Stephan Bauer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stephan Bauer has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Luis Palafox
Physikalisch-Technische Bundesanstalt, Braunschweig, Germany
7 shared publications - Oliver Kieler
Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany
7 shared publications - Ralf Behr
Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
7 shared publications - Marco Kraus
Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
5 shared publications - Mattias Kruskopf
Physikalisch-Technische Bundesanstalt (PTB)
5 shared publications - Yaowaret Pimsut
Elektrische Quantenmetrologie, Physikalisch - Technische Bundesanstalt, Braunschweig, GERMANY
5 shared publications
Latest Publications
- 25 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
Josephson Arbitrary Waveform Synthesizer for Flux-Ramp Modulation in Microwave SQUID Multiplexers
Microwave SQUID multiplexers (μMUX) have become a key technology for the readout of large arrays of low-temperature detectors, particularly in cosmic microwave background experiments. A critical element of this technique is the flux-ramp modulation signal, whose noise, especially at low frequencies, directly limits the readout performance. This work proposes and experimentally demonstrates the use of a Josephson Arbitrary Waveform Synthesizer (JAWS) as a low-noise, high precision source for generating the sawtooth-shaped flux-ramp signal required in μMUX readout systems. The JAWS, based on the AC Josephson effect, provides intrinsically quantized and spectrally pure waveforms with excellent signal-to-noise ratio. The operation of a 9000-junction JAWS array is characterized and integrated with a cryogenic μMUX device and a custom SDR-based readout system. With this setup, the noise floor level around the harmonic typically used for phase demodulation of the SQUID signal to recover the detector signal was −104dBc/Hz, and the signal-to-noise ratio of this harmonic was 73dB. These results demonstrate the feasibility of using JAWS-based waveform synthesis for μMUX flux-ramp generation.
- 25 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
Josephson Arbitrary Waveform Synthesizer for Flux-Ramp Modulation in Microwave SQUID Multiplexers
Microwave SQUID multiplexers (μMUX) have become a key technology for the readout of large arrays of low-temperature detectors, particularly in cosmic microwave background experiments. A critical element of this technique is the flux-ramp modulation signal, whose noise, especially at low frequencies, directly limits the readout performance. This work proposes and experimentally demonstrates the use of a Josephson Arbitrary Waveform Synthesizer (JAWS) as a low-noise, high precision source for generating the sawtooth-shaped flux-ramp signal required in μMUX readout systems. The JAWS, based on the AC Josephson effect, provides intrinsically quantized and spectrally pure waveforms with excellent signal-to-noise ratio. The operation of a 9000-junction JAWS array is characterized and integrated with a cryogenic μMUX device and a custom SDR-based readout system. With this setup, the noise floor level around the harmonic typically used for phase demodulation of the SQUID signal to recover the detector signal was −104dBc/Hz, and the signal-to-noise ratio of this harmonic was 73dB. These results demonstrate the feasibility of using JAWS-based waveform synthesis for μMUX flux-ramp generation.
- Open Access
- 19 February 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (2) , 025007
Development and implementation of an automated four-terminal-pair Josephson impedance bridge
The four-terminal-pair impedance bridge using pulse-driven Josephson voltage standards at PTB has been fully automated. The same bridge configuration was employed to determine R:R and C:C ratios over the frequency range between 53 Hz to 50 kHz. Only minor changes are needed to cover this large frequency range: amplifiers to increase the sensitivity of the current detections for low frequencies and signal generators with higher resolution at high frequencies to reach 50 kHz. Furthermore, the bridge can be operated for quadrature R:(1/ωC) measurements. The combined standard uncertainties (k = 1) for the new bridge were evaluated for all operating frequencies. They reach 2 nF F−1 and 4 nΩ Ω−1 at 1233.15 Hz. At this frequency, the 10 nF:10 nF ratio matched the ratio of PTB’s bridge employing inductive voltage dividers within 1 nF F−1 ± 3 nF F−1 (k = 1). Over 45 days, the 10 nF:10 nF ratio deviated less than −2 nF F−1 ± 3 nF F−1 (k = 1). The 12.9 kΩ:10 kΩ ratio at 53 Hz differed −2 nΩ Ω−1 ± 5 nΩ Ω−1 (k = 1) from the DC ratio measured by the PTB’s cryogenic current comparator bridge. Using a 12.9 kΩ resistance standard and a graphene AC quantum Hall resistance, the 10 nF:10 nF ratios derived from quadrature measurements agreed with the PTB’s inductive voltage divider bridge better than 9 nF F−1 ± 13 nF F−1 (k = 1).
- 19 February 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (2) , 025007
Open AccessDevelopment and implementation of an automated four-terminal-pair Josephson impedance bridge
The four-terminal-pair impedance bridge using pulse-driven Josephson voltage standards at PTB has been fully automated. The same bridge configuration was employed to determine R:R and C:C ratios over the frequency range between 53 Hz to 50 kHz. Only minor changes are needed to cover this large frequency range: amplifiers to increase the sensitivity of the current detections for low frequencies and signal generators with higher resolution at high frequencies to reach 50 kHz. Furthermore, the bridge can be operated for quadrature R:(1/ωC) measurements. The combined standard uncertainties (k = 1) for the new bridge were evaluated for all operating frequencies. They reach 2 nF F−1 and 4 nΩ Ω−1 at 1233.15 Hz. At this frequency, the 10 nF:10 nF ratio matched the ratio of PTB’s bridge employing inductive voltage dividers within 1 nF F−1 ± 3 nF F−1 (k = 1). Over 45 days, the 10 nF:10 nF ratio deviated less than −2 nF F−1 ± 3 nF F−1 (k = 1). The 12.9 kΩ:10 kΩ ratio at 53 Hz differed −2 nΩ Ω−1 ± 5 nΩ Ω−1 (k = 1) from the DC ratio measured by the PTB’s cryogenic current comparator bridge. Using a 12.9 kΩ resistance standard and a graphene AC quantum Hall resistance, the 10 nF:10 nF ratios derived from quadrature measurements agreed with the PTB’s inductive voltage divider bridge better than 9 nF F−1 ± 13 nF F−1 (k = 1).
- 31 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-6
Performance and Stability Assessment of Graphene-Based Quantum Hall Devices for Resistance Metrology
For more than three decades, GaAs/AlGaAs quantum Hall (QH) devices are being used as standards for the realization of the dc resistance unit ohm. Recently, the outstanding performance of graphene-based quantum Hall resistance (QHR) devices signifies an immense potential for a transition from GaAs to graphene-based devices in the field of resistance and also impedance metrology, with equally good accuracy. The recent developments in epitaxial graphene (EG) quality and fabrication of EG-based doped QHR devices and their improved performance tested in several national metrology institutes (NMIs) all over the world have demonstrated a more user-friendly dissemination of the unit ohm since they can be operated at relatively low magnetic fields and higher temperatures in comparison to existing GaAs-based devices. In this work, we have extensively tested the temporal stability of the magneto-transport properties of our graphene QH devices fabricated in the PTB and the resistance quantization performance by means of repeated high-accuracy cryogenic current comparator (CCC) measurements with several devices. Together with interlaboratory comparisons between NMI’s, the performance and stability assessment demonstrate the readiness of the technology for calibration purposes in resistance metrology.
- 31 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-6
Performance and Stability Assessment of Graphene-Based Quantum Hall Devices for Resistance Metrology
For more than three decades, GaAs/AlGaAs quantum Hall (QH) devices are being used as standards for the realization of the dc resistance unit ohm. Recently, the outstanding performance of graphene-based quantum Hall resistance (QHR) devices signifies an immense potential for a transition from GaAs to graphene-based devices in the field of resistance and also impedance metrology, with equally good accuracy. The recent developments in epitaxial graphene (EG) quality and fabrication of EG-based doped QHR devices and their improved performance tested in several national metrology institutes (NMIs) all over the world have demonstrated a more user-friendly dissemination of the unit ohm since they can be operated at relatively low magnetic fields and higher temperatures in comparison to existing GaAs-based devices. In this work, we have extensively tested the temporal stability of the magneto-transport properties of our graphene QH devices fabricated in the PTB and the resistance quantization performance by means of repeated high-accuracy cryogenic current comparator (CCC) measurements with several devices. Together with interlaboratory comparisons between NMI’s, the performance and stability assessment demonstrate the readiness of the technology for calibration purposes in resistance metrology.
- Open Access
- 21 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 032001
Josephson voltage standards as toolkit for precision metrological applications at PTB
About 60 years after the discovery of the Josephson effect, electrical DC voltage calibrations are routinely performed worldwide—mostly using automated Josephson voltage standards (JVSs). Nevertheless, the field of electrical quantum voltage metrology is still propagating towards AC applications. In the past 10 years the fabrication of highly integrated arrays containing more than 50 000 or even 300 000 junctions has achieved a very robust level providing highly functional devices. Such reliable Josephson arrays are the basis for many novel applications mainly focussing on precision AC measurements for signal frequencies up to 500 kHz. Two versions of quantum AC standards are being employed. Programmable JVS, based on series arrays divided into subarrays, reach amplitudes up to 20 V and usually are used as quantum voltage reference in measurement systems. Pulse driven arrays reach amplitudes up to 1 V or even 4 V and are typically used as Josephson arbitrary waveform synthesizers. This paper summarizes the principal contributions from Physikalisch-Technische Bundesanstalt to the present state of JVS with particular focus on developments for precision metrological applications and our proof-of-concept demonstrations.
- 21 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 032001
Open AccessJosephson voltage standards as toolkit for precision metrological applications at PTB
About 60 years after the discovery of the Josephson effect, electrical DC voltage calibrations are routinely performed worldwide—mostly using automated Josephson voltage standards (JVSs). Nevertheless, the field of electrical quantum voltage metrology is still propagating towards AC applications. In the past 10 years the fabrication of highly integrated arrays containing more than 50 000 or even 300 000 junctions has achieved a very robust level providing highly functional devices. Such reliable Josephson arrays are the basis for many novel applications mainly focussing on precision AC measurements for signal frequencies up to 500 kHz. Two versions of quantum AC standards are being employed. Programmable JVS, based on series arrays divided into subarrays, reach amplitudes up to 20 V and usually are used as quantum voltage reference in measurement systems. Pulse driven arrays reach amplitudes up to 1 V or even 4 V and are typically used as Josephson arbitrary waveform synthesizers. This paper summarizes the principal contributions from Physikalisch-Technische Bundesanstalt to the present state of JVS with particular focus on developments for precision metrological applications and our proof-of-concept demonstrations.
- Open Access
- 13 September 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (6) , 065001
PTB–INRIM comparison of novel digital impedance bridges with graphene impedance quantum standards
This paper describes an onsite comparison of two different digital impedance bridges when performing measurements on a quantum Hall resistance standard with the purpose of realizing the SI unit of capacitance, the farad. In the EMPIR Joint Research Project 18SIB07 GIQS, graphene impedance quantum standards, the Physikalisch-Technische Bundesanstalt (PTB), Germany, developed a Josephson impedance bridge, and the Istituto Nazionale di Ricerca Metrologica (INRIM) and the Politecnico di Torino (POLITO), Italy, developed an electronic digital impedance bridge. The former is based on Josephson waveform generators and the latter on an electronic waveform synthesizer. The INRIM–POLITO impedance bridge was moved to PTB and the two bridges were compared by measuring both temperature-controlled standards and a graphene AC quantized Hall resistance (QHR) standard. The uncertainties for the calibration of 10 nF capacitance standards at 1233 Hz are within 1 × 10−8 for the PTB’s bridge and around 1 × 10−7 for the INRIM–POLITO’s bridge. The comparison mutually validates the two bridges within the combined uncertainty. The result confirms that digital impedance bridges allow the realization of the SI farad from the QHR with uncertainties comparable with the best calibration capabilities of the BIPM and the major National Metrology Institutes.
- 13 September 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (6) , 065001
Open AccessPTB–INRIM comparison of novel digital impedance bridges with graphene impedance quantum standards
This paper describes an onsite comparison of two different digital impedance bridges when performing measurements on a quantum Hall resistance standard with the purpose of realizing the SI unit of capacitance, the farad. In the EMPIR Joint Research Project 18SIB07 GIQS, graphene impedance quantum standards, the Physikalisch-Technische Bundesanstalt (PTB), Germany, developed a Josephson impedance bridge, and the Istituto Nazionale di Ricerca Metrologica (INRIM) and the Politecnico di Torino (POLITO), Italy, developed an electronic digital impedance bridge. The former is based on Josephson waveform generators and the latter on an electronic waveform synthesizer. The INRIM–POLITO impedance bridge was moved to PTB and the two bridges were compared by measuring both temperature-controlled standards and a graphene AC quantized Hall resistance (QHR) standard. The uncertainties for the calibration of 10 nF capacitance standards at 1233 Hz are within 1 × 10−8 for the PTB’s bridge and around 1 × 10−7 for the INRIM–POLITO’s bridge. The comparison mutually validates the two bridges within the combined uncertainty. The result confirms that digital impedance bridges allow the realization of the SI farad from the QHR with uncertainties comparable with the best calibration capabilities of the BIPM and the major National Metrology Institutes.
- Open Access
- 3 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 68 (7) , 3672-3677
Graphene Quantum Hall Effect Devices for AC and DC Electrical Metrology
A new type of graphene-based quantum Hall standards is tested for electrical quantum metrology applications at alternating current (ac) and direct current (dc). The devices are functionalized with Cr(CO) 3 to control the charge carrier density and have branched Hall contacts based on NbTiN superconducting material. The work is an in-depth study about the characteristic capacitances and related losses in the ac regime of the devices and about their performance during precision resistance measurements at dc and ac.
- 3 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 68 (7) , 3672-3677
Open AccessGraphene Quantum Hall Effect Devices for AC and DC Electrical Metrology
A new type of graphene-based quantum Hall standards is tested for electrical quantum metrology applications at alternating current (ac) and direct current (dc). The devices are functionalized with Cr(CO) 3 to control the charge carrier density and have branched Hall contacts based on NbTiN superconducting material. The work is an in-depth study about the characteristic capacitances and related losses in the ac regime of the devices and about their performance during precision resistance measurements at dc and ac.
- Open Access
- 31 March 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (6) , 065007
A four-terminal-pair Josephson impedance bridge combined with a graphene-quantized Hall resistance
This paper introduces a four-terminal-pair impedance bridge based on pulse-driven Josephson junctions arrays which is designed to link any kind of impedance to the quantized Hall resistance. The unique features of the quantized Hall resistance in a multiple series connection allows to dispense a combining network and leads to a compact and simple design of the whole setup. Moreover, the low noise of a quantized Hall resistance reduces the measurement time compared to resistance standards at room temperature which is essential for the characterization of quantum Hall devices in the AC regime. A first measurement campaign confirmed the expected low noise of 1.82 n V / H z for a link to a 10 nF capacitance standard. The repeatability of the bridge was found to be few parts in 108. Capacitance and resistance standards were measured at 1233.15 Hz against graphene based quantum Hall resistance devices.
- 31 March 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (6) , 065007
Open AccessA four-terminal-pair Josephson impedance bridge combined with a graphene-quantized Hall resistance
This paper introduces a four-terminal-pair impedance bridge based on pulse-driven Josephson junctions arrays which is designed to link any kind of impedance to the quantized Hall resistance. The unique features of the quantized Hall resistance in a multiple series connection allows to dispense a combining network and leads to a compact and simple design of the whole setup. Moreover, the low noise of a quantized Hall resistance reduces the measurement time compared to resistance standards at room temperature which is essential for the characterization of quantum Hall devices in the AC regime. A first measurement campaign confirmed the expected low noise of 1.82 n V / H z for a link to a 10 nF capacitance standard. The repeatability of the bridge was found to be few parts in 108. Capacitance and resistance standards were measured at 1233.15 Hz against graphene based quantum Hall resistance devices.
- 30 September 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (12) , 125003
Measurement and analysis of high-frequency voltage errors in the Josephson arbitrary waveform synthesizer
This paper reports on the comparison of two Josephson arbitrary waveform synthesizers for frequencies up to 500 kHz. Both independent pulse-driven Josephson arrays produce a 10 mV RMS sinusoidal voltage. They are alternately connected to an analog-to-digital converter which serves as a transfer standard. The setup is capable to of synthesizing quantum-based waveforms using two different pulse-bias techniques. We use the Zero-Compensation method and a two-pole high-pass filter structure in the pulse-bias configuration of one system (the reference) to minimize the amplitude error for signal frequencies up to 500 kHz. Consequently, we are able to directly detect the high-frequency voltage errors in the other system (the device under test). The setup is used to measure differences between both systems, and the influence of parameter variation on the results with Type A uncertainties of 0.4 µV/V ( k = 1) in measurement times of 60 s. We find that the dominant sources of deviations above 10 kHz can be traced to the influence of the output cabling and the pulse bias on the synthesized voltage signal. Our analysis explains the origin and the reduction of these high-frequency voltage errors.
- 30 September 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (12) , 125003
Measurement and analysis of high-frequency voltage errors in the Josephson arbitrary waveform synthesizer
This paper reports on the comparison of two Josephson arbitrary waveform synthesizers for frequencies up to 500 kHz. Both independent pulse-driven Josephson arrays produce a 10 mV RMS sinusoidal voltage. They are alternately connected to an analog-to-digital converter which serves as a transfer standard. The setup is capable to of synthesizing quantum-based waveforms using two different pulse-bias techniques. We use the Zero-Compensation method and a two-pole high-pass filter structure in the pulse-bias configuration of one system (the reference) to minimize the amplitude error for signal frequencies up to 500 kHz. Consequently, we are able to directly detect the high-frequency voltage errors in the other system (the device under test). The setup is used to measure differences between both systems, and the influence of parameter variation on the results with Type A uncertainties of 0.4 µV/V ( k = 1) in measurement times of 60 s. We find that the dominant sources of deviations above 10 kHz can be traced to the influence of the output cabling and the pulse bias on the synthesized voltage signal. Our analysis explains the origin and the reduction of these high-frequency voltage errors.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Applications of the Josephson based spectrum analyzer
The Josephson spectrum analyzer exploits the programmable frequency spectrum in a Josephson Arbitrary Waveform Generator (JAWS) to measure a signal. The waveform to be measured is copied by the JAWS system. A conventional spectrum analyzer is used as a multi frequency null detector when the waveform and its JAWS copy are cancelled. We report the comparison of the Josephson spectrum analyzer with the classical approach used to measure harmonics present in waveforms, using a state of the art notch filter and a low noise amplifier. We also report measurements of the theoretically predicted-quantization harmonics, at −129 dBc, in a JAWS sinewave when a first order delta sigma modulator is used.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Applications of the Josephson based spectrum analyzer
The Josephson spectrum analyzer exploits the programmable frequency spectrum in a Josephson Arbitrary Waveform Generator (JAWS) to measure a signal. The waveform to be measured is copied by the JAWS system. A conventional spectrum analyzer is used as a multi frequency null detector when the waveform and its JAWS copy are cancelled. We report the comparison of the Josephson spectrum analyzer with the classical approach used to measure harmonics present in waveforms, using a state of the art notch filter and a low noise amplifier. We also report measurements of the theoretically predicted-quantization harmonics, at −129 dBc, in a JAWS sinewave when a first order delta sigma modulator is used.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
AC Quantum Hall Resistance combined with a Four-Terminal Pair Pulse-Driven Josephson Impedance Bridge
A novel four-terminal pair impedance bridge combined with a quantum Hall resistor will be presented. The impedance bridge is based on pulse-driven Josephson arrays. A very simple setup is possible due to the triple-series connection of the quantum Hall resistor that renders combining networks superfluous. This combination of the two well-known macroscopic quantum effects presents a unique possibility for the realization of electrical units. Moreover, the Josephson bridge can be used to precisely investigate the plateau shape of quantum Hall devices in the AC regime.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
AC Quantum Hall Resistance combined with a Four-Terminal Pair Pulse-Driven Josephson Impedance Bridge
A novel four-terminal pair impedance bridge combined with a quantum Hall resistor will be presented. The impedance bridge is based on pulse-driven Josephson arrays. A very simple setup is possible due to the triple-series connection of the quantum Hall resistor that renders combining networks superfluous. This combination of the two well-known macroscopic quantum effects presents a unique possibility for the realization of electrical units. Moreover, the Josephson bridge can be used to precisely investigate the plateau shape of quantum Hall devices in the AC regime.