Min Seob Sim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Min Seob Sim has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Tae Gun Shin
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
22 shared publications - Ik Joon Jo
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
18 shared publications - Won Chul Cha
Department of Digital Health, Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Sungkyunkwan University, Seoul 06355, Republic of Korea
15 shared publications - Hee Yoon
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
13 shared publications - Sung Yeon Hwang
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
13 shared publications - Taerim Kim
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
12 shared publications
Latest Publications
- Open Access
- 30 September 2022
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 9 (3) , 176-186
Prediction of vasopressor requirement among hypotensive patients with suspected infection: usefulness of diastolic shock index and lactate
Objective We evaluated the performance of diastolic shock index (DSI) and lactate in predicting vasopressor requirement among hypotensive patients with suspected infection in an emergency department.Methods This was a single-center, retrospective observational study for adult patients with suspected infection and hypotension in the emergency department from 2018 to 2019. The study population was split into derivation and validation cohorts (70/30). We derived a simple risk score to predict vasopressor requirement using DSI and lactate cutoff values determined by Youden index. We tested the score by the area under the receiver operating characteristic curve (AUC). We performed a multivariable regression analysis to evaluate the association between the timing of vasopressor treatment and 28-day mortality.Results A total of 1,917 patients were included. We developed a score, assigning 1 point each for the high DSI (≥2.0) and high lactate (≥2.5 mmol/L) criteria. The AUCs of the score were 0.741 (95% confidence interval [CI], 0.715–0.768) at hypotension and 0.736 (95% CI, 0.708–0.763) after initial fluid challenge in the derivation cohort and 0.676 (95% CI, 0.631–0.719) at hypotension and 0.688 (95% CI, 0.642–0.733) after initial fluid challenge in the validation cohort, respectively. In patients with scores of 2 points, early vasopressor therapy initiation was significantly associated with decreased 28-day mortality (adjusted odds ratio, 0.37; 95% CI, 0.14–0.94).Conclusion A prediction model with DSI and lactate levels might be useful to identify patients who are more likely to need vasopressor administration among hypotensive patients with suspected infection.
- 30 September 2022
- Published by The Korean Society of Emergency Medicine in Clinical and Experimental Emergency Medicine
- Vol. 9 (3) , 176-186
Open AccessPrediction of vasopressor requirement among hypotensive patients with suspected infection: usefulness of diastolic shock index and lactate
Objective We evaluated the performance of diastolic shock index (DSI) and lactate in predicting vasopressor requirement among hypotensive patients with suspected infection in an emergency department.Methods This was a single-center, retrospective observational study for adult patients with suspected infection and hypotension in the emergency department from 2018 to 2019. The study population was split into derivation and validation cohorts (70/30). We derived a simple risk score to predict vasopressor requirement using DSI and lactate cutoff values determined by Youden index. We tested the score by the area under the receiver operating characteristic curve (AUC). We performed a multivariable regression analysis to evaluate the association between the timing of vasopressor treatment and 28-day mortality.Results A total of 1,917 patients were included. We developed a score, assigning 1 point each for the high DSI (≥2.0) and high lactate (≥2.5 mmol/L) criteria. The AUCs of the score were 0.741 (95% confidence interval [CI], 0.715–0.768) at hypotension and 0.736 (95% CI, 0.708–0.763) after initial fluid challenge in the derivation cohort and 0.676 (95% CI, 0.631–0.719) at hypotension and 0.688 (95% CI, 0.642–0.733) after initial fluid challenge in the validation cohort, respectively. In patients with scores of 2 points, early vasopressor therapy initiation was significantly associated with decreased 28-day mortality (adjusted odds ratio, 0.37; 95% CI, 0.14–0.94).Conclusion A prediction model with DSI and lactate levels might be useful to identify patients who are more likely to need vasopressor administration among hypotensive patients with suspected infection.
- Open Access
- 13 September 2022
- Published by JMIR Publications Inc. in Interactive Journal of Medical Research
- Vol. 11 (2) , e36335
Intervention in the Timeliness of Two Electrocardiography Types for Patients in the Emergency Department With Chest Pain: Randomized Controlled Trial
Background: In the emergency department (ED), the result obtained using the 12-lead electrocardiography (ECG) is the basis for diagnosing and treating patients with chest pain. It was found that performing ECG at the appropriate time could improve treatment outcomes. Hence, a wearable ECG device with a timer can ensure that the findings are continuously recorded. Objective: We aimed to compare the time accuracy of a single-patch 12-lead ECG (SP-ECG) with that of conventional ECG (C-ECG). We hypothesized that SP-ECG would result in better time accuracy. Methods: Adult patients who visited the emergency room with chest pain but were not in shock were randomly assigned to one of the following 2 groups: the SP-ECG group or the C-ECG group. The final analysis included 33 (92%) of the 36 patients recruited. The primary outcome was the comparison of the time taken by the 2 groups to record the ECG. The average ages of the participants in the SP-ECG and C-ECG groups were 63.7 (SD 18.4) and 58.1 (SD 12.4) years, respectively. Results: With a power of 0.95 and effect sizes of 0.05 and 1.36, the minimum number of samples was calculated. The minimum sample size for each SP-ECG and C-ECG group is 15.36 participants, assuming a 20% dropout rate. As a result, 36 patients with chest pain participated, and 33 of them were analyzed. The timeliness of SP-ECG and C-ECG for the first follow-up ECG was 87.5% and 47.0%, respectively (P=.74). It was 75.0% and 35.2% at the second follow-up, respectively (P=.71). Conclusions: Continuous ECG monitoring with minimal interference from other examinations is feasible and essential in complex ED situations. However, the precision of SP-ECG has not yet been proved. Nevertheless, the application of SP-ECG is expected to improve overcrowding and human resource shortages in EDs, though more research is needed. Trial Registration: ClinicalTrials.gov NCT04114760; https://clinicaltrials.gov/ct2/show/NCT04114760
- 13 September 2022
- Published by JMIR Publications Inc. in Interactive Journal of Medical Research
- Vol. 11 (2) , e36335
Open AccessIntervention in the Timeliness of Two Electrocardiography Types for Patients in the Emergency Department With Chest Pain: Randomized Controlled Trial
Background: In the emergency department (ED), the result obtained using the 12-lead electrocardiography (ECG) is the basis for diagnosing and treating patients with chest pain. It was found that performing ECG at the appropriate time could improve treatment outcomes. Hence, a wearable ECG device with a timer can ensure that the findings are continuously recorded. Objective: We aimed to compare the time accuracy of a single-patch 12-lead ECG (SP-ECG) with that of conventional ECG (C-ECG). We hypothesized that SP-ECG would result in better time accuracy. Methods: Adult patients who visited the emergency room with chest pain but were not in shock were randomly assigned to one of the following 2 groups: the SP-ECG group or the C-ECG group. The final analysis included 33 (92%) of the 36 patients recruited. The primary outcome was the comparison of the time taken by the 2 groups to record the ECG. The average ages of the participants in the SP-ECG and C-ECG groups were 63.7 (SD 18.4) and 58.1 (SD 12.4) years, respectively. Results: With a power of 0.95 and effect sizes of 0.05 and 1.36, the minimum number of samples was calculated. The minimum sample size for each SP-ECG and C-ECG group is 15.36 participants, assuming a 20% dropout rate. As a result, 36 patients with chest pain participated, and 33 of them were analyzed. The timeliness of SP-ECG and C-ECG for the first follow-up ECG was 87.5% and 47.0%, respectively (P=.74). It was 75.0% and 35.2% at the second follow-up, respectively (P=.71). Conclusions: Continuous ECG monitoring with minimal interference from other examinations is feasible and essential in complex ED situations. However, the precision of SP-ECG has not yet been proved. Nevertheless, the application of SP-ECG is expected to improve overcrowding and human resource shortages in EDs, though more research is needed. Trial Registration: ClinicalTrials.gov NCT04114760; https://clinicaltrials.gov/ct2/show/NCT04114760
- Open Access
- 5 July 2021
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 23 (7) , e28361
Developing a Time-Adaptive Prediction Model for Out-of-Hospital Cardiac Arrest: Nationwide Cohort Study in Korea
Background: Out-of-hospital cardiac arrest (OHCA) is a serious public health issue, and predicting the prognosis of OHCA patients can assist clinicians in making decisions about the treatment of patients, use of hospital resources, or termination of resuscitation. Objective: This study aimed to develop a time-adaptive conditional prediction model (TACOM) to predict clinical outcomes every minute. Methods: We performed a retrospective observational study using data from the Korea OHCA Registry in South Korea. In this study, we excluded patients with trauma, those who experienced return of spontaneous circulation before arriving in the emergency department (ED), and those who did not receive cardiopulmonary resuscitation (CPR) in the ED. We selected patients who received CPR in the ED. To develop the time-adaptive prediction model, we organized the training data set as ongoing CPR patients by the minute. A total of 49,669 patients were divided into 39,602 subjects for training and 10,067 subjects for validation. We compared random forest, LightGBM, and artificial neural networks as the prediction model methods. Model performance was quantified using the prediction probability of the model, area under the receiver operating characteristic curve (AUROC), and area under the precision recall curve. Results: Among the three algorithms, LightGBM showed the best performance. From 0 to 30 min, the AUROC of the TACOM for predicting good neurological outcomes ranged from 0.910 (95% CI 0.910-0.911) to 0.869 (95% CI 0.865-0.871), whereas that for survival to hospital discharge ranged from 0.800 (95% CI 0.797-0.800) to 0.734 (95% CI 0.736-0.740). The prediction probability of the TACOM showed similar flow with cohort data based on a comparison with the conventional model’s prediction probability. Conclusions: The TACOM predicted the clinical outcome of OHCA patients per minute. This model for predicting patient outcomes by the minute can assist clinicians in making rational decisions for OHCA patients.
- 5 July 2021
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 23 (7) , e28361
Open AccessDeveloping a Time-Adaptive Prediction Model for Out-of-Hospital Cardiac Arrest: Nationwide Cohort Study in Korea
Background: Out-of-hospital cardiac arrest (OHCA) is a serious public health issue, and predicting the prognosis of OHCA patients can assist clinicians in making decisions about the treatment of patients, use of hospital resources, or termination of resuscitation. Objective: This study aimed to develop a time-adaptive conditional prediction model (TACOM) to predict clinical outcomes every minute. Methods: We performed a retrospective observational study using data from the Korea OHCA Registry in South Korea. In this study, we excluded patients with trauma, those who experienced return of spontaneous circulation before arriving in the emergency department (ED), and those who did not receive cardiopulmonary resuscitation (CPR) in the ED. We selected patients who received CPR in the ED. To develop the time-adaptive prediction model, we organized the training data set as ongoing CPR patients by the minute. A total of 49,669 patients were divided into 39,602 subjects for training and 10,067 subjects for validation. We compared random forest, LightGBM, and artificial neural networks as the prediction model methods. Model performance was quantified using the prediction probability of the model, area under the receiver operating characteristic curve (AUROC), and area under the precision recall curve. Results: Among the three algorithms, LightGBM showed the best performance. From 0 to 30 min, the AUROC of the TACOM for predicting good neurological outcomes ranged from 0.910 (95% CI 0.910-0.911) to 0.869 (95% CI 0.865-0.871), whereas that for survival to hospital discharge ranged from 0.800 (95% CI 0.797-0.800) to 0.734 (95% CI 0.736-0.740). The prediction probability of the TACOM showed similar flow with cohort data based on a comparison with the conventional model’s prediction probability. Conclusions: The TACOM predicted the clinical outcome of OHCA patients per minute. This model for predicting patient outcomes by the minute can assist clinicians in making rational decisions for OHCA patients.
- Open Access
- 1 April 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (4) , e24142
Twelve-Lead Electrocardiogram Acquisition With a Patchy-Type Wireless Device in Ambulance Transport: Simulation-Based Randomized Controlled Trial
Background: Cardiovascular disease is the leading cause of death worldwide. Early recognition, diagnosis, and reperfusion are the key elements of treatment for ST-segment elevation myocardial infarction. The absence of a prehospital 12-lead electrocardiogram (P12ECG) can cause definitive treatment delay and repeated transfer. Although guidelines highly recommend the measurement and transmission of P12ECG data, P12ECG use has not been widely established. Objective: The aim of this study was to verify the time-efficiency and feasibility of the use of a patchy-type 12-lead ECG measuring and transmitting device (P-ECG) by an emergency medical technician (EMT) in an ambulance during patient transport. Methods: This was a simulation-based prospective randomized crossover-controlled study that included EMTs. The participants were randomly assigned to one of two groups. Group A began the experiment with a conventional 12-lead ECG (C-ECG) device and then switched to the intervention device (P-ECG), whereas group B began the experiment with the P-ECG and then switched to the C-ECG. All simulations were performed inside an ambulance driving at 30 km/h. The time interval was measured from the beginning of ECG application to completion of sending the results. After the simulation, participants were administered the System Usability Scale questionnaire about usability of the P-ECG. Results: A total of 18 EMTs were recruited for this study with a median age of 35 years. The overall interval time for the C-ECG was 254 seconds (IQR 247-270), whereas the overall interval time for the P-ECG was 130 seconds (IQR 112-150), with a significant difference (P<.001). Significant differences between the C-ECG and P-ECG were identified at all time intervals, in which the P-ECG device was significantly faster in all intervals, except for the preparation interval in which the C-ECG was faster (P=.03). Conclusions: Performance of 12-lead ECG examination and transmission of the results using P-ECG are faster than those of C-ECG during ambulance transport. With the additional time afforded, EMTs can provide more care to patients and transport patients more rapidly, which may help reduce the symptoms-to-balloon time for patients with acute coronary syndrome. Trial Registration: ClinicalTrials.gov NCT04114760; https://www.clinicaltrials.gov/ct2/show/NCT04114760
- 1 April 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (4) , e24142
Open AccessTwelve-Lead Electrocardiogram Acquisition With a Patchy-Type Wireless Device in Ambulance Transport: Simulation-Based Randomized Controlled Trial
Background: Cardiovascular disease is the leading cause of death worldwide. Early recognition, diagnosis, and reperfusion are the key elements of treatment for ST-segment elevation myocardial infarction. The absence of a prehospital 12-lead electrocardiogram (P12ECG) can cause definitive treatment delay and repeated transfer. Although guidelines highly recommend the measurement and transmission of P12ECG data, P12ECG use has not been widely established. Objective: The aim of this study was to verify the time-efficiency and feasibility of the use of a patchy-type 12-lead ECG measuring and transmitting device (P-ECG) by an emergency medical technician (EMT) in an ambulance during patient transport. Methods: This was a simulation-based prospective randomized crossover-controlled study that included EMTs. The participants were randomly assigned to one of two groups. Group A began the experiment with a conventional 12-lead ECG (C-ECG) device and then switched to the intervention device (P-ECG), whereas group B began the experiment with the P-ECG and then switched to the C-ECG. All simulations were performed inside an ambulance driving at 30 km/h. The time interval was measured from the beginning of ECG application to completion of sending the results. After the simulation, participants were administered the System Usability Scale questionnaire about usability of the P-ECG. Results: A total of 18 EMTs were recruited for this study with a median age of 35 years. The overall interval time for the C-ECG was 254 seconds (IQR 247-270), whereas the overall interval time for the P-ECG was 130 seconds (IQR 112-150), with a significant difference (P<.001). Significant differences between the C-ECG and P-ECG were identified at all time intervals, in which the P-ECG device was significantly faster in all intervals, except for the preparation interval in which the C-ECG was faster (P=.03). Conclusions: Performance of 12-lead ECG examination and transmission of the results using P-ECG are faster than those of C-ECG during ambulance transport. With the additional time afforded, EMTs can provide more care to patients and transport patients more rapidly, which may help reduce the symptoms-to-balloon time for patients with acute coronary syndrome. Trial Registration: ClinicalTrials.gov NCT04114760; https://www.clinicaltrials.gov/ct2/show/NCT04114760
- Open Access
- 2 March 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Developing a Time-Adaptive Prediction Model for Out-of-Hospital Cardiac Arrest: Nationwide Cohort Study in Korea (Preprint)
BACKGROUND Out-of-hospital cardiac arrest (OHCA) is a serious public health issue, and predicting the prognosis of OHCA patients can assist clinicians in making decisions about the treatment of patients, use of hospital resources, or termination of resuscitation. OBJECTIVE This study aimed to develop a time-adaptive conditional prediction model (TACOM) to predict clinical outcomes every minute. METHODS We performed a retrospective observational study using data from the Korea OHCA Registry in South Korea. In this study, we excluded patients with trauma, those who experienced return of spontaneous circulation before arriving in the emergency department (ED), and those who did not receive cardiopulmonary resuscitation (CPR) in the ED. We selected patients who received CPR in the ED. To develop the time-adaptive prediction model, we organized the training data set as ongoing CPR patients by the minute. A total of 49,669 patients were divided into 39,602 subjects for training and 10,067 subjects for validation. We compared random forest, LightGBM, and artificial neural networks as the prediction model methods. Model performance was quantified using the prediction probability of the model, area under the receiver operating characteristic curve (AUROC), and area under the precision recall curve. RESULTS Among the three algorithms, LightGBM showed the best performance. From 0 to 30 min, the AUROC of the TACOM for predicting good neurological outcomes ranged from 0.910 (95% CI 0.910-0.911) to 0.869 (95% CI 0.865-0.871), whereas that for survival to hospital discharge ranged from 0.800 (95% CI 0.797-0.800) to 0.734 (95% CI 0.736-0.740). The prediction probability of the TACOM showed similar flow with cohort data based on a comparison with the conventional model’s prediction probability. CONCLUSIONS The TACOM predicted the clinical outcome of OHCA patients per minute. This model for predicting patient outcomes by the minute can assist clinicians in making rational decisions for OHCA patients.
- 2 March 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessDeveloping a Time-Adaptive Prediction Model for Out-of-Hospital Cardiac Arrest: Nationwide Cohort Study in Korea (Preprint)
BACKGROUND Out-of-hospital cardiac arrest (OHCA) is a serious public health issue, and predicting the prognosis of OHCA patients can assist clinicians in making decisions about the treatment of patients, use of hospital resources, or termination of resuscitation. OBJECTIVE This study aimed to develop a time-adaptive conditional prediction model (TACOM) to predict clinical outcomes every minute. METHODS We performed a retrospective observational study using data from the Korea OHCA Registry in South Korea. In this study, we excluded patients with trauma, those who experienced return of spontaneous circulation before arriving in the emergency department (ED), and those who did not receive cardiopulmonary resuscitation (CPR) in the ED. We selected patients who received CPR in the ED. To develop the time-adaptive prediction model, we organized the training data set as ongoing CPR patients by the minute. A total of 49,669 patients were divided into 39,602 subjects for training and 10,067 subjects for validation. We compared random forest, LightGBM, and artificial neural networks as the prediction model methods. Model performance was quantified using the prediction probability of the model, area under the receiver operating characteristic curve (AUROC), and area under the precision recall curve. RESULTS Among the three algorithms, LightGBM showed the best performance. From 0 to 30 min, the AUROC of the TACOM for predicting good neurological outcomes ranged from 0.910 (95% CI 0.910-0.911) to 0.869 (95% CI 0.865-0.871), whereas that for survival to hospital discharge ranged from 0.800 (95% CI 0.797-0.800) to 0.734 (95% CI 0.736-0.740). The prediction probability of the TACOM showed similar flow with cohort data based on a comparison with the conventional model’s prediction probability. CONCLUSIONS The TACOM predicted the clinical outcome of OHCA patients per minute. This model for predicting patient outcomes by the minute can assist clinicians in making rational decisions for OHCA patients.
- Open Access
- 5 September 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Twelve-Lead Electrocardiogram Acquisition With a Patchy-Type Wireless Device in Ambulance Transport: Simulation-Based Randomized Controlled Trial (Preprint)
BACKGROUND Cardiovascular disease is the leading cause of death worldwide. Early recognition, diagnosis, and reperfusion are the key elements of treatment for ST-segment elevation myocardial infarction. The absence of a prehospital 12-lead electrocardiogram (P12ECG) can cause definitive treatment delay and repeated transfer. Although guidelines highly recommend the measurement and transmission of P12ECG data, P12ECG use has not been widely established. OBJECTIVE The aim of this study was to verify the time-efficiency and feasibility of the use of a patchy-type 12-lead ECG measuring and transmitting device (P-ECG) by an emergency medical technician (EMT) in an ambulance during patient transport. METHODS This was a simulation-based prospective randomized crossover-controlled study that included EMTs. The participants were randomly assigned to one of two groups. Group A began the experiment with a conventional 12-lead ECG (C-ECG) device and then switched to the intervention device (P-ECG), whereas group B began the experiment with the P-ECG and then switched to the C-ECG. All simulations were performed inside an ambulance driving at 30 km/h. The time interval was measured from the beginning of ECG application to completion of sending the results. After the simulation, participants were administered the System Usability Scale questionnaire about usability of the P-ECG. RESULTS A total of 18 EMTs were recruited for this study with a median age of 35 years. The overall interval time for the C-ECG was 254 seconds (IQR 247-270), whereas the overall interval time for the P-ECG was 130 seconds (IQR 112-150), with a significant difference (P<.001). Significant differences between the C-ECG and P-ECG were identified at all time intervals, in which the P-ECG device was significantly faster in all intervals, except for the preparation interval in which the C-ECG was faster (P=.03). CONCLUSIONS Performance of 12-lead ECG examination and transmission of the results using P-ECG are faster than those of C-ECG during ambulance transport. With the additional time afforded, EMTs can provide more care to patients and transport patients more rapidly, which may help reduce the symptoms-to-balloon time for patients with acute coronary syndrome. CLINICALTRIAL ClinicalTrials.gov NCT04114760; https://www.clinicaltrials.gov/ct2/show/NCT04114760
- 5 September 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessTwelve-Lead Electrocardiogram Acquisition With a Patchy-Type Wireless Device in Ambulance Transport: Simulation-Based Randomized Controlled Trial (Preprint)
BACKGROUND Cardiovascular disease is the leading cause of death worldwide. Early recognition, diagnosis, and reperfusion are the key elements of treatment for ST-segment elevation myocardial infarction. The absence of a prehospital 12-lead electrocardiogram (P12ECG) can cause definitive treatment delay and repeated transfer. Although guidelines highly recommend the measurement and transmission of P12ECG data, P12ECG use has not been widely established. OBJECTIVE The aim of this study was to verify the time-efficiency and feasibility of the use of a patchy-type 12-lead ECG measuring and transmitting device (P-ECG) by an emergency medical technician (EMT) in an ambulance during patient transport. METHODS This was a simulation-based prospective randomized crossover-controlled study that included EMTs. The participants were randomly assigned to one of two groups. Group A began the experiment with a conventional 12-lead ECG (C-ECG) device and then switched to the intervention device (P-ECG), whereas group B began the experiment with the P-ECG and then switched to the C-ECG. All simulations were performed inside an ambulance driving at 30 km/h. The time interval was measured from the beginning of ECG application to completion of sending the results. After the simulation, participants were administered the System Usability Scale questionnaire about usability of the P-ECG. RESULTS A total of 18 EMTs were recruited for this study with a median age of 35 years. The overall interval time for the C-ECG was 254 seconds (IQR 247-270), whereas the overall interval time for the P-ECG was 130 seconds (IQR 112-150), with a significant difference (P<.001). Significant differences between the C-ECG and P-ECG were identified at all time intervals, in which the P-ECG device was significantly faster in all intervals, except for the preparation interval in which the C-ECG was faster (P=.03). CONCLUSIONS Performance of 12-lead ECG examination and transmission of the results using P-ECG are faster than those of C-ECG during ambulance transport. With the additional time afforded, EMTs can provide more care to patients and transport patients more rapidly, which may help reduce the symptoms-to-balloon time for patients with acute coronary syndrome. CLINICALTRIAL ClinicalTrials.gov NCT04114760; https://www.clinicaltrials.gov/ct2/show/NCT04114760
- Open Access
- 1 January 2020
- Published by XMLink in Journal of Korean Medical Science
- Vol. 35 (19) , e131
Vasospasm-Related Sudden Cardiac Death Has Outcomes Comparable with Coronary Stenosis in Out-of-Hospital Cardiac Arrest
Lee DH, et al. J Korean Med Sci. 2020 Mar;35(19):e131. https://doi.org/10.3346/jkms.2020.35.e131
- 1 January 2020
- Published by XMLink in Journal of Korean Medical Science
- Vol. 35 (19) , e131
Open AccessVasospasm-Related Sudden Cardiac Death Has Outcomes Comparable with Coronary Stenosis in Out-of-Hospital Cardiac Arrest
Lee DH, et al. J Korean Med Sci. 2020 Mar;35(19):e131. https://doi.org/10.3346/jkms.2020.35.e131
- Open Access
- 1 January 2020
- Published by XMLink in Journal of Korean Medical Science
- Vol. 35 (9) , e60
Epidemiology and Outcome of Powered Mobility Device-Related Injuries in Korea
Shin Y, et al. J Korean Med Sci. 2020 Jan;35(9):e60. https://doi.org/10.3346/jkms.2020.35.e60
- 1 January 2020
- Published by XMLink in Journal of Korean Medical Science
- Vol. 35 (9) , e60
Open AccessEpidemiology and Outcome of Powered Mobility Device-Related Injuries in Korea
Shin Y, et al. J Korean Med Sci. 2020 Jan;35(9):e60. https://doi.org/10.3346/jkms.2020.35.e60
- 7 March 2019
- Published by Wiley in Pharmacoepidemiology and Drug Safety
- Vol. 28 (4) , 536-543
Availability of drug at convenient stores is not associated with an increased incidence of their poisoning
Purpose: In late 2012, South Korea revised the Pharmaceutical Affairs Act to make selected medications including acetaminophen, ibuprofen, and cold medications available in nonpharmacy outlets, including the 24‐hour convenient stores (CVS). The objective of this study was to identify whether the characteristics and trend of self‐poisonings associated with these medications were altered after the legislative change.Methods: A retrospective study was performed using national data from the Emergency Department (ED)‐based Injury In‐depth Surveillance database. The patients diagnosed with poisoning were sorted from 2011 to 2016 and included in the study. As the Act was implemented from 2013, the demographic characteristics and clinical outcomes were compared before and after January 2013. A piecewise regression analysis was performed to determine the association between the monthly use of acetaminophen, medication for cold, and nonsteroidal anti‐inflammatory drugs (NSAIDs) and the incidence of total poisonings before and after the January 2013.Results: Among 1 536 277 patients included in the database, 17 523 patients diagnosed with poisoning were enrolled. After the legislative change, the etiology of poisoning did not change, although the frequency of hospitalization from ED was significantly increased. The monthly trend for poisoning due to acetaminophen, cold medications, and NSAIDs showed no significant slope change between before and after the legislative change. The proportional use of acetaminophen and cold medications was significantly decreased, while that of NSAIDs was unchanged before and after the legislative change.Conclusions: The change in the Pharmaceutical Affairs Act was not associated with any change in the monthly frequency of medication‐related poisoning.
- 7 March 2019
- Published by Wiley in Pharmacoepidemiology and Drug Safety
- Vol. 28 (4) , 536-543
Availability of drug at convenient stores is not associated with an increased incidence of their poisoning
Purpose: In late 2012, South Korea revised the Pharmaceutical Affairs Act to make selected medications including acetaminophen, ibuprofen, and cold medications available in nonpharmacy outlets, including the 24‐hour convenient stores (CVS). The objective of this study was to identify whether the characteristics and trend of self‐poisonings associated with these medications were altered after the legislative change.Methods: A retrospective study was performed using national data from the Emergency Department (ED)‐based Injury In‐depth Surveillance database. The patients diagnosed with poisoning were sorted from 2011 to 2016 and included in the study. As the Act was implemented from 2013, the demographic characteristics and clinical outcomes were compared before and after January 2013. A piecewise regression analysis was performed to determine the association between the monthly use of acetaminophen, medication for cold, and nonsteroidal anti‐inflammatory drugs (NSAIDs) and the incidence of total poisonings before and after the January 2013.Results: Among 1 536 277 patients included in the database, 17 523 patients diagnosed with poisoning were enrolled. After the legislative change, the etiology of poisoning did not change, although the frequency of hospitalization from ED was significantly increased. The monthly trend for poisoning due to acetaminophen, cold medications, and NSAIDs showed no significant slope change between before and after the legislative change. The proportional use of acetaminophen and cold medications was significantly decreased, while that of NSAIDs was unchanged before and after the legislative change.Conclusions: The change in the Pharmaceutical Affairs Act was not associated with any change in the monthly frequency of medication‐related poisoning.
- Open Access
- 1 January 2019
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 25 (4) , 274-282
Effect of Watch-Type Haptic Metronome on the Quality of Cardiopulmonary Resuscitation: A Simulation Study
The aim of this study was to test the applicability of haptic feedback using a smartwatch to the delivery of cardiac compression (CC) by professional healthcare providers. A prospective, randomized, controlled, case-crossover, standardized simulation study of 20 medical professionals was conducted. The participants were randomly assigned into haptic-first and non-haptic-first groups. The primary outcome was an adequate rate of 100-120/min of CC. The secondary outcome was a comparison of CC rate and adequate duration between the good and bad performance groups. The mean interval between CCs and the number of haptic and non-haptic feedback-assisted CCs with an adequate duration were insignificant. In the subgroup analysis, both the good and bad performance groups showed a significant difference in the mean CC interval between the haptic and non-haptic feedback-assisted CC groups-good: haptic feedback-assisted (0.57-0.06) vs. non-haptic feedback-assisted (0.54-0.03), p < 0.001; bad: haptic feedback-assisted (0.57-0.07) vs. non-haptic feedback-assisted (0.58-0.18), p = 0.005-and the adequate chest compression number showed significant differences- good: haptic feedback-assisted (1,597/75.1%) vs. non-haptic feedback-assisted (1,951/92.2%), p < 0.001; bad: haptic feedbackassisted (1,341/63.5%) vs. non-haptic feedback-assisted (523/25.4%), p < 0.001. A smartwatch cardiopulmonary resuscitation feedback system could not improve rescuers' CC rate. According to our subgroup analysis, participants might be aided by the device to increase the percentage of adequate compressions after one minute.
- 1 January 2019
- Published by The Korean Society of Medical Informatics in Healthcare Informatics Research
- Vol. 25 (4) , 274-282
Open AccessEffect of Watch-Type Haptic Metronome on the Quality of Cardiopulmonary Resuscitation: A Simulation Study
The aim of this study was to test the applicability of haptic feedback using a smartwatch to the delivery of cardiac compression (CC) by professional healthcare providers. A prospective, randomized, controlled, case-crossover, standardized simulation study of 20 medical professionals was conducted. The participants were randomly assigned into haptic-first and non-haptic-first groups. The primary outcome was an adequate rate of 100-120/min of CC. The secondary outcome was a comparison of CC rate and adequate duration between the good and bad performance groups. The mean interval between CCs and the number of haptic and non-haptic feedback-assisted CCs with an adequate duration were insignificant. In the subgroup analysis, both the good and bad performance groups showed a significant difference in the mean CC interval between the haptic and non-haptic feedback-assisted CC groups-good: haptic feedback-assisted (0.57-0.06) vs. non-haptic feedback-assisted (0.54-0.03), p < 0.001; bad: haptic feedback-assisted (0.57-0.07) vs. non-haptic feedback-assisted (0.58-0.18), p = 0.005-and the adequate chest compression number showed significant differences- good: haptic feedback-assisted (1,597/75.1%) vs. non-haptic feedback-assisted (1,951/92.2%), p < 0.001; bad: haptic feedbackassisted (1,341/63.5%) vs. non-haptic feedback-assisted (523/25.4%), p < 0.001. A smartwatch cardiopulmonary resuscitation feedback system could not improve rescuers' CC rate. According to our subgroup analysis, participants might be aided by the device to increase the percentage of adequate compressions after one minute.