, long-coherence lasers at 785, 808, and 853 nm, to simultaneously quantify the index of cerebral blood flow (CBFi) and the hemoglobin oxygen saturation (SO2). We show characterization data on liquid phantoms and demonstrate the system performance on the forearm of healthy adults, as well as clinical data obtained on two preterm infants.