Ulriika Mattinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ulriika Mattinen has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Johan Bobacka
Laboratory of Molecular Science and Engineering, Faculty of Science and Engineering, Åbo Akademi University, Henriksgatan 2, 20500 Åbo-Turku, Finland
9 shared publications - Andrzej Lewenstam
Faculty of Materials Science and Ceramics, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Krakow, Poland
5 shared publications - Dermot Diamond
Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, Dublin, Ireland
3 shared publications - Tingting Han
Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China
3 shared publications Aleksandar Radu
2 shared publicationsGöran Lindbergh
2 shared publications
Latest Publications
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (59) , 2859
High-Throughput Screening of Molecules for Flow Batteries
Development of next generation stationary energy storage technologies is of crucial importance for increasing the share of the intermitted renewable electricity generation in the world. Traditional trial and error based approach for discovery of novel materials is very slow, so we have been thinking of how to accelerate the process. Some crucial parameters such as redox potentials can be readily evaluated with computational tools, such as those developed in our CompBat project [1], [2], but other parameters such as stability are more difficult to be evaluated. In this work we will demonstrate our web-based application for evaluating redox potentials of molecules from the SMILES structure, illustrating very impressive or problematic performance depending on the training data used for the model. For the question of stability, we believe that sufficient quantity of experimental data is required for training of specific machine learning models for stability prediction. For this purpose, we will illustrate our experimental approach for high-throughput electrochemistry, to evaluate the stability of molecules in the time-scale of voltammetry. Moreover, we will discuss the order of magnitude of the kinetics of the decomposition reactions that can be evaluated by voltammetry, and illustrate that voltammetry is a good tool for roughly separating more stable species from the less stable, but other techniques are required for evaluating stability in the time scale of battery operation. References https://compbat.eu/ A. Hamza, F.B. Németh, Á. Madarász, A. Nechaev, P. Pihko, P. Peljo, I. Pápai, N-alkylated pyridoxal derivatives as negative electrolyte materials for aqueous organic flow batteries: Computational screening, 10.26434/chemrxiv-2023-bzc6w
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (59) , 2859
High-Throughput Screening of Molecules for Flow Batteries
Development of next generation stationary energy storage technologies is of crucial importance for increasing the share of the intermitted renewable electricity generation in the world. Traditional trial and error based approach for discovery of novel materials is very slow, so we have been thinking of how to accelerate the process. Some crucial parameters such as redox potentials can be readily evaluated with computational tools, such as those developed in our CompBat project [1], [2], but other parameters such as stability are more difficult to be evaluated. In this work we will demonstrate our web-based application for evaluating redox potentials of molecules from the SMILES structure, illustrating very impressive or problematic performance depending on the training data used for the model. For the question of stability, we believe that sufficient quantity of experimental data is required for training of specific machine learning models for stability prediction. For this purpose, we will illustrate our experimental approach for high-throughput electrochemistry, to evaluate the stability of molecules in the time-scale of voltammetry. Moreover, we will discuss the order of magnitude of the kinetics of the decomposition reactions that can be evaluated by voltammetry, and illustrate that voltammetry is a good tool for roughly separating more stable species from the less stable, but other techniques are required for evaluating stability in the time scale of battery operation. References https://compbat.eu/ A. Hamza, F.B. Németh, Á. Madarász, A. Nechaev, P. Pihko, P. Peljo, I. Pápai, N-alkylated pyridoxal derivatives as negative electrolyte materials for aqueous organic flow batteries: Computational screening, 10.26434/chemrxiv-2023-bzc6w
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (65) , 3086
An Insight into the Lithium Plating – Operando Gas Evolution Study
Lithium-ion batteries (LiBs) play a major role in the electrification of transportation systems as a step forward in achieving a sustainable carbon neutral society [1]. Fast-charging is regarded as one of the most necessary features for lithium-ion batteries in order to speed the widespread adoption of electric vehicles [2]. However, we have previously shown that charging LiBs at high C-rate cause the evolution of high amount of ethylene gas along with capacity fade [3]. It is well known that fast charging is also may result in lithium plating and allied parasitic reactions [4]. Since many of the side reactions in LiBs are associated with evolution of products in gaseous phase, operando mass spectrometric techniques can be used to better understand these unwanted reactions. We have developed an Online Electrochemical Mass Spectrometry (OEMS) set-up to study the gases formed on a Li-plated electrode, to provide the fundamental understanding of the reaction mechanism at the electrode/electrolyte interface. References [1]. Bibra, E. M. et al. Global EV Outlook 2021: Accelerating Ambitions Despite the Pandemic. (2021). [2]. Huang, W., Ye, Y., Chen, H. et al. Onboard early detection and mitigation of lithium plating in fast-charging batteries. Nat Commun 13, 7091 (2022). [3]. Mattinen, Ulriika, et al. "Gas evolution in commercial Li-ion battery cells measured by on-line mass spectrometry–Effects of C-rate and cell voltage." Journal of Power Sources 477 (2020): 228968. [4]. Mussa, Abdilbari Shifa, et al. "Fast-charging to a partial state of charge in lithium-ion batteries: A comparative ageing study." Journal of Energy Storage 13 (2017): 325-333.
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (65) , 3086
An Insight into the Lithium Plating – Operando Gas Evolution Study
Lithium-ion batteries (LiBs) play a major role in the electrification of transportation systems as a step forward in achieving a sustainable carbon neutral society [1]. Fast-charging is regarded as one of the most necessary features for lithium-ion batteries in order to speed the widespread adoption of electric vehicles [2]. However, we have previously shown that charging LiBs at high C-rate cause the evolution of high amount of ethylene gas along with capacity fade [3]. It is well known that fast charging is also may result in lithium plating and allied parasitic reactions [4]. Since many of the side reactions in LiBs are associated with evolution of products in gaseous phase, operando mass spectrometric techniques can be used to better understand these unwanted reactions. We have developed an Online Electrochemical Mass Spectrometry (OEMS) set-up to study the gases formed on a Li-plated electrode, to provide the fundamental understanding of the reaction mechanism at the electrode/electrolyte interface. References [1]. Bibra, E. M. et al. Global EV Outlook 2021: Accelerating Ambitions Despite the Pandemic. (2021). [2]. Huang, W., Ye, Y., Chen, H. et al. Onboard early detection and mitigation of lithium plating in fast-charging batteries. Nat Commun 13, 7091 (2022). [3]. Mattinen, Ulriika, et al. "Gas evolution in commercial Li-ion battery cells measured by on-line mass spectrometry–Effects of C-rate and cell voltage." Journal of Power Sources 477 (2020): 228968. [4]. Mussa, Abdilbari Shifa, et al. "Fast-charging to a partial state of charge in lithium-ion batteries: A comparative ageing study." Journal of Energy Storage 13 (2017): 325-333.
- Open Access
- 1 January 2021
- Published by Elsevier in Electrochimica Acta
- Vol. 367
Coulometric response of solid-contact anion-sensitive electrodes
- 1 January 2021
- Published by Elsevier in Electrochimica Acta
- Vol. 367
Open AccessCoulometric response of solid-contact anion-sensitive electrodes
- 1 November 2020
- Published by Elsevier in Journal of Power Sources
- Vol. 477
Gas evolution in commercial Li-ion battery cells measured by on-line mass spectrometry – Effects of C-rate and cell voltage
- 1 November 2020
- Published by Elsevier in Journal of Power Sources
- Vol. 477
Gas evolution in commercial Li-ion battery cells measured by on-line mass spectrometry – Effects of C-rate and cell voltage
- Open Access
- 15 June 2020
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 24 (11-12) , 2975-2983
Coulometric response characteristics of solid contact ion-selective electrodes for divalent cations
The chronoamperometric and coulometric response of solid contact ion-selective electrodes (SCISEs) for the detection of divalent cations was investigated in order to provide a more complete description of the mechanism of the recently introduced coulometric transduction method for SCISEs. The coulometric transduction method has earlier been employed only for SCISEs that were selective to monovalent ions. The SCISEs utilized poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(styrene sulfonate) (PSS−) as the solid contact (ion-to-electron transducer). PEDOT(PSS) was electrodeposited on glassy carbon and covered with plasticized PVC-based ion-selective membranes (ISMs) that were selective towards divalent cations (Ca2+, Pb2+). In contrast to earlier studies, the results obtained in this work show that the coulometric response for the Pb2+-SCISE was limited mainly by ion transport in the PEDOT(PSS) layer, which was not the case for the Ca2+-SCISE, nor was it observed earlier for the monovalent ions. The exceptional behavior of the Pb2+-SCISE was explored further by electrochemical impedance spectroscopy, and it was shown that the effective redox capacitance of PEDOT(PSS) was significantly higher for the Pb2+-SCISE than for the Ca2+-SCISE although the polymerization charge of PEDOT(PSS) was the same. The slow transport of Pb2+ in PEDOT(PSS) was tentatively related to complexation between Pb2+ and PEDOT(PSS).
- 15 June 2020
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 24 (11-12) , 2975-2983
Open AccessCoulometric response characteristics of solid contact ion-selective electrodes for divalent cations
The chronoamperometric and coulometric response of solid contact ion-selective electrodes (SCISEs) for the detection of divalent cations was investigated in order to provide a more complete description of the mechanism of the recently introduced coulometric transduction method for SCISEs. The coulometric transduction method has earlier been employed only for SCISEs that were selective to monovalent ions. The SCISEs utilized poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(styrene sulfonate) (PSS−) as the solid contact (ion-to-electron transducer). PEDOT(PSS) was electrodeposited on glassy carbon and covered with plasticized PVC-based ion-selective membranes (ISMs) that were selective towards divalent cations (Ca2+, Pb2+). In contrast to earlier studies, the results obtained in this work show that the coulometric response for the Pb2+-SCISE was limited mainly by ion transport in the PEDOT(PSS) layer, which was not the case for the Ca2+-SCISE, nor was it observed earlier for the monovalent ions. The exceptional behavior of the Pb2+-SCISE was explored further by electrochemical impedance spectroscopy, and it was shown that the effective redox capacitance of PEDOT(PSS) was significantly higher for the Pb2+-SCISE than for the Ca2+-SCISE although the polymerization charge of PEDOT(PSS) was the same. The slow transport of Pb2+ in PEDOT(PSS) was tentatively related to complexation between Pb2+ and PEDOT(PSS).
- 30 June 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-04 (2) , 102
Studying Aging of Lithium Ion Batteries – Observing Gas Evolution with in-Operando Mass Spectrometry
Increasing our understanding on different aging processes and mechanisms linked to the lifetime and safety of lithium ion batteries is crucial for extending their usability in e.g. hybrid and electric vehicles followed by potential 2nd life applications. Coupling a mass spectrometer (MS) to a special on-line electrochemical cell hosting battery components enables time resolved detection of gases that are evolving during cycling and other aging. Gas evolving processes are for example decomposition of the electrolyte, formation of the SEI (solid electrolyte interphase) and other side reactions [1-3]. In this work, an in-house made adjustable electrochemical in-operando cell with a connection to the MS is used to study aging-related gas evolution at two types of cells: laboratory-scale lithium ion batteries and larger commercial cylindrical batteries. The design of the in-operando cell is flexible for different battery chemistries and to some extent different sizes. The commercial cylindrical cells used in this study are NMC-based Li-ion batteries. The battery can is pierced to allow gas diffusion inside the leak-tight housing connected to the MS. Aging of the large batteries can be inhomogeneous [4] and therefore it is highly interesting to measure the gas evaluation also from large cells and compare these to small laboratory-scale cells aged at more defined conditions. For the commercial batteries, the possibility to perform long term aging experiments is desirable. The cell construction used in this work allows replacing the gas sampled from the cell head-space, ensuring constant pressure in the measurement chamber and enabling prolonged measurements. A safety valve is installed to release overpressure in case of an extensive gas evolution. The goal of the presented work is to quantify gaseous products evolving upon battery aging with different operating parameters such as rate of charging [5], temperature, state of charge and voltage window to gain more insight to the aging phenomena. [1] S. Meini, M. Piana, N. Tsiouvaras, A. Garsuch, H.A. Gasteiger, Electrochemical and Solid-State Letters 15(4) (2012) A45-A48. [2] B.B. Berkes, A. Jozwiuk, M. Vracar, H. Sommer, T. Brezesinski, J. Janek, Analytical Chemistry 87(12) (2015) 5878-5883. [3] D. Streich, A. Gueguen, M. Mendez, F. Chesneau, P. Novak, E.J. Berg, Journal of the Electrochemical Society 163(6) (2016) A964-A970. [4] M. Klett, P. Svens, C. Tengstedt, A. Seyeux, J. Swiatowska, G. Lindbergh, R. Wreland Lindstroem, J. Phys. Chem. C 119(1) (2015) 90-100. [5] A.S. Mussa, M. Klett, M. Behm, G. Lindbergh, R.W. Lindström, Journal of Energy Storage 13 (2017) 325-333.
- 30 June 2019
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2019-04 (2) , 102
Studying Aging of Lithium Ion Batteries – Observing Gas Evolution with in-Operando Mass Spectrometry
Increasing our understanding on different aging processes and mechanisms linked to the lifetime and safety of lithium ion batteries is crucial for extending their usability in e.g. hybrid and electric vehicles followed by potential 2nd life applications. Coupling a mass spectrometer (MS) to a special on-line electrochemical cell hosting battery components enables time resolved detection of gases that are evolving during cycling and other aging. Gas evolving processes are for example decomposition of the electrolyte, formation of the SEI (solid electrolyte interphase) and other side reactions [1-3]. In this work, an in-house made adjustable electrochemical in-operando cell with a connection to the MS is used to study aging-related gas evolution at two types of cells: laboratory-scale lithium ion batteries and larger commercial cylindrical batteries. The design of the in-operando cell is flexible for different battery chemistries and to some extent different sizes. The commercial cylindrical cells used in this study are NMC-based Li-ion batteries. The battery can is pierced to allow gas diffusion inside the leak-tight housing connected to the MS. Aging of the large batteries can be inhomogeneous [4] and therefore it is highly interesting to measure the gas evaluation also from large cells and compare these to small laboratory-scale cells aged at more defined conditions. For the commercial batteries, the possibility to perform long term aging experiments is desirable. The cell construction used in this work allows replacing the gas sampled from the cell head-space, ensuring constant pressure in the measurement chamber and enabling prolonged measurements. A safety valve is installed to release overpressure in case of an extensive gas evolution. The goal of the presented work is to quantify gaseous products evolving upon battery aging with different operating parameters such as rate of charging [5], temperature, state of charge and voltage window to gain more insight to the aging phenomena. [1] S. Meini, M. Piana, N. Tsiouvaras, A. Garsuch, H.A. Gasteiger, Electrochemical and Solid-State Letters 15(4) (2012) A45-A48. [2] B.B. Berkes, A. Jozwiuk, M. Vracar, H. Sommer, T. Brezesinski, J. Janek, Analytical Chemistry 87(12) (2015) 5878-5883. [3] D. Streich, A. Gueguen, M. Mendez, F. Chesneau, P. Novak, E.J. Berg, Journal of the Electrochemical Society 163(6) (2016) A964-A970. [4] M. Klett, P. Svens, C. Tengstedt, A. Seyeux, J. Swiatowska, G. Lindbergh, R. Wreland Lindstroem, J. Phys. Chem. C 119(1) (2015) 90-100. [5] A.S. Mussa, M. Klett, M. Behm, G. Lindbergh, R.W. Lindström, Journal of Energy Storage 13 (2017) 325-333.
- Open Access
- 15 June 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (14) , 8700-8707
Capacitive Model for Coulometric Readout of Ion-Selective Electrodes
We present here a capacitive model for the coulometric signal transduction readout of solid-contact ion-selective membrane electrodes (SC-ISE) with a conducting polymer (CP) as an intermediate layer for the detection of anions. The capacitive model correlates well with experimental data obtained for chloride-selective SC-ISE utilizing poly(3,4-ethylenedioxythiophene) (PEDOT) doped with chloride as the ion-to-electron transducer. Additionally, Prussian blue is used as a simple sodium capacitor to further demonstrate the role of the transduction layer. The influence of different thicknesses of PEDOT as a conducting polymer transducer, different thicknesses of the overlaying ion-selective membranes deposited by drop casting and spin coating, and differ-ent compositions of the chloride-selective membrane are explored. The responses are evaluated in terms of current–time, charge–time and charge–chloride activity relationships. The utility of the sensor with coulometric readout is illustrated by the monitoring of very small concentration changes in solution.
- 15 June 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (14) , 8700-8707
Open AccessCapacitive Model for Coulometric Readout of Ion-Selective Electrodes
We present here a capacitive model for the coulometric signal transduction readout of solid-contact ion-selective membrane electrodes (SC-ISE) with a conducting polymer (CP) as an intermediate layer for the detection of anions. The capacitive model correlates well with experimental data obtained for chloride-selective SC-ISE utilizing poly(3,4-ethylenedioxythiophene) (PEDOT) doped with chloride as the ion-to-electron transducer. Additionally, Prussian blue is used as a simple sodium capacitor to further demonstrate the role of the transduction layer. The influence of different thicknesses of PEDOT as a conducting polymer transducer, different thicknesses of the overlaying ion-selective membranes deposited by drop casting and spin coating, and differ-ent compositions of the chloride-selective membrane are explored. The responses are evaluated in terms of current–time, charge–time and charge–chloride activity relationships. The utility of the sensor with coulometric readout is illustrated by the monitoring of very small concentration changes in solution.
- 1 August 2012
- Published by Elsevier in Electrochimica Acta
- Vol. 77, 23-28
Biomimetic membranes made of conducting polymers doped with adenosine diphosphate (ADP)
- 1 August 2012
- Published by Elsevier in Electrochimica Acta
- Vol. 77, 23-28
Biomimetic membranes made of conducting polymers doped with adenosine diphosphate (ADP)
- 1 July 2012
- Published by Elsevier in Electrochimica Acta
- Vol. 73, 93-97
Disposable solid-contact ion-selective electrodes for environmental monitoring of lead with ppb limit-of-detection
- 1 July 2012
- Published by Elsevier in Electrochimica Acta
- Vol. 73, 93-97
Disposable solid-contact ion-selective electrodes for environmental monitoring of lead with ppb limit-of-detection
- 1 December 2011
- Published by Elsevier in Electrochimica Acta
- Vol. 56 (28) , 10683-10687
Impedance study of the ion-to-electron transduction process for carbon cloth as solid-contact material in potentiometric ion sensors
- 1 December 2011
- Published by Elsevier in Electrochimica Acta
- Vol. 56 (28) , 10683-10687
Impedance study of the ion-to-electron transduction process for carbon cloth as solid-contact material in potentiometric ion sensors