Aristides M. Bonanos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Aristides M. Bonanos has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Evgenii V. Votyakov
CYENS Centre of Excellence, Nicosia, Cyprus
4 shared publications - Jeffrey M. Bergthorson
Department of Mechanical Engineering, McGill University, Montréal, QC H3A 0G4, Canada
4 shared publications - Marios D. Georgiou
Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801
4 shared publications Paul E. Dimotakis
Graduate Aeronautical Laboratories, California Institute of Technology, Pasadena, CA 91125, USA
4 shared publicationsM.C. Georgiou
3 shared publicationsPaul Dimotakis
California Institute of Technology
3 shared publications
Latest Publications
- Open Access
- 1 November 2019
- Published by Elsevier in Renewable Energy
- Vol. 142, 30-40
Heliostat surface shape characterization for accurate flux prediction
- 1 November 2019
- Published by Elsevier in Renewable Energy
- Vol. 142, 30-40
Open AccessHeliostat surface shape characterization for accurate flux prediction
- Open Access
- 1 May 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 154, 294-301
Engineering aspects and thermal performance of molten salt transfer lines in solar power applications
- 1 May 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 154, 294-301
Open AccessEngineering aspects and thermal performance of molten salt transfer lines in solar power applications
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2033, 040008
Optical characterization of heliostats using multiple 3D geometry characterization sensors
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2033, 040008
Optical characterization of heliostats using multiple 3D geometry characterization sensors
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2033, 210019
The control system at PROTEAS
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2033, 210019
The control system at PROTEAS
- 1 June 2017
- Published by Elsevier in Desalination
- Vol. 412, 13-19
Physical modeling of thermo-compressor for desalination applications
- 1 June 2017
- Published by Elsevier in Desalination
- Vol. 412, 13-19
Physical modeling of thermo-compressor for desalination applications
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1850, 170001
CSP+D: The case study at the PROTEAS facility
The PROTEAS facility, located on the southern coastline of Cyprus, hosts an experiment aiming to investigate the co-generation of electricity and desalinated seawater from concentrated solar power, providing a unique opportunity to test on a pilot-scale the CSP+D co-generation scheme. In the present paper, heat sources that would otherwise be rejected to the environment are explored along with their potential thermal contribution, and the performance of a thermal distillation unit utilizing these sources is investigated. Several low-temperature heat sources are available to be used for seawater preheating, whereas the novelty of the design of the receiver allows for its thermal losses to be harnessed and used to drive the desalination cycle.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1850, 170001
CSP+D: The case study at the PROTEAS facility
The PROTEAS facility, located on the southern coastline of Cyprus, hosts an experiment aiming to investigate the co-generation of electricity and desalinated seawater from concentrated solar power, providing a unique opportunity to test on a pilot-scale the CSP+D co-generation scheme. In the present paper, heat sources that would otherwise be rejected to the environment are explored along with their potential thermal contribution, and the performance of a thermal distillation unit utilizing these sources is investigated. Several low-temperature heat sources are available to be used for seawater preheating, whereas the novelty of the design of the receiver allows for its thermal losses to be harnessed and used to drive the desalination cycle.
- 1 December 2016
- Published by Elsevier in Renewable Energy
- Vol. 99, 764-771
Sensitivity analysis for thermocline thermal storage tank design
- 1 December 2016
- Published by Elsevier in Renewable Energy
- Vol. 99, 764-771
Sensitivity analysis for thermocline thermal storage tank design
- 20 September 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (1) , 012503
Experimental Investigation of Transitional Natural Convection in a Cube Using Particle Image Velocimetry—Part II: Turbulence Quantities and Proper Orthogonal Decomposition
An experimental investigation of transitional natural convection in an air filled cube was conducted in this research. The characteristic dimension of the enclosure was H = 0.35 m, and data were collected in the middle plane of the cavity. The Rayleigh number range examined was 5.0×107≤Ra≤3.4×108. In Part I, the authors presented the mean velocity profiles in the enclosure and conducted heat transfer measurements on the hot wall. An expression between Nu and Ra numbers was concluded and compared against other correlations available in literature. In the present work, the authors present a complete description of the flow in the enclosure by quantifying the low turbulence regime developed in the cavity. This was accomplished by estimating Reynolds stresses, turbulent kinetic energy, vorticity, and swirling strength. Proper orthogonal decomposition (POD) was employed to analyze the flow fields obtained from the experimental data and retain the most salient features of the flow field. This study attempts to close the gap of available experimental data in the literature and provide experimental benchmark data that can be used to validate CFD codes since the estimated error from particle image velocimetry (PIV) measurements is within 1–2%.
- 20 September 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (1) , 012503
Experimental Investigation of Transitional Natural Convection in a Cube Using Particle Image Velocimetry—Part II: Turbulence Quantities and Proper Orthogonal Decomposition
An experimental investigation of transitional natural convection in an air filled cube was conducted in this research. The characteristic dimension of the enclosure was H = 0.35 m, and data were collected in the middle plane of the cavity. The Rayleigh number range examined was 5.0×107≤Ra≤3.4×108. In Part I, the authors presented the mean velocity profiles in the enclosure and conducted heat transfer measurements on the hot wall. An expression between Nu and Ra numbers was concluded and compared against other correlations available in literature. In the present work, the authors present a complete description of the flow in the enclosure by quantifying the low turbulence regime developed in the cavity. This was accomplished by estimating Reynolds stresses, turbulent kinetic energy, vorticity, and swirling strength. Proper orthogonal decomposition (POD) was employed to analyze the flow fields obtained from the experimental data and retain the most salient features of the flow field. This study attempts to close the gap of available experimental data in the literature and provide experimental benchmark data that can be used to validate CFD codes since the estimated error from particle image velocimetry (PIV) measurements is within 1–2%.
- 20 September 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (1) , 012502
Experimental Investigation of Transitional Natural Convection in a Cube Using Particle Image Velocimetry—Part I: Fluid Flow and Thermal Fields
An experimental investigation of transitional natural convection in an air filled cube was conducted in this research. The characteristic dimension of the enclosure is 0.35 m, and data were collected in the middle plane of the cavity. The Rayleigh number range examined is 5.0×107≤Ra≤3.4×108. This was achieved by varying the temperature on the hot and cold walls. The velocity field in the middle plane is measured using particle image velocimetry (PIV). Temperature measurements in the core of the enclosure indicate a linear profile. The average Nu number is also presented and compared against other correlations in the literature. This study attempts to close the gap of available experimental data in literature and provide experimental benchmark data that can be used to validate computational fluid dynamics (CFD) codes since the estimated error from PIV measurements is within 1–2%.
- 20 September 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (1) , 012502
Experimental Investigation of Transitional Natural Convection in a Cube Using Particle Image Velocimetry—Part I: Fluid Flow and Thermal Fields
An experimental investigation of transitional natural convection in an air filled cube was conducted in this research. The characteristic dimension of the enclosure is 0.35 m, and data were collected in the middle plane of the cavity. The Rayleigh number range examined is 5.0×107≤Ra≤3.4×108. This was achieved by varying the temperature on the hot and cold walls. The velocity field in the middle plane is measured using particle image velocimetry (PIV). Temperature measurements in the core of the enclosure indicate a linear profile. The average Nu number is also presented and compared against other correlations in the literature. This study attempts to close the gap of available experimental data in literature and provide experimental benchmark data that can be used to validate computational fluid dynamics (CFD) codes since the estimated error from PIV measurements is within 1–2%.
- Open Access
- 9 May 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (48-49) , 23119-23131
A transient model for forward and parallel feed MED
The aim of this paper is to investigate the performance of a multiple effect distillation (MED) unit potentially coupled to a concentrated solar power plant and validate the results with the predictions of a dynamic model that was developed for this purpose. A small-scale (10 kWthermal) four effect distillation system was designed and built to demonstrate proof of principle of the concentrating solar power–desalinating sea water system integration. In order to fully characterize this small-scale MED unit, an understanding of the performance for steady state and transient conditions is required. Initially experiments were performed in a steady state situation, various parameters were examined and the experimental findings have already been published. After the initial experimental findings of the steady state operation, the performance of this unit was also investigated for transient conditions. The experimental procedure followed was identical as in the steady state conditions, with the main difference being the variation in the heat input supply to the system as a function of time. For the present study, the heat input supplied to the unit varied between 5 and 10 kWthermal. At the same time, a dynamic model was also developed in order to predict the performance of this unit in consecutive time steps of operation. The performance was calculated in terms of performance ratio (the ratio of the distillate product flow rate to the feeding steam flow rate) and the model results were validated against the experimental findings. The results showed that there is a really good match between the experimental data and the predicted ones from the model.
- 9 May 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (48-49) , 23119-23131
Open AccessA transient model for forward and parallel feed MED
The aim of this paper is to investigate the performance of a multiple effect distillation (MED) unit potentially coupled to a concentrated solar power plant and validate the results with the predictions of a dynamic model that was developed for this purpose. A small-scale (10 kWthermal) four effect distillation system was designed and built to demonstrate proof of principle of the concentrating solar power–desalinating sea water system integration. In order to fully characterize this small-scale MED unit, an understanding of the performance for steady state and transient conditions is required. Initially experiments were performed in a steady state situation, various parameters were examined and the experimental findings have already been published. After the initial experimental findings of the steady state operation, the performance of this unit was also investigated for transient conditions. The experimental procedure followed was identical as in the steady state conditions, with the main difference being the variation in the heat input supply to the system as a function of time. For the present study, the heat input supplied to the unit varied between 5 and 10 kWthermal. At the same time, a dynamic model was also developed in order to predict the performance of this unit in consecutive time steps of operation. The performance was calculated in terms of performance ratio (the ratio of the distillate product flow rate to the feeding steam flow rate) and the model results were validated against the experimental findings. The results showed that there is a really good match between the experimental data and the predicted ones from the model.