Alexander J. J. Ijsselmuiden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alexander J. J. Ijsselmuiden has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
B. E. Schölzel
Department of Cardiology, Amphia Ziekenhuis, Breda, the Netherlands
2 shared publicationsC. Simsek
Department of Cardiology, Amphia Ziekenhuis, Breda, the Netherlands
2 shared publicationsEric Boersma
Department of Cardiology ErasmusMC Rotterdam the Netherlands
2 shared publicationsGiovanni Amoroso
Department of Cardiology, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands
2 shared publicationsM. Meuwissen
Department of Cardiology, Amphia Ziekenhuis, Breda, the Netherlands
2 shared publications- Selina Vlieger
Affiliation Albert Schweitzer Ziekenhuis, Dordrecht, The Netherlands
2 shared publications
Latest Publications
- 19 May 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (1) , 625-632
Comparison of Sirolimus—Versus Paclitaxel‐Coated Balloons in Coronary Artery Disease: One‐Year Results of Two Real‐World Prospective Registries
Background: Paclitaxel‐(PCB) and sirolimus‐coated balloons (SCB) are used for treatment of in‐stent restenosis (ISR) and de novo (DN) lesions. Studies comparing major adverse cardiac events (MACE) after PCB versus SCB are limited. Aims: This study aims to contribute to this knowledge gap and enhance the understanding of optimal strategies for treating ISR and DN lesions. Methods: EASTBOURNE and PEARL are large‐scale, prospective clinical registries, evaluating the performance of drug‐coated balloons. PEARL included patients who underwent percutaneous coronary intervention using Protege PCB and EASTBOURNE included patients treated with MagicTouch SCB in study centers in Europe and Asia. We combined these registries and used logistic regression analysis to assess the association between SCB/PCB and the likelihood of experiencing MACE, a composite of all‐cause mortality, myocardial infarction (MI) and target‐lesion revascularisation (TLR) at 1‐year follow‐up. Results: Out of 2596 patients, MACE was observed more frequently in ISR lesions ( n = 1292 patients, SCB:17.8% vs. PCB:14.1%, p = 0.12) versus DN lesions ( n = 1304 patients, SCB:6.4% vs. PCB:6.1%, p = 1.00). The adjusted hazards ratio (HR) for MACE was 1.17 (95% CI: 0.59–1.23, p = 0.40). As regards DN lesions, no significant difference was found in MACE (SCB: 6.4% vs. PCB 6.1%, p = 1.00). The adjusted HR for MACE was 1.24 (95% CI: 0.20–2.01, p = 0.13). There were no differences in the individual components of the primary endpoint. Conclusions: This real‐world comparison demonstrated comparable outcomes between new‐generation PCB and SCB in terms of MACE at 1‐year follow‐up, across different lesion settings.
- 19 May 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (1) , 625-632
Comparison of Sirolimus—Versus Paclitaxel‐Coated Balloons in Coronary Artery Disease: One‐Year Results of Two Real‐World Prospective Registries
Background: Paclitaxel‐(PCB) and sirolimus‐coated balloons (SCB) are used for treatment of in‐stent restenosis (ISR) and de novo (DN) lesions. Studies comparing major adverse cardiac events (MACE) after PCB versus SCB are limited. Aims: This study aims to contribute to this knowledge gap and enhance the understanding of optimal strategies for treating ISR and DN lesions. Methods: EASTBOURNE and PEARL are large‐scale, prospective clinical registries, evaluating the performance of drug‐coated balloons. PEARL included patients who underwent percutaneous coronary intervention using Protege PCB and EASTBOURNE included patients treated with MagicTouch SCB in study centers in Europe and Asia. We combined these registries and used logistic regression analysis to assess the association between SCB/PCB and the likelihood of experiencing MACE, a composite of all‐cause mortality, myocardial infarction (MI) and target‐lesion revascularisation (TLR) at 1‐year follow‐up. Results: Out of 2596 patients, MACE was observed more frequently in ISR lesions ( n = 1292 patients, SCB:17.8% vs. PCB:14.1%, p = 0.12) versus DN lesions ( n = 1304 patients, SCB:6.4% vs. PCB:6.1%, p = 1.00). The adjusted hazards ratio (HR) for MACE was 1.17 (95% CI: 0.59–1.23, p = 0.40). As regards DN lesions, no significant difference was found in MACE (SCB: 6.4% vs. PCB 6.1%, p = 1.00). The adjusted HR for MACE was 1.24 (95% CI: 0.20–2.01, p = 0.13). There were no differences in the individual components of the primary endpoint. Conclusions: This real‐world comparison demonstrated comparable outcomes between new‐generation PCB and SCB in terms of MACE at 1‐year follow‐up, across different lesion settings.
- Open Access
- 22 June 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (13) , 4213
Assessing the Novel Myval Balloon-Expandable Valve with the Evolut Valve: A Propensity-Matched Study
Background: The Myval balloon-expandable (BE) valve has shown encouraging early clinical data in terms of safety and efficacy. Comparative data with other well-established contemporary valves are nonetheless still scarce. This study aims to compare the performance of the Myval BE valve with the Evolut self-expanding (SE) valve. Methods: In this retrospective single-center study, 223 patients with symptomatic severe aortic stenosis (AS) were included and treated with the Myval BE valve (n = 120) or with the Evolut SE valve (n = 103). Then, 91 pairs were compared after matching. Clinical outcomes were evaluated at 30 days and 1 year. Echocardiographic follow-up was performed at 30 days. Results: Procedural complications were rare in both groups. At the 30-day follow-up, no significant difference in cardiac death (Myval: 1% vs. Evolut: 2%, p = 0.56), stroke (2% vs. 4%, p = 0.41) and myocardial infarction (1% vs. 3%, p = 0.31) was observed. A permanent pacemaker implantation (PPI) was significantly less needed in the Myval group (4% vs. 15%, p = 0.01). At 1 year, cardiac death (2% vs. 4%, p = 0.41) and the stroke rate (7% vs. 5%, p = 0.76) were similar. Moderate–severe paravalvular leakage (PVL) was also comparable in both groups (1% vs. 4%, p = 0.17). Conclusion: Safety and efficacy outcomes were comparable between the two valves, except for a higher PPI rate for the Evolut SE valve. Up to 1-year follow-up, clinical outcomes showed acceptable rates of stroke and cardiac death with both valves. Valve hemodynamics were excellent with a low rate of moderate–severe PVL in both groups.
- 22 June 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (13) , 4213
Open AccessAssessing the Novel Myval Balloon-Expandable Valve with the Evolut Valve: A Propensity-Matched Study
Background: The Myval balloon-expandable (BE) valve has shown encouraging early clinical data in terms of safety and efficacy. Comparative data with other well-established contemporary valves are nonetheless still scarce. This study aims to compare the performance of the Myval BE valve with the Evolut self-expanding (SE) valve. Methods: In this retrospective single-center study, 223 patients with symptomatic severe aortic stenosis (AS) were included and treated with the Myval BE valve (n = 120) or with the Evolut SE valve (n = 103). Then, 91 pairs were compared after matching. Clinical outcomes were evaluated at 30 days and 1 year. Echocardiographic follow-up was performed at 30 days. Results: Procedural complications were rare in both groups. At the 30-day follow-up, no significant difference in cardiac death (Myval: 1% vs. Evolut: 2%, p = 0.56), stroke (2% vs. 4%, p = 0.41) and myocardial infarction (1% vs. 3%, p = 0.31) was observed. A permanent pacemaker implantation (PPI) was significantly less needed in the Myval group (4% vs. 15%, p = 0.01). At 1 year, cardiac death (2% vs. 4%, p = 0.41) and the stroke rate (7% vs. 5%, p = 0.76) were similar. Moderate–severe paravalvular leakage (PVL) was also comparable in both groups (1% vs. 4%, p = 0.17). Conclusion: Safety and efficacy outcomes were comparable between the two valves, except for a higher PPI rate for the Evolut SE valve. Up to 1-year follow-up, clinical outcomes showed acceptable rates of stroke and cardiac death with both valves. Valve hemodynamics were excellent with a low rate of moderate–severe PVL in both groups.
- Open Access
- 6 September 2022
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 2022, 1-10
Upper Extremity Function following Transradial Percutaneous Coronary Intervention: Results of the ARCUS Trial
Upper Extremity Function following Transradial Percutaneous Coronary Intervention: Results of the ARCUS Trial: Objectives. To determine the incidence of upper extremity dysfunction (UED), after a transradial percutaneous coronary intervention (TR-PCI). Background. Transradial approach (TRA) is the preferred approach for coronary interventions. However, upper extremity complications may be underreported. Methods. The ARCUS was designed as a prospective cohort study, including 502 consecutive patients admitted for PCI. Patients treated with transfemoral PCI (TF-PCI) acted as a control group. A composite score of physical examinations and questionnaires was used for determining UED. Clinical outcomes were monitored during six months of follow-up, with its primary endpoint at two weeks. Results. A total of 440 TR-PCI and 62 control patients were included. Complete case analysis (n = 330) at 2 weeks of follow-up showed that UED in the TR-PCI group was significantly higher than that in the TF-PCI group: 32.7% versus 13.9%, respectively ( ). The three impaired variables most contributing to UED were impaired elbow extension, wrist flexion, and extension. Multivariate logistic regression showed that smokers were almost three times more likely to develop UED. Conclusions. This study demonstrates that UED seems to occur two times more in TR-PCI than in TF-PCI at 2 weeks of follow-up. However, no significant long-term difference or difference between the intervention arm and the contralateral arm was found at all timepoints.
- 6 September 2022
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 2022, 1-10
Open AccessUpper Extremity Function following Transradial Percutaneous Coronary Intervention: Results of the ARCUS Trial
Upper Extremity Function following Transradial Percutaneous Coronary Intervention: Results of the ARCUS Trial: Objectives. To determine the incidence of upper extremity dysfunction (UED), after a transradial percutaneous coronary intervention (TR-PCI). Background. Transradial approach (TRA) is the preferred approach for coronary interventions. However, upper extremity complications may be underreported. Methods. The ARCUS was designed as a prospective cohort study, including 502 consecutive patients admitted for PCI. Patients treated with transfemoral PCI (TF-PCI) acted as a control group. A composite score of physical examinations and questionnaires was used for determining UED. Clinical outcomes were monitored during six months of follow-up, with its primary endpoint at two weeks. Results. A total of 440 TR-PCI and 62 control patients were included. Complete case analysis (n = 330) at 2 weeks of follow-up showed that UED in the TR-PCI group was significantly higher than that in the TF-PCI group: 32.7% versus 13.9%, respectively ( ). The three impaired variables most contributing to UED were impaired elbow extension, wrist flexion, and extension. Multivariate logistic regression showed that smokers were almost three times more likely to develop UED. Conclusions. This study demonstrates that UED seems to occur two times more in TR-PCI than in TF-PCI at 2 weeks of follow-up. However, no significant long-term difference or difference between the intervention arm and the contralateral arm was found at all timepoints.
- 1 June 2022
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 34 (6) , E462-E468
Clinical Performance of a Paclitaxel Drug-Coated Balloon in Real-World Percutaneous Coronary Intervention Practice: The PEARL Registry
The aim of the registry was to evaluate the safety and efficacy of a paclitaxel DCB in real-world percutaneous coronary intervention practice.
- 1 June 2022
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 34 (6) , E462-E468
Clinical Performance of a Paclitaxel Drug-Coated Balloon in Real-World Percutaneous Coronary Intervention Practice: The PEARL Registry
The aim of the registry was to evaluate the safety and efficacy of a paclitaxel DCB in real-world percutaneous coronary intervention practice.
- Open Access
- 9 March 2020
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 28 (5) , 249-252
The rationale of using cerebral embolic protection devices during transcatheter aortic valve implantation
Aortic valve stenosis is one of the most common valvular abnormalities, which can manifest as angina, syncope, dyspnoea and sudden cardiac death. Transcatheter aortic valve implantation (TAVI) has been introduced as an alternative to surgical valve replacement in patients with severe aortic valve stenosis, resulting in less morbidity, shorter time to recovery and similar mortality rates. Progress in this field has reduced complication rates. However, the incidence of peri-procedural stroke remains relatively high (around 4%). To fully utilise the potential of TAVI, cerebral embolic protection devices (CEPD) have been developed and introduced. In this position paper, we aim to summarise the available data on several CEPD.
- 9 March 2020
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 28 (5) , 249-252
Open AccessThe rationale of using cerebral embolic protection devices during transcatheter aortic valve implantation
Aortic valve stenosis is one of the most common valvular abnormalities, which can manifest as angina, syncope, dyspnoea and sudden cardiac death. Transcatheter aortic valve implantation (TAVI) has been introduced as an alternative to surgical valve replacement in patients with severe aortic valve stenosis, resulting in less morbidity, shorter time to recovery and similar mortality rates. Progress in this field has reduced complication rates. However, the incidence of peri-procedural stroke remains relatively high (around 4%). To fully utilise the potential of TAVI, cerebral embolic protection devices (CEPD) have been developed and introduced. In this position paper, we aim to summarise the available data on several CEPD.
- 23 March 2019
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 94 (7) , 966-971
Dutch multicenter experience using the STENTYS Xposition S self‐apposing stent in complex coronary lesions
Objectives: The aim is to assess the experience in the Netherlands using the Xposition S self‐apposing stent in complex coronary lesions in clinical practice.Background: Treatment of complex coronary lesions could be accompanied with stent sizing difficulties and complications, particularly due to vessel overdilation or stent underexpansion. The self‐apposing feature of the Xposition S stent (STENTYS, Paris, France) supports good strut apposition in complex anatomies and allows for an increase in diameter after implantation.Methods: In this real‐world registry, data from patients treated with Xposition S in four Dutch clinical sites were prospectively collected and analyzed. Any patient suitable for implantation with Xposition S according to current recommendations was enrolled. Primary endpoint was major adverse cardiac events (MACE) at 1 year.Results: Between 2015 and 2018, data from 251 patients were collected. Clinical presentation was an acute coronary syndrome in majority of the patients (76.9%). Main angiographic indications were lesions in aneurysmatic or ectatic vessels (32.3%), thrombus containing lesions (13.1%), and bifurcation/left main stenosis (10.4%). Most of the target lesions (TLs) were classified as AHA/ACC Type C (53.6%). Despite lesion complexity, device was successfully implanted at TL in 96.8%. MACE rate, reported on patients having completed 1‐year follow‐up (n = 203), was 6.6%, with low rate of definite/probable stent thrombosis (1.0%).Conclusions: In clinical practice of several Dutch sites, STENTYS Xposition S showed good procedural results and low 1‐year clinical events rate, despite complex coronary anatomy.
- 23 March 2019
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 94 (7) , 966-971
Dutch multicenter experience using the STENTYS Xposition S self‐apposing stent in complex coronary lesions
Objectives: The aim is to assess the experience in the Netherlands using the Xposition S self‐apposing stent in complex coronary lesions in clinical practice.Background: Treatment of complex coronary lesions could be accompanied with stent sizing difficulties and complications, particularly due to vessel overdilation or stent underexpansion. The self‐apposing feature of the Xposition S stent (STENTYS, Paris, France) supports good strut apposition in complex anatomies and allows for an increase in diameter after implantation.Methods: In this real‐world registry, data from patients treated with Xposition S in four Dutch clinical sites were prospectively collected and analyzed. Any patient suitable for implantation with Xposition S according to current recommendations was enrolled. Primary endpoint was major adverse cardiac events (MACE) at 1 year.Results: Between 2015 and 2018, data from 251 patients were collected. Clinical presentation was an acute coronary syndrome in majority of the patients (76.9%). Main angiographic indications were lesions in aneurysmatic or ectatic vessels (32.3%), thrombus containing lesions (13.1%), and bifurcation/left main stenosis (10.4%). Most of the target lesions (TLs) were classified as AHA/ACC Type C (53.6%). Despite lesion complexity, device was successfully implanted at TL in 96.8%. MACE rate, reported on patients having completed 1‐year follow‐up (n = 203), was 6.6%, with low rate of definite/probable stent thrombosis (1.0%).Conclusions: In clinical practice of several Dutch sites, STENTYS Xposition S showed good procedural results and low 1‐year clinical events rate, despite complex coronary anatomy.
- Open Access
- 31 August 2018
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 26 (10) , 473-483
Appropriate use criteria for optical coherence tomography guidance in percutaneous coronary interventions
Optical coherence tomography (OCT) enables detailed imaging of the coronary wall, lumen and intracoronary implanted devices. Responding to the lack of specific appropriate use criteria (AUC) for this technique, we conducted a literature review and a procedure for appropriate use criteria.
- 31 August 2018
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 26 (10) , 473-483
Open AccessAppropriate use criteria for optical coherence tomography guidance in percutaneous coronary interventions
Optical coherence tomography (OCT) enables detailed imaging of the coronary wall, lumen and intracoronary implanted devices. Responding to the lack of specific appropriate use criteria (AUC) for this technique, we conducted a literature review and a procedure for appropriate use criteria.
- Open Access
- 18 December 2017
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 26 (2) , 94-101
Comparison between the STENTYS self-apposing bare metal and paclitaxel-eluting coronary stents for the treatment of saphenous vein grafts (ADEPT trial)
To describe the safety and performance of STENTYS self-expandable bare metal stents (BMS) versus paclitaxel-eluting stents (PES) in saphenous vein grafts (SVGs).
- 18 December 2017
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 26 (2) , 94-101
Open AccessComparison between the STENTYS self-apposing bare metal and paclitaxel-eluting coronary stents for the treatment of saphenous vein grafts (ADEPT trial)
To describe the safety and performance of STENTYS self-expandable bare metal stents (BMS) versus paclitaxel-eluting stents (PES) in saphenous vein grafts (SVGs).
- Open Access
- 6 July 2017
- Published by Ommega Online Publishers in JOURNAL OF HEART AND CARDIOLOGY
- Vol. 3 (2) , 33-38
Upper Extremity Function after Transradial Percutaneous Coronary Intervention Short-Term Interim Results of the ARCUS Study
Aims: To examine the short-term effects of transradial percutaneous coronary interventions on the upper extremities function. Method and results: This is an interim analysis of the Effects of trAnsRadial perCUtaneouS coronary intervention on upper extremity function (ARCUS) study. Out of 191 patients evaluated at 2 weeks after they had undergone a transradial percutaneous coronary intervention, 120 (62.8%) had manifestations of upper extremity dysfunction on the side of the intervention. The main abnormalities were a decrease in sensibility, a ≥15% increase in the Disabilities of the Hand and Shoulder questionnaire score and a ≥2 cm increase in hand and forearm volumes. Radial artery occlusions occurred in 12 patients in the upper extremity dysfunction versus 1 patient in the no upper extremity dysfunction group (p=0.03). Patients with upper extremity dysfunction were significantly more likely to have a family history of heart disease (50% vs. 26.8%; p =0.002). In addition, there was a trend (p=0.07) toward a greater proportion of previous smokers in the group with upper extremity dysfunction than in the other group. Conclusions: Upper extremity dysfunction after transradial percutaneous coronary intervention is a medical concern. However, our original score may be overly sensitive and overestimate the rate of upper extremity dysfunction. Further analyses are needed, as well as perhaps a modification of the primary endpoint.
- 6 July 2017
- Published by Ommega Online Publishers in JOURNAL OF HEART AND CARDIOLOGY
- Vol. 3 (2) , 33-38
Open AccessUpper Extremity Function after Transradial Percutaneous Coronary Intervention Short-Term Interim Results of the ARCUS Study
Aims: To examine the short-term effects of transradial percutaneous coronary interventions on the upper extremities function. Method and results: This is an interim analysis of the Effects of trAnsRadial perCUtaneouS coronary intervention on upper extremity function (ARCUS) study. Out of 191 patients evaluated at 2 weeks after they had undergone a transradial percutaneous coronary intervention, 120 (62.8%) had manifestations of upper extremity dysfunction on the side of the intervention. The main abnormalities were a decrease in sensibility, a ≥15% increase in the Disabilities of the Hand and Shoulder questionnaire score and a ≥2 cm increase in hand and forearm volumes. Radial artery occlusions occurred in 12 patients in the upper extremity dysfunction versus 1 patient in the no upper extremity dysfunction group (p=0.03). Patients with upper extremity dysfunction were significantly more likely to have a family history of heart disease (50% vs. 26.8%; p =0.002). In addition, there was a trend (p=0.07) toward a greater proportion of previous smokers in the group with upper extremity dysfunction than in the other group. Conclusions: Upper extremity dysfunction after transradial percutaneous coronary intervention is a medical concern. However, our original score may be overly sensitive and overestimate the rate of upper extremity dysfunction. Further analyses are needed, as well as perhaps a modification of the primary endpoint.