Yabin Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yabin Liu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Lei Tan
State Key Laboratory of Hydroscience and Engineering, Department of Energy and Power Engineering, Tsinghua University, Beijing, China
6 shared publications - Yue Hao
State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China
3 shared publications - Yun Xu
State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China
3 shared publications - Baoshan Zhu
Tsinghua University
1 shared publication - Jinsong Zhang
State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China
1 shared publication - Ming Liu
State Key Laboratory of Hydroscience and Engineering, Department of Energy and Power Engineering, Tsinghua University, Beijing 100084, China
1 shared publication
Latest Publications
- 1 April 2020
- Published by Elsevier in Renewable Energy
- Vol. 149, 42-54
Method of T shape tip on energy improvement of a hydrofoil with tip clearance in tidal energy
- 1 April 2020
- Published by Elsevier in Renewable Energy
- Vol. 149, 42-54
Method of T shape tip on energy improvement of a hydrofoil with tip clearance in tidal energy
- 1 April 2020
- Published by Elsevier in Renewable Energy
- Vol. 148, 907-922
Influence of C groove on suppressing vortex and cavitation for a NACA0009 hydrofoil with tip clearance in tidal energy
- 1 April 2020
- Published by Elsevier in Renewable Energy
- Vol. 148, 907-922
Influence of C groove on suppressing vortex and cavitation for a NACA0009 hydrofoil with tip clearance in tidal energy
- Open Access
Influence of Prewhirl Angle and Axial Distance on Energy Performance and Pressure Fluctuation for a Centrifugal Pump with Inlet Guide Vanes
The energy performance and pressure fluctuations in a centrifugal pump with inlet guide vanes (IGVs) are investigated experimentally and numerically in a prewhirl angle range of −24° to 24° and in an axial distance range of 280 mm, 380 mm, and 460 mm. The reliability and accuracy of the numerical method are validated by the satisfactory agreement between the experimental data and numerical results. Prewhirl regulation with IGVs can significantly increase the energy performance and broaden the efficient operation range for the centrifugal pump due to the improvement of flow pattern at the impeller inlet. The prewhirl angle has an obvious impact on pump energy performance, and the maximum amplitudes of pressure fluctuations on the blade leading edge of the pressure and suction sides decrease by 69% and 89%, respectively. The axial distance has a slight impact on pump energy performance, but the maximum amplitudes of pressure fluctuations drop by 35.4% on the blade leading edge of pressure side when the axial distance extends from 280 mm to 460 mm.
Open AccessInfluence of Prewhirl Angle and Axial Distance on Energy Performance and Pressure Fluctuation for a Centrifugal Pump with Inlet Guide Vanes
The energy performance and pressure fluctuations in a centrifugal pump with inlet guide vanes (IGVs) are investigated experimentally and numerically in a prewhirl angle range of −24° to 24° and in an axial distance range of 280 mm, 380 mm, and 460 mm. The reliability and accuracy of the numerical method are validated by the satisfactory agreement between the experimental data and numerical results. Prewhirl regulation with IGVs can significantly increase the energy performance and broaden the efficient operation range for the centrifugal pump due to the improvement of flow pattern at the impeller inlet. The prewhirl angle has an obvious impact on pump energy performance, and the maximum amplitudes of pressure fluctuations on the blade leading edge of the pressure and suction sides decrease by 69% and 89%, respectively. The axial distance has a slight impact on pump energy performance, but the maximum amplitudes of pressure fluctuations drop by 35.4% on the blade leading edge of pressure side when the axial distance extends from 280 mm to 460 mm.
- Open Access
Energy Performance and Flow Patterns of a Mixed-Flow Pump with Different Tip Clearance Sizes
Tip clearance between blade end and shroud is inevitable in pump operation and of great importance on pump energy performance and pressure fluctuation. As the tip clearance size increases, the head and efficiency of the mixed flow pump drop accordingly. The simulation results show that the development of a leakage vortex is observed as the tip clearance increases, and the trajectory of this leakage vortex remains in the same direction along the blade suction side for different tip clearances. With the increase in tip clearance size, the intensity of the leakage vortex is enhanced, and the separation between the main leakage vortex and the secondary leakage vortex is also strengthened. The leakage separation angle near the blade tip remains at the same value of 10° for different tip clearance sizes. As for the spectrum analysis, the maximum amplitudes of pressure fluctuations dramatically increase in the impeller when the tip clearance increases from 0.0 mm to 1.0 mm, and the dominant frequencies go from 145 Hz to 184 Hz due to the considerable leakage flow.
Open AccessEnergy Performance and Flow Patterns of a Mixed-Flow Pump with Different Tip Clearance Sizes
Tip clearance between blade end and shroud is inevitable in pump operation and of great importance on pump energy performance and pressure fluctuation. As the tip clearance size increases, the head and efficiency of the mixed flow pump drop accordingly. The simulation results show that the development of a leakage vortex is observed as the tip clearance increases, and the trajectory of this leakage vortex remains in the same direction along the blade suction side for different tip clearances. With the increase in tip clearance size, the intensity of the leakage vortex is enhanced, and the separation between the main leakage vortex and the secondary leakage vortex is also strengthened. The leakage separation angle near the blade tip remains at the same value of 10° for different tip clearance sizes. As for the spectrum analysis, the maximum amplitudes of pressure fluctuations dramatically increase in the impeller when the tip clearance increases from 0.0 mm to 1.0 mm, and the dominant frequencies go from 145 Hz to 184 Hz due to the considerable leakage flow.
- Open Access
Energy Performance and Radial Force of a Mixed-Flow Pump with Symmetrical and Unsymmetrical Tip Clearances
The energy performance and radial force of a mixed flow pump with symmetrical and unsymmetrical tip clearance are investigated in this paper. As the tip clearance increases, the pump head and efficiency both decrease. The center of the radial force on the principal axis is located at the coordinate origin when the tip clearance is symmetrical, and moves to the third quadrant when the tip clearance is unsymmetrical. Analysis results show that the total radial force on the principal axis is closely related to the fluctuation of mass flow rate in each single flow channel. Unsteady simulations show that the dominant frequencies of radial force on the hub and blade correspond to the blade number, vane number, or double blade number because of the rotor stator interaction. The radial force on the blade pressure side decreases with the tip clearance increase because of leakage flow. The unsymmetrical tip clearances in an impeller induce uneven leakage flow rate and then result in unsymmetrical work ability of each blade and flow pattern in each channel. Thus, the energy performance decreases and the total radial force increases for a mixed flow pump with unsymmetrical tip clearance.
Open AccessEnergy Performance and Radial Force of a Mixed-Flow Pump with Symmetrical and Unsymmetrical Tip Clearances
The energy performance and radial force of a mixed flow pump with symmetrical and unsymmetrical tip clearance are investigated in this paper. As the tip clearance increases, the pump head and efficiency both decrease. The center of the radial force on the principal axis is located at the coordinate origin when the tip clearance is symmetrical, and moves to the third quadrant when the tip clearance is unsymmetrical. Analysis results show that the total radial force on the principal axis is closely related to the fluctuation of mass flow rate in each single flow channel. Unsteady simulations show that the dominant frequencies of radial force on the hub and blade correspond to the blade number, vane number, or double blade number because of the rotor stator interaction. The radial force on the blade pressure side decreases with the tip clearance increase because of leakage flow. The unsymmetrical tip clearances in an impeller induce uneven leakage flow rate and then result in unsymmetrical work ability of each blade and flow pattern in each channel. Thus, the energy performance decreases and the total radial force increases for a mixed flow pump with unsymmetrical tip clearance.