SESelen Küçükkaya Eren

Selen Küçükkaya Eren

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Selen Küçükkaya Eren has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Regulatory Role of Vitamin D on Dental Pulp Stem Cells in Inflammatory Conditions: An In Vitro Study

    by Elham Bahador Zirh, Selim Zirh, Naciye Dilara Zeybek, Selen Kucukkaya Eren

  • Open Access

    Effects of different platform preparation and retrieval techniques on broken file removal and fracture strength

    by Esra Yavas, Selen Kucukkaya Eren

    The aim was to evaluate the effects of different strategies on broken instrument removal and root fracture strength. After canal preparation of anterior single-rooted teeth, the samples were divided into one control group (n = 10) and six experimental groups (n = 15). A #25/.06 rotary file was broken at a length of 4 mm in the middle-third canal region in the experimental groups, and no instrument fractures were created in the control group. Access to the instrument was achieved with Gates-Glidden (GG) burs or ultrasonic tips. Dentin around the instrument was removed to create partial or full platforms. Finally, the instruments were removed with ultrasonic tips or a BTR Pen. The effectiveness of broken instrument removal, the duration of removal, and any complications that occurred were recorded. All the root canals were obturated. Fracture strength analysis was performed using a universal testing machine. Statistical analysis was performed using the Kruskal-Wallis and Dunn tests (p < 0.05). All broken instruments were successfully removed. The access time to the broken instrument in the groups using GG burs was shorter than that in the groups using ultrasonic tips (p < 0.05), while there was no significant difference between the groups in terms of total removal time (p > 0.05). The fracture strength of the control group was similar to that of the group in which ultrasonic tips were used to access the broken instrument and to create a full platform, and the BTR Pen was used for the removal of the broken instrument (p > 0.05), but showed higher fracture strength than that of the other experimental groups (p < 0.05). Different strategies used in the removal of broken instruments affected access time and root fracture strength.

  • Open Access

    Effect of treatment variables on apical extrusion of debris during root canal retreatment: A systematic review and meta-analysis of laboratory studies

    by Emel Uzunoğlu Özyürek, Selen Küçükkaya Eren, Sevilay Karahan

    Background. This study aimed to systematically and comprehensively review the effect of various treatment variables on apically extruded debris (AED) during non-surgical root canal retreatment (NSRCRT). Methods. The study protocol is shared in the Open Science Framework database (https://osf. io/kjtdg/?view_only=17060180705745ec9dae9a01614f3880). An electronic search was conducted up to July 2022 to reveal related studies. Two reviewers critically assessed the studies for eligibility against inclusion and exclusion criteria and data extraction. Quantitative data synthesis was performed, and the risk of bias in the studies was also evaluated. Results. Forty-six studies were included in the systematic review and 14 in the meta-analysis. Conflicting or limited evidence was found for the effect of sealer type, obturation technique, and solvent use. The manual instrumentation increased the amount of AED compared to rotary instrumentation during the removal of filling materials (P<0.001). There was no significant difference in the amount of AED between the use of rotary and reciprocating files during the removal of filling materials (P=0.181). Conclusion. Rotary instruments can be recommended instead of manual instruments during the removal of filling materials to control the amount of AED. Further studies with a low risk of bias are needed to clarify the effect of other treatment variables on AED during NSRCRT.


  • Open Access

    Effect of final irrigation protocols with chitosan nanoparticle and genipin on dentine against collagenase degradation: An ex‐vivo study

    by S. N. Şengül, S. Ozturk, K. Ulubayram, N. Pekel Bayramgil, S. Kucukkaya Eren

    Aim: Endodontic irrigants may affect the mechanical and chemical properties of dentine. This study evaluated the effects of various final irrigation protocols including the use of chitosan nanoparticle (CSnp) and cross‐linking with genipin on the (1) mechanical and (2) chemical properties of dentine against enzymatic degradation.Methodology: CSnp was synthesized and characterized considering physiochemical parameters and stability. The root canals of 90 single‐rooted teeth were prepared and irrigated with NaOCl. Dentine discs were obtained and divided into groups according to the following irrigation protocols: Group NaOCl+EDTA, Group NaOCl+CSnp, Group NaOCl+EDTA+CSnp, Group NaOCl+CSnp+Genipin, Group NaOCl+EDTA+CSnp+Genipin and Group distilled water. (1) Mechanical changes were determined by microhardness analysis using Vickers‐tester. (2) Chemical changes were determined by evaluating molecular and elemental compositions of dentine using Fourier transform infrared spectroscopy (FTIR) analysis and scanning electron microscope (SEM)/energy dispersive X‐ray spectroscopy (EDS) analysis, respectively. All analyses were repeated after the discs were kept in collagenase for 24 h. Data were analysed with repeated measures analysis of variance and Bonferroni correction for microhardness analysis, and Kruskal–Wallis and Wilcoxon tests for FTIR and SEM/EDS analyses (p = .05).Results: (1) Collagenase application did not have a negative effect on microhardness only in Group NaOCl+EDTA+CSnp+Genipin when compared with the post‐irrigation values (p > .05). Post‐collagenase microhardness of Group NaOCl+EDTA+CSnp and Group NaOCl+CSnp+Genipin was similar to the initial microhardness (p > .05). (2) After collagenase, Amide III/ ratio presented no change in Group NaOCl+EDTA+CSnp, Group NaOCl+CSnp+Genipin and Group NaOCl+EDTA+CSnp+Genipin (p > .05), while decreased in other groups (p < .05). Collagenase did not affect / ratio in the groups (p > .05). There were no changes in the groups in terms of elemental level before and after collagenase application (p > .05).Conclusions: CSnp and genipin positively affected the microhardness and molecular composition of dentine. This effect was more pronounced when CSnp was used after EDTA.


  • Effects of different treatment modalities on biomechanical behavior of maxillary incisors with external invasive cervical resorption at different progression levels

    by Sevinc Askerbeyli Örs, Selen Küçükkaya Eren

    Background/Aim: This study aimed to evaluate the biomechanical behavior of maxillary incisors with external invasive cervical resorption (EICR) at different progression levels after receiving different modes of treatment under occlusal forces using finite element analysis (FEA).Materials and Methods: Three‐dimensional (3D) models of intact maxillary central incisors were constructed and modified to include EICR cavities with different progression levels in the buccal cervical areas. The EICR cavities confined to dentin were repaired using Biodentine™ (Septodont Ltd., Saint Maur des Fausse ́s, France), resin composite, or glass ionomer cement (GIC) . Additionally, EICR cavities with pulp invasion requiring direct pulp capping were simulated as repaired using Biodentine only or 1 mm thick Biodentine and either resin composite or GIC for the rest of the cavity. Moreover, models with root canal treatment and EICR defects repaired using Biodentine, resin composites, or GIC were also generated. A force of 240 N was applied to the incisal edge. The principal stresses in the dentin were evaluated.Results: GIC showed more favorable results than the other materials in EICR cavities confined to the dentin. However, Biodentine alone resulted in more favorable minimum principal stresses (Pmin) compared to other materials in EICR cavities with close pulp proximity. Exceptionally, the models localized in the coronal third of the root with a circumferential extension of the cavity >90° showed more favorable results for GIC. The presence of root canal treatment had no significant effect on stress values.Conclusions: Based on this FEA study the use of GIC in EICR lesions confined to the dentin is recommended. However, Biodentine may be a better option for restoring EICR lesions close to the pulp with or without root canal treatment. Except when the circumferential extension of the cavity is >90°, the use of GIC may be more advantageous.


  • Clinical applications of calcium silicate‐based materials: a narrative review

    by S Küçükkaya Eren

    Calcium silicate‐based materials are hydrophilic materials with biocompatibility and bioactivity properties. Despite many advantages, they might present some problems related to discolouration, setting time, manipulation and solubility depending on the composition of the product and the type of clinical application. Calcium silicate‐based materials can be evaluated under two types according to their intended use: calcium silicate‐based cements (CSCs) and calcium silicate‐based sealers (CSSs). CSCs can be used in many endodontic procedures including perforation repair, resorption repair, apical barriers, guided endodontic repair, vital pulp treatment, endodontic surgery, root fractures and root canal filling as a core obturation material. CSSs are available for use with gutta‐percha to obturate root canals using cold and warm techniques, including the sealer‐based obturation technique. The purpose of this review is to evaluate the available literature on CSCs and CSSs and to provide up‐to‐date information and recommendations for their clinical applications.


  • Effect of different sealer activation techniques on dentinal tubule penetration

    by Ahmet Keles, Sevinc Askerbeyli Ors, Nuhan Purali, Selen Kucukkaya Eren

    The aim of this study was to evaluate the influence of different activation techniques on dentin tubule penetration of root canal sealer. Seventy‐five teeth with single canals were chemomechanically prepared. A calcium silicate‐based sealer was stained with a fluorescent dye (rhodamine B), placed into the canals and activated according to the following groups: control (no activation), EDDY, EndoActivator, ultrasonic and XP‐Endo Finisher. Then, the samples were obturated. The percentages of sealer penetration at various depth levels of root sections were measured with confocal laser scanning microscopy. XP‐Endo Finisher presented the highest penetration at 50 μm (p < 0.05). XP‐Endo Finisher showed similar penetration with EDDY at 100 and 200 μm (p > 0.05) while presented higher penetration than the other groups (p < 0.05). At 500 μm, XP‐Endo Finisher presented higher penetration than EndoActivator (p < 0.05) while similar penetration with the other groups (p > 0.05). XP‐Endo Finisher can be recommended for activation during sealer placement for better penetration into dentin tubules.


  • Open Access

    Combined effects of bone morphogenetic protein-7 and mineral trioxide aggregate on the proliferation, migration, and differentiation of human dental pulp stem cells

    by Selen Küçükkaya Eren, Elham Bahador Zirh, Selim Zirh, Parisa Sharafi, Naciye Dilara Zeybek

    The aim of this study was to assess the effects of the combined use of bone morphogenetic protein-7 (BMP-7) and mineral trioxide aggregate (MTA) on the proliferation, migration, and differentiation of human dental pulp stem cells (DPSCs). For the proliferation analysis, DPSCs were incubated with a growth medium and treated with MTA and/or BMP-7 at different concentrations. For the following analyses, DPSCs were incubated with a differentiation medium and treated with MTA and/or BMP-7. Moreover, there were groups in which DPSCs were incubated with the growth medium (control), the differentiation medium, or DMEM/F12 containing fetal bovine serum, and not treated with MTA or BMP-7. Cell proliferation was analyzed using the WST-1 assay. The odontogenic/osteogenic differentiation was evaluated by immunocytochemistry, alkaline phosphatase (ALP) activity assay, alizarin red staining, and reverse transcription-quantitative polymerase chain reaction (RT-qPCR). Cell migration was evaluated using a wound-healing assay. Data were analyzed using analysis of variance and Tukey test (p=0.05). The use of BMP-7 with MTA presented no significant effect on cell proliferation in comparison with the treatment with MTA alone (p>0.05), but showed higher ALP activity, increased mineralization, and higher expression of DMP1 and DSPP when compared with other groups (p<0.05). Nestin expression was higher in the control group than in groups treated with MTA and/or BMP-7 (p<0.05). The cell migration rate increased after treatment with MTA when compared with other groups in all periods of time (p<0.05). At 72 hours, the wound area was smaller in groups treated with MTA and/or BMP-7 than in the control group (p<0.05). The use of BMP-7 with MTA increased odontogenic/osteogenic differentiation without adversely affecting proliferation and migration of DPSCs. The use of BMP-7 with MTA may improve treatment outcomes by increasing repair and regeneration capacity of DPSCs.


  • Do resin-based root canal sealers cause more postoperative pain than other sealers? A systematic review of clinical studies and meta-analysis

    by Selen Kuecuekkaya Eren, Emel Uzunoglu-Ozyurek, Sevilay Karahan

    Objective: To evaluate whether root canal obturation with resin-based sealers increases the incidence and intensity of post-operative pain compared to other sealer types. Data sources: brary, and gray literature were searched through December 2020. Clinical studies evaluating postoperative pain after obturation with resin-based sealers and other sealer types were included. Risk of bias was assessed through the Cochrane RoB 2.0 tool for randomized clinical trials (RCTs) and ROBINS-I tool for non-ran-domized clinical trials (nRCTs). Pooled relative risks (RR), standard-ized mean differences (SMD), and 95% confidence intervals were calculated for quantitative analyses. Of 524 studies, 11 clinical studies (eight RCTs and three nRCTs) involving 1,123 teeth were included. Four studies were assigned low risk of overall bias while seven studies presented high risk of overall bias. Quantitative analyses were performed with six studies for pain incidence, five studies for pain intensity, and four studies for analgesic intake. There was no significant difference between resin- based sealers and other sealer types in postoperative pain incidence at 24 hours (RR 1.102, P = .53), 48 hours (RR 0.943, P = .93), 72 hours (RR 1.019, P = .93), and 1 week (RR 0.559, P = .31), in pain intensity at 12 hours (SMD 0.100, P = .35), 24 hours (SMD 0.090, P = .25), and 48 hours (SMD 0.217, P = .26), and in analgesic intake at 24 hours (RR 2.253, P = .15) and 72 hours (RR 0.650, P = .59). Conclusion: Based on the available evidence, resin -based sealers do not increase the post- operative pain incidence, intensity, and analgesic intake com- pared to other sealer types. (Quintessence Int 2022;53: 472-483; doi: 10.3290/j.qi.b2887687)


  • Open Access

    Effect of irrigants on the color stability, solubility, and surface characteristics of calcium-silicate based cements

    by Selen Küçükkaya Eren, Sevinc Askerbeyli Örs, Hacer Aksel, Şenay Canay, Duygu Karasan

    Eren SK, et al. Restor Dent Endod. 2022 Feb;47:e10. https://doi.org/10.5395/rde.2022.47.e10