Brian Kienitz
Brian Kienitz has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Bryan Pivovar
3 shared publications- Adam Zev Weber
Lawrence Berkeley National Laboratory
2 shared publications H. Baskaran
2 shared publications- Harihara Baskaran
Department of Chemical and Biomolecular Engineering, Center for Modular Manufacturing of Structural Tissues, Case Western Reserve University, 2102 Adelbert Road, 142 A.W. Smith Building, Cleveland, OH 44106, USA
2 shared publications - Ahmet Kusoglu
Lawrence Berkeley National Laboratory
1 shared publication Alastair MacDowell
Lawrence Berkeley National Laboratory
1 shared publication
Latest Publications
- 1 March 2021
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 46 (19) , 11176-11182
Optimizing polymer electrolyte membrane thickness to maximize fuel cell vehicle range
- 1 March 2021
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 46 (19) , 11176-11182
Optimizing polymer electrolyte membrane thickness to maximize fuel cell vehicle range
- 13 April 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-01 (2) , 223
Zinc/Iron Hybrid Flow Batteries for Grid Scale Energy Storage and Regulation
Megawatt scale energy storage that is reliable, safe, and cost effective is necessary for the integration of highly intermittent renewable energy sources and advanced grid technologies into our current electricity grid. These systems also need to show high round trip efficiency, high power, sufficient capacity, and versatile modes of operation to maximize their value. Zinc/iron (Zn/Fe) hybrid flow batteries have the promise to meet these demands due to their inexpensive, relatively safe, and abundant electrolyte chemistries. This presentation aims to discuss the merits and technical challenges of the Zn/Fe hybrid flow battery system with data from laboratory investigations, field installations, and economic analysis. Hybrid flow batteries are similar to traditional liquid/liquid flow batteries in that they store electrolytes separately from the power conversion cells. Unlike traditional flow batteries, hybrid flow batteries involve the deposition of a solid layer on at least one of the electrodes. The Zn/Fe hybrid flow battery negative electrolyte utilizes a complexed zinc anion. Zinc metal is deposited during charge and released back into solution on discharge. The positive electrolyte is comprised of an iron salt which changes oxidation states during charge and discharge. These electrolytes are composed of commercially available commodity chemicals that can be sourced for well under $100/kWh. A cation exchange membrane is used to separate the positive and negative electrolytes in the power conversion cell. Low molecular weight cations are shuttled back and forth across the membrane on charge and discharge to balance the reactions. Electrodes are made using non-precious metals and cell housings are composed of common injection moldable plastics. Most redox flow battery systems utilize acidic electrolytes. The ViZn Zn/Fe battery system utilizes basic electrolytes. Therefore, the redox species in the Zn/Fe system are anionic. Utilizing anionic redox species separated by a cationic exchange membrane significantly reduces susceptibility to cross over contamination. The relatively large anion species are unable to cross the membrane due to the principal of Gibbs-Donnan exclusion. This results in a battery system with high coulombic efficiency and the ability to use thin highly conductive cation exchange membranes. These membranes, when coupled with a precision engineered cell, create a hybrid flow battery system with high power and high energy efficiency. Inexpensive electrolytes coupled with high performance operation has allowed ViZn Energy Systems, Inc. to produce a robust four-hour battery system with a near term installed battery cost of under $350/kWh for use in the MW scale grid storage and regulation markets.
- 13 April 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-01 (2) , 223
Zinc/Iron Hybrid Flow Batteries for Grid Scale Energy Storage and Regulation
Megawatt scale energy storage that is reliable, safe, and cost effective is necessary for the integration of highly intermittent renewable energy sources and advanced grid technologies into our current electricity grid. These systems also need to show high round trip efficiency, high power, sufficient capacity, and versatile modes of operation to maximize their value. Zinc/iron (Zn/Fe) hybrid flow batteries have the promise to meet these demands due to their inexpensive, relatively safe, and abundant electrolyte chemistries. This presentation aims to discuss the merits and technical challenges of the Zn/Fe hybrid flow battery system with data from laboratory investigations, field installations, and economic analysis. Hybrid flow batteries are similar to traditional liquid/liquid flow batteries in that they store electrolytes separately from the power conversion cells. Unlike traditional flow batteries, hybrid flow batteries involve the deposition of a solid layer on at least one of the electrodes. The Zn/Fe hybrid flow battery negative electrolyte utilizes a complexed zinc anion. Zinc metal is deposited during charge and released back into solution on discharge. The positive electrolyte is comprised of an iron salt which changes oxidation states during charge and discharge. These electrolytes are composed of commercially available commodity chemicals that can be sourced for well under $100/kWh. A cation exchange membrane is used to separate the positive and negative electrolytes in the power conversion cell. Low molecular weight cations are shuttled back and forth across the membrane on charge and discharge to balance the reactions. Electrodes are made using non-precious metals and cell housings are composed of common injection moldable plastics. Most redox flow battery systems utilize acidic electrolytes. The ViZn Zn/Fe battery system utilizes basic electrolytes. Therefore, the redox species in the Zn/Fe system are anionic. Utilizing anionic redox species separated by a cationic exchange membrane significantly reduces susceptibility to cross over contamination. The relatively large anion species are unable to cross the membrane due to the principal of Gibbs-Donnan exclusion. This results in a battery system with high coulombic efficiency and the ability to use thin highly conductive cation exchange membranes. These membranes, when coupled with a precision engineered cell, create a hybrid flow battery system with high power and high energy efficiency. Inexpensive electrolytes coupled with high performance operation has allowed ViZn Energy Systems, Inc. to produce a robust four-hour battery system with a near term installed battery cost of under $350/kWh for use in the MW scale grid storage and regulation markets.
- 4 October 2011
- Published by The Electrochemical Society in ECS Transactions
- Vol. 41 (1) , 1521-1530
Ultra-Thin Reinforced Ionomer Membranes to Meet Next Generation Fuel Cell Targets
Over the last 20 years great progress has been made in increasing fuel cell performance and durability while reducing overall system cost, so much so that the commercialization of fuel cells for automotive and stationary applications is nearing economic feasibility. Still, further advances are needed before the potential of polymer electrolyte membrane fuel cells (PEMFC) can be realized. The incorporation of advanced thin reinforced ionomer membranes into the membrane electrode assembly (MEA) has been paramount to PEMFC progress1. Further reductions in membrane thickness are expected to increase fuel cell performance. In addition, thinner membranes reduce cost by reducing the amount of ionomer used in the MEA. Thin unreinforced membranes are likely to have reduced durability as compared to thicker unreinforced membranes2. Therefore new ionomers and reinforcement strategies are required to increase the durability of thin membranes and further enhance performance.
- 4 October 2011
- Published by The Electrochemical Society in ECS Transactions
- Vol. 41 (1) , 1521-1530
Ultra-Thin Reinforced Ionomer Membranes to Meet Next Generation Fuel Cell Targets
Over the last 20 years great progress has been made in increasing fuel cell performance and durability while reducing overall system cost, so much so that the commercialization of fuel cells for automotive and stationary applications is nearing economic feasibility. Still, further advances are needed before the potential of polymer electrolyte membrane fuel cells (PEMFC) can be realized. The incorporation of advanced thin reinforced ionomer membranes into the membrane electrode assembly (MEA) has been paramount to PEMFC progress1. Further reductions in membrane thickness are expected to increase fuel cell performance. In addition, thinner membranes reduce cost by reducing the amount of ionomer used in the MEA. Thin unreinforced membranes are likely to have reduced durability as compared to thicker unreinforced membranes2. Therefore new ionomers and reinforcement strategies are required to increase the durability of thin membranes and further enhance performance.
- Open Access
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (9) , B1175-H940
Cationic Contamination Effects on Polymer Electrolyte Membrane Fuel Cell Performance
An ultrafast atomic layer deposition technique is presented, based on the spatial separation of the half-reactions, by which alumina layers can be deposited with deposition rates of more than 1 nm/s. The deposition rate is limited by the water half-reaction, for which a kinetic model has been developed. The alumina layers showed excellent passivation of silicon wafers for solar cell applications. Based on this concept, a high-throughput ALD deposition tool is being developed targeting throughput numbers of up to 3000 wafers/h.
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (9) , B1175-H940
Open AccessCationic Contamination Effects on Polymer Electrolyte Membrane Fuel Cell Performance
An ultrafast atomic layer deposition technique is presented, based on the spatial separation of the half-reactions, by which alumina layers can be deposited with deposition rates of more than 1 nm/s. The deposition rate is limited by the water half-reaction, for which a kinetic model has been developed. The alumina layers showed excellent passivation of silicon wafers for solar cell applications. Based on this concept, a high-throughput ALD deposition tool is being developed targeting throughput numbers of up to 3000 wafers/h.
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (12) , B1504-B1514
Understanding the Effects of Compression and Constraints on Water Uptake of Fuel-Cell Membranes
Accurate characterization of polymer-electrolyte fuel cells (PEFCs) requires understanding the impact of mechanical and electrochemical loads on cell components. An essential aspect of this relationship is the effect of compression on the polymer membrane's water-uptake behavior and transport properties. However, there is limited information on the impact of physical constraints on membrane properties. In this paper, we investigate both theoretically and experimentally how the water uptake of Nafion membrane changes under external compression loads. The swelling of a compressed membrane is modeled by modifying the swelling pressure in the polymer backbone which relies on the changes in the microscopic volume of the polymer. The model successfully predicts the water content of the compressed membrane measured through in-situ swelling-compression tests and neutron imaging. The results show that external mechanical loads could reduce the water content and conductivity of the membrane, especially at lower temperatures, higher humidities, and in liquid water. The modeling framework and experimental data provide valuable insight for the swelling and conductivity of constrained and compressed membranes, which are of interest in electrochemical devices such as batteries and fuel cells.
- 1 January 2011
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 158 (12) , B1504-B1514
Understanding the Effects of Compression and Constraints on Water Uptake of Fuel-Cell Membranes
Accurate characterization of polymer-electrolyte fuel cells (PEFCs) requires understanding the impact of mechanical and electrochemical loads on cell components. An essential aspect of this relationship is the effect of compression on the polymer membrane's water-uptake behavior and transport properties. However, there is limited information on the impact of physical constraints on membrane properties. In this paper, we investigate both theoretically and experimentally how the water uptake of Nafion membrane changes under external compression loads. The swelling of a compressed membrane is modeled by modifying the swelling pressure in the polymer backbone which relies on the changes in the microscopic volume of the polymer. The model successfully predicts the water content of the compressed membrane measured through in-situ swelling-compression tests and neutron imaging. The results show that external mechanical loads could reduce the water content and conductivity of the membrane, especially at lower temperatures, higher humidities, and in liquid water. The modeling framework and experimental data provide valuable insight for the swelling and conductivity of constrained and compressed membranes, which are of interest in electrochemical devices such as batteries and fuel cells.
- 1 October 2010
- Published by The Electrochemical Society in ECS Transactions
- Vol. 33 (1) , 1407-1412
Tomographic Imaging of Water Injection and Withdrawal in PEMFC Gas Diffusion Layers
X-ray computed tomography was used to visualize the water configurations inside gas diffusion layers for various applied capillary pressures, corresponding to both water invasion and withdrawal. A specialized sample holder was developed to allow capillary pressure control on the small-scale samples required. Tests were performed on GDL specimens with and without hydrophobic treatments.
- 1 October 2010
- Published by The Electrochemical Society in ECS Transactions
- Vol. 33 (1) , 1407-1412
Tomographic Imaging of Water Injection and Withdrawal in PEMFC Gas Diffusion Layers
X-ray computed tomography was used to visualize the water configurations inside gas diffusion layers for various applied capillary pressures, corresponding to both water invasion and withdrawal. A specialized sample holder was developed to allow capillary pressure control on the small-scale samples required. Tests were performed on GDL specimens with and without hydrophobic treatments.
- 2 August 2010
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 94A (4) , 1050-1060
Concentrated collagen‐chondroitin sulfate scaffolds for tissue engineering applications
Collagen‐chondroitin sulfate biomaterial scaffolds have been used in a number of tissue‐engineered products under development or in the clinics. In this article, we describe a new approach based on centrifugation for obtaining highly concentrated yet porous collagen scaffolds. Water uptake, chondroitin sulfate retention, morphology, mechanical properties, and tissue‐engineering potential of the concentrated scaffolds were investigated. Our results show that the new approach can lead to scaffolds containing four times as much collagen as that in conventional unconcentrated scaffolds. Further, water uptake in the concentrated scaffolds was significantly greater while chondroitin sulfate retention in the concentrated scaffolds was unaffected. The value of mean pore diameter in the concentrated scaffolds was smaller than that in the unconcentrated scaffolds and the walls of the pores in the former comprised of a continuous sheet of collagen. The mechanical properties measured as moduli of elasticity in compression and tension were improved by as much as 30 times in the concentrated scaffolds. In addition, our tissue culture results with human mesenchymal stem cells and foreskin keratinocytes show that the new scaffolds can be used for cartilage and skin tissue–engineering applications. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.
- 2 August 2010
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 94A (4) , 1050-1060
Concentrated collagen‐chondroitin sulfate scaffolds for tissue engineering applications
Collagen‐chondroitin sulfate biomaterial scaffolds have been used in a number of tissue‐engineered products under development or in the clinics. In this article, we describe a new approach based on centrifugation for obtaining highly concentrated yet porous collagen scaffolds. Water uptake, chondroitin sulfate retention, morphology, mechanical properties, and tissue‐engineering potential of the concentrated scaffolds were investigated. Our results show that the new approach can lead to scaffolds containing four times as much collagen as that in conventional unconcentrated scaffolds. Further, water uptake in the concentrated scaffolds was significantly greater while chondroitin sulfate retention in the concentrated scaffolds was unaffected. The value of mean pore diameter in the concentrated scaffolds was smaller than that in the unconcentrated scaffolds and the walls of the pores in the former comprised of a continuous sheet of collagen. The mechanical properties measured as moduli of elasticity in compression and tension were improved by as much as 30 times in the concentrated scaffolds. In addition, our tissue culture results with human mesenchymal stem cells and foreskin keratinocytes show that the new scaffolds can be used for cartilage and skin tissue–engineering applications. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.
- 25 September 2009
- Published by The Electrochemical Society in ECS Transactions
- Vol. 25 (1) , 1575-1583
The Impact of Impurities on Long-Term PEMFC Performance
Electrochemical experimentation and modeling indicates that impurities degrade fuel cell performance by a variety of mechanisms. Electrokinetics may be inhibited by catalytic site poisoning from sulfur compounds and CO and by decreased local proton activity and mobility caused by the presence of foreign salt cations or ammonia. Cation impurity profiles vary with current density, valence and may change local conductivity and water concentrations in the ionomer. Nitrogen oxides and ammonia species may be electrochemically active under fuel cell operating conditions. The primary impurity removal mechanisms are electrooxidation and water fluxes through the fuel cell.
- 25 September 2009
- Published by The Electrochemical Society in ECS Transactions
- Vol. 25 (1) , 1575-1583
The Impact of Impurities on Long-Term PEMFC Performance
Electrochemical experimentation and modeling indicates that impurities degrade fuel cell performance by a variety of mechanisms. Electrokinetics may be inhibited by catalytic site poisoning from sulfur compounds and CO and by decreased local proton activity and mobility caused by the presence of foreign salt cations or ammonia. Cation impurity profiles vary with current density, valence and may change local conductivity and water concentrations in the ionomer. Nitrogen oxides and ammonia species may be electrochemically active under fuel cell operating conditions. The primary impurity removal mechanisms are electrooxidation and water fluxes through the fuel cell.
- 1 February 2009
- Published by Elsevier in Electrochimica Acta
- Vol. 54 (6) , 1671-1679
Modeling the steady-state effects of cationic contamination on polymer electrolyte membranes
- 1 February 2009
- Published by Elsevier in Electrochimica Acta
- Vol. 54 (6) , 1671-1679
Modeling the steady-state effects of cationic contamination on polymer electrolyte membranes
- 3 October 2008
- Published by The Electrochemical Society in ECS Transactions
- Vol. 16 (2) , 1069-1078
Determining the Mechanisms of Cationic Contamination on PEMFCs using a Strip Cell Configuration
Cationic contamination of polymer electrolyte fuel cells has been shown to cause serious performance degradation but the exact mechanisms of this degradation are not fully understood. A strip cell configuration was devised to study the mechanisms of performance degradation due to cationic contamination by changing the time and length scales of traditional fuel cells while providing a suitable reference electrode. This "strip cell" configuration utilizes traditional Nafion® membranes in an in-plane configuration with electrodes painted on each end. Using this cell it was determined that cationic contaminants collect near the cathode of the fuel cell under load and that this profile leads to increased losses primarily in the cathode region. These results can be directly related to performance losses in a typical PEMFC contaminated by foreign cations.
- 3 October 2008
- Published by The Electrochemical Society in ECS Transactions
- Vol. 16 (2) , 1069-1078
Determining the Mechanisms of Cationic Contamination on PEMFCs using a Strip Cell Configuration
Cationic contamination of polymer electrolyte fuel cells has been shown to cause serious performance degradation but the exact mechanisms of this degradation are not fully understood. A strip cell configuration was devised to study the mechanisms of performance degradation due to cationic contamination by changing the time and length scales of traditional fuel cells while providing a suitable reference electrode. This "strip cell" configuration utilizes traditional Nafion® membranes in an in-plane configuration with electrodes painted on each end. Using this cell it was determined that cationic contaminants collect near the cathode of the fuel cell under load and that this profile leads to increased losses primarily in the cathode region. These results can be directly related to performance losses in a typical PEMFC contaminated by foreign cations.