PJPaul Wayland Jones

Paul Wayland Jones

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paul Wayland Jones has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High Initial Heart Rate Score is an Independent Predictor of New Atrial High-Rate Episodes in Pacemaker Patients with Sinus Node Dysfunction

    by Katsuhide Hayashi, Haruhiko Abe, Brian Olshansky, Arjun D. Sharma, Paul Wayland Jones, Nicholas Wold, David Perschbacher, Ritsuko Kohno, Gregory Y. H. Lip, Bruce L. Wilkoff

    Background: Heart Rate Score (HRSc), the percent of atrial beats in the largest paced/sensed 10-bpm histogram bin recorded in cardiac devices, is a metric of chronotropic incompetence. It remains uncertain if HRSc independently predicts atrial high-rate episodes (AHREs) in patients with sinus node dysfunction (SND) undergoing pacemaker (PM) implantation. Objective: To determine the relationship between initial HRSc post-PM implant and new-onset AHREs in patients with SND. Methods: The cohort included patients with Boston Scientific PMs implanted for SND from 2012-2021 at Cleveland Clinic, University of Occupational and Environmental Health, Japan, Kyushu Rosai Hospital, and JCHO Kyushu Hospital. Patients were excluded if they had atrial fibrillation before PM implant or AHREs in the initial 3-months post-implant. Subsequent AHREs post-implant (>1% of atrial beats>170 bpm) were evaluated. Results: Over 48.9 (IQR 25.8-50.4) months, 136 consecutive PM patients (age 75±10 years, 42% male) were followed. The median initial HRSc was 73(55-86)%. AHREs developed in 28/136 (21%). Although %RA pacing and HRSc correlated, rate-responsive pacing was associated with a HRSc only in the patients with high %RA pacing. Patients with HRSc≥80% had higher occurrence of AHREs than those with HRSc<80% (p=0.01, log-rank test). After adjusting for age, race, comorbidities, left ventricular ejection fraction, left atrial diameter, %RA/RV pacing, and rate-response programming, HRSc (HR:2.84, 95% CI:1.17-6.92; P=0.02) and male sex (HR:2.55, 95% CI:1.15-6.19; P=0.04) were independent predictors of AHREs. Conclusion: HRSc≥80% independently predicted new-onset, device-determined AHREs for patients undergoing PM implant for SND. HRSc may have prognostic and therapeutic implications.

  • Open Access

    Initial heart rate score predicts new-onset atrial tachyarrhythmias in pacemaker patients

    by Katsuhide Hayashi, Haruhiko Abe, Brian Olshansky, Arjun D Sharma, Paul W Jones, Nicholas Wold, David Perschbacher, Ritsuko Kohno, Mark Richards, Bruce L Wilkoff

    Heart rate score (HRSc), the per cent of atrial paced and sensed event in the largest 10 b.p.m. rate histogram bin of a pacemaker, predicts survival in patients with cardiac devices. No correlation between HRSc and development of atrial fibrillation (AF) has been reported. In this study, we evaluated the relationship between pacemaker post-implantation HRSc and the incidence of newly developed atrial tachyarrhythmias (ATAs). Patients with dual-chamber pacemakers, implanted 2013–17, with the LATITUDE remote monitoring data with ≥600 000 beats of histogram data collected at baseline were included (N = 34 543). Heart rate score was determined from the initial 3-month post-implantation histogram data. Patients were excluded if they had ATAs, defined as atrial high-rate episodes >5 min or >1% of right atrial beats >170 b.p.m. during the initial 3 months post-implantation. New ATAs, after the baseline period, were defined by each of the following: >1, >10, or >25% of atrial beats >170 b.p.m. or atrial tachycardia response (ATR) events >24 h. Patients were followed a median of 2.8 (1.0–4.0) years. The incidence of ATAs increased in proportion to HRSc (log-rank P-value P < 0.0001) independently predicted ATAs after adjusting for age, gender, %RV pacing, and rate-response programming. The %RA pacing and initial HRSc were correlated. Heart rate score independently predicts any subsequent duration of ATAs in pacemaker patients.


  • Lower rate limit for pacing by cardiac resynchronization defibrillators: Should lower rate programming be reconsidered?

    by Arjun D. Sharma, Bruce L. Wilkoff, Mark Richards, Nicholas Wold, Paul Jones, David Perschbacher, Brian Olshansky


  • Open Access

    Heart rate score, a measure related to chronotropic incompetence in pacemaker patients

    by Arjun D. Sharma, Mark Richards, Brian Olshansky, Nicholas Wold, Paul Jones, David Perschbacher, Bruce L. Wilkoff


  • Open Access

    Prospective blinded evaluation of a novel sensing methodology designed to reduce inappropriate shocks by the subcutaneous implantable cardioverter-defibrillator

    by Dominic A.M.J. Theuns, Tom F. Brouwer, Paul W. Jones, Venugopal Allavatam, Steven Donnelley, Angelo Auricchio, Reinoud E. Knops, Martin C. Burke


  • Implantable Cardioverter Defibrillator Electrogram Adjudication for Device Registries: Methodology and Observations from ALTITUDE

    by Brian D. Powell, Yong‐Mei Cha, Samuel J. Asirvatham, David A. Cesario, Michael Cao, Paul W. Jones, Milan Seth, Leslie A. Saxon, F. Roosevelt Gilliam Iii

    The increasing use of remote monitoring with the associated large retrievable databases provides a unique opportunity to analyze observations on implantable cardioverter-defibrillator (ICD) therapies. Adjudication of a large number of stored ICD electrograms (EGMs) presents a unique challenge. The ALTITUDE study group was designed to use the LATITUDE remote monitoring system to evaluate ICD patient outcomes across the United States. Of 81,081 patients on remote monitoring, a random sample of 2,000 patients having 5,279 shock episodes was selected. The ALTITUDE EGM review committee was comprised of seven electrophysiologists from four institutions. An online EGM adjudication system was designed. Episodes were classified as appropriate (70% of shock episodes) or inappropriate ICD therapies (30%). Light's Kappa was used to assess agreement. Interobserver and intraobserver Kappa scores for dual-chamber ICDs were 0.84 (0.71-0.91) and 0.89 (0.82-0.95), consistent with substantial agreement. Interobserver and intraobserver Kappa scores for single-chamber ICDs were 0.61 (0.54-0.67) and 0.69 (0.59-0.79). The rhythm categories of "nonsustained arrhythmia" and "polymorphic and monomorphic ventricular tachycardia" resulted in the greatest degree of discordant adjudication between reviewers. This method of adjudication of a large volume of stored EGM data prior to device therapies will allow new observations in regards to device performance and has the potential to improve device programming and design. There was substantial interreviewer agreement for rhythm classification. Agreement was greater for dual-chamber compared to single-chamber devices, indicating the atrial lead adds diagnostic value in rhythm interpretation.