Frieder Koch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Frieder Koch has a total of 187 co-authors. Here are the top co-authors by number of shared publications:
- Danays Kunka
Karlsruhe Institute of Technology
9 shared publications - Pascal Meyer
Karlsruhe Institute of Technology, Institute of Microstructure Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
9 shared publications Jürgen Mohr
Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
6 shared publicationsFranz Pfeiffer
Chair of Biomedical Physics & Institute of Medical Engineering, Technical University of Munich, 85748, Garching, Germany
4 shared publicationsJan Meiser
Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
4 shared publicationsAndre Yaroshenko
Chair of Biomedical Physics & Institute of Medical Engineering, Technical University of Munich, 85748, Garching, Germany
3 shared publications
Latest Publications
- Open Access
- 14 September 2026
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 713, A156
Heavy-ion irradiation of interstellar carbonaceous and siliceous composite dust analogs
Context . Interstellar dust made of siliceous and carbonaceous grains is exposed to cosmic ray ions in the diffuse and dense medium. This highly energetic interaction not only affects the morphology of such systems, but also plays a role in altering the surface and bulk chemistry. These two effects are both key points in understanding the evolution of the interstellar medium matter cycle throughout which we observe variations in the dust’s spectroscopic signatures. Aims . The goal is to better understand, at the nanoscale, the effect of impinging ions on the physical and chemical structure of irradiated dust grains. Methods . To experimentally investigate this phenomenon, two types of dust analogs were produced in the laboratory: an organic fraction made of hydrogenated amorphous carbon (a-C:H) samples and polystyrene (PS) samples to which an inorganic component (SiO 2 ) was added. Their irradiation was then conducted at the GSI UNILAC accelerator using a 945.4 MeV 197 Au 25+ beam, simulating the irradiation by Galactic cosmic rays. In situ infrared spectra were acquired during irradiation to follow the sample’s chemical evolution, and ex situ transmission electron microscopy (TEM) and energy-dispersive X-ray (EDX) micrographs were recorded to investigate the post-irradiation nanostructure and composition. Results . The radiolysis cross sections of the different dust grain analogs were determined. The TEM and EDX images allowed us to constrain the size of tracks produced by the heavy ions in these matrices and visualize the irradiation effects on the morphology of the different samples. The results are extrapolated in an astrophysical context to quantify the tracks produced in interstellar dust under Galactic cosmic ray irradiation.
- 14 September 2026
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 713, A156
Open AccessHeavy-ion irradiation of interstellar carbonaceous and siliceous composite dust analogs
Context . Interstellar dust made of siliceous and carbonaceous grains is exposed to cosmic ray ions in the diffuse and dense medium. This highly energetic interaction not only affects the morphology of such systems, but also plays a role in altering the surface and bulk chemistry. These two effects are both key points in understanding the evolution of the interstellar medium matter cycle throughout which we observe variations in the dust’s spectroscopic signatures. Aims . The goal is to better understand, at the nanoscale, the effect of impinging ions on the physical and chemical structure of irradiated dust grains. Methods . To experimentally investigate this phenomenon, two types of dust analogs were produced in the laboratory: an organic fraction made of hydrogenated amorphous carbon (a-C:H) samples and polystyrene (PS) samples to which an inorganic component (SiO 2 ) was added. Their irradiation was then conducted at the GSI UNILAC accelerator using a 945.4 MeV 197 Au 25+ beam, simulating the irradiation by Galactic cosmic rays. In situ infrared spectra were acquired during irradiation to follow the sample’s chemical evolution, and ex situ transmission electron microscopy (TEM) and energy-dispersive X-ray (EDX) micrographs were recorded to investigate the post-irradiation nanostructure and composition. Results . The radiolysis cross sections of the different dust grain analogs were determined. The TEM and EDX images allowed us to constrain the size of tracks produced by the heavy ions in these matrices and visualize the irradiation effects on the morphology of the different samples. The results are extrapolated in an astrophysical context to quantify the tracks produced in interstellar dust under Galactic cosmic ray irradiation.
- Open Access
- 12 June 2026
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 17 (1) , 769-780
Substrate-dependent pore formation in molybdenum disulfide monolayers under ion irradiation
Ion irradiation is a versatile tool for nanostructuring surfaces, yet the roles of energy deposition and dissipation at the surface and in ultrathin materials remain poorly understood. In this study, we investigate nanopore formation in monolayer MoS 2 on different substrates under irradiation of highly charged ions (HCIs) and swift heavy ions (SHIs) – two types of ions that, despite having vastly different kinetic energies, both interact primarily with the electronic system of the target. Using scanning transmission electron microscopy, we quantify pore radii and pore formation efficiencies for suspended MoS 2 , MoS 2 on SiO 2 , bilayer MoS 2 , and MoS 2 on gold. Both pore size and pore formation efficiency exhibit a pronounced dependence on the type of substrate. Pores are largest and most frequent in MoS 2 on SiO 2 , while the gold substrate massively quenches pore formation. The observed pore dimensions under both HCI and SHI irradiation conclusively demonstrate the central role of substrate and interface-dependent electronic dissipation pathways regarding damage under these types of ion irradiation.
- 12 June 2026
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 17 (1) , 769-780
Open AccessSubstrate-dependent pore formation in molybdenum disulfide monolayers under ion irradiation
Ion irradiation is a versatile tool for nanostructuring surfaces, yet the roles of energy deposition and dissipation at the surface and in ultrathin materials remain poorly understood. In this study, we investigate nanopore formation in monolayer MoS 2 on different substrates under irradiation of highly charged ions (HCIs) and swift heavy ions (SHIs) – two types of ions that, despite having vastly different kinetic energies, both interact primarily with the electronic system of the target. Using scanning transmission electron microscopy, we quantify pore radii and pore formation efficiencies for suspended MoS 2 , MoS 2 on SiO 2 , bilayer MoS 2 , and MoS 2 on gold. Both pore size and pore formation efficiency exhibit a pronounced dependence on the type of substrate. Pores are largest and most frequent in MoS 2 on SiO 2 , while the gold substrate massively quenches pore formation. The observed pore dimensions under both HCI and SHI irradiation conclusively demonstrate the central role of substrate and interface-dependent electronic dissipation pathways regarding damage under these types of ion irradiation.
- Open Access
Current Status of Hard X-Ray Nano-Tomography on the Transmission Microscope at the ANATOMIX Beamline
The transmission X-ray microscope (TXM) on the Anatomix beamline welcomed its first nano-tomography users in 2019. The instrument is based on diffractive optics and works in the range of energies from 7 keV to 21 keV. A spatial resolution in 3D volumes of better than 100 nm can be achieved. The design allows imaging samples in air, and local tomography as well as off-axis tomography scans are possible. Scans below and above K-edges can be made to access elemental distribution. The TXM serves materials science and the bio-medical field.
Open AccessCurrent Status of Hard X-Ray Nano-Tomography on the Transmission Microscope at the ANATOMIX Beamline
The transmission X-ray microscope (TXM) on the Anatomix beamline welcomed its first nano-tomography users in 2019. The instrument is based on diffractive optics and works in the range of energies from 7 keV to 21 keV. A spatial resolution in 3D volumes of better than 100 nm can be achieved. The design allows imaging samples in air, and local tomography as well as off-axis tomography scans are possible. Scans below and above K-edges can be made to access elemental distribution. The TXM serves materials science and the bio-medical field.
- 26 April 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 118 (17) , 171102
Upscaling of multi-beam x-ray ptychography for efficient x-ray microscopy with high resolution and large field of view
Nondestructive imaging with both a large field of view and a high spatial resolution is crucial to understand complex materials and processes in science and technology. X-ray ptychography can provide highest spatial resolution but is limited in the field of view by the acquisition time and coherent flux at modern x-ray sources. By multi-beam ptychography, the sample can be imaged in parallel by several spatially separated and mutually incoherent beams. We have implemented this method using 3D nanoprinted x-ray optics to create tailor-made x-ray multi-beam arrays. The use of 3D printing allows us to create focusing optics with a minimum of nonfunctional support structures. In this way, large sample areas can be efficiently scanned in parallel with up to six illuminating beams.
- 26 April 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 118 (17) , 171102
Upscaling of multi-beam x-ray ptychography for efficient x-ray microscopy with high resolution and large field of view
Nondestructive imaging with both a large field of view and a high spatial resolution is crucial to understand complex materials and processes in science and technology. X-ray ptychography can provide highest spatial resolution but is limited in the field of view by the acquisition time and coherent flux at modern x-ray sources. By multi-beam ptychography, the sample can be imaged in parallel by several spatially separated and mutually incoherent beams. We have implemented this method using 3D nanoprinted x-ray optics to create tailor-made x-ray multi-beam arrays. The use of 3D printing allows us to create focusing optics with a minimum of nonfunctional support structures. In this way, large sample areas can be efficiently scanned in parallel with up to six illuminating beams.
- 10 November 2020
- Published by Optica Publishing Group in Optica
- Vol. 7 (11) , 1602-1608
Soft x-ray microscopy with 7 nm resolution
The availability of intense soft x-ray beams with tunable energy and polarization has pushed the development of highly sensitive, element-specific, and noninvasive microscopy techniques to investigate condensed matter with high spatial and temporal resolution. The short wavelengths of soft x-rays promise to reach spatial resolutions in the deep single-digit nanometer regime, providing unprecedented access to magnetic phenomena at fundamental length scales. Despite considerable efforts in soft x-ray microscopy techniques, a two-dimensional resolution of 10 nm has not yet been surpassed in direct imaging. Here, we report on a significant step beyond this long-standing limit by combining newly developed soft x-ray Fresnel zone plate lenses with advanced precision in scanning control and careful optical design. With this approach, we achieve an image resolution of 7 nm. By combining this highly precise microscopy technique with the x-ray magnetic circular dichroism effect, we reveal dimensionality effects in an ensemble of interacting magnetic nanoparticles. Such effects are topical in current nanomagnetism research and highlight the opportunities of high-resolution soft x-ray microscopy in magnetism research and beyond.
- 10 November 2020
- Published by Optica Publishing Group in Optica
- Vol. 7 (11) , 1602-1608
Soft x-ray microscopy with 7 nm resolution
The availability of intense soft x-ray beams with tunable energy and polarization has pushed the development of highly sensitive, element-specific, and noninvasive microscopy techniques to investigate condensed matter with high spatial and temporal resolution. The short wavelengths of soft x-rays promise to reach spatial resolutions in the deep single-digit nanometer regime, providing unprecedented access to magnetic phenomena at fundamental length scales. Despite considerable efforts in soft x-ray microscopy techniques, a two-dimensional resolution of 10 nm has not yet been surpassed in direct imaging. Here, we report on a significant step beyond this long-standing limit by combining newly developed soft x-ray Fresnel zone plate lenses with advanced precision in scanning control and careful optical design. With this approach, we achieve an image resolution of 7 nm. By combining this highly precise microscopy technique with the x-ray magnetic circular dichroism effect, we reveal dimensionality effects in an ensemble of interacting magnetic nanoparticles. Such effects are topical in current nanomagnetism research and highlight the opportunities of high-resolution soft x-ray microscopy in magnetism research and beyond.
- Open Access
- 18 March 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (3) , 583-589
Measurement and compensation of misalignment in double-sided hard X-ray Fresnel zone plates
Double-sided Fresnel zone plates are diffractive lenses used for high-resolution hard X-ray microscopy. The double-sided structures have significantly higher aspect ratios compared with single-sided components and hence enable more efficient imaging. The zone plates discussed in this paper are fabricated on each side of a thin support membrane, and the alignment of the zone plates with respect to each other is critical. Here, a simple and reliable way of quantifying misalignments by recording efficiency maps and measuring the absolute diffraction efficiency of the zone plates as a function of tilting angle in two directions is presented. The measurements are performed in a setup based on a tungsten-anode microfocus X-ray tube, providing an X-ray energy of 8.4 keV through differential measurements with a Cu and an Ni filter. This study investigates the sources of the misalignments and concludes that they can be avoided by decreasing the structure heights on both sides of the membrane and by pre-programming size differences between the front- and back-side zone plates.
- 18 March 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (3) , 583-589
Open AccessMeasurement and compensation of misalignment in double-sided hard X-ray Fresnel zone plates
Double-sided Fresnel zone plates are diffractive lenses used for high-resolution hard X-ray microscopy. The double-sided structures have significantly higher aspect ratios compared with single-sided components and hence enable more efficient imaging. The zone plates discussed in this paper are fabricated on each side of a thin support membrane, and the alignment of the zone plates with respect to each other is critical. Here, a simple and reliable way of quantifying misalignments by recording efficiency maps and measuring the absolute diffraction efficiency of the zone plates as a function of tilting angle in two directions is presented. The measurements are performed in a setup based on a tungsten-anode microfocus X-ray tube, providing an X-ray energy of 8.4 keV through differential measurements with a Cu and an Ni filter. This study investigates the sources of the misalignments and concludes that they can be avoided by decreasing the structure heights on both sides of the membrane and by pre-programming size differences between the front- and back-side zone plates.
- Open Access
- 11 March 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (6) , 8639-8650
Ptychographic characterisation of polymer compound refractive lenses manufactured by additive technology
The recent success in the development of high-precision printing techniques allows one to manufacture free-standing polymer structures of high quality. Two-photon polymerization lithography is a mask-less technique with down to 100 nm resolution that provides full geometric freedom. It has recently been applied to the nanofabrication of X-ray compound refractive lenses (CRLs). In this article we report on the characterization of two sets of CRLs of different design produced by two-photon polymerization-induced lithography.
- 11 March 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (6) , 8639-8650
Open AccessPtychographic characterisation of polymer compound refractive lenses manufactured by additive technology
The recent success in the development of high-precision printing techniques allows one to manufacture free-standing polymer structures of high quality. Two-photon polymerization lithography is a mask-less technique with down to 100 nm resolution that provides full geometric freedom. It has recently been applied to the nanofabrication of X-ray compound refractive lenses (CRLs). In this article we report on the characterization of two sets of CRLs of different design produced by two-photon polymerization-induced lithography.
- 24 January 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (3) , 574-577
Towards X-ray transient grating spectroscopy
The extension of transient grating spectroscopy to the x-ray regime will create numerous opportunities, ranging from the study of thermal transport in the ballistic regime to charge, spin, and energy transfer processes with atomic spatial and femtosecond temporal resolution. Studies involving complicated split-and-delay lines have not yet been successful in achieving this goal. Here we propose a novel, simple method based on the Talbot effect for converging beams, which can easily be implemented at current x-ray free electron lasers. We validate our proposal by analyzing printed interference patterns on polymethyl methacrylate and gold samples using X-ray pulses.- 24 January 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (3) , 574-577
Towards X-ray transient grating spectroscopy
The extension of transient grating spectroscopy to the x-ray regime will create numerous opportunities, ranging from the study of thermal transport in the ballistic regime to charge, spin, and energy transfer processes with atomic spatial and femtosecond temporal resolution. Studies involving complicated split-and-delay lines have not yet been successful in achieving this goal. Here we propose a novel, simple method based on the Talbot effect for converging beams, which can easily be implemented at current x-ray free electron lasers. We validate our proposal by analyzing printed interference patterns on polymethyl methacrylate and gold samples using X-ray pulses.- Open Access
- 16 February 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (4) , 4989-5004
At-wavelength optics characterisation via X-ray speckle- and grating-based unified modulated pattern analysis
The current advances in new generation X-ray sources are calling for the development and improvement of high-performance optics. Techniques for high-sensitivity phase sensing and wavefront characterisation, preferably performed at-wavelength, are increasingly required for quality control, optimisation and development of such devices. We here show that the recently proposed unified modulated pattern analysis (UMPA) can be used for these purposes. We characterised two polymer X-ray refractive lenses and quantified the effect of beam damage and shape errors on their refractive properties. Measurements were performed with two different setups for UMPA and validated with conventional X-ray grating interferometry. Due to its adaptability to different setups, the ease of implementation and cost-effectiveness, we expect UMPA to find applications for high-throughput quantitative optics characterisation and wavefront sensing.
- 16 February 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (4) , 4989-5004
Open AccessAt-wavelength optics characterisation via X-ray speckle- and grating-based unified modulated pattern analysis
The current advances in new generation X-ray sources are calling for the development and improvement of high-performance optics. Techniques for high-sensitivity phase sensing and wavefront characterisation, preferably performed at-wavelength, are increasingly required for quality control, optimisation and development of such devices. We here show that the recently proposed unified modulated pattern analysis (UMPA) can be used for these purposes. We characterised two polymer X-ray refractive lenses and quantified the effect of beam damage and shape errors on their refractive properties. Measurements were performed with two different setups for UMPA and validated with conventional X-ray grating interferometry. Due to its adaptability to different setups, the ease of implementation and cost-effectiveness, we expect UMPA to find applications for high-throughput quantitative optics characterisation and wavefront sensing.
- Open Access
- 6 July 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-7
In-vivo X-ray Dark-Field Chest Radiography of a Pig
X-ray chest radiography is an inexpensive and broadly available tool for initial assessment of the lung in clinical routine, but typically lacks diagnostic sensitivity for detection of pulmonary diseases in their early stages. Recent X-ray dark-field (XDF) imaging studies on mice have shown significant improvements in imaging-based lung diagnostics. Especially in the case of early diagnosis of chronic obstructive pulmonary disease (COPD), XDF imaging clearly outperforms conventional radiography. However, a translation of this technique towards the investigation of larger mammals and finally humans has not yet been achieved. In this letter, we present the firstin-vivoXDF full-field chest radiographs (32 × 35 cm2) of a living pig, acquired with clinically compatible parameters (40 s scan time, approx. 80 µSv dose). For imaging, we developed a novel high-energy XDF system that overcomes the limitations of currently established setups. Our XDF radiographs yield sufficiently high image quality to enable radiographic evaluation of the lungs. We consider this a milestone in the bench-to-bedside translation of XDF imaging and expect XDF imaging to become an invaluable tool in clinical practice, both as a general chest X-ray modality and as a dedicated tool for high-risk patients affected by smoking, industrial work and indoor cooking.
- 6 July 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-7
Open AccessIn-vivo X-ray Dark-Field Chest Radiography of a Pig
X-ray chest radiography is an inexpensive and broadly available tool for initial assessment of the lung in clinical routine, but typically lacks diagnostic sensitivity for detection of pulmonary diseases in their early stages. Recent X-ray dark-field (XDF) imaging studies on mice have shown significant improvements in imaging-based lung diagnostics. Especially in the case of early diagnosis of chronic obstructive pulmonary disease (COPD), XDF imaging clearly outperforms conventional radiography. However, a translation of this technique towards the investigation of larger mammals and finally humans has not yet been achieved. In this letter, we present the firstin-vivoXDF full-field chest radiographs (32 × 35 cm2) of a living pig, acquired with clinically compatible parameters (40 s scan time, approx. 80 µSv dose). For imaging, we developed a novel high-energy XDF system that overcomes the limitations of currently established setups. Our XDF radiographs yield sufficiently high image quality to enable radiographic evaluation of the lungs. We consider this a milestone in the bench-to-bedside translation of XDF imaging and expect XDF imaging to become an invaluable tool in clinical practice, both as a general chest X-ray modality and as a dedicated tool for high-risk patients affected by smoking, industrial work and indoor cooking.