Andrew D. Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew D. Brown has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Daniel J. Tollin
Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora 2 , Colorado 80045, USA
6 shared publications- Daniel J. Tollin
Department of Physiology & Biophysics, University of Colorado School of Medicine, Aurora, CO, USA
6 shared publications - G. Christopher Stecker
University of Washington Department of Speech and Hearing Sciences 1417 NE 42nd Street, Seattle, Washington 98105
4 shared publications - Nathaniel T. Greene
Department of Otolaryngology, University of Colorado School of Medicine, University of Colorado Anschutz Medical Campus, 12631 E 17th Ave. MS B205, Aurora, CO 80045, USA
4 shared publications David J. Audet
3 shared publications- Joseph A. Sisneros
University of Washington
3 shared publications
Latest Publications
- Open Access
- 28 October 2026
- Published by Springer Nature
- p. 913-926
Auditory Evoked Potentials in Aquatic Animals: A Review of Threshold Determination Methods
- 28 October 2026
- Published by Springer Nature
- p. 913-926
Open AccessAuditory Evoked Potentials in Aquatic Animals: A Review of Threshold Determination Methods
- Open Access
- 1 May 2026
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 6 (5)
Fishing with sound: Insights into the plainfin midshipman's reproductive ecology from field acoustic playbacks
The long-duration advertisement “hums” produced by type I male plainfin midshipman fish (Porichthys notatus) are tonal signals consisting of a fundamental frequency and multiple harmonics. Using acoustic playback of synthetic, hum-like stimuli under natural conditions, we found that the fundamental frequency is likely required for females' final entry into a type I male's nest, whereas higher harmonics may play a limited role. We found no evidence of phonotaxis in type I and type II males. Additionally, the observed decrease in body size of captured individuals over the breeding season suggests that larger individuals migrate earlier to spawning sites.
- 1 May 2026
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 6 (5)
Open AccessFishing with sound: Insights into the plainfin midshipman's reproductive ecology from field acoustic playbacks
The long-duration advertisement “hums” produced by type I male plainfin midshipman fish (Porichthys notatus) are tonal signals consisting of a fundamental frequency and multiple harmonics. Using acoustic playback of synthetic, hum-like stimuli under natural conditions, we found that the fundamental frequency is likely required for females' final entry into a type I male's nest, whereas higher harmonics may play a limited role. We found no evidence of phonotaxis in type I and type II males. Additionally, the observed decrease in body size of captured individuals over the breeding season suggests that larger individuals migrate earlier to spawning sites.
- Open Access
- 1 April 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 159 (4) , 3130-3147
Two-dimensional sound localization during hearing protector use: Human performance and acoustic prediction
Hearing protection devices (HPDs) are essential safety equipment for workers in noisy settings, but can degrade auditory perception. For example, dozens of studies have demonstrated that HPDs disrupt sound source localization, a critical limitation for some use cases. However, a majority of studies have evaluated performance for a small sample of practiced participants, a small number of source locations, and/or a small set of HPDs, making it difficult to distill generalizable factors affecting localization performance. Here, sound localization was measured in 130 participants across two study sites. At each site, test stimuli spanned 24 source locations (eight azimuths, three elevations) in five different listening conditions: open ears (baseline), and four different HPDs. In all conditions, test stimuli were brief noise bursts; in some conditions, multiple source levels or durations were tested. Parallel acoustic measurements were completed at each site using a binaural manikin. Data suggest that HPDs may disrupt localization via at least three means: (1) attenuation can render air-conducted localization cues inaudible, (2) frequency distortion can disrupt audible monaural localization cues, and (3) asymmetric attenuation can disrupt audible binaural localization cues. However, data also evince large intersubject variability and task-dependent biases not readily captured using conventional acoustic measures.
- 1 April 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 159 (4) , 3130-3147
Open AccessTwo-dimensional sound localization during hearing protector use: Human performance and acoustic prediction
Hearing protection devices (HPDs) are essential safety equipment for workers in noisy settings, but can degrade auditory perception. For example, dozens of studies have demonstrated that HPDs disrupt sound source localization, a critical limitation for some use cases. However, a majority of studies have evaluated performance for a small sample of practiced participants, a small number of source locations, and/or a small set of HPDs, making it difficult to distill generalizable factors affecting localization performance. Here, sound localization was measured in 130 participants across two study sites. At each site, test stimuli spanned 24 source locations (eight azimuths, three elevations) in five different listening conditions: open ears (baseline), and four different HPDs. In all conditions, test stimuli were brief noise bursts; in some conditions, multiple source levels or durations were tested. Parallel acoustic measurements were completed at each site using a binaural manikin. Data suggest that HPDs may disrupt localization via at least three means: (1) attenuation can render air-conducted localization cues inaudible, (2) frequency distortion can disrupt audible monaural localization cues, and (3) asymmetric attenuation can disrupt audible binaural localization cues. However, data also evince large intersubject variability and task-dependent biases not readily captured using conventional acoustic measures.
- Open Access
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
Transmission of Binaural Cues by Bilateral Cochlear Implants: A Comparison of Spectral Peak-Picking and Constantly Stimulating Strategies
Cochlear implants (CIs) effectively restore speech understanding in quiet for many recipients. However, bilateral CI listeners continue to perform poorer than acoustic-hearing listeners on spatial-hearing tasks such as sound localization. One explanation is that stimulation strategies and the lack of coordination across sound processors degrade the fidelity of binaural cues. To provide further insight on this issue, this study compared the binaural cues transmitted by two CI stimulation strategies: a spectral peak-picking stimulation strategy and a constantly stimulating strategy. Two clinical CI sound processors were placed on a binaural manikin centered in a horizontal ring of loudspeakers in an anechoic chamber. Speech and non-speech stimuli were presented from the loudspeakers and the resulting electrical pulse trains were recorded. Envelope interaural time differences and interaural level differences were extracted from the recordings. Binaural cues were compared between the two stimulation strategies and against acoustic cues measured using behind-the-ear microphones. Results showed that, compared to the constantly stimulating strategy, the spectral peak-picking strategy led to more variable and less monotonic binaural cues, which could constrain sound-localization abilities. These findings highlight the need for bilateral coordination of CIs in multiple domains, including electrode selection in peak-picking stimulation strategies and pulse timing. (198/250).
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
Open AccessTransmission of Binaural Cues by Bilateral Cochlear Implants: A Comparison of Spectral Peak-Picking and Constantly Stimulating Strategies
Cochlear implants (CIs) effectively restore speech understanding in quiet for many recipients. However, bilateral CI listeners continue to perform poorer than acoustic-hearing listeners on spatial-hearing tasks such as sound localization. One explanation is that stimulation strategies and the lack of coordination across sound processors degrade the fidelity of binaural cues. To provide further insight on this issue, this study compared the binaural cues transmitted by two CI stimulation strategies: a spectral peak-picking stimulation strategy and a constantly stimulating strategy. Two clinical CI sound processors were placed on a binaural manikin centered in a horizontal ring of loudspeakers in an anechoic chamber. Speech and non-speech stimuli were presented from the loudspeakers and the resulting electrical pulse trains were recorded. Envelope interaural time differences and interaural level differences were extracted from the recordings. Binaural cues were compared between the two stimulation strategies and against acoustic cues measured using behind-the-ear microphones. Results showed that, compared to the constantly stimulating strategy, the spectral peak-picking strategy led to more variable and less monotonic binaural cues, which could constrain sound-localization abilities. These findings highlight the need for bilateral coordination of CIs in multiple domains, including electrode selection in peak-picking stimulation strategies and pulse timing. (198/250).
- Open Access
- 6 March 2025
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 64 (10) , 1055-1062
Towards improved measurements of bone conduction auditory brainstem responses in infants and adults: mitigation of stimulus artefact
To reduce the amplitude of stimulus artefacts present in bone conduction auditory brainstem response (BC ABR) measurements. Electromagnetic shielding was applied to the surface of a clinical BC transducer. A foam pad was also placed on the shielded mastoid-contacting plate of the transducer. Acoustic impacts of these modifications were evaluated using an artificial mastoid. Unmodified and modified (shielding with pad) transducers were then used to elicit BC ABRs in adults and infants. Stimulus artefact amplitudes were compared across transducers. Six adults (24-42 years old) and 13 typically developing infants (mean age 48.77 days) with no sensorineural hearing loss. Shielding alone slightly decreased acoustic transducer output above approximately 1000 Hz. The addition of a foam pad largely negated this loss, while lower-frequency (500-1000 Hz) acoustic transducer output was slightly increased. The modified transducer produced significantly less stimulus artefact, although variation across subjects was also evident. In a clinical setting, Wave V was detected at similar rates for both transducers. While artefact was not eliminated, direct attenuation of artefact amplitude (versus software-based mitigation strategies) could simplify BC ABR and other evoked potential measurement protocols and support more stringent artefact rejection criteria to yield more informative recordings.
- 6 March 2025
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 64 (10) , 1055-1062
Open AccessTowards improved measurements of bone conduction auditory brainstem responses in infants and adults: mitigation of stimulus artefact
To reduce the amplitude of stimulus artefacts present in bone conduction auditory brainstem response (BC ABR) measurements. Electromagnetic shielding was applied to the surface of a clinical BC transducer. A foam pad was also placed on the shielded mastoid-contacting plate of the transducer. Acoustic impacts of these modifications were evaluated using an artificial mastoid. Unmodified and modified (shielding with pad) transducers were then used to elicit BC ABRs in adults and infants. Stimulus artefact amplitudes were compared across transducers. Six adults (24-42 years old) and 13 typically developing infants (mean age 48.77 days) with no sensorineural hearing loss. Shielding alone slightly decreased acoustic transducer output above approximately 1000 Hz. The addition of a foam pad largely negated this loss, while lower-frequency (500-1000 Hz) acoustic transducer output was slightly increased. The modified transducer produced significantly less stimulus artefact, although variation across subjects was also evident. In a clinical setting, Wave V was detected at similar rates for both transducers. While artefact was not eliminated, direct attenuation of artefact amplitude (versus software-based mitigation strategies) could simplify BC ABR and other evoked potential measurement protocols and support more stringent artefact rejection criteria to yield more informative recordings.
- Open Access
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4_suppleme) , A237
Accounting for individual differences in the effects of hearing protectors on sound source localization
Modern hearing protection devices (HPDs) mitigate the risk of noise-induced hearing loss when used as intended, but negative auditory perceptual side-effects continue to limit usability in critical settings. Dozens of studies, including previous studies by our group, have shown that HPDs lead to significant errors in sound source localization, including large errors in source elevation perception and disorienting front-back confusions. Degradation of performance relative to open-ear listening arises due to peripheral disruptions of monaural and binaural acoustic cues for sound localization; for higher-attenuation devices, reduced audibility can also limit access to these cues, even if cues are relatively intact. A recent multi-site effort by our group leveraged manikin-based acoustic measurements of HPD-induced signal distortions to predict human localization performance during HPD use. Manikin-based acoustic metrics were positively correlated with behavioral performance across a large population of human listeners (n ≥ 120), enabling discrimination of localization impacts across HPDs, but significant individual variability was evident. Here we consider individual factors that may contribute to variability in HPD localization impact across wearers, including audiometric factors and auricular/acoustic factors. Correlational analyses of individualized predictors with localization performance provide new insight on factors that may differentially constrain – or facilitate – sound localization during HPD use.
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4_suppleme) , A237
Open AccessAccounting for individual differences in the effects of hearing protectors on sound source localization
Modern hearing protection devices (HPDs) mitigate the risk of noise-induced hearing loss when used as intended, but negative auditory perceptual side-effects continue to limit usability in critical settings. Dozens of studies, including previous studies by our group, have shown that HPDs lead to significant errors in sound source localization, including large errors in source elevation perception and disorienting front-back confusions. Degradation of performance relative to open-ear listening arises due to peripheral disruptions of monaural and binaural acoustic cues for sound localization; for higher-attenuation devices, reduced audibility can also limit access to these cues, even if cues are relatively intact. A recent multi-site effort by our group leveraged manikin-based acoustic measurements of HPD-induced signal distortions to predict human localization performance during HPD use. Manikin-based acoustic metrics were positively correlated with behavioral performance across a large population of human listeners (n ≥ 120), enabling discrimination of localization impacts across HPDs, but significant individual variability was evident. Here we consider individual factors that may contribute to variability in HPD localization impact across wearers, including audiometric factors and auricular/acoustic factors. Correlational analyses of individualized predictors with localization performance provide new insight on factors that may differentially constrain – or facilitate – sound localization during HPD use.
- Open Access
- 5 April 2023
- Published by Elsevier in Hearing Research
- Vol. 433, 108766
The continued importance of comparative auditory research to modern scientific discovery
- 5 April 2023
- Published by Elsevier in Hearing Research
- Vol. 433, 108766
Open AccessThe continued importance of comparative auditory research to modern scientific discovery
- Open Access
- 30 March 2023
- Published by Elsevier in Hearing Research
- Vol. 432, 108754
On the value of diverse organisms in auditory research: From fish to flies to humans
- 30 March 2023
- Published by Elsevier in Hearing Research
- Vol. 432, 108754
Open AccessOn the value of diverse organisms in auditory research: From fish to flies to humans
- Open Access
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A333
Quantifying impacts of hearing protection devices on sound localization in azimuth and elevation: Refinement of acoustic predictors
Modern hearing protection devices (HPDs) mitigate the risk of noise-induced hearing loss when used as intended, but negative auditory perceptual side-effects continue to limit usability in critical settings. Dozens of studies have shown that HPDs lead to significant errors in sound source localization. Several studies, including previous studies by our group, have linked such errors to distortions of the spectra of transmitted signals. Here we provide an update on a multi-site effort to develop acoustic predictors and summary metrics to quantify HPD impacts on sound source localization. At two independent study sites, human listeners localized brief broadband signals with open ears and during use of passive and active earplug and earmuff-style devices. Sources spanning 360° in azimuth and −30° to + 60° in elevation enabled measurement of two-dimensional localization error across a broad range of source locations. An initial set of parallel acoustic measurements was obtained using a standardized acoustic test fixture. Present efforts are focused on evaluating prospective advantages of (1) incorporating binaural acoustic data in the prediction of errors and (2) accounting for individual HPD-impacted acoustic variability. The long-term goal of this work is to support application-specific selection of existing HPDs and inform the design of new HPDs.
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A333
Open AccessQuantifying impacts of hearing protection devices on sound localization in azimuth and elevation: Refinement of acoustic predictors
Modern hearing protection devices (HPDs) mitigate the risk of noise-induced hearing loss when used as intended, but negative auditory perceptual side-effects continue to limit usability in critical settings. Dozens of studies have shown that HPDs lead to significant errors in sound source localization. Several studies, including previous studies by our group, have linked such errors to distortions of the spectra of transmitted signals. Here we provide an update on a multi-site effort to develop acoustic predictors and summary metrics to quantify HPD impacts on sound source localization. At two independent study sites, human listeners localized brief broadband signals with open ears and during use of passive and active earplug and earmuff-style devices. Sources spanning 360° in azimuth and −30° to + 60° in elevation enabled measurement of two-dimensional localization error across a broad range of source locations. An initial set of parallel acoustic measurements was obtained using a standardized acoustic test fixture. Present efforts are focused on evaluating prospective advantages of (1) incorporating binaural acoustic data in the prediction of errors and (2) accounting for individual HPD-impacted acoustic variability. The long-term goal of this work is to support application-specific selection of existing HPDs and inform the design of new HPDs.
- Open Access
- 1 March 2023
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 3 (3) , 034403
Wave interference at the contralateral ear helps explain non-monotonic envelope interaural time differences as a function of azimuth
Interaural time differences (ITDs), an important acoustic cue for perceptual sound-source localization, are conventionally modeled as monotonic functions of azimuth. However, recent literature and publicly available databases from binaural manikins demonstrated ITDs conveyed by the envelopes (ENV-ITDs) of high-frequency (≥2 kHz) signals that were non-monotonic functions of azimuth. This study demonstrates using a simple, time-dependent geometric model of an elliptic head that the back-traveling (longer) sound path around the head, delayed and added to the conventionally treated front-traveling path, can account for non-monotonic ENV-ITDs. These findings have implications for spatial-hearing models in acoustic and electric (cochlear-implant) hearing.
- 1 March 2023
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 3 (3) , 034403
Open AccessWave interference at the contralateral ear helps explain non-monotonic envelope interaural time differences as a function of azimuth
Interaural time differences (ITDs), an important acoustic cue for perceptual sound-source localization, are conventionally modeled as monotonic functions of azimuth. However, recent literature and publicly available databases from binaural manikins demonstrated ITDs conveyed by the envelopes (ENV-ITDs) of high-frequency (≥2 kHz) signals that were non-monotonic functions of azimuth. This study demonstrates using a simple, time-dependent geometric model of an elliptic head that the back-traveling (longer) sound path around the head, delayed and added to the conventionally treated front-traveling path, can account for non-monotonic ENV-ITDs. These findings have implications for spatial-hearing models in acoustic and electric (cochlear-implant) hearing.