Hirotoshi Yasaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hirotoshi Yasaki has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Noritada Kaji
Department of Chemistry and Biochemistry, Graduate School of Engineering, Kyushu University
6 shared publicationsKazuki Nagashima
Laboratory of Integrated Nanostructure Materials Institute of Materials Chemistry and Engineering, Kyushu University
5 shared publicationsMasaki Kanai
Laboratory of Integrated Nanostructure Materials Institute of Materials Chemistry and Engineering, Kyushu University
5 shared publications- Yoshinobu Baba
Research Institute for Quantum and Chemical Innovation, Institutes of Innovation for Future Society, Nagoya University
5 shared publications Takao Yasui
Department of Biomolecular Engineering, Graduate School of Engineering, Nagoya University
4 shared publications- Takao Yasui
Department of Biomolecular Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
4 shared publications
Latest Publications
- 10 January 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (3) , 2483-2491
Mechanical Low-Pass Filtering of Cells for Detection of Circulating Tumor Cells in Whole Blood
The detection of circulating tumor cells (CTCs) from liquid biopsies using microfluidic devices is attracting a considerable amount of attention as a new, less-invasive cancer diagnostic and prognostic method. One of the drawbacks of the existing antibody-based detection systems is the false negatives for epithelial cell adhesion molecule detection of CTCs. Here, we report a mechanical low-pass filtering technique based on a microfluidic constriction and electrical current sensing system for the novel CTC detection in whole blood without any specific antigen-antibody interaction or biochemical modification of the cell surface. The mechanical response of model cells of CTCs, such as HeLa, A549, and MDA-MB-231 cells clearly demonstrated different behaviors from that of Jurkat cells, a human T-lymphocyte cell line, when they passed through the 6-μm wide constriction channel. A 6-μm wide constriction channel was determined as the optimum size to identify CTCs in whole blood with an accuracy greater than 95% in tens of milliseconds. The mechanical filtering of cells at a single cell level was achieved from a whole blood without any pretreatment (e.g. dilution of lysing) and pre-labeling (e.g. fluorophores or antibodies).
- 10 January 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (3) , 2483-2491
Mechanical Low-Pass Filtering of Cells for Detection of Circulating Tumor Cells in Whole Blood
The detection of circulating tumor cells (CTCs) from liquid biopsies using microfluidic devices is attracting a considerable amount of attention as a new, less-invasive cancer diagnostic and prognostic method. One of the drawbacks of the existing antibody-based detection systems is the false negatives for epithelial cell adhesion molecule detection of CTCs. Here, we report a mechanical low-pass filtering technique based on a microfluidic constriction and electrical current sensing system for the novel CTC detection in whole blood without any specific antigen-antibody interaction or biochemical modification of the cell surface. The mechanical response of model cells of CTCs, such as HeLa, A549, and MDA-MB-231 cells clearly demonstrated different behaviors from that of Jurkat cells, a human T-lymphocyte cell line, when they passed through the 6-μm wide constriction channel. A 6-μm wide constriction channel was determined as the optimum size to identify CTCs in whole blood with an accuracy greater than 95% in tens of milliseconds. The mechanical filtering of cells at a single cell level was achieved from a whole blood without any pretreatment (e.g. dilution of lysing) and pre-labeling (e.g. fluorophores or antibodies).
- 23 August 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (20) , 12890-12899
Microfluidic Mechanotyping of a Single Cell with Two Consecutive Constrictions of Different Sizes and an Electrical Detection System
The mechanical properties of a cell, which include parameters such as elasticity, inner pressure, and tensile strength, are extremely important because changes in these properties are indicative of disease ranging from diabetes to malignant transformation. Considering the heterogeneity within a population of cancer cells, a robust measurement system at the single cell level is required for research and in clinical purposes. In this study, a potential microfluidic device for high-throughput and practical mechanotyping were developed to investigate the deformability and sizes of cells through a single run. This mechanotyping device, consisted of two different sizes of consecutive constrictions in a microchannel, and measured the size of cells and related deformability during transit. Cell deformability was evaluated based on the transit, and the effects of cytoskeleton-affecting drugs which were detected within 50 ms. The mechanotyping device was able to also measure a cell cycle without the use of fluorescent or protein tags.
- 23 August 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (20) , 12890-12899
Microfluidic Mechanotyping of a Single Cell with Two Consecutive Constrictions of Different Sizes and an Electrical Detection System
The mechanical properties of a cell, which include parameters such as elasticity, inner pressure, and tensile strength, are extremely important because changes in these properties are indicative of disease ranging from diabetes to malignant transformation. Considering the heterogeneity within a population of cancer cells, a robust measurement system at the single cell level is required for research and in clinical purposes. In this study, a potential microfluidic device for high-throughput and practical mechanotyping were developed to investigate the deformability and sizes of cells through a single run. This mechanotyping device, consisted of two different sizes of consecutive constrictions in a microchannel, and measured the size of cells and related deformability during transit. Cell deformability was evaluated based on the transit, and the effects of cytoskeleton-affecting drugs which were detected within 50 ms. The mechanotyping device was able to also measure a cell cycle without the use of fluorescent or protein tags.
- 16 November 2018
- Published by Springer Nature in Analytical Sciences
- Vol. 34 (12) , 1347-1349
PM2.5 Particle Detection in a Microfluidic Device by Using Ionic Current Sensing
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 16 November 2018
- Published by Springer Nature in Analytical Sciences
- Vol. 34 (12) , 1347-1349
PM2.5 Particle Detection in a Microfluidic Device by Using Ionic Current Sensing
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- Open Access
- 1 May 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 260, 746-752
A real-time simultaneous measurement on a microfluidic device for individual bacteria discrimination
- 1 May 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 260, 746-752
Open AccessA real-time simultaneous measurement on a microfluidic device for individual bacteria discrimination
- 5 March 2018
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 47 (3) , 350-353
Effect of Channel Geometry on Ionic Current Signal of a Bridge Circuit Based Microfluidic Channel
Bridge circuit based ionic current sensing in a microfluidic channel has attracted attention as a highly sensitive analytical method for bio-related molecules and particles. However, channel geometry which greatly influences the detected ionic current has not been investigated. Here, we investigate experimentally and theoretically the effect of differences in the microfluidic channel geometry on shapes and amplitude of signals in ionic current sensing. Our results clarify the geometrical effect of the channel in the bridge circuit based ionic current sensing method. Bridge circuit based ionic current sensing in a microfluidic channel has attracted attention as a highly sensitive analytical method for bio-related molecules and particles. However, channel geometry which greatly influences the detected ionic current has not been investigated. Here, we investigate experimentally and theoretically the effect of differences of the microfluidic channel geometry on shapes and amplitude of signals in ionic current sensing. Our results clarify the geometrical effect of the channel in the bridge circuit based ionic current sensing method.
- 5 March 2018
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 47 (3) , 350-353
Effect of Channel Geometry on Ionic Current Signal of a Bridge Circuit Based Microfluidic Channel
Bridge circuit based ionic current sensing in a microfluidic channel has attracted attention as a highly sensitive analytical method for bio-related molecules and particles. However, channel geometry which greatly influences the detected ionic current has not been investigated. Here, we investigate experimentally and theoretically the effect of differences in the microfluidic channel geometry on shapes and amplitude of signals in ionic current sensing. Our results clarify the geometrical effect of the channel in the bridge circuit based ionic current sensing method. Bridge circuit based ionic current sensing in a microfluidic channel has attracted attention as a highly sensitive analytical method for bio-related molecules and particles. However, channel geometry which greatly influences the detected ionic current has not been investigated. Here, we investigate experimentally and theoretically the effect of differences of the microfluidic channel geometry on shapes and amplitude of signals in ionic current sensing. Our results clarify the geometrical effect of the channel in the bridge circuit based ionic current sensing method.
- Open Access
- 8 February 2018
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 3 (3) , 574-579
Robust Ionic Current Sensor for Bacterial Cell Size Detection
Ionic current sensing methods are useful tools for detecting sub- to several-micron scale particles such as bacteria. However, conventional commercially available ionic current sensing devices are not suitable for on-site measurement use because of inherent limitations on their robustness. Here, we proposed a portable robust ionic current sensor (Robust-ICS) using a bridge circuit that offers a high signal-to-noise (S/N) ratio by suppressing background current. Because the Robust-ICS can tolerate increased noise in current sensing, a simple, lightweight electromagnetic shield can be used and measurements under large electromagnetic noise conditions can be made. The weight of the device was lowered below 4 kg and outdoor particle detection measurements were completed successfully. Accuracy of size detection of Staphylococcus aureus (S. aureus) was equivalent to that obtained by SEM imaging.
- 8 February 2018
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 3 (3) , 574-579
Open AccessRobust Ionic Current Sensor for Bacterial Cell Size Detection
Ionic current sensing methods are useful tools for detecting sub- to several-micron scale particles such as bacteria. However, conventional commercially available ionic current sensing devices are not suitable for on-site measurement use because of inherent limitations on their robustness. Here, we proposed a portable robust ionic current sensor (Robust-ICS) using a bridge circuit that offers a high signal-to-noise (S/N) ratio by suppressing background current. Because the Robust-ICS can tolerate increased noise in current sensing, a simple, lightweight electromagnetic shield can be used and measurements under large electromagnetic noise conditions can be made. The weight of the device was lowered below 4 kg and outdoor particle detection measurements were completed successfully. Accuracy of size detection of Staphylococcus aureus (S. aureus) was equivalent to that obtained by SEM imaging.
- Open Access
- 29 September 2017
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 139 (40) , 14137-14142
Substantial Expansion of Detectable Size Range in Ionic Current Sensing through Pores by Using a Microfluidic Bridge Circuit
Measuring ionic currents passing through nano- or micropores has shown great promise for the electrical discrimination of various biomolecules, cells, bacteria, and viruses. However, conventional measurements have shown there is an inherent limitation to the detectable particle volume (1% of the pore volume), which critically hinders applications to real mixtures of biomolecule samples with a wide size range of suspended particles. Here we propose a rational methodology that can detect samples with the detectable particle volume of 0.01% of the pore volume by measuring a transient current generated from the potential differences in a microfluidic bridge circuit. Our method substantially suppresses the background ionic current from the μA level to the pA level, which essentially lowers the detectable particle volume limit even for relatively large pore structures. Indeed, utilizing a microscale long pore structure (volume of 5.6 × 104 aL; height and width of 2.0 × 2.0 μm; length of 14 μm), we successfully detected various samples including polystyrene nanoparticles (volume: 4 aL), bacteria, cancer cells, and DNA molecules. Our method will expand the applicability of ionic current sensing systems for various mixed biomolecule samples with a wide size range, which have been difficult to measure by previously existing pore technologies.
- 29 September 2017
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 139 (40) , 14137-14142
Open AccessSubstantial Expansion of Detectable Size Range in Ionic Current Sensing through Pores by Using a Microfluidic Bridge Circuit
Measuring ionic currents passing through nano- or micropores has shown great promise for the electrical discrimination of various biomolecules, cells, bacteria, and viruses. However, conventional measurements have shown there is an inherent limitation to the detectable particle volume (1% of the pore volume), which critically hinders applications to real mixtures of biomolecule samples with a wide size range of suspended particles. Here we propose a rational methodology that can detect samples with the detectable particle volume of 0.01% of the pore volume by measuring a transient current generated from the potential differences in a microfluidic bridge circuit. Our method substantially suppresses the background ionic current from the μA level to the pA level, which essentially lowers the detectable particle volume limit even for relatively large pore structures. Indeed, utilizing a microscale long pore structure (volume of 5.6 × 104 aL; height and width of 2.0 × 2.0 μm; length of 14 μm), we successfully detected various samples including polystyrene nanoparticles (volume: 4 aL), bacteria, cancer cells, and DNA molecules. Our method will expand the applicability of ionic current sensing systems for various mixed biomolecule samples with a wide size range, which have been difficult to measure by previously existing pore technologies.
- 26 September 2014
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (1) , 135-140
Microfluidic transfer of liquid interface for parallel stretching and stamping of terminal-unmodified single DNA molecules in zigzag-shaped microgrooves
On-chip stretching and aligning of single DNA molecules were demonstrated using microfluidic transfer of liquid interface in zigzag-shaped microgrooves.
- 26 September 2014
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (1) , 135-140
Microfluidic transfer of liquid interface for parallel stretching and stamping of terminal-unmodified single DNA molecules in zigzag-shaped microgrooves
On-chip stretching and aligning of single DNA molecules were demonstrated using microfluidic transfer of liquid interface in zigzag-shaped microgrooves.