HLHuakun Liu

Huakun Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huakun Liu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    An Oscillatory Stability Criterion Based on the Unified $dq$ -Frame Impedance Network Model for Power Systems With High-Penetration Renewables

    by Huakun Liu, Xiaorong Xie, Wei Liu

    Recent years have witnessed emerging oscillatory stability issues in power systems with high-penetration renewables. These issues are generally caused by the dynamic interaction between the AC/DC grid and power electronic converters used for the integration of renewables. Some previous studies have explored the issues with simplified system models containing only a few converters and idealized networks. However, the interactions between many converters and traditional generators/HVDCs have not been fully considered. To fill this gap, this paper first presents the concept of a unified dq frame impedance network model (INM), with which different converters as well as traditional generators/HVDCs can be incorporated to form an integrated s-domain model of a practical system. As the INM is aggregated into a lumped impedance matrix, a new criterion is then proposed to quantify the oscillatory stability, just by analyzing the frequency characteristics of the determinant of the matrix. Finally, the modeling method and the stability criterion are applied to a real-world system with a very high share of renewables and a realistic risk of oscillatory instability. Their effectiveness has been validated by both field measurements and electromagnetic transient simulations.


  • Stability Analysis of SSR in Multiple Wind Farms Connected to Series-Compensated Systems Using Impedance Network Model

    by Huakun Liu, Xiaorong Xie, Xiaodan Gao, Hui Liu, Yunhong Li

    Recently, an emerging subsynchronous resonance (SSR) issue was observed in series-compensated systems com-prising multiple wind farms. However, only simplified single- machine-infinite-bus system models were adopted to investigate the characteristics of this issue in the previous work. As a result, it is unable to reflect the impact on SSR from some critical factors, such as the network topology, the spatial distribution of wind farms, the diversity of wind turbine generators, and the distrib-uted wind speed. To fill in this gap, this paper proposes an im-pedance network model (INM) based SSR stability analysis method. The impedance models of each wind farm and transmis-sion line are established, and then interconnected according to system topology to form the whole INM. Such INM is further aggregated into lumped impedance. By analyzing the imped-ance-frequency features of the latter, a new stability criterion is developed to quantify the stability of SSR. The application of the criterion is demonstrated on a practical power system containing multiple wind farms. Both field measurements and time-domain simulations have been presented to validate its effectiveness and accuracy. The proposed method is of great potential in analyzing the SSR issue for very large-scale wind power systems.


  • Top Cited Papers

    Subsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks

    by Huakun Liu, Xiaorong Xie, Jingbo He, Tao Xu, Zhao Yu, Chao Wang, Chuanyu Zhang

    Recently, sustained power oscillation at subsynchronous frequency was captured in direct-drive permanent magnetic synchronous generator (PMSG) based wind farms in Xinjiang Uygur Autonomous Region, China. This new type of subsynchronous interaction (SSI) detected in practical systems has never been reported and analyzed before. Therefore, its mechanism and characteristics are not yet clearly clarified. In this paper, a simplified but representative system model with multiple PMSGs interfaced with AC networks is established first based on the actual system and the PMSG model provided by the manufacturer. Then, small-signal eigenanalysis, time-domain simulation, and impedance model analysis are carried out to investigate the interactive dynamics between them. The results show that such interaction between direct-drive PMSG wind farms and weak ac grids characterized by low short-circuit ratio would cause negative-resistance effect for the SSI mode, leading to unstable oscillation. In such cases, the controller of PMSG would saturate soon, resulting in sustained power oscillation in the system. If unfortunately the oscillation frequency matches the torsional mode of any nearby turbogenerator, severe torsional vibration would be excited on the shaft of the latter. The analysis results are finally validated with field measurements of an actual SSI event. To address the problem, a supplementary subsynchronous damping control loop is attached to the controllers of PMSGs to reshape the impedance and thus to stabilize the SSI.