Dong Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dong Wang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoping Yang
Nanjing University
2 shared publications - Yanan Gu
School of Computer Science and Technology, Henan Polytechnic University, Jiaozuo, China
2 shared publications - Bibo Lu
School of Computer Science and Technology, Henan Polytechnic University, Jiaozuo, China
1 shared publication - Chenchen Liu
Henan Polytechnic University, Henan, China
1 shared publication Chong Jiang
Sichuan University
1 shared publicationDavid S. Smith
Institute of Imaging Science Vanderbilt University Medical Center Nashville Tennessee USA
1 shared publication
Latest Publications
- 9 February 2026
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 45 (8) , 1-25
BRFNet: Bandwise Rectangle Attention Fusion Network for Image Dehazing
- 9 February 2026
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 45 (8) , 1-25
BRFNet: Bandwise Rectangle Attention Fusion Network for Image Dehazing
- 30 October 2024
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 138
Spatially adaptive oscillation total generalized variation for image restoration with structured textures
- 30 October 2024
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 138
Spatially adaptive oscillation total generalized variation for image restoration with structured textures
- 4 January 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (2) , 025001
M 3 S-Net: multi-modality multi-branch multi-self-attention network with structure-promoting loss for low-dose PET/CT enhancement
Objective. PET (Positron Emission Tomography) inherently involves radiotracer injections and long scanning time, which raises concerns about the risk of radiation exposure and patient comfort. Reductions in radiotracer dosage and acquisition time can lower the potential risk and improve patient comfort, respectively, but both will also reduce photon counts and hence degrade the image quality. Therefore, it is of interest to improve the quality of low-dose PET images. Approach. A supervised multi-modality deep learning model, named M 3 S-Net, was proposed to generate standard-dose PET images (60 s per bed position) from low-dose ones (10 s per bed position) and the corresponding CT images. Specifically, we designed a multi-branch convolutional neural network with multi-self-attention mechanisms, which first extracted features from PET and CT images in two separate branches and then fused the features to generate the final generated PET images. Moreover, a novel multi-modality structure-promoting term was proposed in the loss function to learn the anatomical information contained in CT images. Main results. We conducted extensive numerical experiments on real clinical data collected from local hospitals. Compared with state-of-the-art methods, the proposed M 3 S-Net not only achieved higher objective metrics and better generated tumors, but also performed better in preserving edges and suppressing noise and artifacts. Significance. The experimental results of quantitative metrics and qualitative displays demonstrate that the proposed M 3 S-Net can generate high-quality PET images from low-dose ones, which are competable to standard-dose PET images. This is valuable in reducing PET acquisition time and has potential applications in dynamic PET imaging.
- 4 January 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (2) , 025001
M 3 S-Net: multi-modality multi-branch multi-self-attention network with structure-promoting loss for low-dose PET/CT enhancement
Objective. PET (Positron Emission Tomography) inherently involves radiotracer injections and long scanning time, which raises concerns about the risk of radiation exposure and patient comfort. Reductions in radiotracer dosage and acquisition time can lower the potential risk and improve patient comfort, respectively, but both will also reduce photon counts and hence degrade the image quality. Therefore, it is of interest to improve the quality of low-dose PET images. Approach. A supervised multi-modality deep learning model, named M 3 S-Net, was proposed to generate standard-dose PET images (60 s per bed position) from low-dose ones (10 s per bed position) and the corresponding CT images. Specifically, we designed a multi-branch convolutional neural network with multi-self-attention mechanisms, which first extracted features from PET and CT images in two separate branches and then fused the features to generate the final generated PET images. Moreover, a novel multi-modality structure-promoting term was proposed in the loss function to learn the anatomical information contained in CT images. Main results. We conducted extensive numerical experiments on real clinical data collected from local hospitals. Compared with state-of-the-art methods, the proposed M 3 S-Net not only achieved higher objective metrics and better generated tumors, but also performed better in preserving edges and suppressing noise and artifacts. Significance. The experimental results of quantitative metrics and qualitative displays demonstrate that the proposed M 3 S-Net can generate high-quality PET images from low-dose ones, which are competable to standard-dose PET images. This is valuable in reducing PET acquisition time and has potential applications in dynamic PET imaging.
- Open Access
- 22 November 2023
- Published by MDPI AG in Electronics
- Vol. 12 (23) , 4743
CMP-UNet: A Retinal Vessel Segmentation Network Based on Multi-Scale Feature Fusion
Retinal vessel segmentation plays a critical role in the diagnosis and treatment of various ophthalmic diseases. However, due to poor image contrast, intricate vascular structures, and limited datasets, retinal vessel segmentation remains a long-term challenge. In this paper, based on an encoder–decoder framework, a novel retinal vessel segmentation model called CMP-UNet is proposed. Firstly, the Coarse and Fine Feature Aggregation module decouples and aggregates coarse and fine vessel features using two parallel branches, thus enhancing the model’s ability to extract features for vessels of various sizes. Then, the Multi-Scale Channel Adaptive Fusion module is embedded in the decoder to realize the efficient fusion of cascade features by mining the multi-scale context information from these features. Finally, to obtain more discriminative vascular features and enhance the connectivity of vascular structures, the Pyramid Feature Fusion module is proposed to effectively utilize the complementary information of multi-level features. To validate the effectiveness of the proposed model, it is evaluated on three publicly available retinal vessel segmentation datasets: CHASE_DB1, DRIVE, and STARE. The proposed model, CMP-UNet, reaches F1-scores of 82.84%, 82.55%, and 84.14% on these three datasets, with improvements of 0.76%, 0.31%, and 1.49%, respectively, compared with the baseline. The results show that the proposed model achieves higher segmentation accuracy and more robust generalization capability than state-of-the-art methods.
- 22 November 2023
- Published by MDPI AG in Electronics
- Vol. 12 (23) , 4743
Open AccessCMP-UNet: A Retinal Vessel Segmentation Network Based on Multi-Scale Feature Fusion
Retinal vessel segmentation plays a critical role in the diagnosis and treatment of various ophthalmic diseases. However, due to poor image contrast, intricate vascular structures, and limited datasets, retinal vessel segmentation remains a long-term challenge. In this paper, based on an encoder–decoder framework, a novel retinal vessel segmentation model called CMP-UNet is proposed. Firstly, the Coarse and Fine Feature Aggregation module decouples and aggregates coarse and fine vessel features using two parallel branches, thus enhancing the model’s ability to extract features for vessels of various sizes. Then, the Multi-Scale Channel Adaptive Fusion module is embedded in the decoder to realize the efficient fusion of cascade features by mining the multi-scale context information from these features. Finally, to obtain more discriminative vascular features and enhance the connectivity of vascular structures, the Pyramid Feature Fusion module is proposed to effectively utilize the complementary information of multi-level features. To validate the effectiveness of the proposed model, it is evaluated on three publicly available retinal vessel segmentation datasets: CHASE_DB1, DRIVE, and STARE. The proposed model, CMP-UNet, reaches F1-scores of 82.84%, 82.55%, and 84.14% on these three datasets, with improvements of 0.76%, 0.31%, and 1.49%, respectively, compared with the baseline. The results show that the proposed model achieves higher segmentation accuracy and more robust generalization capability than state-of-the-art methods.
- Open Access
- 5 November 2023
- Published by Elsevier in IBRO Neuroscience Reports
- Vol. 15, S693-S694
10KHZ SCS RESTORES MECHANICAL AND THERMAL NEURAL PROCESSING IN A RODENT MODEL OF PAINFUL DIABETIC NEUROPATHY
- 5 November 2023
- Published by Elsevier in IBRO Neuroscience Reports
- Vol. 15, S693-S694
Open Access10KHZ SCS RESTORES MECHANICAL AND THERMAL NEURAL PROCESSING IN A RODENT MODEL OF PAINFUL DIABETIC NEUROPATHY
- Open Access
- 1 February 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 66, 248-256
snapMRF: GPU-accelerated magnetic resonance fingerprinting dictionary generation and matching using extended phase graphs
- 1 February 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 66, 248-256
Open AccesssnapMRF: GPU-accelerated magnetic resonance fingerprinting dictionary generation and matching using extended phase graphs
- 7 November 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (6) , 2064-2076
Dynamic MR image reconstruction based on total generalized variation and low‐rank decomposition
Purpose: Propose a novel decomposition‐based model employing the total generalized variation (TGV) and the nuclear norm, which can be used in compressed sensing‐based dynamic MR reconstructions.Theory and Methods: We employ the nuclear norm to represent the time‐coherent background and the spatiotemporal TGV functional for the sparse dynamic component above. We first design an algorithm using the classical first‐order primal‐dual method for solving the proposed model and then give the norm estimation for the convergence condition. The proposed model is compared with the state‐of‐the‐art methods on different data sets under different sampling schemes and acceleration factors.Results: The proposed model achieves higher SERs and SSIMs than kt‐SLR, kt‐RPCA, L+S, and ICTGV on cardiac perfusion and breast DCE‐MRI data sets under both the pseudoradial and the Cartesian sampling schemes. In addition, the proposed model better suppresses the spatial artifacts and preserves the edges.Conclusions: The proposed model outperforms the state‐of‐the‐art methods and generates high‐quality reconstructions under different sampling schemes and different acceleration factors.
- 7 November 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (6) , 2064-2076
Dynamic MR image reconstruction based on total generalized variation and low‐rank decomposition
Purpose: Propose a novel decomposition‐based model employing the total generalized variation (TGV) and the nuclear norm, which can be used in compressed sensing‐based dynamic MR reconstructions.Theory and Methods: We employ the nuclear norm to represent the time‐coherent background and the spatiotemporal TGV functional for the sparse dynamic component above. We first design an algorithm using the classical first‐order primal‐dual method for solving the proposed model and then give the norm estimation for the convergence condition. The proposed model is compared with the state‐of‐the‐art methods on different data sets under different sampling schemes and acceleration factors.Results: The proposed model achieves higher SERs and SSIMs than kt‐SLR, kt‐RPCA, L+S, and ICTGV on cardiac perfusion and breast DCE‐MRI data sets under both the pseudoradial and the Cartesian sampling schemes. In addition, the proposed model better suppresses the spatial artifacts and preserves the edges.Conclusions: The proposed model outperforms the state‐of‐the‐art methods and generates high‐quality reconstructions under different sampling schemes and different acceleration factors.
- Open Access
- 28 August 2017
- Published by Wiley in International Journal of Biomedical Imaging
- Vol. 2017, 1-11
Quantitative Evaluation of Temporal Regularizers in Compressed Sensing Dynamic Contrast Enhanced MRI of the Breast
Purpose. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is used in cancer imaging to probe tumor vascular properties. Compressed sensing (CS) theory makes it possible to recover MR images from randomly undersampled -space data using nonlinear recovery schemes. The purpose of this paper is to quantitatively evaluate common temporal sparsity-promoting regularizers for CS DCE-MRI of the breast. Methods. We considered five ubiquitous temporal regularizers on 4.5x retrospectively undersampled Cartesian in vivo breast DCE-MRI data: Fourier transform (FT), Haar wavelet transform (WT), total variation (TV), second-order total generalized variation (), and nuclear norm (NN). We measured the signal-to-error ratio (SER) of the reconstructed images, the error in tumor mean, and concordance correlation coefficients (CCCs) of the derived pharmacokinetic parameters (volume transfer constant) and (extravascular-extracellular volume fraction) across a population of random sampling schemes. Results. NN produced the lowest image error (SER: 29.1), while produced the most accurate (CCC: 0.974/0.974) and (CCC: 0.916/0.917). WT produced the highest image error (SER: 21.8), while FT produced the least accurate (CCC: 0.842) and (CCC: 0.799). Conclusion. should be used as temporal constraints for CS DCE-MRI of the breast.- 28 August 2017
- Published by Wiley in International Journal of Biomedical Imaging
- Vol. 2017, 1-11
Open AccessQuantitative Evaluation of Temporal Regularizers in Compressed Sensing Dynamic Contrast Enhanced MRI of the Breast
Purpose. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is used in cancer imaging to probe tumor vascular properties. Compressed sensing (CS) theory makes it possible to recover MR images from randomly undersampled -space data using nonlinear recovery schemes. The purpose of this paper is to quantitatively evaluate common temporal sparsity-promoting regularizers for CS DCE-MRI of the breast. Methods. We considered five ubiquitous temporal regularizers on 4.5x retrospectively undersampled Cartesian in vivo breast DCE-MRI data: Fourier transform (FT), Haar wavelet transform (WT), total variation (TV), second-order total generalized variation (), and nuclear norm (NN). We measured the signal-to-error ratio (SER) of the reconstructed images, the error in tumor mean, and concordance correlation coefficients (CCCs) of the derived pharmacokinetic parameters (volume transfer constant) and (extravascular-extracellular volume fraction) across a population of random sampling schemes. Results. NN produced the lowest image error (SER: 29.1), while produced the most accurate (CCC: 0.974/0.974) and (CCC: 0.916/0.917). WT produced the highest image error (SER: 21.8), while FT produced the least accurate (CCC: 0.842) and (CCC: 0.799). Conclusion. should be used as temporal constraints for CS DCE-MRI of the breast.