Dmitry Tikhomirov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dmitry Tikhomirov has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Aleksey Kuzmichev
Federal Scientific Agroengineering Center VIM, 109428 Moscow, Russia
7 shared publications - Aleksei Khimenko
Federal Scientific Agroengineering Center VIM, 109428 Moscow, Russia
6 shared publications - Dmitry Budnikov
Laboratories of Electrical, Thermal Technologies and Energy Saving, Federal Scientific Agroengineering Center VIM, 109428 Moscow, Russia
6 shared publications - Vadim Bolshev
Federal Scientific Agroengineering Center VIM
6 shared publications - Alexey A. Vasilyev
Federal Scientific Agroengineering Center VIM, 109428 Moscow, Russia
3 shared publications - Alexey N. Vasilyev
Federal Scientific Agroengineering Center VIM, 109428 Moscow, Russia
3 shared publications
Latest Publications
- Open Access
- 24 October 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (21) , 2224
Modeling the Thermal Conditions in a Piglet Area with Infrared Heating
A pressing task is to develop a mathematical model and calculation method that most accurately describes the radiant component of heat exchange between an animal and its environment. This will help determine the optimal design parameters and temperature conditions for infrared (IR) heaters in livestock premises. The mathematical models considered describe the animal’s heat exchange with the environment during IR heating. However, they do not take into account the hidden surface temperature of the premises’ enclosing structures and their emissivity factor, or the relationship between animal thermal comfort and the IR heater surface temperature. The proposed radiant heat exchange mathematical model is applicable to diffusely absorbing and radiating isothermic surface system typical of pigsties. It takes into account the emissivity factors of all of the enclosing structures’ surfaces and determines the effective (apparent) premises temperature value tef, corresponding to the thermal comfort conditions. The IR heater surface temperature’s dependence on the emissivity of the pigsty’s enclosing structures (walls, ceiling, and floor) is given, calculated using three methods. As the emissivity of the premises’ enclosing structures decreases, the difference between the results obtained via methods 1, 2, and 3 increases significantly and reaches 50…60% at ε = 0.8. The IR heater radiating surface temperature range is defined in order to create suitable thermal conditions on premises designed for keeping 1- to 4-week-old newborn piglets depending on the enclosing structure temperature and emissivity, taking into account hidden heat exchange surfaces.
- 24 October 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (21) , 2224
Open AccessModeling the Thermal Conditions in a Piglet Area with Infrared Heating
A pressing task is to develop a mathematical model and calculation method that most accurately describes the radiant component of heat exchange between an animal and its environment. This will help determine the optimal design parameters and temperature conditions for infrared (IR) heaters in livestock premises. The mathematical models considered describe the animal’s heat exchange with the environment during IR heating. However, they do not take into account the hidden surface temperature of the premises’ enclosing structures and their emissivity factor, or the relationship between animal thermal comfort and the IR heater surface temperature. The proposed radiant heat exchange mathematical model is applicable to diffusely absorbing and radiating isothermic surface system typical of pigsties. It takes into account the emissivity factors of all of the enclosing structures’ surfaces and determines the effective (apparent) premises temperature value tef, corresponding to the thermal comfort conditions. The IR heater surface temperature’s dependence on the emissivity of the pigsty’s enclosing structures (walls, ceiling, and floor) is given, calculated using three methods. As the emissivity of the premises’ enclosing structures decreases, the difference between the results obtained via methods 1, 2, and 3 increases significantly and reaches 50…60% at ε = 0.8. The IR heater radiating surface temperature range is defined in order to create suitable thermal conditions on premises designed for keeping 1- to 4-week-old newborn piglets depending on the enclosing structure temperature and emissivity, taking into account hidden heat exchange surfaces.
- Open Access
- 22 March 2025
- Published by FSBI All Russian Research Institute for Mechanization in Agriculture (VIM) in Agricultural Machinery and Technologies
- Vol. 19 (1) , 69-76
Selection of Ceiling Fans for the Microclimate System of Livestock Facilities
A literature review revealed that the distribution of air flows and indoor temperatures is influenced by several key factors; including building design; external climatic conditions; internal heat sources; and ventilation system operation. It was demonstrated that livestock buildings exhibit a temperature gradient along the room height; which can reach 6 degrees Celsius or more. An assessment of potential air temperature variations at different heights across various types of livestock facilities was conducted. It has been found that the use of ceiling fans enables a more uniform distribution of air; ensures the standard airflow velocity in the working area; and helps to reduce the concentration of harmful gases and microorganisms in animal zones. (Research purpose) The study aims to develop recommendations for selecting ceiling fans in agricultural premises to equalize air temperature at different heights and ensure uniform distribution of supply air; while maintaining regulated air flow velocity in animal housing areas. (Materials and methods) Various approaches and models for describing the propagation of compact jets and supply air jets from axial ceiling fans were analyzed. (Results and discussion) The range of possible variations in the ceiling fan performance was determined ensuring the normative air velocity in the animal zone; depending on suspension height and blade diameter. General analytical expressions were presented for modeling the propagation of both free and confined compact air jets. Additionally; the behavior of confined compact air jets in buildings with typical height characteristics was analyzed. (Conclusions) The obtained analytical expression defines the relationship between ceiling fan parameters and air flow characteristics; considering the regulated air flow velocity in the working zone. Calculated dependencies and recommendations were provided for determining the optimal number of ceiling fans needed to equalize the air temperature along the room height.
- 22 March 2025
- Published by FSBI All Russian Research Institute for Mechanization in Agriculture (VIM) in Agricultural Machinery and Technologies
- Vol. 19 (1) , 69-76
Open AccessSelection of Ceiling Fans for the Microclimate System of Livestock Facilities
A literature review revealed that the distribution of air flows and indoor temperatures is influenced by several key factors; including building design; external climatic conditions; internal heat sources; and ventilation system operation. It was demonstrated that livestock buildings exhibit a temperature gradient along the room height; which can reach 6 degrees Celsius or more. An assessment of potential air temperature variations at different heights across various types of livestock facilities was conducted. It has been found that the use of ceiling fans enables a more uniform distribution of air; ensures the standard airflow velocity in the working area; and helps to reduce the concentration of harmful gases and microorganisms in animal zones. (Research purpose) The study aims to develop recommendations for selecting ceiling fans in agricultural premises to equalize air temperature at different heights and ensure uniform distribution of supply air; while maintaining regulated air flow velocity in animal housing areas. (Materials and methods) Various approaches and models for describing the propagation of compact jets and supply air jets from axial ceiling fans were analyzed. (Results and discussion) The range of possible variations in the ceiling fan performance was determined ensuring the normative air velocity in the animal zone; depending on suspension height and blade diameter. General analytical expressions were presented for modeling the propagation of both free and confined compact air jets. Additionally; the behavior of confined compact air jets in buildings with typical height characteristics was analyzed. (Conclusions) The obtained analytical expression defines the relationship between ceiling fan parameters and air flow characteristics; considering the regulated air flow velocity in the working zone. Calculated dependencies and recommendations were provided for determining the optimal number of ceiling fans needed to equalize the air temperature along the room height.
- Open Access
- 11 June 2024
- Published by MDPI AG in Agriculture
- Vol. 14 (6) , 922
Raising the Drying Unit for Fruits and Vegetables Energy Efficiency by Application of Thermoelectric Heat Pump
Drying food stuffs and other materials belongs to one of the most commonly used feedstock processing techniques, featuring rather high energy consumption. The major disadvantage of conventional electric convective-type household dryers is substantial thermal energy emission into the environment with a wet exhaust, worked-out drying agent. Among other principal disadvantages common to all dryers of this type, the following have to be mentioned: spatial inhomogeneity of heating a product under processing and that of drying agent distribution due to its temperature reduction and relative humidity growth as it moves upwards. A block diagram and a breadboard model of a convective-type thermoelectric dryer employing a thermoelectric heat pump have been designed. In our approach, a product is treated with the help of a drying agent (normally, heated air) with partial exhaust-air recirculation and heat recovery. Laboratory studies of the drying process have been carried out using apple fruits as a test material in order to evaluate the power consumed for evaporation of 1 kg of water in the newly developed convective-type thermoelectric drying unit. Physical parameters of apple fruits before and after drying both in the thermoelectric drying unit and in a conventional series-produced convective-type domestic dryer have been reported. The energy efficiency of the newly designed drying unit has been compared with that of some series-produced samples. It has been found out that, unlike conventional convective-type dryers, the breadboard model of the developed thermoelectric drying unit features a smoother product drying process owing to the presence of side air channels and more effective drying agent path organization in the processing chamber. This conclusion was supported by the results of the carried out tests. Application of thermoelectric heat pumps with the function of the exhaust drying agent heat recovery will make it possible to reduce the drying agent heater installed capacity and the power consumed by the newly designed convective-type thermoelectric drying unit by up to 20% in the course of the drying process, compared to series-produced household convective-type dryers.
- 11 June 2024
- Published by MDPI AG in Agriculture
- Vol. 14 (6) , 922
Open AccessRaising the Drying Unit for Fruits and Vegetables Energy Efficiency by Application of Thermoelectric Heat Pump
Drying food stuffs and other materials belongs to one of the most commonly used feedstock processing techniques, featuring rather high energy consumption. The major disadvantage of conventional electric convective-type household dryers is substantial thermal energy emission into the environment with a wet exhaust, worked-out drying agent. Among other principal disadvantages common to all dryers of this type, the following have to be mentioned: spatial inhomogeneity of heating a product under processing and that of drying agent distribution due to its temperature reduction and relative humidity growth as it moves upwards. A block diagram and a breadboard model of a convective-type thermoelectric dryer employing a thermoelectric heat pump have been designed. In our approach, a product is treated with the help of a drying agent (normally, heated air) with partial exhaust-air recirculation and heat recovery. Laboratory studies of the drying process have been carried out using apple fruits as a test material in order to evaluate the power consumed for evaporation of 1 kg of water in the newly developed convective-type thermoelectric drying unit. Physical parameters of apple fruits before and after drying both in the thermoelectric drying unit and in a conventional series-produced convective-type domestic dryer have been reported. The energy efficiency of the newly designed drying unit has been compared with that of some series-produced samples. It has been found out that, unlike conventional convective-type dryers, the breadboard model of the developed thermoelectric drying unit features a smoother product drying process owing to the presence of side air channels and more effective drying agent path organization in the processing chamber. This conclusion was supported by the results of the carried out tests. Application of thermoelectric heat pumps with the function of the exhaust drying agent heat recovery will make it possible to reduce the drying agent heater installed capacity and the power consumed by the newly designed convective-type thermoelectric drying unit by up to 20% in the course of the drying process, compared to series-produced household convective-type dryers.
- Open Access
- 22 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (5) , 1772
Studying the Influence of Moisture Content in Grain on the Efficiency of the Microwave Field Transfer into a Grain Layer with the Use of a Computer Model
The objective of these studies was to determine the dependence of the distribution of the microwave field into a grain layer and the efficiency of energy transfer from the magnetron into the grain layer, via a waveguide, on the moisture content. The subject of the research was a semicircular waveguide with slot radiators that supply a microwave field to the grain surrounding the waveguide. The change in the directional diagram of the microwave field in the longitudinal direction of the waveguide was studied using CST Microwave Studio 2019 software. It was found that the change in the moisture content of the processed grain leads to a significant change in both the radiation and total efficiency values of the waveguide. For instance, the radiation efficiency of the waveguide decreases by 15.1% (from 68.729 dB to 58.294 dB) when the moisture content of the processed grain increases from 14% to 26%. The total radiation efficiency also decreases (from 11.27 dB to 21.7 dB). In this case, not only the value of the radiation efficiency but also the shape of its dependence on the magnetron radiation frequency change. The results of this study enable the formulation of a requirement for a selective approach to the alignment of emitting waveguides depending on the moisture content of the processed grain. Data were obtained on the change in the Q-factor for resonators in which grain layers are processed, depending on the variation in grain moisture content. The research results suggest that when designing microwave convective zones for grain processing, the quality factor of the resonator should not be considered as the primary parameter. The main focus should be on maximizing the radiation efficiency of the waveguides.
- 22 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (5) , 1772
Open AccessStudying the Influence of Moisture Content in Grain on the Efficiency of the Microwave Field Transfer into a Grain Layer with the Use of a Computer Model
The objective of these studies was to determine the dependence of the distribution of the microwave field into a grain layer and the efficiency of energy transfer from the magnetron into the grain layer, via a waveguide, on the moisture content. The subject of the research was a semicircular waveguide with slot radiators that supply a microwave field to the grain surrounding the waveguide. The change in the directional diagram of the microwave field in the longitudinal direction of the waveguide was studied using CST Microwave Studio 2019 software. It was found that the change in the moisture content of the processed grain leads to a significant change in both the radiation and total efficiency values of the waveguide. For instance, the radiation efficiency of the waveguide decreases by 15.1% (from 68.729 dB to 58.294 dB) when the moisture content of the processed grain increases from 14% to 26%. The total radiation efficiency also decreases (from 11.27 dB to 21.7 dB). In this case, not only the value of the radiation efficiency but also the shape of its dependence on the magnetron radiation frequency change. The results of this study enable the formulation of a requirement for a selective approach to the alignment of emitting waveguides depending on the moisture content of the processed grain. Data were obtained on the change in the Q-factor for resonators in which grain layers are processed, depending on the variation in grain moisture content. The research results suggest that when designing microwave convective zones for grain processing, the quality factor of the resonator should not be considered as the primary parameter. The main focus should be on maximizing the radiation efficiency of the waveguides.
- Open Access
- 2 February 2024
- Published by MDPI AG in Preprints.org
Studying the Influence of Moisture Content in Grain on the Efficiency of the Microwave Field Transfer into a Grain Layer with the Use of Computer Model
The objective of these studies was to determine the dependence of the distribution of the microwave field into a grain layer and the efficiency of energy transfer from the magnetron into the grain layer, via a waveguide, on the moisture content. The subject of the research was a semicircular waveguide with slot radiators that supply a microwave field to the grain surrounding the waveguide. The change in the directional diagram of the microwave field in the longitudinal direction of the waveguide was studied using CST Microwave Studio 2019 software. It was found that the change in the moisture content of the processed grain leads to a significant change in both the radiation and total efficiency values of the waveguide. For instance, the radiation efficiency of the waveguide decreases by 15.1% (from 68.729 dB to 58.294 dB) when the moisture content of the processed grain increases from 14% to 26%. The total radiation efficiency also decreases (from 11.27 dB to 21.7 dB). In this case, not only the value of the radiation efficiency but also the shape of its dependence on the magnetron radiation frequency change. Data were obtained on the change in the Q-factor for resonators in which grain layers are processed, depending on the variation in grain moisture content.
- 2 February 2024
- Published by MDPI AG in Preprints.org
Open AccessStudying the Influence of Moisture Content in Grain on the Efficiency of the Microwave Field Transfer into a Grain Layer with the Use of Computer Model
The objective of these studies was to determine the dependence of the distribution of the microwave field into a grain layer and the efficiency of energy transfer from the magnetron into the grain layer, via a waveguide, on the moisture content. The subject of the research was a semicircular waveguide with slot radiators that supply a microwave field to the grain surrounding the waveguide. The change in the directional diagram of the microwave field in the longitudinal direction of the waveguide was studied using CST Microwave Studio 2019 software. It was found that the change in the moisture content of the processed grain leads to a significant change in both the radiation and total efficiency values of the waveguide. For instance, the radiation efficiency of the waveguide decreases by 15.1% (from 68.729 dB to 58.294 dB) when the moisture content of the processed grain increases from 14% to 26%. The total radiation efficiency also decreases (from 11.27 dB to 21.7 dB). In this case, not only the value of the radiation efficiency but also the shape of its dependence on the magnetron radiation frequency change. Data were obtained on the change in the Q-factor for resonators in which grain layers are processed, depending on the variation in grain moisture content.
- Open Access
- 17 June 2023
- Published by MDPI AG in Agriculture
- Vol. 13 (6) , 1259
Study of Potential Application Air Curtains in Livestock Premises at Cattle Management Farms
Recommendations on the selection of air curtains and the calculation of their parameters for livestock premises in cattle management farms are made. The air curtain functioning principle is analyzed from the air jet theory point of view. The block diagram and modular design of air curtains with a variable air jet direction vector and with controlled slit width are designed. Laboratory tests of the newly designed air curtain structure are performed in accordance with the microclimate requirements for the cattle management farm premises. Based on the experimental results, the major air curtain parameters are calculated for the range from 10° to 60° of angle α between the direction of the air jet outward from the air curtain slit and aperture plane, and for the air curtain slit width b0 in the range from 0.05 m to 0.15 m with the account of the wind speed Vw variations. Calculated values for amounts of energy that have to be consumed to ensure the required air jet velocity, in the output from the air curtain, and those for the quantity of thermal energy required to heat the air supplied to the air curtain, depending on the angle α and on the slit width b0, can be helpful for selecting the power capacity of both the air curtain fan and electric heater. A block diagram of the air curtain control for cattle management farm premises is designed, enabling automatic control of the airflow rate, the angle of the air jet output from the air curtain slit, and the temperature of the heated air supplied to the air curtain, considering particular climate conditions. According to the preliminary estimate, applications of the newly designed air curtain will make it possible to reduce the energy consumed to maintain the required microclimate conditions in cattle management premises by 10% to 15% in the cold period.
- 17 June 2023
- Published by MDPI AG in Agriculture
- Vol. 13 (6) , 1259
Open AccessStudy of Potential Application Air Curtains in Livestock Premises at Cattle Management Farms
Recommendations on the selection of air curtains and the calculation of their parameters for livestock premises in cattle management farms are made. The air curtain functioning principle is analyzed from the air jet theory point of view. The block diagram and modular design of air curtains with a variable air jet direction vector and with controlled slit width are designed. Laboratory tests of the newly designed air curtain structure are performed in accordance with the microclimate requirements for the cattle management farm premises. Based on the experimental results, the major air curtain parameters are calculated for the range from 10° to 60° of angle α between the direction of the air jet outward from the air curtain slit and aperture plane, and for the air curtain slit width b0 in the range from 0.05 m to 0.15 m with the account of the wind speed Vw variations. Calculated values for amounts of energy that have to be consumed to ensure the required air jet velocity, in the output from the air curtain, and those for the quantity of thermal energy required to heat the air supplied to the air curtain, depending on the angle α and on the slit width b0, can be helpful for selecting the power capacity of both the air curtain fan and electric heater. A block diagram of the air curtain control for cattle management farm premises is designed, enabling automatic control of the airflow rate, the angle of the air jet output from the air curtain slit, and the temperature of the heated air supplied to the air curtain, considering particular climate conditions. According to the preliminary estimate, applications of the newly designed air curtain will make it possible to reduce the energy consumed to maintain the required microclimate conditions in cattle management premises by 10% to 15% in the cold period.
- Open Access
- 25 April 2023
- Published by MDPI AG in Agriculture
- Vol. 13 (5) , 948
Local Heating through the Application of a Thermoelectric Heat Pump for Prenursery Pigs
Mathematical formulation of the animal thermal status has been developed, with the account of two convenience conditions and heat balance, for the floor-mounted heating panel for prenursery pigs. The borders of the heat flux variation range for the floor-mounted heating panel have been determined corresponding to the animal-friendly conditions for prenursery pigs of various age groups. The block diagram of the energy-saving floor-mounted heating panel, comprising the thermoelectric assembly operating in the heat pump mode, has been designed. The method has been described and the corresponding calculations have been made for the basic thermal parameters of the floor-mounted local heating installation, for prenursery pigs, with the application of a thermoelectric heat pump. The experimental installation sample of 116 W thermal capacity (for the heat transfer coefficient from 0.9 W·m−2·K−1 to 1.0 W·m−2·K−1 and floor temperature in the range of 5 °C to 6 °C) has been developed and manufactured for local heating for prenursery pigs managed in gestation crates. Laboratory tests of the experimental sample of the floor-mounted heating panel have demonstrated high energy efficiency of the heating installation under development. The energy-saving effect (approx. 15% compared to the series-produced equipment designed for local heating of young stock) of the developed installation was achieved owing to the partial heat recuperation of the exhaust ventilating air.
- 25 April 2023
- Published by MDPI AG in Agriculture
- Vol. 13 (5) , 948
Open AccessLocal Heating through the Application of a Thermoelectric Heat Pump for Prenursery Pigs
Mathematical formulation of the animal thermal status has been developed, with the account of two convenience conditions and heat balance, for the floor-mounted heating panel for prenursery pigs. The borders of the heat flux variation range for the floor-mounted heating panel have been determined corresponding to the animal-friendly conditions for prenursery pigs of various age groups. The block diagram of the energy-saving floor-mounted heating panel, comprising the thermoelectric assembly operating in the heat pump mode, has been designed. The method has been described and the corresponding calculations have been made for the basic thermal parameters of the floor-mounted local heating installation, for prenursery pigs, with the application of a thermoelectric heat pump. The experimental installation sample of 116 W thermal capacity (for the heat transfer coefficient from 0.9 W·m−2·K−1 to 1.0 W·m−2·K−1 and floor temperature in the range of 5 °C to 6 °C) has been developed and manufactured for local heating for prenursery pigs managed in gestation crates. Laboratory tests of the experimental sample of the floor-mounted heating panel have demonstrated high energy efficiency of the heating installation under development. The energy-saving effect (approx. 15% compared to the series-produced equipment designed for local heating of young stock) of the developed installation was achieved owing to the partial heat recuperation of the exhaust ventilating air.
- Open Access
- 23 October 2022
- Published by MDPI AG in Agriculture
- Vol. 12 (11) , 1753
Electric Heating System with Thermal Storage Units and Ceiling Fans for Cattle-Breeding Farms
A combined energy–saving heat supply system was proposed that included a combined ETS unit and a ceiling fan, and provided the normative air parameters in a livestock room, with an air temperature of −17 °C and air relative humidity (ARH) of −75%. A heat supply system of a preventive maintenance premises for calves was chosen as the subject of the study. Comparative analysis of the temperature and ARH distribution with height in the preventive maintenance premises, was carried out, with and without a ceiling fan. The study showed that, during the heating period, application of the ceiling fans helped to raise the air temperature and to reduce ARH, in the areas where young stock is located, in accordance with the normative indicators. The energy-saving effect was achieved by supplying warmer ventilation air, which accumulated in the upper zone of the premises from the ceiling fan to the locations of the animals. At the same time, there was a decrease in the consumption of electric energy for the heat supply system of up to 14%.
- 23 October 2022
- Published by MDPI AG in Agriculture
- Vol. 12 (11) , 1753
Open AccessElectric Heating System with Thermal Storage Units and Ceiling Fans for Cattle-Breeding Farms
A combined energy–saving heat supply system was proposed that included a combined ETS unit and a ceiling fan, and provided the normative air parameters in a livestock room, with an air temperature of −17 °C and air relative humidity (ARH) of −75%. A heat supply system of a preventive maintenance premises for calves was chosen as the subject of the study. Comparative analysis of the temperature and ARH distribution with height in the preventive maintenance premises, was carried out, with and without a ceiling fan. The study showed that, during the heating period, application of the ceiling fans helped to raise the air temperature and to reduce ARH, in the areas where young stock is located, in accordance with the normative indicators. The energy-saving effect was achieved by supplying warmer ventilation air, which accumulated in the upper zone of the premises from the ceiling fan to the locations of the animals. At the same time, there was a decrease in the consumption of electric energy for the heat supply system of up to 14%.
- 8 February 2021
- Published by Springer Nature
- p. 1146-1155
Floor-Mounted Heating of Piglets with the Use of Thermoelectricity
- 8 February 2021
- Published by Springer Nature
- p. 1146-1155
Floor-Mounted Heating of Piglets with the Use of Thermoelectricity