Jean-Cédric Durand
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jean-Cédric Durand has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Alban Desoutter
LBN, Univ. Montpellier, Montpellier, France
2 shared publications - Michel Fages
Department of Prosthodontics University of Montpellier, Montpellier School Dentistry Montpellier Cedex France
2 shared publications - Pierre Slangen
EuroMov Digital Health in Motion, Univ Montpellier, IMT Mines Alès
2 shared publications Aurélien Ferré
Department of Prosthetic Dentistry, Faculty of Dental Medicine, University of Montpellier, France
1 shared publication- Bruno Jacquot
Preventive Department, Faculty of Odontology, Marseille University, Marseille, France
1 shared publication Camille Inquimbert
Department of Public Health, Faculty of Dental Medicine, University of Montpellier, France
1 shared publication
Latest Publications
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Microscopie confocale Raman appliquée à l’étude de l’interface zircone/céramique feldspathique.
Ce travail de thèse est une approche originale de la compréhension des mécanismes physico-chimiques s'opérant à l'interface des restaurations céramo-céramiques par la microscopie confocale Raman. Il est scindé en trois parties. La première partie expose les caractéristiques d'une chape céramique à noyau zircone (Y-TZP) recouverte d'une céramique feldspathique. Les principaux facteurs responsables de la qualité de l'interface ont été recherchés par une revue de littérature. Le principe de la microscopie confocale Raman a été décrit. La seconde partie est la mise au point des méthodes d'analyse spectrale et d'imagerie Raman, en surface et en profondeur, sur matériaux isolés et à l'interface. La répartition des phases cristallines ou amorphes a été estimée de part et d'autre de cette dernière. La composition chimique élémentaire des composants et une ligne de balayage par traversée de l'interface ont été obtenues par spectroscopie dispersive en énergie (EDS). Le troisième chapitre explore les changements chimiques et morphologiques de l'interface sous différents procédés de fabrication : avec ou sans l'utilisation d'un Liner, avec ou sans utilisation d'une cuisson de régénération de l'Y-TZP. Les images Raman ont été traitées par la fonction d'analyse K-Means Cluster. Une cartographie de la distribution des éléments chimiques a été effectuée par EDS.
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Microscopie confocale Raman appliquée à l’étude de l’interface zircone/céramique feldspathique.
Ce travail de thèse est une approche originale de la compréhension des mécanismes physico-chimiques s'opérant à l'interface des restaurations céramo-céramiques par la microscopie confocale Raman. Il est scindé en trois parties. La première partie expose les caractéristiques d'une chape céramique à noyau zircone (Y-TZP) recouverte d'une céramique feldspathique. Les principaux facteurs responsables de la qualité de l'interface ont été recherchés par une revue de littérature. Le principe de la microscopie confocale Raman a été décrit. La seconde partie est la mise au point des méthodes d'analyse spectrale et d'imagerie Raman, en surface et en profondeur, sur matériaux isolés et à l'interface. La répartition des phases cristallines ou amorphes a été estimée de part et d'autre de cette dernière. La composition chimique élémentaire des composants et une ligne de balayage par traversée de l'interface ont été obtenues par spectroscopie dispersive en énergie (EDS). Le troisième chapitre explore les changements chimiques et morphologiques de l'interface sous différents procédés de fabrication : avec ou sans l'utilisation d'un Liner, avec ou sans utilisation d'une cuisson de régénération de l'Y-TZP. Les images Raman ont été traitées par la fonction d'analyse K-Means Cluster. Une cartographie de la distribution des éléments chimiques a été effectuée par EDS.
- Open Access
- 8 February 2025
- Published by Elsevier in Archives of Oral Biology
- Vol. 173, 106189
Raman confocal microscopy atlas of human tooth
- 8 February 2025
- Published by Elsevier in Archives of Oral Biology
- Vol. 173, 106189
Open AccessRaman confocal microscopy atlas of human tooth
- 20 December 2022
- Published by Wiley in European Journal of Dental Education
- Vol. 27 (4) , 888-897
Study of the use in autonomy of intraoral scanning systems to optimise dental students' performances in fixed prosthodontics practical learning in second year
Aim: The purpose of this study was to evaluate if the use of intraoral scanner analysis could help students to optimise their performance and their self‐assessment abilities in prosthetic preparation without the teacher's assistance in the preclinical course.Materials and Methods: Ninety‐five second‐year dental students were randomly divided into three groups: Control group (C), CeRec group (CR) and PrepCheck group (PC). Group C only use silicon keys to control the preparation thickness. The students in Group CR analysed their work with Cerec™ software. The Group PC use a pedagogic software (PrepCheck™) which allowed comparison with the “master” preparation. They used control tools preparations for three consecutive training sessions. Then a final assessment session without control tool to evaluate their performance was organised. All preparations were objectively evaluated thanks to stl. analysis software (Geomagic® Control X). Each preparation was compared with the master preparation by defining tolerance ranges. An objective overall score out of 20 was assigned to each preparation according to their degree of correspondence. In addition, a questionnaire was performed to analyse the students' perceptions regarding the use of intraoral camera.Results: During the assessment session, no significant difference was revealed between the different groups with respect to the students' performance. The comparative analysis between the self‐assessment scores and the objective scores using Geomagic® software showed that digital control tools did not help the student to improve their self‐assessment abilities without the teacher's assistance.Conclusions: The intraoral cameras and specific pedagogic software in autonomy could not improve students' performance for teeth preparation and self‐assessment abilities in second year. These digital tools facilitate objective feedback on preparation defects, but constructive criticism needs human reflection. The teacher's opinions and advice remain essential to develop their students' performance and self‐assessment skills. The use of digital tools must be integrated in dentistry course to develop the interpret of the results and optimise feedback.
- 20 December 2022
- Published by Wiley in European Journal of Dental Education
- Vol. 27 (4) , 888-897
Study of the use in autonomy of intraoral scanning systems to optimise dental students' performances in fixed prosthodontics practical learning in second year
Aim: The purpose of this study was to evaluate if the use of intraoral scanner analysis could help students to optimise their performance and their self‐assessment abilities in prosthetic preparation without the teacher's assistance in the preclinical course.Materials and Methods: Ninety‐five second‐year dental students were randomly divided into three groups: Control group (C), CeRec group (CR) and PrepCheck group (PC). Group C only use silicon keys to control the preparation thickness. The students in Group CR analysed their work with Cerec™ software. The Group PC use a pedagogic software (PrepCheck™) which allowed comparison with the “master” preparation. They used control tools preparations for three consecutive training sessions. Then a final assessment session without control tool to evaluate their performance was organised. All preparations were objectively evaluated thanks to stl. analysis software (Geomagic® Control X). Each preparation was compared with the master preparation by defining tolerance ranges. An objective overall score out of 20 was assigned to each preparation according to their degree of correspondence. In addition, a questionnaire was performed to analyse the students' perceptions regarding the use of intraoral camera.Results: During the assessment session, no significant difference was revealed between the different groups with respect to the students' performance. The comparative analysis between the self‐assessment scores and the objective scores using Geomagic® software showed that digital control tools did not help the student to improve their self‐assessment abilities without the teacher's assistance.Conclusions: The intraoral cameras and specific pedagogic software in autonomy could not improve students' performance for teeth preparation and self‐assessment abilities in second year. These digital tools facilitate objective feedback on preparation defects, but constructive criticism needs human reflection. The teacher's opinions and advice remain essential to develop their students' performance and self‐assessment skills. The use of digital tools must be integrated in dentistry course to develop the interpret of the results and optimise feedback.
- Open Access
- 7 September 2021
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 15 (04) , 612-617
Effect of a Procedural Video on the Practical Fixed Prosthodontic Performance and Stress among Preclinical Dental Students
Objective The purpose of this article was to analyze the effect of an instructional video on practical tutorial and to ascertain whether an instructional video improves students’ performance on practical performance and reduces the stress associated with learning. Materials and Methods A randomized controlled trial was conducted on a group of 78 first-year students. A pretest was conducted by administering questionnaires to evaluate the interest in the use of videos as well as the level of stress. Students were randomly assigned into two groups: control and test. Students assigned to the control group received conventional teaching, while the experimental group received both conventional teaching and watched a video. Thereafter, a satisfaction questionnaire was distributed to each of the groups, and they were awarded a grade. Results A total of 98.7% of students wished to learn fixed prosthodontics through instructional videos, as they believed that the videos could reduce their worry and stress levels. At the end of the first tutorial, the total grade was significantly lower for the test group (p = 0.003). However, the subjective value of stress was significantly lower in the test group (p = 0.0007) as well as the subjective value of tutorial difficulty (p = 0.0004). Students felt that they better understood the objectives of the tutorial “thanks to the video” (p = 0.0001). Conclusion This study did not reveal any improvement in terms of performance when an instructional video was used for tutorials in comparison with the conventional teaching method. However, the results show a reduction in the level of stress.
- 7 September 2021
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 15 (04) , 612-617
Open AccessEffect of a Procedural Video on the Practical Fixed Prosthodontic Performance and Stress among Preclinical Dental Students
Objective The purpose of this article was to analyze the effect of an instructional video on practical tutorial and to ascertain whether an instructional video improves students’ performance on practical performance and reduces the stress associated with learning. Materials and Methods A randomized controlled trial was conducted on a group of 78 first-year students. A pretest was conducted by administering questionnaires to evaluate the interest in the use of videos as well as the level of stress. Students were randomly assigned into two groups: control and test. Students assigned to the control group received conventional teaching, while the experimental group received both conventional teaching and watched a video. Thereafter, a satisfaction questionnaire was distributed to each of the groups, and they were awarded a grade. Results A total of 98.7% of students wished to learn fixed prosthodontics through instructional videos, as they believed that the videos could reduce their worry and stress levels. At the end of the first tutorial, the total grade was significantly lower for the test group (p = 0.003). However, the subjective value of stress was significantly lower in the test group (p = 0.0007) as well as the subjective value of tutorial difficulty (p = 0.0004). Students felt that they better understood the objectives of the tutorial “thanks to the video” (p = 0.0001). Conclusion This study did not reveal any improvement in terms of performance when an instructional video was used for tutorials in comparison with the conventional teaching method. However, the results show a reduction in the level of stress.
- 1 June 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 118, 104436
Behavior of CAD/CAM ceramic veneers under stress: A 3D holographic study
- 1 June 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 118, 104436
Behavior of CAD/CAM ceramic veneers under stress: A 3D holographic study
- Open Access
- 1 January 2021
- Published by Wiley in Case Reports in Dentistry
- Vol. 2021 (1)
Using the “One Shot” Concept for Immediate Loading Implant Protocol in Edentulous Patient Rehabilitation with a Fixed Prosthesis: A 6‐Year Follow‐Up
Immediate‐loaded implants with a fixed prosthesis are a viable option for the restoration of edentulous ridges. Several procedures now allow for the fabrication of immediate‐loading provisional and definitive prostheses. However, this complex treatment is not accessible to all patients with budget restrictions. By using a unique master model with a single titanium framework prosthesis can simplify and shorten the treatment, as well as reduce costs. After surgical placement of implant fixtures, an interim prosthesis was fabricated using a laser‐welded definitive titanium framework. The prosthesis was fitted intraorally following the immediate loading protocols. The master cast model used to fabricate interim prosthesis was conserved and subsequently used in modifying the final prosthesis. After the healing process and complete soft tissue stability, an impression was made to register the clearance between the gingiva and resin. The light silicone material was directly injected under the prosthesis screwed in the mouth. In the master cast model, the stone was eliminated between the implants and a new plaster was poured to modify the crest profile with the posthealing new shape. With this modified model, it is possible to rehabilitate the denture to the new gingival anatomy in 3 to 4 hours and, if necessary, the tooth rearrangement. This “one shot” concept combines the single definitive titanium welded framework and limited laboratory work with a unique master model thereby decreasing the cost and the time of treatment.
- 1 January 2021
- Published by Wiley in Case Reports in Dentistry
- Vol. 2021 (1)
Open AccessUsing the “One Shot” Concept for Immediate Loading Implant Protocol in Edentulous Patient Rehabilitation with a Fixed Prosthesis: A 6‐Year Follow‐Up
Immediate‐loaded implants with a fixed prosthesis are a viable option for the restoration of edentulous ridges. Several procedures now allow for the fabrication of immediate‐loading provisional and definitive prostheses. However, this complex treatment is not accessible to all patients with budget restrictions. By using a unique master model with a single titanium framework prosthesis can simplify and shorten the treatment, as well as reduce costs. After surgical placement of implant fixtures, an interim prosthesis was fabricated using a laser‐welded definitive titanium framework. The prosthesis was fitted intraorally following the immediate loading protocols. The master cast model used to fabricate interim prosthesis was conserved and subsequently used in modifying the final prosthesis. After the healing process and complete soft tissue stability, an impression was made to register the clearance between the gingiva and resin. The light silicone material was directly injected under the prosthesis screwed in the mouth. In the master cast model, the stone was eliminated between the implants and a new plaster was poured to modify the crest profile with the posthealing new shape. With this modified model, it is possible to rehabilitate the denture to the new gingival anatomy in 3 to 4 hours and, if necessary, the tooth rearrangement. This “one shot” concept combines the single definitive titanium welded framework and limited laboratory work with a unique master model thereby decreasing the cost and the time of treatment.
- 19 August 2017
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 28 (10) , 145
Glass Ceramic CAD/CAM crowns and severely altered posterior teeth: a three levels study
For many practitioners, longevity of full glass ceramic crowns in the posterior area, molars and premolars, remains a real challenge. The purpose of this article is to identify and evaluate the parameters that can significantly influence their resistance when preparing a tooth. The analysis proposed in this article relies on interrelated studies conducted at three levels: in vitro (mechanical tests), in silico (finite elements simulations) and in vivo (clinical survival rates). The in vitro and the in silico studies proved that an appropriate variation of the geometric design of the preparations enables to increase up to 80% the mechanical strength of ceramic reconstructions. The in vivo clinical study of CAD/CAM full ceramic crowns was performed in accordance with the principles stated within the in vitro and the in silico studies and provided a 98.97% success rate over a 6 years period. The variations of geometric design parameters for dental preparation allows for reconstructions with a mechanical breaking up to 80% higher than that of a non-appropriate combination. These results are confirmed in clinical practice.
- 19 August 2017
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 28 (10) , 145
Glass Ceramic CAD/CAM crowns and severely altered posterior teeth: a three levels study
For many practitioners, longevity of full glass ceramic crowns in the posterior area, molars and premolars, remains a real challenge. The purpose of this article is to identify and evaluate the parameters that can significantly influence their resistance when preparing a tooth. The analysis proposed in this article relies on interrelated studies conducted at three levels: in vitro (mechanical tests), in silico (finite elements simulations) and in vivo (clinical survival rates). The in vitro and the in silico studies proved that an appropriate variation of the geometric design of the preparations enables to increase up to 80% the mechanical strength of ceramic reconstructions. The in vivo clinical study of CAD/CAM full ceramic crowns was performed in accordance with the principles stated within the in vitro and the in silico studies and provided a 98.97% success rate over a 6 years period. The variations of geometric design parameters for dental preparation allows for reconstructions with a mechanical breaking up to 80% higher than that of a non-appropriate combination. These results are confirmed in clinical practice.
- Top Cited PapersOpen Access
- 1 January 2017
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 9 (6) , 486-495
Dental biomaterials for chairside CAD/CAM: State of the art
Lambert H, et al. J Adv Prosthodont. 2017 Dec;9(6):486-495. https://doi.org/10.4047/jap.2017.9.6.486
- 1 January 2017
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 9 (6) , 486-495
Top Cited PapersOpen AccessDental biomaterials for chairside CAD/CAM: State of the art
Lambert H, et al. J Adv Prosthodont. 2017 Dec;9(6):486-495. https://doi.org/10.4047/jap.2017.9.6.486