John P. Breinholt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
John P. Breinholt has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Akanksha Thakkar
Houston Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Texas
1 shared publication - Ali Dodge-Khatami
Division of Pediatric and Congenital Heart Surgery, University Clinic RWTH, Aachen, Germany
1 shared publication - Brady S. Moffett
Department of Pharmacy Texas Children's Hospital Houston Texas USA
1 shared publication - Brian Karahalios
Houston Methodist Hospital, Houston, Texas, USA
1 shared publication Byron Garn
Phoenix Children's Hospital, Phoenix, AZ, USA
1 shared publicationC. Huie Lin
Houston Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Texas
1 shared publication
Latest Publications
- 6 March 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (2) , 361-364
Intentional bioprosthetic tricuspid valve fracture to facilitate transcatheter valve‐in‐valve deployment
While transcatheter valve‐in‐valve (ViV) implantation may reduce the number of lifetime surgical reinterventions in some patients with congenital heart disease, in other patients the bioprosthetic valve ring can lead to patient‐prosthesis mismatch due to reduction of internal diameter if a transcatheter valve is implanted. A 49‐year‐old woman with multiple prior cardiac surgeries presented with heart failure due to bioprosthetic tricuspid valve stenosis. Initial predilation valvuloplasty suggested conventional ViV implant would produce patient‐prosthesis mismatch, therefore, we intentionally fractured the bioprosthetic valve ring to facilitate optimal hemodynamics with implantation of a 29 mm transcatheter valve.
- 6 March 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (2) , 361-364
Intentional bioprosthetic tricuspid valve fracture to facilitate transcatheter valve‐in‐valve deployment
While transcatheter valve‐in‐valve (ViV) implantation may reduce the number of lifetime surgical reinterventions in some patients with congenital heart disease, in other patients the bioprosthetic valve ring can lead to patient‐prosthesis mismatch due to reduction of internal diameter if a transcatheter valve is implanted. A 49‐year‐old woman with multiple prior cardiac surgeries presented with heart failure due to bioprosthetic tricuspid valve stenosis. Initial predilation valvuloplasty suggested conventional ViV implant would produce patient‐prosthesis mismatch, therefore, we intentionally fractured the bioprosthetic valve ring to facilitate optimal hemodynamics with implantation of a 29 mm transcatheter valve.
- 28 February 2019
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 29 (3) , 363-368
Results of international assistance for a paediatric heart surgery programme in a single Ukrainian centre
Background: Surgery for CHD has been slow to develop in parts of the former Soviet Union. The impact of an 8-year surgical assistance programme between an emerging centre and a multi-disciplinary international team that comprised healthcare professionals from developed cardiac programmes is analysed and presented.Material and methods: The international paediatric assistance programme included five main components – intermittent clinical visits to the site annually, medical education, biomedical engineering support, nurse empowerment, and team-based practice development. Data were analysed from visiting teams and local databases before and since commencement of assistance in 2007 (era A: 2000–2007; era B: 2008–2015). The following variables were compared between periods: annual case volume, operative mortality, case complexity based on Risk Adjustment for Congenital Heart Surgery (RACHS-1), and RACHS-adjusted standardised mortality ratio.Results: A total of 154 RACHS-classifiable operations were performed during era A, with a mean annual case volume by local surgeons of 19.3 at 95% confidence interval 14.3–24.2, with an operative mortality of 4.6% and a standardised mortality ratio of 2.1. In era B, surgical volume increased to a mean of 103.1 annual cases (95% confidence interval 69.1–137.2, p<0.0001). There was a non-significant (p=0.84) increase in operative mortality (5.7%), but a decrease in standardised mortality ratio (1.2) owing to an increase in case complexity. In era B, the proportion of local surgeon-led surgeries during visits from the international team increased from 0% (0/27) in 2008 to 98% (58/59) in the final year of analysis.Conclusions: The model of assistance described in this report led to improved adjusted mortality, increased case volume, complexity, and independent operating skills.
- 28 February 2019
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 29 (3) , 363-368
Results of international assistance for a paediatric heart surgery programme in a single Ukrainian centre
Background: Surgery for CHD has been slow to develop in parts of the former Soviet Union. The impact of an 8-year surgical assistance programme between an emerging centre and a multi-disciplinary international team that comprised healthcare professionals from developed cardiac programmes is analysed and presented.Material and methods: The international paediatric assistance programme included five main components – intermittent clinical visits to the site annually, medical education, biomedical engineering support, nurse empowerment, and team-based practice development. Data were analysed from visiting teams and local databases before and since commencement of assistance in 2007 (era A: 2000–2007; era B: 2008–2015). The following variables were compared between periods: annual case volume, operative mortality, case complexity based on Risk Adjustment for Congenital Heart Surgery (RACHS-1), and RACHS-adjusted standardised mortality ratio.Results: A total of 154 RACHS-classifiable operations were performed during era A, with a mean annual case volume by local surgeons of 19.3 at 95% confidence interval 14.3–24.2, with an operative mortality of 4.6% and a standardised mortality ratio of 2.1. In era B, surgical volume increased to a mean of 103.1 annual cases (95% confidence interval 69.1–137.2, p<0.0001). There was a non-significant (p=0.84) increase in operative mortality (5.7%), but a decrease in standardised mortality ratio (1.2) owing to an increase in case complexity. In era B, the proportion of local surgeon-led surgeries during visits from the international team increased from 0% (0/27) in 2008 to 98% (58/59) in the final year of analysis.Conclusions: The model of assistance described in this report led to improved adjusted mortality, increased case volume, complexity, and independent operating skills.
- Open Access
- 13 June 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (2) , 353-357
Transcatheter closure of a sinus venosus atrial septal defect using 3D printing and image fusion guidance
A 63‐year‐old man with cirrhosis, hepatocellular carcinoma, and coagulopathy was diagnosed with a sinus venosus atrial septal defect (ASD) and partial anomalous pulmonary venous return (PAPVR) of the right upper pulmonary vein (RUPV). Transcatheter repair by positioning a stent graft in the superior vena cava was planned. Based on three‐dimensional (3D) reconstruction of gated cardiac CTA, a 28 mm × 7 cm Endurant II® aortic extension stent graft (Medtronic, MN) was chosen. A 3D model printed from the CTA was used to simulate device deployment, demonstrating successful exclusion of the sinus venosus ASD with return of the RUPV to the left atrium (LA). Post simulation, the 3D model was used for informed consent. The patient was then taken to the hybrid operating room. On‐table cone beam CT was performed and registered with the CTA images. This enabled overlay of 3D regions of interest to live 2D fluoroscopy. The stent graft was then deployed using 3D regions of interest for guidance. Hemodynamics and angiography demonstrated successful exclusion of the sinus venosus ASD and unobstructed return of RUPV to the LA. This is the first report of comprehensive use of contemporary imaging for planning, simulation, patient consent, and procedural guidance for patient‐centered complex structural intervention in repair of sinus venosus ASD with PAPVR. We propose this as a process model for continued innovation in structural interventions.
- 13 June 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (2) , 353-357
Open AccessTranscatheter closure of a sinus venosus atrial septal defect using 3D printing and image fusion guidance
A 63‐year‐old man with cirrhosis, hepatocellular carcinoma, and coagulopathy was diagnosed with a sinus venosus atrial septal defect (ASD) and partial anomalous pulmonary venous return (PAPVR) of the right upper pulmonary vein (RUPV). Transcatheter repair by positioning a stent graft in the superior vena cava was planned. Based on three‐dimensional (3D) reconstruction of gated cardiac CTA, a 28 mm × 7 cm Endurant II® aortic extension stent graft (Medtronic, MN) was chosen. A 3D model printed from the CTA was used to simulate device deployment, demonstrating successful exclusion of the sinus venosus ASD with return of the RUPV to the left atrium (LA). Post simulation, the 3D model was used for informed consent. The patient was then taken to the hybrid operating room. On‐table cone beam CT was performed and registered with the CTA images. This enabled overlay of 3D regions of interest to live 2D fluoroscopy. The stent graft was then deployed using 3D regions of interest for guidance. Hemodynamics and angiography demonstrated successful exclusion of the sinus venosus ASD and unobstructed return of RUPV to the LA. This is the first report of comprehensive use of contemporary imaging for planning, simulation, patient consent, and procedural guidance for patient‐centered complex structural intervention in repair of sinus venosus ASD with PAPVR. We propose this as a process model for continued innovation in structural interventions.
- 15 April 2008
- Published by Springer Nature in Pediatric Cardiology
- Vol. 29 (4) , 804-807
Successful Use of Bivalirudin for Superior Vena Cava Recanalization and Stent Placement in a Child with Heparin-Induced Thrombocytopenia
Heparin-induced thrombocytopenia (HIT) is a potentially life-threatening, adverse effect of heparin therapy. Patients with this complication require an alternative approach to anticoagulation. Bivalirudin is a direct thrombin inhibitor with an efficacy comparable to that of heparin, a short half-life, and reduced bleeding complications in adults. We present the case of a 2-year-old boy with HIT Type II who underwent recanalization of an occluded superior vena cava and stent placement, utilizing bivalirudin as anticoagulant.
- 15 April 2008
- Published by Springer Nature in Pediatric Cardiology
- Vol. 29 (4) , 804-807
Successful Use of Bivalirudin for Superior Vena Cava Recanalization and Stent Placement in a Child with Heparin-Induced Thrombocytopenia
Heparin-induced thrombocytopenia (HIT) is a potentially life-threatening, adverse effect of heparin therapy. Patients with this complication require an alternative approach to anticoagulation. Bivalirudin is a direct thrombin inhibitor with an efficacy comparable to that of heparin, a short half-life, and reduced bleeding complications in adults. We present the case of a 2-year-old boy with HIT Type II who underwent recanalization of an occluded superior vena cava and stent placement, utilizing bivalirudin as anticoagulant.