Sakari Ihantola
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sakari Ihantola has a total of 128 co-authors. Here are the top co-authors by number of shared publications:
Harri Toivonen
STUK-Radiation and Nuclear Safety Authority, Helsinki, Finland
11 shared publications- Juha Toivonen
Photonics Laboratory, Physics Unit, Faculty of Engineering and Natural Sciences, Tampere University
7 shared publications Kari Peräjärvi
STUK-Radiation and Nuclear Safety Authority, Helsinki, Finland
7 shared publicationsA. De Roeck
Departement of Physics, Universiteit Antwerpen, Prinsstraat 13, Antwerpen, 2000 Belgium
5 shared publicationsA. Weber
Sub-department of Particle Physics, University of Oxford, Keble Rd, Oxford, OX14 5PX United Kingdom
5 shared publicationsB. Coupé
BR2 reactor, SCK CEN, Boeretang 200, Mol, Belgium
5 shared publications
Latest Publications
- Open Access
- 18 December 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-8
Novel environmental monitoring detector for discriminating fallout and airborne radioactivity
Early warning networks are used for detecting abnormal radioactivity levels in the environment. State-of-the-art networks are equipped with both dose rate detectors and spectrometric stations. Current networks don’t automatically discriminate between radioactivity on the ground and in the air. A novel directional sensing gamma radiation detector utilizing a collimated phoswich scintillator was developed. The signals from the two scintillator materials are separated using a pulse shape discrimination. The separated signals are employed to determine the radioactivity concentrations on the ground and in the air assuming specific concentration distributions. Limitations related to imperfect directional sensing and dead time are discussed.
- 18 December 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-8
Open AccessNovel environmental monitoring detector for discriminating fallout and airborne radioactivity
Early warning networks are used for detecting abnormal radioactivity levels in the environment. State-of-the-art networks are equipped with both dose rate detectors and spectrometric stations. Current networks don’t automatically discriminate between radioactivity on the ground and in the air. A novel directional sensing gamma radiation detector utilizing a collimated phoswich scintillator was developed. The signals from the two scintillator materials are separated using a pulse shape discrimination. The separated signals are employed to determine the radioactivity concentrations on the ground and in the air assuming specific concentration distributions. Limitations related to imperfect directional sensing and dead time are discussed.
- Open Access
- 1 June 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 160, 109110
Method for the diagnosis of aged plastic radiation portal monitors
- 1 June 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 160, 109110
Open AccessMethod for the diagnosis of aged plastic radiation portal monitors
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (11) , P11003
Commissioning and operation of the readout system for the SoLid neutrino detector
The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order to identify these interactions. A novel detector design has been developed using 12800 5 cm cubes for high segmentation. Each cube is formed of a sandwich of two scintillators, PVT and 6LiF:ZnS(Ag), allowing the detection and identification of positrons and neutrons respectively. The active volume of the detector is an array of cubes measuring 80× 80× 250 cm (corresponding to a fiducial mass of 1.6 T), which is read out in layers using two dimensional arrays of wavelength shifting fibres and silicon photomultipliers, for a total of 3200 readout channels. Signals are recorded with 14 bit resolution, and at 40 MHz sampling frequency, for a total raw data rate of over 2 Tbit/s. In this paper, we describe a novel readout and trigger system built for the experiment, that satisfies requirements on: compactness, low power, high performance, and very low cost per channel. The system uses a combination of high price-performance FPGAs with a gigabit Ethernet based readout system, and its total power consumption is under 1 kW. The use of zero suppression techniques, combined with pulse shape discrimination trigger algorithms to detect neutrons, results in an online data reduction factor of around 10000. The neutron trigger is combined with a large per-channel history time buffer, allowing for unbiased positron detection. The system was commissioned in late 2017, with successful physics data taking established in early 2018.
- 1 November 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (11) , P11003
Open AccessCommissioning and operation of the readout system for the SoLid neutrino detector
The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order to identify these interactions. A novel detector design has been developed using 12800 5 cm cubes for high segmentation. Each cube is formed of a sandwich of two scintillators, PVT and 6LiF:ZnS(Ag), allowing the detection and identification of positrons and neutrons respectively. The active volume of the detector is an array of cubes measuring 80× 80× 250 cm (corresponding to a fiducial mass of 1.6 T), which is read out in layers using two dimensional arrays of wavelength shifting fibres and silicon photomultipliers, for a total of 3200 readout channels. Signals are recorded with 14 bit resolution, and at 40 MHz sampling frequency, for a total raw data rate of over 2 Tbit/s. In this paper, we describe a novel readout and trigger system built for the experiment, that satisfies requirements on: compactness, low power, high performance, and very low cost per channel. The system uses a combination of high price-performance FPGAs with a gigabit Ethernet based readout system, and its total power consumption is under 1 kW. The use of zero suppression techniques, combined with pulse shape discrimination trigger algorithms to detect neutrons, results in an online data reduction factor of around 10000. The neutron trigger is combined with a large per-channel history time buffer, allowing for unbiased positron detection. The system was commissioned in late 2017, with successful physics data taking established in early 2018.
- 1 February 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (02) , P02014
Development of a quality assurance process for the SoLid experiment
- 1 February 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (02) , P02014
Development of a quality assurance process for the SoLid experiment
- Open Access
- 1 September 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (09) , P09005
Optimisation of the scintillation light collection and uniformity for the SoLid experiment
- 1 September 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (09) , P09005
Open AccessOptimisation of the scintillation light collection and uniformity for the SoLid experiment
- Open Access
- 1 May 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (05) , P05005
Performance of a full scale prototype detector at the BR2 reactor for the SoLid experiment
- 1 May 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (05) , P05005
Open AccessPerformance of a full scale prototype detector at the BR2 reactor for the SoLid experiment
- 13 February 2018
- Published by Springer Nature in Optical Review
- Vol. 25 (3) , 429-436
Standoff alpha radiation detection for hot cell imaging and crime scene investigation
- 13 February 2018
- Published by Springer Nature in Optical Review
- Vol. 25 (3) , 429-436
Standoff alpha radiation detection for hot cell imaging and crime scene investigation
- Open Access
- 1 April 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (04) , P04024
A novel segmented-scintillator antineutrino detector
- 1 April 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (04) , P04024
Open AccessA novel segmented-scintillator antineutrino detector
- Open Access
- 22 April 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 24468
Erratum: Optical detection of radon decay in air
Scientific Reports 6: Article number: 21532; published online: 12 February 2016; updated: 22 April 2016 The HTML version of this Article contained a typographical error in the volume number ‘6’, which was incorrectly given as ‘5’. This has now been corrected. In addition, there were typographical errors in the
- 22 April 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 24468
Open AccessErratum: Optical detection of radon decay in air
Scientific Reports 6: Article number: 21532; published online: 12 February 2016; updated: 22 April 2016 The HTML version of this Article contained a typographical error in the volume number ‘6’, which was incorrectly given as ‘5’. This has now been corrected. In addition, there were typographical errors in the
- Open Access
- 12 February 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 21532
Optical detection of radon decay in air
An optical radon detection method is presented. Radon decay is directly measured by observing the secondary radioluminescence light that alpha particles excite in air, and the selectivity of coincident photon detection is further enhanced with online pulse-shape analysis. The sensitivity of a demonstration device was 6.5 cps/Bq/l and the minimum detectable concentration was 12 Bq/m3 with a 1 h integration time. The presented technique paves the way for optical approaches in rapid radon detection, and it can be applied beyond radon to the analysis of any alpha-active sample which can be placed in the measurement chamber.
- 12 February 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 21532
Open AccessOptical detection of radon decay in air
An optical radon detection method is presented. Radon decay is directly measured by observing the secondary radioluminescence light that alpha particles excite in air, and the selectivity of coincident photon detection is further enhanced with online pulse-shape analysis. The sensitivity of a demonstration device was 6.5 cps/Bq/l and the minimum detectable concentration was 12 Bq/m3 with a 1 h integration time. The presented technique paves the way for optical approaches in rapid radon detection, and it can be applied beyond radon to the analysis of any alpha-active sample which can be placed in the measurement chamber.