Stefanie-Peggy Kühnel
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stefanie-Peggy Kühnel has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
John G. Costouros
2 shared publicationsSandro F. Fucentese
2 shared publicationsAaron T. Bigham
Roth McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, Ontario, Canada
1 shared publication- Bruno Fuchs
Balgrist University Hospital, University of Zurich
1 shared publication Christian Gerber
1 shared publication- Christian Gerber
Balgrist Campus Research and Development Center, Zürich, Switzerland
1 shared publication
Latest Publications
- 1 September 2019
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 44 (9) , 797.e1-797.e8
The Capitate-to-Axis-of-Radius Distance (CARD): A New Radiographic Measurement for Wrist and Carpal Alignment in the Sagittal Plane
- 1 September 2019
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 44 (9) , 797.e1-797.e8
The Capitate-to-Axis-of-Radius Distance (CARD): A New Radiographic Measurement for Wrist and Carpal Alignment in the Sagittal Plane
- Open Access
- 1 January 2014
- Published by Wiley in BioMed Research International
- Vol. 2014, 1-10
Accuracy of Patient Specific Cutting Blocks in Total Knee Arthroplasty
Background.Long-term survival of total knee arthroplasty (TKA) is mainly determined by optimal positioning of the components and prosthesis alignment. Implant positioning can be optimized by computer assisted surgery (CAS). Patient specific cutting blocks (PSCB) seem to have the potential to improve component alignment compared to the conventional technique and to be comparable to CAS.Methods.113 knees were selected for PSI and included in this study. Pre- and postoperative mechanical axis, represented by the hip-knee-angle (HKA), the proximal tibial angle (PTA), the distal femoral angle (DFA), and the tibial slope (TS) were measured and the deviation from expected ideal values was calculated.Results.With a margin of error of ±3°, success rates were 81.4% for HKA, 92.0% for TPA, and 94.7% for DFA. With the margin of error for alignments extended to ±4°, we obtained a success rate of 92.9% for the HKA, 98.2% for the PTA, and 99.1% for the DFA. The TS showed postoperative results of 2.86 ± 2.02° (mean change 1.76 ± 2.85°).Conclusion.PSCBs for TKA seem to restore the overall leg alignment. Our data suggest that each individual component can be implanted accurately and the results are comparable to the ones in CAS.
- 1 January 2014
- Published by Wiley in BioMed Research International
- Vol. 2014, 1-10
Open AccessAccuracy of Patient Specific Cutting Blocks in Total Knee Arthroplasty
Background.Long-term survival of total knee arthroplasty (TKA) is mainly determined by optimal positioning of the components and prosthesis alignment. Implant positioning can be optimized by computer assisted surgery (CAS). Patient specific cutting blocks (PSCB) seem to have the potential to improve component alignment compared to the conventional technique and to be comparable to CAS.Methods.113 knees were selected for PSI and included in this study. Pre- and postoperative mechanical axis, represented by the hip-knee-angle (HKA), the proximal tibial angle (PTA), the distal femoral angle (DFA), and the tibial slope (TS) were measured and the deviation from expected ideal values was calculated.Results.With a margin of error of ±3°, success rates were 81.4% for HKA, 92.0% for TPA, and 94.7% for DFA. With the margin of error for alignments extended to ±4°, we obtained a success rate of 92.9% for the HKA, 98.2% for the PTA, and 99.1% for the DFA. The TS showed postoperative results of 2.86 ± 2.02° (mean change 1.76 ± 2.85°).Conclusion.PSCBs for TKA seem to restore the overall leg alignment. Our data suggest that each individual component can be implanted accurately and the results are comparable to the ones in CAS.
- 13 April 2012
- Published by Springer Nature in International Orthopaedics
- Vol. 36 (9) , 1773-1781
The direct anterior approach in hemiarthroplasty for displaced femoral neck fractures
Purpose Hip replacement is the most common treatment for displaced femoral neck fractures in the elderly, and minimally invasive surgery is popular in the field of orthopaedic surgery. This study evaluated the outcome of monopolar hemiarthroplasty by the direct anterior approach over a postoperative period up to 2.5 years. Methods A total of 86 patients with displaced femoral neck fractures were included (mean age of 86.5 years). Surviving patients were reviewed three months (retrospectively) and one to 2.5 years (prospectively) after surgery. One-year mortality was 36 %. Results For all stems, implant positioning with respect to stem alignment, restoration of leg length and femoral offset was correct. Acetabular protrusion was observed in 55 % of the patients one to 2.5 years postoperatively. Subsidence and intraoperative periprosthetic fractures occurred in three patients (3 %) each. All revision stems for postoperative periprosthetic fractures could be implanted using the initial surgical technique without extension of the previous approach. The mean Harris hip score was 85 points at the one to 2.5-year follow-up; 85 % of the patients were satisfied with their hip and 57 % returned to their preoperative level of mobility. Conclusion Based on these findings, hemiarthroplasty for hip fractures can be performed safely and effectively via the direct anterior approach with good functional outcome and high patient satisfaction.
- 13 April 2012
- Published by Springer Nature in International Orthopaedics
- Vol. 36 (9) , 1773-1781
The direct anterior approach in hemiarthroplasty for displaced femoral neck fractures
Purpose Hip replacement is the most common treatment for displaced femoral neck fractures in the elderly, and minimally invasive surgery is popular in the field of orthopaedic surgery. This study evaluated the outcome of monopolar hemiarthroplasty by the direct anterior approach over a postoperative period up to 2.5 years. Methods A total of 86 patients with displaced femoral neck fractures were included (mean age of 86.5 years). Surviving patients were reviewed three months (retrospectively) and one to 2.5 years (prospectively) after surgery. One-year mortality was 36 %. Results For all stems, implant positioning with respect to stem alignment, restoration of leg length and femoral offset was correct. Acetabular protrusion was observed in 55 % of the patients one to 2.5 years postoperatively. Subsidence and intraoperative periprosthetic fractures occurred in three patients (3 %) each. All revision stems for postoperative periprosthetic fractures could be implanted using the initial surgical technique without extension of the previous approach. The mean Harris hip score was 85 points at the one to 2.5-year follow-up; 85 % of the patients were satisfied with their hip and 57 % returned to their preoperative level of mobility. Conclusion Based on these findings, hemiarthroplasty for hip fractures can be performed safely and effectively via the direct anterior approach with good functional outcome and high patient satisfaction.
- 1 May 2011
- Published by SAGE Publications in HIP International
- Vol. 21 (3) , 303-310
Periacetabular Osteotomy: Validation of Intraoperative Fluoroscopic Monitoring of Acetabular Orientation
During periacetabular osteotomy (PAO) the acetabulum is reorientated and the correction monitored by one or more anteroposterior pelvic radiographs. Obtaining these images is time consuming and requires additional technical and personal resources. Such disadvantages could be overcome with the use of fluoroscopy. However, information obtained from fluoroscopy should have the same quality when compared to standard pelvic radiography. Our purpose was to define a suitable fluoroscopy setup and compare the information obtained from the fluoroscopic images to that obtained from a traditional anteroposterior pelvic radiograph. In a consecutive series of 22 patients the acetabular fragment was monitored by a defined intraoperative fluoroscopy setup in addition to a pelvic radiograph. The images were analyzed in random order utilizing common parameters to judge the quality of acetabular orientation. Agreement between the two images was assessed using kappa statistics and compared to the intra-observer reliability obtained from an independent experienced hip surgeon reading the same set of pelvic radiographs on two occasions. In 5 patients the radiation exposure during both fluoroscopy and standard AP pelvic radiography was measured and compared. Agreement of angular measurements of acetabular coverage and version as well as qualitative parameters of acetabular orientation and position between fluoroscopy and pelvic radiographs was at least equal to the intra-observer agreement of an independent experienced hip surgeon reviewing the pelvic radiographs alone. Significantly less radiation exposure was recorded with the use of fluoroscopy when compared to traditional pelvic radiography. We conclude that the use of intraoperative pelvic radiographs during PAO procedures can be replaced by fluoroscopy without quality impairment.
- 1 May 2011
- Published by SAGE Publications in HIP International
- Vol. 21 (3) , 303-310
Periacetabular Osteotomy: Validation of Intraoperative Fluoroscopic Monitoring of Acetabular Orientation
During periacetabular osteotomy (PAO) the acetabulum is reorientated and the correction monitored by one or more anteroposterior pelvic radiographs. Obtaining these images is time consuming and requires additional technical and personal resources. Such disadvantages could be overcome with the use of fluoroscopy. However, information obtained from fluoroscopy should have the same quality when compared to standard pelvic radiography. Our purpose was to define a suitable fluoroscopy setup and compare the information obtained from the fluoroscopic images to that obtained from a traditional anteroposterior pelvic radiograph. In a consecutive series of 22 patients the acetabular fragment was monitored by a defined intraoperative fluoroscopy setup in addition to a pelvic radiograph. The images were analyzed in random order utilizing common parameters to judge the quality of acetabular orientation. Agreement between the two images was assessed using kappa statistics and compared to the intra-observer reliability obtained from an independent experienced hip surgeon reading the same set of pelvic radiographs on two occasions. In 5 patients the radiation exposure during both fluoroscopy and standard AP pelvic radiography was measured and compared. Agreement of angular measurements of acetabular coverage and version as well as qualitative parameters of acetabular orientation and position between fluoroscopy and pelvic radiographs was at least equal to the intra-observer agreement of an independent experienced hip surgeon reviewing the pelvic radiographs alone. Significantly less radiation exposure was recorded with the use of fluoroscopy when compared to traditional pelvic radiography. We conclude that the use of intraoperative pelvic radiographs during PAO procedures can be replaced by fluoroscopy without quality impairment.
- Open Access
- 1 January 2011
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (1) , 251-256
Extraarticular Knee Resection for Sarcomas with Preservation of the Extensor Mechanism: Surgical Technique and Review of Cases
Sarcomas in or contaminating the knee are rare but extremely challenging to treat. Complete resection of the joint is necessary, and often the entire extensor mechanism is removed as well. Reconstruction of the knee is challenging, and the resulting function may be compromised. We describe a surgical technique of extraarticular resection of the knee while preserving the extensor mechanism combined with prosthetic reconstruction. The medial and lateral retinaculum is prepared such that it allows extraarticular placement of K-wires that are driven through the patella and the proximal tibia, serving as in situ guides for the osteotomies. We retrospectively reviewed 11 patients with sarcomas contaminating the knee. The minimum followup was 14 months (mean, 38 months; range, 14–80 months). At last followup patients had a mean flexion of 88° (range, 65°–120°). We observed no complications related to the extensor mechanism, and there was one local recurrence. We believe extraarticular resection of the knee with preservation of the extensor mechanism is a reasonable treatment option for intraarticular sarcomas with functional scores comparable to those for patients having intraarticular resections. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
- 1 January 2011
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (1) , 251-256
Open AccessExtraarticular Knee Resection for Sarcomas with Preservation of the Extensor Mechanism: Surgical Technique and Review of Cases
Sarcomas in or contaminating the knee are rare but extremely challenging to treat. Complete resection of the joint is necessary, and often the entire extensor mechanism is removed as well. Reconstruction of the knee is challenging, and the resulting function may be compromised. We describe a surgical technique of extraarticular resection of the knee while preserving the extensor mechanism combined with prosthetic reconstruction. The medial and lateral retinaculum is prepared such that it allows extraarticular placement of K-wires that are driven through the patella and the proximal tibia, serving as in situ guides for the osteotomies. We retrospectively reviewed 11 patients with sarcomas contaminating the knee. The minimum followup was 14 months (mean, 38 months; range, 14–80 months). At last followup patients had a mean flexion of 88° (range, 65°–120°). We observed no complications related to the extensor mechanism, and there was one local recurrence. We believe extraarticular resection of the knee with preservation of the extensor mechanism is a reasonable treatment option for intraarticular sarcomas with functional scores comparable to those for patients having intraarticular resections. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
- 30 September 2010
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 19 (6) , 950
Erratum to “Total shoulder arthroplasty with an uncemented soft-metal-backed glenoid component” [J Shoulder Elbow Surg 2010;19(4):624-631]
- 30 September 2010
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 19 (6) , 950
Erratum to “Total shoulder arthroplasty with an uncemented soft-metal-backed glenoid component” [J Shoulder Elbow Surg 2010;19(4):624-631]
- 1 June 2010
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 19 (4) , 624-631
Total shoulder arthroplasty with an uncemented soft-metal-backed glenoid component
- 1 June 2010
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 19 (4) , 624-631
Total shoulder arthroplasty with an uncemented soft-metal-backed glenoid component