Darryl J. McAndrew
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Darryl J. McAndrew has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Paul James Stapley
Neural Control of Movement Laboratory, School of Medical, Indigenous and Health Sciences, Faculty of Science, Medicine and Health, University of Wollongong, Wollongong, NSW, Australia
4 shared publications - Prashan Premaratne
University of Wollongong
4 shared publications J. M. M. Brown
School of Health Science, University of Wollongong, Wollongong, NSW, 2522, Australia
3 shared publications- James Wickham
School of Biomedical Sciences, Charles Sturt University, Orange, New South Wales, Australia
3 shared publications Peter J. Vial
School of Electrical, Computer, and Telecommunication Engineering, Faculty of Engineering and Information Scinces, University of Wollongong, North Avenue, Wollongong, NSW, Australia
3 shared publicationsQasim Al-Shebani
School of Electrical, Computer, and Telecommunication Engineering, Faculty of Engineering and Information Scinces, University of Wollongong, North Avenue, Wollongong, NSW, Australia
3 shared publications
Latest Publications
- 1 August 2020
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 342, 108813
Randomising stimulus intensity improves the variability and reliability of the assessment of corticospinal excitability
- 1 August 2020
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 342, 108813
Randomising stimulus intensity improves the variability and reliability of the assessment of corticospinal excitability
- Open Access
- 16 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Global Corticospinal Excitability as Assessed in A Non-Exercised Upper Limb Muscle Compared Between Concentric and Eccentric Modes of Leg Cycling
This study investigated the effects of eccentric (ECC) and concentric (CON) semi-recumbent leg cycling on global corticospinal excitability (CSE), assessed through the activity of a non-exercised hand muscle. Thirteen healthy male adults completed two 30-min bouts of moderate intensity ECC and CON recumbent cycling on separate days. Power output (POutput), heart rate (HR) and cadence were monitored during cycling. Global CSE was assessed using transcranial magnetic stimulation to elicit motor-evoked potentials (MEP) in the right first dorsal interosseous muscle before (‘Pre’), interleaved (at 10 and 20 mins, t10 and t20, respectively), immediately after (post, P0), and 30-min post exercise (P30). Participants briefly stopped pedalling (no more than 60 s) while stimulation was applied at the t10 and t20 time-points of cycling. Mean POutput, and rate of perceived exertion (RPE) did not differ between ECC and CON cycling and HR was significantly lower during ECC cycling (P = 0.01). Group mean MEP amplitudes were not significantly different between ECC and CON cycling at P0, t10, t20, and P30 and CON (at P > 0.05). Individual participant ratios of POutput and MEP amplitude showed large variability across the two modes of cycling, as did changes in slope of stimulus-response curves. These results suggest that compared to ‘Pre’ values, group mean CSE is not significantly affected by low-moderate intensity leg cycling in both modes. However, POutput and CSE show wide inter-participant variability which has implications for individual neural responses to CON and ECC cycling and rates of adaptation to a novel (ECC) mode. The study of CSE should therefore be analysed for each participant individually in relation to relevant physiological variables and account for familiarisation to semi-recumbent ECC leg cycling.
- 16 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Open AccessGlobal Corticospinal Excitability as Assessed in A Non-Exercised Upper Limb Muscle Compared Between Concentric and Eccentric Modes of Leg Cycling
This study investigated the effects of eccentric (ECC) and concentric (CON) semi-recumbent leg cycling on global corticospinal excitability (CSE), assessed through the activity of a non-exercised hand muscle. Thirteen healthy male adults completed two 30-min bouts of moderate intensity ECC and CON recumbent cycling on separate days. Power output (POutput), heart rate (HR) and cadence were monitored during cycling. Global CSE was assessed using transcranial magnetic stimulation to elicit motor-evoked potentials (MEP) in the right first dorsal interosseous muscle before (‘Pre’), interleaved (at 10 and 20 mins, t10 and t20, respectively), immediately after (post, P0), and 30-min post exercise (P30). Participants briefly stopped pedalling (no more than 60 s) while stimulation was applied at the t10 and t20 time-points of cycling. Mean POutput, and rate of perceived exertion (RPE) did not differ between ECC and CON cycling and HR was significantly lower during ECC cycling (P = 0.01). Group mean MEP amplitudes were not significantly different between ECC and CON cycling at P0, t10, t20, and P30 and CON (at P > 0.05). Individual participant ratios of POutput and MEP amplitude showed large variability across the two modes of cycling, as did changes in slope of stimulus-response curves. These results suggest that compared to ‘Pre’ values, group mean CSE is not significantly affected by low-moderate intensity leg cycling in both modes. However, POutput and CSE show wide inter-participant variability which has implications for individual neural responses to CON and ECC cycling and rates of adaptation to a novel (ECC) mode. The study of CSE should therefore be analysed for each participant individually in relation to relevant physiological variables and account for familiarisation to semi-recumbent ECC leg cycling.
- 4 May 2019
- Published by Elsevier in Signal Processing: Image Communication
- Vol. 76, 135-150
The development of a clinically tested visually lossless Image compression system for capsule endoscopy
- 4 May 2019
- Published by Elsevier in Signal Processing: Image Communication
- Vol. 76, 135-150
The development of a clinically tested visually lossless Image compression system for capsule endoscopy
- 1 March 2019
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 94, 18-27
A frame reduction system based on a color structural similarity (CSS) method and Bayer images analysis for capsule endoscopy
- 1 March 2019
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 94, 18-27
A frame reduction system based on a color structural similarity (CSS) method and Bayer images analysis for capsule endoscopy
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Feasibility of an Internal Mechanism for Capsule Endoscopy Locomotion and Retention-Release
The passive movement of capsule endoscopy has geared research to investigate the possibility of developing a locomotion mechanism to allow the control of the capsule movement. The size and the power capacity of capsule endoscopy have been the main bottlenecks to achieve an efficient locomotion design. Running a locomotion device for a long time it seems to be impossible without the utilization of an external magnetic field that has been found to be unsafe for human risks. A short utilization of a locomotion mechanism, which is controlled from outside the capsule, could solve the problems of size and power capacity limitations. The short utilization of the simplified design could solve a major risk of capsule endoscopy which is capsule retention. This paper is set out to investigate the feasibility of developing an internal capsule retention release mechanism to solve the problem of capsule endoscopy retention. This includes the design and configuration of new capsule model to mount the proposed locomotion system. Two types of motors were tested in this paper; these are a two-phase stepper motor and a coin-type vibration motor. The design of the printed circuit board (PCB) of the nRF51×822 was reconfigured to fit within the small dimensions of the new model. The operation performance of both motors using a limited power source has been recorded which show that the proposed design is able to work efficiently for a limited time. However, a number of steps need to be undertaken to realize the feasibility of the new design for practice which includes testing in an animal or a fabricated model that allow for peristaltic movement similar to the human GI tract movement.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Feasibility of an Internal Mechanism for Capsule Endoscopy Locomotion and Retention-Release
The passive movement of capsule endoscopy has geared research to investigate the possibility of developing a locomotion mechanism to allow the control of the capsule movement. The size and the power capacity of capsule endoscopy have been the main bottlenecks to achieve an efficient locomotion design. Running a locomotion device for a long time it seems to be impossible without the utilization of an external magnetic field that has been found to be unsafe for human risks. A short utilization of a locomotion mechanism, which is controlled from outside the capsule, could solve the problems of size and power capacity limitations. The short utilization of the simplified design could solve a major risk of capsule endoscopy which is capsule retention. This paper is set out to investigate the feasibility of developing an internal capsule retention release mechanism to solve the problem of capsule endoscopy retention. This includes the design and configuration of new capsule model to mount the proposed locomotion system. Two types of motors were tested in this paper; these are a two-phase stepper motor and a coin-type vibration motor. The design of the printed circuit board (PCB) of the nRF51×822 was reconfigured to fit within the small dimensions of the new model. The operation performance of both motors using a limited power source has been recorded which show that the proposed design is able to work efficiently for a limited time. However, a number of steps need to be undertaken to realize the feasibility of the new design for practice which includes testing in an animal or a fabricated model that allow for peristaltic movement similar to the human GI tract movement.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Co-Simulation Method for Hardware/Software Evaluation Using Xilinx System Generator: A Case Study on Image Compression Algorithms for Capsule Endoscopy
Testing using the co-simulation method of an algorithm is important to visualize the hardware performance of the algorithm. This study aims to introduce a method for comparing the hardware performance of two different algorithms with a focus on the existing compression system for capsule endoscopy as a case study. The size limitation of capsule endoscopy which constrains the power source and the complexity of the hardware utilization are the main reasons for selecting the capsule endoscopy compression system for this case study. Undertaking a comparison between different algorithms from the existing image compression algorithms in capsule endoscopy can highlight the main testing steps of the co-simulation testing method. To allow a fair comparison, the hardware co-simulation is implemented using the same FPGA device for the methods compared in this study and the results acquired are discussed.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Co-Simulation Method for Hardware/Software Evaluation Using Xilinx System Generator: A Case Study on Image Compression Algorithms for Capsule Endoscopy
Testing using the co-simulation method of an algorithm is important to visualize the hardware performance of the algorithm. This study aims to introduce a method for comparing the hardware performance of two different algorithms with a focus on the existing compression system for capsule endoscopy as a case study. The size limitation of capsule endoscopy which constrains the power source and the complexity of the hardware utilization are the main reasons for selecting the capsule endoscopy compression system for this case study. Undertaking a comparison between different algorithms from the existing image compression algorithms in capsule endoscopy can highlight the main testing steps of the co-simulation testing method. To allow a fair comparison, the hardware co-simulation is implemented using the same FPGA device for the methods compared in this study and the results acquired are discussed.
- Open Access
- 13 October 2017
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 2 (4) , 36
The “Journal of Functional Morphology and Kinesiology” Journal Club Series: Highlights on Recent Papers in Strength and Conditioning
We are pleased to introduce the sixth Journal Club. This edition is focused on several relevant studies published in the last years in the field of Strength and Conditioning, chosen by our Editorial Board members and their colleagues. We hope to stimulate your curiosity in this field and to share with you the passion for sport and exercise seen from a scientific point of view. The Editorial Board members wish you an inspiring read.
- 13 October 2017
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 2 (4) , 36
Open AccessThe “Journal of Functional Morphology and Kinesiology” Journal Club Series: Highlights on Recent Papers in Strength and Conditioning
We are pleased to introduce the sixth Journal Club. This edition is focused on several relevant studies published in the last years in the field of Strength and Conditioning, chosen by our Editorial Board members and their colleagues. We hope to stimulate your curiosity in this field and to share with you the passion for sport and exercise seen from a scientific point of view. The Editorial Board members wish you an inspiring read.
- 1 April 2016
- Vol. 45 (4) , 212-5
The validity of visual acuity assessment using mobile technology devices in the primary care setting.
The assessment of visual acuity is indicated in a number of clinical circumstances. It is commonly conducted through the use of a Snellen wall chart. Mobile technology developments and adoption rates by clinicians may potentially provide more convenient methods of assessing visual acuity. Limited data exist on the validity of these devices and applications. The objective of this study was to evaluate the assessment of distance visual acuity using mobile technology devices against the commonly used 3-metre Snellen chart in a primary care setting. A prospective quantitative comparative study was conducted at a regional medical practice. The visual acuity of 60 participants was assessed on a Snellen wall chart and two mobile technology devices (iPhone, iPad). Visual acuity intervals were converted to logarithm of minimum angle of resolution (logMAR) scores and subjected to intraclass correlation coefficient (ICC) assessment. The results show a high level of general agreement between testing modality (ICC 0.917 with a 95% confidence interval of 0.887-0.940). The high level of agreement of visual acuity results between the Snellen wall chart and both mobile technology devices suggests that clinicians can use this technology with confidence in the primary care setting.
- 1 April 2016
- Vol. 45 (4) , 212-5
The validity of visual acuity assessment using mobile technology devices in the primary care setting.
The assessment of visual acuity is indicated in a number of clinical circumstances. It is commonly conducted through the use of a Snellen wall chart. Mobile technology developments and adoption rates by clinicians may potentially provide more convenient methods of assessing visual acuity. Limited data exist on the validity of these devices and applications. The objective of this study was to evaluate the assessment of distance visual acuity using mobile technology devices against the commonly used 3-metre Snellen chart in a primary care setting. A prospective quantitative comparative study was conducted at a regional medical practice. The visual acuity of 60 participants was assessed on a Snellen wall chart and two mobile technology devices (iPhone, iPad). Visual acuity intervals were converted to logarithm of minimum angle of resolution (logMAR) scores and subjected to intraclass correlation coefficient (ICC) assessment. The results show a high level of general agreement between testing modality (ICC 0.917 with a 95% confidence interval of 0.887-0.940). The high level of agreement of visual acuity results between the Snellen wall chart and both mobile technology devices suggests that clinicians can use this technology with confidence in the primary care setting.
- 2 February 2016
- Published by Springer Nature in Experimental Brain Research
- Vol. 234 (6) , 1599-1609
Age-related effects of increasing postural challenge on eye movement onset latencies to visual targets
When a single light cue is given in the visual field, our eyes orient towards it with an average latency of 200 ms. If a second cue is presented at or around the time of the response to the first, a secondary eye movement occurs that represents a reorientation to the new target. While studies have shown that eye movement latencies to ‘single-step’ targets may or may not be lengthened with age, secondary eye movements (during ‘double-step’ displacements) are significantly delayed with increasing age. The aim of this study was to investigate whether the postural challenge posed simply by standing (as opposed to sitting) results in significantly longer eye movement latencies in older adults compared to the young. Ten young (65 years) participated in the study. They were required to fixate upon a central target and move their eyes in response to 2 types of stimuli: (1) a single-step perturbation of target position either 15° to the right or left and (2) a double-step target displacement incorporating an initial target jump to the right or left by 15°, followed after 200 ms, by a shift of target position to the opposite side (e.g. +15° then −15°). All target displacement conditions were executed in sit and stand positions with the participant at the same distance from the targets. Eye movements were recorded using electro-oculography. Older adults did not show significantly longer eye movement latencies than the younger adults for single-step target displacements, and postural configuration (stand compared to sit) had no effect upon latencies for either group. We categorised double-step trials into those during which the second light changed after or before the onset of the eye shift to the first light. For the former category, young participants showed faster secondary eye shifts to the second light in the standing position, while the older adults did not. For the latter category of double-step trial, young participants showed no significant difference between sit and stand secondary eye movement latencies, but older adults were significantly longer standing compared to sitting. The older adults were significantly longer than the younger adults across both postural conditions, regardless of when the second light change occurred during the eye shift to the first light. We suggest that older adults require greater time and perhaps attentional processes to execute eye movements to unexpected changes in target position when faced with the need to maintain standing balance.
- 2 February 2016
- Published by Springer Nature in Experimental Brain Research
- Vol. 234 (6) , 1599-1609
Age-related effects of increasing postural challenge on eye movement onset latencies to visual targets
When a single light cue is given in the visual field, our eyes orient towards it with an average latency of 200 ms. If a second cue is presented at or around the time of the response to the first, a secondary eye movement occurs that represents a reorientation to the new target. While studies have shown that eye movement latencies to ‘single-step’ targets may or may not be lengthened with age, secondary eye movements (during ‘double-step’ displacements) are significantly delayed with increasing age. The aim of this study was to investigate whether the postural challenge posed simply by standing (as opposed to sitting) results in significantly longer eye movement latencies in older adults compared to the young. Ten young (65 years) participated in the study. They were required to fixate upon a central target and move their eyes in response to 2 types of stimuli: (1) a single-step perturbation of target position either 15° to the right or left and (2) a double-step target displacement incorporating an initial target jump to the right or left by 15°, followed after 200 ms, by a shift of target position to the opposite side (e.g. +15° then −15°). All target displacement conditions were executed in sit and stand positions with the participant at the same distance from the targets. Eye movements were recorded using electro-oculography. Older adults did not show significantly longer eye movement latencies than the younger adults for single-step target displacements, and postural configuration (stand compared to sit) had no effect upon latencies for either group. We categorised double-step trials into those during which the second light changed after or before the onset of the eye shift to the first light. For the former category, young participants showed faster secondary eye shifts to the second light in the standing position, while the older adults did not. For the latter category of double-step trial, young participants showed no significant difference between sit and stand secondary eye movement latencies, but older adults were significantly longer standing compared to sitting. The older adults were significantly longer than the younger adults across both postural conditions, regardless of when the second light change occurred during the eye shift to the first light. We suggest that older adults require greater time and perhaps attentional processes to execute eye movements to unexpected changes in target position when faced with the need to maintain standing balance.
- 1 October 2015
- Published by Elsevier in Experimental Gerontology
- Vol. 70, 135-143
Of mice, pigs and humans: An analysis of mitochondrial phospholipids from mammals with very different maximal lifespans
- 1 October 2015
- Published by Elsevier in Experimental Gerontology
- Vol. 70, 135-143
Of mice, pigs and humans: An analysis of mitochondrial phospholipids from mammals with very different maximal lifespans