Abdollah Yari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Abdollah Yari has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
Mojtaba Shamsipur
8 shared publicationsAzim Shams
Lorestan Univ, Dept Chem, Khorramabad 6813717133, Iran
6 shared publications- Vito Lippolis
Dipartimento di Scienze Chimiche e Geologiche, Università degli Studi di Cagliari, S.S. 554 bivio Sestu, 09042 Monserrato (Cagliari), Italy
6 shared publications Alessandra Garau
Dipartimento di Chimica Inorganica ed Analitica, Universitá degli Studi di Cagliari, S.S. 554 bivio per Sestu, 09042 Monserrato, Cagliari, Italy
5 shared publications- Mohsen Adeli
Faculty of Science, Department of Chemistry, Lorestan University, Khorramabad, Iran
5 shared publications Fatemeh Papi
3 shared publications
Latest Publications
- 1 October 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (45) , 7710-7722
Removal and measurement of trace amounts of rhodamine B in aqueous samples based on the synthesis of a nanosorbent composed of Fe3O4 nanoparticles modified with SiO2 and polydopamine by magnetic solid phase extraction
Rhodamine B (RDB) dye is generally toxic and causes problems such as carcinogenic activities, neurological disorders, and respiratory tract irritations. However, some individuals still illegally use RDB as a food additive. Therefore, a simple and accurate method is needed to determine RDB in real samples such as food or cosmetic products. In this study, the magnetic solid phase extraction (MSPE) method was used to measure very low amounts of RDB dye in water samples. The advantages of this method include simplicity, good repeatability, high preconcentration factor, higher extraction efficiency, low organic solvent volume requirement, rapid separation, low cost, high sensitivity, and interference removal compared to other methods. Within this approach, iron oxide nanoparticles were synthesised, followed by the application of tetra ethoxy silane (TEOS) and polydopamine (PDA) coatings on the nanoparticle surface, resulting in the creation of the Fe3O4@SiO2@PDA nano-sorbent. This nano-sorbent was then utilized as the magnetic solid phase in MSPE. The characteristics of the synthesized compounds were investigated by various methods such as infrared Fourier transform spectroscopy (FT-IR), field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDX), X-ray diffraction spectroscopy (XRD), and vibrating sample magnetometry (VSM). Response surface methodology (RSM) and Box–Behnken (BB) design were used to optimize the variables affecting the adsorption process and achieved high recovery percentages. Under optimal experimental conditions, the detection limit and quantification limit of the method were found to be 0.73 and 2.42 μg L−1 for RDB, respectively, with RSDs of ±0.32% and ±0.67%. Furthermore, the linear concentration range of the proposed method for solid phase extraction of RDB was determined to be 10.0–900.0 μg L−1. Moreover, the recovery rates for tap water, lake water, and well water samples ranged from 96.9% to 98.6%.
- 1 October 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (45) , 7710-7722
Removal and measurement of trace amounts of rhodamine B in aqueous samples based on the synthesis of a nanosorbent composed of Fe3O4 nanoparticles modified with SiO2 and polydopamine by magnetic solid phase extraction
Rhodamine B (RDB) dye is generally toxic and causes problems such as carcinogenic activities, neurological disorders, and respiratory tract irritations. However, some individuals still illegally use RDB as a food additive. Therefore, a simple and accurate method is needed to determine RDB in real samples such as food or cosmetic products. In this study, the magnetic solid phase extraction (MSPE) method was used to measure very low amounts of RDB dye in water samples. The advantages of this method include simplicity, good repeatability, high preconcentration factor, higher extraction efficiency, low organic solvent volume requirement, rapid separation, low cost, high sensitivity, and interference removal compared to other methods. Within this approach, iron oxide nanoparticles were synthesised, followed by the application of tetra ethoxy silane (TEOS) and polydopamine (PDA) coatings on the nanoparticle surface, resulting in the creation of the Fe3O4@SiO2@PDA nano-sorbent. This nano-sorbent was then utilized as the magnetic solid phase in MSPE. The characteristics of the synthesized compounds were investigated by various methods such as infrared Fourier transform spectroscopy (FT-IR), field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDX), X-ray diffraction spectroscopy (XRD), and vibrating sample magnetometry (VSM). Response surface methodology (RSM) and Box–Behnken (BB) design were used to optimize the variables affecting the adsorption process and achieved high recovery percentages. Under optimal experimental conditions, the detection limit and quantification limit of the method were found to be 0.73 and 2.42 μg L−1 for RDB, respectively, with RSDs of ±0.32% and ±0.67%. Furthermore, the linear concentration range of the proposed method for solid phase extraction of RDB was determined to be 10.0–900.0 μg L−1. Moreover, the recovery rates for tap water, lake water, and well water samples ranged from 96.9% to 98.6%.
- 5 December 2023
- Published by Springer Nature in Journal of Analysis and Testing
- Vol. 7 (4) , 416-424
A New Highly Sensitive Optical Sensor Based on Congo-Red for the Determination of Thorium (IV) in Aqueous Solution
- 5 December 2023
- Published by Springer Nature in Journal of Analysis and Testing
- Vol. 7 (4) , 416-424
A New Highly Sensitive Optical Sensor Based on Congo-Red for the Determination of Thorium (IV) in Aqueous Solution
- 29 November 2023
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 5 (12) , 7087-7097
Nanocomposite of Palladium Nanoparticles Anchored on Boron Nitride Nanosheets as a Sensor for Liver Treatment Drug Silymarin
- 29 November 2023
- Published by American Chemical Society (ACS) in ACS Applied Electronic Materials
- Vol. 5 (12) , 7087-7097
Nanocomposite of Palladium Nanoparticles Anchored on Boron Nitride Nanosheets as a Sensor for Liver Treatment Drug Silymarin
- 11 August 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (33) , 4134-4141
Electrochemical biosensing based on folic acid-triazine-grafted reduced graphene oxide: a highly selective breast cancer cell sensor
Based on the results of this research, a new electrochemical sensor has been developed to detect human breast cancer cells (MCF-7). A folic acid (FA)-functionalized triazine-grafted reduced graphene oxide (RGOTrz) was used as the modifier of a glassy carbon electrode (GCE) for application as the sensing element. The composition of the resulting FA-RGOTrz/GCE was investigated using XRD (X-ray diffraction), FT-IR (Fourier-transform infrared) spectroscopy, SEM (scanning electron microscopy) and UV-vis spectroscopy studies. CV (cyclic voltammetry) and EIS (electrochemical impedance spectroscopy) techniques were also used to characterize the electrochemical proficiency of the new electrode. Further, MCF-7 cancer cells were examined in solutions of phosphate buffer and [Fe(CN)6]3−/4− as a suitable supporting electrolyte and a useful probe, respectively. The FA-RGOTrz/GCE provides a suitable substrate to reversible redox reactions and provides good electrochemical signals after binding to cancer cells. DPV (differential pulse voltammetry) results indicated that the binding of folate receptor (FR) in the MCF-7 cell to the RGOTrz-modified electrode, in the presence of [Fe(CN)6]3−/4−, reduced folic acid, diminished electron transfer and collapsed the current signal. During the measured flow, a detection limit of 50 human breast cancer cells per milliliter was obtained. The FA-RGOTrz/GCE, with its unique structural design, significantly increases the electron transfer and electrochemical activity towards the detection of MCF-7 cells. This FA-RGOTrz/GCE sensor, due to its special structure, shows high sensitivity to FR in MCF-7 cells and excellent, reliable and satisfactory performance and a great promise for use in industries and medical field.
- 11 August 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (33) , 4134-4141
Electrochemical biosensing based on folic acid-triazine-grafted reduced graphene oxide: a highly selective breast cancer cell sensor
Based on the results of this research, a new electrochemical sensor has been developed to detect human breast cancer cells (MCF-7). A folic acid (FA)-functionalized triazine-grafted reduced graphene oxide (RGOTrz) was used as the modifier of a glassy carbon electrode (GCE) for application as the sensing element. The composition of the resulting FA-RGOTrz/GCE was investigated using XRD (X-ray diffraction), FT-IR (Fourier-transform infrared) spectroscopy, SEM (scanning electron microscopy) and UV-vis spectroscopy studies. CV (cyclic voltammetry) and EIS (electrochemical impedance spectroscopy) techniques were also used to characterize the electrochemical proficiency of the new electrode. Further, MCF-7 cancer cells were examined in solutions of phosphate buffer and [Fe(CN)6]3−/4− as a suitable supporting electrolyte and a useful probe, respectively. The FA-RGOTrz/GCE provides a suitable substrate to reversible redox reactions and provides good electrochemical signals after binding to cancer cells. DPV (differential pulse voltammetry) results indicated that the binding of folate receptor (FR) in the MCF-7 cell to the RGOTrz-modified electrode, in the presence of [Fe(CN)6]3−/4−, reduced folic acid, diminished electron transfer and collapsed the current signal. During the measured flow, a detection limit of 50 human breast cancer cells per milliliter was obtained. The FA-RGOTrz/GCE, with its unique structural design, significantly increases the electron transfer and electrochemical activity towards the detection of MCF-7 cells. This FA-RGOTrz/GCE sensor, due to its special structure, shows high sensitivity to FR in MCF-7 cells and excellent, reliable and satisfactory performance and a great promise for use in industries and medical field.
- 19 April 2023
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (8) , 1939-1948
Fabrication of a highly sensitive new ANT/MoS2/Fe3O4/GCE nanocomposite electrochemical sensor for herbicide Paraquat residual in environmental water resources
- 19 April 2023
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (8) , 1939-1948
Fabrication of a highly sensitive new ANT/MoS2/Fe3O4/GCE nanocomposite electrochemical sensor for herbicide Paraquat residual in environmental water resources