Ivo Milton Raimundo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ivo Milton Raimundo has a total of 165 co-authors. Here are the top co-authors by number of shared publications:
- Celio Pasquini
Institute of Chemistry, State University of Campinas, Rua Monteiro Lobato, 290, 13083-862, Campinas, SP, Brazil
17 shared publications - Maria Fernanda Pimentel
Department of Chemical Engineering, Federal University of Pernambuco, Av. dos Economistas, Cidade Universitária, s/n, 50.740-590, Recife, PE, Brazil
10 shared publications - Boris Mizaikoff
Institute of Analytical and Bioanalytical Chemistry Ulm University Ulm Germany
7 shared publications - Alberto Nova Araújo
Associated Laboratory for Green Chemistry (LAQV), Network of Chemistry and Technology (REQUIMTE), Laboratory of Applied Chemistry, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, 4050-313 Porto, Portugal
6 shared publications Jarbas J. R. Rohwedder
Institute of Chemistry, University of Campinas, Campinas, Brazil
6 shared publicationsJarbas J.R. Rohwedder
Instituto de Química, UNICAMP, Cx Postal 6154, CEP 13084-971 Campinas, Brazil
6 shared publications
Latest Publications
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
A paper-based Raman spot test for sulfate determination
A paper-based substrate with a delimited analytical area was employed as a spot test platform for sulfate determination.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
A paper-based Raman spot test for sulfate determination
A paper-based substrate with a delimited analytical area was employed as a spot test platform for sulfate determination.
- 1 August 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (10) , 2682-2691
Evaluation of different types of paper as solid substrates and their effects on LIBS emission signals
Minor components and fillers of paper substrates can improve LIBS emission of metal ions, such as Cu( ii ) and Mn( ii ).
- 1 August 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (10) , 2682-2691
Evaluation of different types of paper as solid substrates and their effects on LIBS emission signals
Minor components and fillers of paper substrates can improve LIBS emission of metal ions, such as Cu( ii ) and Mn( ii ).
- 15 February 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (4) , 1024-1029
A solid substrate based on clay minerals for sampling organic liquids in molecular LIBS analysis
LIBS is an analytical technique for direct analysis, capable of performing elemental, molecular and isotopic characterization. This technique involves the physical processes of ablation and plasma formation by the incidence of high-energy laser pulses. The direct analysis of liquid samples is challenging due to the occurrence of splashes that impairs the measurement in many aspects. In this work, an inorganic solid substrate consisting of a bentonite/sepiolite composite (70/30 wt%) is described as a support for organic liquids in molecular LIBS analysis. The substrate allowed molecular LIBS measurements of solvents, fuels and even aqueous solution with minimal spectral interference and made it possible to identify molecular radical emissions (CN and C2). Therefore, the proposed substrate is believed to be an alternative material for sampling organic liquids for molecular LIBS analyses.
- 15 February 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (4) , 1024-1029
A solid substrate based on clay minerals for sampling organic liquids in molecular LIBS analysis
LIBS is an analytical technique for direct analysis, capable of performing elemental, molecular and isotopic characterization. This technique involves the physical processes of ablation and plasma formation by the incidence of high-energy laser pulses. The direct analysis of liquid samples is challenging due to the occurrence of splashes that impairs the measurement in many aspects. In this work, an inorganic solid substrate consisting of a bentonite/sepiolite composite (70/30 wt%) is described as a support for organic liquids in molecular LIBS analysis. The substrate allowed molecular LIBS measurements of solvents, fuels and even aqueous solution with minimal spectral interference and made it possible to identify molecular radical emissions (CN and C2). Therefore, the proposed substrate is believed to be an alternative material for sampling organic liquids for molecular LIBS analyses.
- 6 October 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (44) , 6000-6008
Underwater determination of calcium and strontium ions in oilfield produced water by laser-induced breakdown spectroscopy (LIBS)
Laser-induced breakdown spectroscopy (LIBS) was applied to the determination of scaling ions in oilfield-produced water employing underwater measurements. Initially, the stability of plasma was verified using four different optical setups and expansion of the laser beam, and a combination of an achromatic lens with a meniscus lens were necessary to stabilize the plasma. Preliminary experiments demonstrated that only the determinations of Ca(II) and Sr(II) ions were feasible while the signal for the Mg(II) ion was absent and the sensitivity for Ba(II) was very low. The laser pulse repetition rate was evaluated and rates of 10 and 20 Hz provided a more stable breakdown in water compared to repetition rates of 2 to 7 Hz, besides imparting higher intense signals. The increase in salinity showed a small matrix effect, decreasing the sensitivities of the calibration curves by 8–13% when standard solutions with a salinity of 30‰ were used instead of water. Under optimized conditions with a laser pulse energy of 31 mJ, gate delay of 300 ns, gate width of 5.0 μs, repetition rate of 10 Hz, and accumulation of 500 laser shots, a linear range from 25 to 150 mg L−1 was obtained, with limits of detection of 0.58 and 0.85 mg L−1 for Ca(II) and Sr(II), respectively. The underwater determination of scaling ions in produced water by LIBS provided results that do not significantly differ from those obtained by inductively coupled plasma atomic emission spectroscopy (ICP OES) at a confidence level of 95%, with relative errors of up to 5.2%. These results demonstrate the potential of underwater LIBS measurements as an analytical tool for the determination of alkaline-earth metal ions in produced water, which can help the oil industry to overcome the problems related to scale formation.
- 6 October 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (44) , 6000-6008
Underwater determination of calcium and strontium ions in oilfield produced water by laser-induced breakdown spectroscopy (LIBS)
Laser-induced breakdown spectroscopy (LIBS) was applied to the determination of scaling ions in oilfield-produced water employing underwater measurements. Initially, the stability of plasma was verified using four different optical setups and expansion of the laser beam, and a combination of an achromatic lens with a meniscus lens were necessary to stabilize the plasma. Preliminary experiments demonstrated that only the determinations of Ca(II) and Sr(II) ions were feasible while the signal for the Mg(II) ion was absent and the sensitivity for Ba(II) was very low. The laser pulse repetition rate was evaluated and rates of 10 and 20 Hz provided a more stable breakdown in water compared to repetition rates of 2 to 7 Hz, besides imparting higher intense signals. The increase in salinity showed a small matrix effect, decreasing the sensitivities of the calibration curves by 8–13% when standard solutions with a salinity of 30‰ were used instead of water. Under optimized conditions with a laser pulse energy of 31 mJ, gate delay of 300 ns, gate width of 5.0 μs, repetition rate of 10 Hz, and accumulation of 500 laser shots, a linear range from 25 to 150 mg L−1 was obtained, with limits of detection of 0.58 and 0.85 mg L−1 for Ca(II) and Sr(II), respectively. The underwater determination of scaling ions in produced water by LIBS provided results that do not significantly differ from those obtained by inductively coupled plasma atomic emission spectroscopy (ICP OES) at a confidence level of 95%, with relative errors of up to 5.2%. These results demonstrate the potential of underwater LIBS measurements as an analytical tool for the determination of alkaline-earth metal ions in produced water, which can help the oil industry to overcome the problems related to scale formation.
- 14 June 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (7) , 1450-1460
Determination of scaling ions in oilfield produced water by laser-induced breakdown spectroscopy
The deposition of inorganic scale in pipelines used in the exploration of oil on marine platforms caused by the precipitation of metal ions is one of the main causes for reduction in the production process of the oil industry. Therefore, a simple and efficient method for the determination of scaling ions in oilfield produced water using laser-induced breakdown spectroscopy (LIBS) was developed. Filter paper was used as a cellulosic solid substrate for phase conversion of Mg(II), Ca(II), Sr(II) and Ba(II) ions in saline medium. Instrumental parameters such as laser pulse energy, gate delay and gate width were evaluated along with sample preparation parameters, such as the type of cellulosic, polymeric or glass substrate, sample volume deposited on the substrate and the time required for drying, use of internal standards and effect of salinity. Energy-dispersive X-ray spectroscopy (EDS) analysis showed a homogeneous distribution of the analytes on the microfibers of the filter paper. The results indicated that salinity significantly affects the emission intensities of the analytes as well as the relative standard deviations, which ranged from 5.2 to 8.1% and 9.2 to 12.9% for samples prepared in water and in a solution with a salinity of 30‰, respectively. The spectral data were normalized using the C emission line (C I 247.88 nm) to minimize the matrix effect of the highly saline waters. Under optimized conditions and considering data without and with normalization, it was possible to obtain limits of detection ranging from 1.0 to 11.4 mg L−1, with a linear response range from 20 to 60 mg L−1 for Mg(II), Ca(II) and Sr(II) ions and from 40 to 80 mg L−1 for Ba(II) ions in aqueous solutions. The determination of scaling ions in produced water by LIBS showed that data normalization provides results that do not significantly differ from those obtained by inductively coupled plasma atomic emission spectroscopy (ICP OES) at a confidence level of 95%, demonstrating that the developed method has potential application to monitor the concentration of scaling ions in produced water, helping prevent scaling in the pipelines of oil platforms.
- 14 June 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (7) , 1450-1460
Determination of scaling ions in oilfield produced water by laser-induced breakdown spectroscopy
The deposition of inorganic scale in pipelines used in the exploration of oil on marine platforms caused by the precipitation of metal ions is one of the main causes for reduction in the production process of the oil industry. Therefore, a simple and efficient method for the determination of scaling ions in oilfield produced water using laser-induced breakdown spectroscopy (LIBS) was developed. Filter paper was used as a cellulosic solid substrate for phase conversion of Mg(II), Ca(II), Sr(II) and Ba(II) ions in saline medium. Instrumental parameters such as laser pulse energy, gate delay and gate width were evaluated along with sample preparation parameters, such as the type of cellulosic, polymeric or glass substrate, sample volume deposited on the substrate and the time required for drying, use of internal standards and effect of salinity. Energy-dispersive X-ray spectroscopy (EDS) analysis showed a homogeneous distribution of the analytes on the microfibers of the filter paper. The results indicated that salinity significantly affects the emission intensities of the analytes as well as the relative standard deviations, which ranged from 5.2 to 8.1% and 9.2 to 12.9% for samples prepared in water and in a solution with a salinity of 30‰, respectively. The spectral data were normalized using the C emission line (C I 247.88 nm) to minimize the matrix effect of the highly saline waters. Under optimized conditions and considering data without and with normalization, it was possible to obtain limits of detection ranging from 1.0 to 11.4 mg L−1, with a linear response range from 20 to 60 mg L−1 for Mg(II), Ca(II) and Sr(II) ions and from 40 to 80 mg L−1 for Ba(II) ions in aqueous solutions. The determination of scaling ions in produced water by LIBS showed that data normalization provides results that do not significantly differ from those obtained by inductively coupled plasma atomic emission spectroscopy (ICP OES) at a confidence level of 95%, demonstrating that the developed method has potential application to monitor the concentration of scaling ions in produced water, helping prevent scaling in the pipelines of oil platforms.
- 4 April 2023
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
- Vol. 10 (39) , 3-8
Professor Ivo M. Raimundo Jr., a researcher concerned about the current state of science in Brazil, kindly granted BrJAC an interview
Ivo M. Raimundo Jr. holds a degree in chemistry (1983), a master’s degree in chemistry (1989), and a doctorate in analytical chemistry (1995), all from the Institute of Chemistry, University of Campinas (IQ-Unicamp), Brazil. He carried out postdoctoral studies at the University of Manchester Institute of Science and Technology (UMIST), Manchester, England (1997/98), and the University of South Carolina, Columbia, USA (2017). He is currently Associate Professor at the Department of Analytical Chemistry at IQ - Unicamp. He was Associate Director (2006–2009) and Director (2009–2015) of the Pluridisciplinary Center for Chemical, Biological and Agricultural Research (CPQBA) at Unicamp, Secretary of the Brazilian Chemical Society, Campinas Regional (2020-2022) and is currently its treasurer. He has served as an Associate Editor of the Journal of the Brazilian Chemical Society since 2019. Prof. Raimundo Jr has experience in instrumentation and automation in analytical chemistry, working mainly in the following areas: optical (nano)sensors, microfabrication of analytical systems, and laser-induced breakdown spectroscopy (LIBS).
- 4 April 2023
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
- Vol. 10 (39) , 3-8
Professor Ivo M. Raimundo Jr., a researcher concerned about the current state of science in Brazil, kindly granted BrJAC an interview
Ivo M. Raimundo Jr. holds a degree in chemistry (1983), a master’s degree in chemistry (1989), and a doctorate in analytical chemistry (1995), all from the Institute of Chemistry, University of Campinas (IQ-Unicamp), Brazil. He carried out postdoctoral studies at the University of Manchester Institute of Science and Technology (UMIST), Manchester, England (1997/98), and the University of South Carolina, Columbia, USA (2017). He is currently Associate Professor at the Department of Analytical Chemistry at IQ - Unicamp. He was Associate Director (2006–2009) and Director (2009–2015) of the Pluridisciplinary Center for Chemical, Biological and Agricultural Research (CPQBA) at Unicamp, Secretary of the Brazilian Chemical Society, Campinas Regional (2020-2022) and is currently its treasurer. He has served as an Associate Editor of the Journal of the Brazilian Chemical Society since 2019. Prof. Raimundo Jr has experience in instrumentation and automation in analytical chemistry, working mainly in the following areas: optical (nano)sensors, microfabrication of analytical systems, and laser-induced breakdown spectroscopy (LIBS).
- 6 June 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (27) , 2657-2664
Analysis of sugars and sweeteners via terahertz time-domain spectroscopy
A THz-TDS spectrometer (terahertz time-domain spectroscopy) with ASOPS technology (asynchronous optical sampling) was employed in this study, aiming to explore the potential of the technique and to develop analytical applications for the identification of some saccharides. Analytical curves with linear responses were obtained in the saccharide concentration range from 1.7 to 11.7 (w/w). The characteristic peaks used for each sugar for univariate calibrations were fructose (1.704 THz), sucrose (1.827 THz), glucose (1.435 THz), lactose (1.373 THz), saccharin (2.664 THz), and sucralose (2.219 THz). Limits of detection around 1.0% (m/m) were obtained. Gaussian peak fitting was also employed as a tool to aid in the identification of saccharide components in mixtures and it was observed that the region between 0.5 and 2.0 THz is more adequate for such analysis since scattering is less evident. It was observed that in a mixture of sucrose, glucose and lactose (5% or 10% (m/m) each) in the range of 1.31 to 1.51 THz some sub-peaks of pure lactose and glucose can be identified.
- 6 June 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (27) , 2657-2664
Analysis of sugars and sweeteners via terahertz time-domain spectroscopy
A THz-TDS spectrometer (terahertz time-domain spectroscopy) with ASOPS technology (asynchronous optical sampling) was employed in this study, aiming to explore the potential of the technique and to develop analytical applications for the identification of some saccharides. Analytical curves with linear responses were obtained in the saccharide concentration range from 1.7 to 11.7 (w/w). The characteristic peaks used for each sugar for univariate calibrations were fructose (1.704 THz), sucrose (1.827 THz), glucose (1.435 THz), lactose (1.373 THz), saccharin (2.664 THz), and sucralose (2.219 THz). Limits of detection around 1.0% (m/m) were obtained. Gaussian peak fitting was also employed as a tool to aid in the identification of saccharide components in mixtures and it was observed that the region between 0.5 and 2.0 THz is more adequate for such analysis since scattering is less evident. It was observed that in a mixture of sucrose, glucose and lactose (5% or 10% (m/m) each) in the range of 1.31 to 1.51 THz some sub-peaks of pure lactose and glucose can be identified.
- 4 August 2021
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 75 (11) , 1374-1381
Detection of Low Lithium Concentrations Using Laser-Induced Breakdown Spectroscopy (LIBS) in High-Pressure and High-Flow Conditions
This paper describes the effects of laser pulse rate and solution flow rate on the determination of lithium at high pressure for water and 2.5% sodium chloride solutions using laser-induced breakdown spectroscopy (LIBS). Preliminary studies were performed with 0–40 mg L −1 Li solutions, at ambient pressure and at 210 bar, and in static and flowing (6 mL · min −1 ) regimes, for a combination of four different measurement conditions. The sensitivity of calibration curves depended on the pressure and the flow rate, as well as the laser pulse rate. The sensitivity of the calibration curve increased about 10% and 18% when the pressure was changed from 1 to 210 bar for static and flowing conditions, respectively. However, an effect of flow rate at high pressure for both 2 and 10 Hz laser pulse rates was observed. At ambient pressure, the effect of flow rate was negligible, as the sensitivity of the calibration curve decreased around 2%, while at high pressure the sensitivity increased around 4% when measurements were performed in a flow regime. Therefore, it seems there is a synergistic effect between pressure and flow rate, as the sensitivity increases significantly when both changes are considered. When the pulse rate is changed from 2 to 10 Hz, the sensitivity increases 26–31%, depending on the pressure and flow conditions. For lithium detection limit studies, performed with a laser pulse energy of 2.5 mJ, repetition rate of 10 Hz, gate delay of 500 ns, gate width of 1000 ns, and 1000 accumulations, a value around 40 µg L −1 was achieved for Li solutions in pure water for all four measurement conditions, while a detection limit of about 92 µg L −1 was determined for Li in 2.5% sodium chloride solutions, when high pressure and flowing conditions were employed. The results obtained in the present work demonstrate that LIBS is a powerful tool for the determination of Li in deep ocean conditions such as those found around hydrothermal vent systems.
- 4 August 2021
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 75 (11) , 1374-1381
Detection of Low Lithium Concentrations Using Laser-Induced Breakdown Spectroscopy (LIBS) in High-Pressure and High-Flow Conditions
This paper describes the effects of laser pulse rate and solution flow rate on the determination of lithium at high pressure for water and 2.5% sodium chloride solutions using laser-induced breakdown spectroscopy (LIBS). Preliminary studies were performed with 0–40 mg L −1 Li solutions, at ambient pressure and at 210 bar, and in static and flowing (6 mL · min −1 ) regimes, for a combination of four different measurement conditions. The sensitivity of calibration curves depended on the pressure and the flow rate, as well as the laser pulse rate. The sensitivity of the calibration curve increased about 10% and 18% when the pressure was changed from 1 to 210 bar for static and flowing conditions, respectively. However, an effect of flow rate at high pressure for both 2 and 10 Hz laser pulse rates was observed. At ambient pressure, the effect of flow rate was negligible, as the sensitivity of the calibration curve decreased around 2%, while at high pressure the sensitivity increased around 4% when measurements were performed in a flow regime. Therefore, it seems there is a synergistic effect between pressure and flow rate, as the sensitivity increases significantly when both changes are considered. When the pulse rate is changed from 2 to 10 Hz, the sensitivity increases 26–31%, depending on the pressure and flow conditions. For lithium detection limit studies, performed with a laser pulse energy of 2.5 mJ, repetition rate of 10 Hz, gate delay of 500 ns, gate width of 1000 ns, and 1000 accumulations, a value around 40 µg L −1 was achieved for Li solutions in pure water for all four measurement conditions, while a detection limit of about 92 µg L −1 was determined for Li in 2.5% sodium chloride solutions, when high pressure and flowing conditions were employed. The results obtained in the present work demonstrate that LIBS is a powerful tool for the determination of Li in deep ocean conditions such as those found around hydrothermal vent systems.
- Open Access
- 1 June 2021
- Published by IOP Publishing in Nano Express
- Vol. 2 (2) , 020022
PEG size effect and its interaction with Fe3O4 nanoparticles synthesized by solvothermal method: morphology and effect of pH on the stability
The synthesis and characterization of Fe3O4 magnetic nanoparticles (MNPs) obtained by the solvothermal method in ethyleneglycol with the addition of polyethyleneglycol (PEG) with molar mass of 4000, 8000 and 20000 g mol−1 are described, aimed at evaluating its effect on the size, morphology and stability of the nanoparticle. The syntheses were carried out by solubilizing the precursors at 85 and 140 °C, providing smaller nanoparticles as well as smaller crystallites at higher temperatures, while the effect of PEG was less evident. Measurements of nanoparticle surface areas synthesized with PEG 4000 and 20000 g mol−1 at 140 °C provided values of 76 and 14 m2 g−1, respectively, indicating that PEG 4000 surrounds the crystallites, while PEG 20000 preferably surrounds the whole MNP. As a consequence, MNP with very dissimilar porosities were obtained. Electron energy loss spectroscopy (EELS) indicated that MNP synthesized with PEG 20000 possesses higher electronic density than those obtained with PEG 4000, in agreement with the surface area results. Infrared spectroscopy and thermogravimetric analysis demonstrated the presence of PEG in the particles, whose amount increased as the particle size decreased. Dynamic Light Scattering (DLS) measurements showed that MNP hydrodynamic radius increases with the PEG size and stability in solution increases from pH 5.0 to 9.0 for smaller NP, while polymer presents slight effect on stability for the larger particles. The results obtained in this work show that properties of MNP can be tuned by the dissolution temperature of the chemical precursors and the PEG molar mass, changing their porosity and stability in solution, that are important variables in processes of adsorption, drug delivery and sensor developing.
- 1 June 2021
- Published by IOP Publishing in Nano Express
- Vol. 2 (2) , 020022
Open AccessPEG size effect and its interaction with Fe3O4 nanoparticles synthesized by solvothermal method: morphology and effect of pH on the stability
The synthesis and characterization of Fe3O4 magnetic nanoparticles (MNPs) obtained by the solvothermal method in ethyleneglycol with the addition of polyethyleneglycol (PEG) with molar mass of 4000, 8000 and 20000 g mol−1 are described, aimed at evaluating its effect on the size, morphology and stability of the nanoparticle. The syntheses were carried out by solubilizing the precursors at 85 and 140 °C, providing smaller nanoparticles as well as smaller crystallites at higher temperatures, while the effect of PEG was less evident. Measurements of nanoparticle surface areas synthesized with PEG 4000 and 20000 g mol−1 at 140 °C provided values of 76 and 14 m2 g−1, respectively, indicating that PEG 4000 surrounds the crystallites, while PEG 20000 preferably surrounds the whole MNP. As a consequence, MNP with very dissimilar porosities were obtained. Electron energy loss spectroscopy (EELS) indicated that MNP synthesized with PEG 20000 possesses higher electronic density than those obtained with PEG 4000, in agreement with the surface area results. Infrared spectroscopy and thermogravimetric analysis demonstrated the presence of PEG in the particles, whose amount increased as the particle size decreased. Dynamic Light Scattering (DLS) measurements showed that MNP hydrodynamic radius increases with the PEG size and stability in solution increases from pH 5.0 to 9.0 for smaller NP, while polymer presents slight effect on stability for the larger particles. The results obtained in this work show that properties of MNP can be tuned by the dissolution temperature of the chemical precursors and the PEG molar mass, changing their porosity and stability in solution, that are important variables in processes of adsorption, drug delivery and sensor developing.