LKLaszlo Kiraly

Laszlo Kiraly

*This is an algorithmically generated author record based on publicly available information.

Laszlo Kiraly has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Solar Length as a Predictor of Trauma Volume: A 10-Year Study on Seasonality, Pandemic Effects, and Machine Learning Applications

    by Phillip Jenkins, Michael Kolesnikov, Steven Bedrick, Anais Kolesnikov, Laszlo Kiraly

    Introduction: Trauma is a leading cause of global mortality and has been influenced by the COVID-19 pandemic. The interaction between trauma seasonality and pandemic effects remains understudied. From an AI modeling perspective, understanding seasonal shifts over the last four years is critical to training reliable models. Methods: We performed a retrospective study of 33,945 trauma admissions from 2014–2024 at a single Level I trauma center. Demographics, injury characteristics, and transfusion data were analyzed alongside weather and environmental variables including temperature, humidity, precipitation, wind speed, dew point, visibility, barometric pressure, workday status, and solar length. Statistical analyses included Chi-square, Cragg-Uhler, McFadden, AIC, and BIC. Results: Solar length was the strongest predictor of admissions, with longer days associated with increased trauma volume. This effect intensified after 2020 and remained elevated post-pandemic. Ground-level falls and MVCs increased, while ISS decreased. XGBoost performed well on training data (R² = 0.66, MAE = 1.75). Discussion: Seasonality strengthened after 2020, and trauma admissions remain directly proportional to solar length. AI models using this metric accurately forecast admissions over 60-day intervals.

  • Open Access

    Comparison of two extended depth of focus intraocular lenses with a monofocal lens: a multi-centre randomised trial

    by Thomas Reinhard, Philip Maier, Daniel Böhringer, Eckart Bertelmann, Tobias Brockmann, Laszlo Kiraly, David Salom, Matteo Piovella, Stephane Colonval, Javier Mendicute

    Purpose: The AT LARA 829MP is a next-generation extended depth of focus (EDOF) intraocular lens (IOL) providing continuous vision over a range of distances. The aim of this prospective multi-centre randomised trial was to compare two EDOF IOLs and one monofocal IOL. Methods: Cataract patients between 50 and 80 years were randomised for bilateral implantation with either the AT LARA 829MP (EDOF), the TECNIS Symfony (EDOF) or the CT ASPHINA 409MP (monofocal). Follow-up was at 1 to 2 weeks, 1 month and 4 to 6 months. Results: A total of 211 patients were randomised and included in the final analysis. Monocular depth of focus was significantly better for AT LARA 829MP eyes compared with that for TECNIS Symfony at all thresholds (p = 0.024, 0.001 and 0.006, for 0.1, 0.2 and 0.3 logMAR respectively) with no significant difference for binocular depth of focus. LARA eyes had significantly better monocular depth of focus at all levels compared with ASPHINA eyes (all p < 0.0001), while there was no significant difference between Symfony and ASPHINA eyes at 0.1 logMAR and 0.2 logMAR. Both EDOF IOLs were significantly better than the monofocal ASPHINA at all levels for binocular depth of focus (LARA: all p < 0.0001; Symfony: all p = 0.002). Distance visual acuity was similar for all IOLs at 6 months; intermediate and near visual acuity were significantly better for the EDOF IOLs than for the monofocal (p < 0.0001). Refraction improved in all groups relative to baseline. Contrast sensitivity was higher with the CT ASPHINA 409MP but both EDOF lenses had a better spectacle independence rate. At 6 months, all IOLs were well centred with no cases of tilt. No general safety issues were raised for any of the groups. Conclusion: The two EDOF intraocular lenses investigated provided good visual outcomes with comparable visual acuity at all distances. The AT LARA 829MP provided the widest monocular depth of focus at 0.1 and 0.2 logMAR, with a clear superiority compared with the monofocal IOL. TECNIS Symfony was superior to the monofocal control at 0.3 logMAR. Spectacle independence and patient satisfaction were comparable. Trial registration: Trial registered on https://clinicaltrials.gov/ under the identification NCT03172351 (date of registration 1 June May 2017).


  • Flushing versus not flushing the interface during small-incision lenticule extraction

    by Ralf Kind, Laszlo Kiraly, Suphi Taneri, Leonie Troeber, Rainer Wiltfang, Martin Bechmann, Bertram Meyer, Brandon Greene, Walter Sekundo

    To assess the differences in outcomes between interface flushing with a balanced salt solution after refractive lenticule removal in simultaneous uneventful bilateral small-incision lenticule extraction (SMILE). Six study centers in Germany. Prospective case series. Patients with myopia or myopic astigmatism of similar magnitude in both eyes with a spherical equivalent less than or equal to 10.0 diopters (D), preoperative corrected distance visual acuity (CDVA) of 0.80 decimal or better, and anisometropia less than or equal to 2.0 D were enrolled and followed for 3 months. One eye of each patient was treated with interface flushing after dry extraction of the lenticule. Flushing was performed with 1.0 cc balanced salt solution using a single-use 27-gauge cannula. The uncorrected distance visual acuity (UDVA) at 1 day, 1 week, and 3 months; the CDVA at 3 months; and postoperative differences at the slitlamp examination were recorded. Statistical analyses were performed with logarithm of the minimum angle of resolution values using paired t tests. The P value for significance was less than 0.05. The study analyzed 470 eyes. One day postoperatively, the mean UDVA was 0.81 in the non-flush group and 0.83 in the flush group (P = .110). At the last visit 3 months postoperatively, the mean UDVA was 1.04 and 1.05, respectively (P = .172). No significant differences in the rate of postoperative complications were found. Interface irrigation with 1.0 cc of balanced salt solution after the removal of the refractive lenticule has neither advantages nor disadvantages in terms of visual recovery, postoperative complications, or final visual acuity.


  • Open Access

    Repeatability and Agreement of Central Corneal Thickness and Keratometry Measurements between Four Different Devices

    by Laszlo Kiraly, Jana Stange, Kathleen S. Kunert, Saadettin Sel

    Background.To estimate repeatability and comparability of central corneal thickness (CCT) and keratometry measurements obtained by four different devices in healthy eyes.Methods.Fifty-five healthy eyes from 55 volunteers were enrolled in this study. CCT (IOLMaster 700, Pentacam HR, and Cirrus HD-OCT) and keratometry readings (IOLMaster 700, Pentacam HR, and iDesign) were measured. For statistical analysis, the corneal spherocylinder was converted into power vectors (J0, J45). Repeatability was assessed by intraclass correlation coefficient (ICC). Agreement of measurements between the devices was evaluated by the Bland-Altman method.Results.The analysis of repeatability of CCT data of IOLMaster 700, Pentacam HR, and Cirrus HD-OCT showed high ICCs (range 0.995 to 0.999). The comparison of CCT measurements revealed statistically significant differences between Pentacam HR versus IOLMaster 700 (p<0.0001) and Pentacam HR versus Cirrus HD-OCT (p<0.0001), respectively. There was no difference in CCT measurements between IOLMaster 700 and Cirrus HD-OCT (p=0.519). The repeatability of keratometry readings (J0 and J45) of IOLMaster 700, Pentacam HR, and iDesign was also high with ICCs ranging from 0.974 to 0.999. The Pentacam HR revealed significantly higher J0 in comparison to IOLMaster 700 (p=0.009) and iDesign (p=0.041); however, no significant difference was between IOLMaster 700 and iDesign (p=0.426). Comparison of J45 showed no significant difference between IOLMaster 700, Pentacam HR, and iDesign. These results were in accordance with Bland-Altman plots.Conclusion.In clinical practice, the devices analyzed should not be used interchangeably due to low agreement regarding CCT as well as keratometry readings.


  • LASIK – Neulandbehandlung oder medizinischer Standard

    by L. Kiraly, P. Skarupinski, G. Duncker

    Einordnung der LASIK-Methode in der refraktiven Chirurgie und Kostenübernahme durch die Krankenkassen sowie Aufklärung durch den Arzt. In dieser Arbeit wird die aktuelle Studienlage und Rechtsprechung in Deutschland 2010 dargestellt. Classification of LASIK in refractive surgery and treatment by health insurance, and education by the physician. Results in clinical studies and case law in Germany 2010.


  • Korrektur des Astigmatismus nach Hornhauttransplantation durch bogenförmige Inzisionen mit dem Femtosekundenlaser

    by L. Kiraly, C. Herrmann, M. Amm, G. Duncker

    Ziel: Wir untersuchten die Wirksamkeit des Einsatzes des Femtosekundenlasers zur bogenförmigen Inzision bei hohem Astigmatismus nach Hornhauttransplantation. Hintergrund: Hoher Astigmatismus nach Hornhauttransplantation ist eine bekannte und häufig schwierig zu therapierende Komplikation. Derzeit sind eine Vielzahl von chirurgischen Interventionen bekannt, wenn eine kontaktologische Versorgung nicht gelingt. Patienten und Methoden: Hier sollen erste klinische Ergebnisse präsentiert werden. Wir behandelten zehn Patienten mit hohem Astigmatismus nach Hornhauttransplantation. Zum Einsatz kam der Femtosekundenlaser der Fa. Femtec®. Mit diesem Laser führten wir paarige bogenförmige Inzisionen im Transplantat durch. Mit dem Femtosekundenlaser ist es möglich, hochpräzise Inzisionen durchzuführen, wobei Schnitttiefe und Bogenlänge exakt programmiert und umgesetzt werden können. Ergebnisse: Der bestkorrigierte Visus konnte bei 8 von 10 Patienten verbessert werden. Bei zwei Patienten blieb der bestkorrigierte Visus auf dem gleichen Niveau. Der korneale Astigmatismus konnte im Mittel um 3 dpt reduziert werden. Der refraktive Astigmatismus wurde im Mittel um 4 dpt reduziert. Schlussfolgerung: Arkuate Inzisionen mit dem Femtosekundenlaser bei hohem Astigmatismus nach Hornhauttransplantation sind ein sicherer und wirksamer Eingriff. Aim: We examined the effectiveness of arcuate incisions by femtosecond laser treatment for high astigmatism in corneal transplants. Background: High astigmatism is a well known complication after corneal transplantation and is difficult to treat. At present, there are many surgical procedures for the correction of high astigmatism after PKP in case of an unsuccessful contact lens therapy. Patients and Methods: Ten patients with a high postoperative astigmatism underwent arcuate keratotomy with the Femtec® laser. We performed two arcuate incisions on each transplant. With the femtosecond laser technology it is possible to perform precise incisions where the depth and length of the arcus can be programmed. Results: The best corrected visual acuity was improved in eight out of ten patients. The visual acuity of two patients did not change. The average corneal astigmatism was reduced by three dioptres. The average refractive astigmatism was reduced by four dioptres. Conclusion: Arcuate incisions with the femtosecond laser on patients with high astigmatism subsequwent to corneal transplantation are an effective and safe treatment.