AIAlexander J. J. Ijsselmuiden

Alexander J. J. Ijsselmuiden

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexander J. J. Ijsselmuiden has a total of 89 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of Sirolimus—Versus Paclitaxel‐Coated Balloons in Coronary Artery Disease: One‐Year Results of Two Real‐World Prospective Registries

    by Selina Vlieger, Jin M. Cheng, Filippo Luca Gurgoglione, Tay M. Heang, Alexander J. J. Ijsselmuiden, Alfonso Ielasi, Eric Boersma, Lee C. Yan, Alessandro Sciahbasi, Ramesh Singh, et al.

    Background: Paclitaxel‐(PCB) and sirolimus‐coated balloons (SCB) are used for treatment of in‐stent restenosis (ISR) and de novo (DN) lesions. Studies comparing major adverse cardiac events (MACE) after PCB versus SCB are limited. Aims: This study aims to contribute to this knowledge gap and enhance the understanding of optimal strategies for treating ISR and DN lesions. Methods: EASTBOURNE and PEARL are large‐scale, prospective clinical registries, evaluating the performance of drug‐coated balloons. PEARL included patients who underwent percutaneous coronary intervention using Protege PCB and EASTBOURNE included patients treated with MagicTouch SCB in study centers in Europe and Asia. We combined these registries and used logistic regression analysis to assess the association between SCB/PCB and the likelihood of experiencing MACE, a composite of all‐cause mortality, myocardial infarction (MI) and target‐lesion revascularisation (TLR) at 1‐year follow‐up. Results: Out of 2596 patients, MACE was observed more frequently in ISR lesions ( n = 1292 patients, SCB:17.8% vs. PCB:14.1%, p = 0.12) versus DN lesions ( n = 1304 patients, SCB:6.4% vs. PCB:6.1%, p = 1.00). The adjusted hazards ratio (HR) for MACE was 1.17 (95% CI: 0.59–1.23, p = 0.40). As regards DN lesions, no significant difference was found in MACE (SCB: 6.4% vs. PCB 6.1%, p = 1.00). The adjusted HR for MACE was 1.24 (95% CI: 0.20–2.01, p = 0.13). There were no differences in the individual components of the primary endpoint. Conclusions: This real‐world comparison demonstrated comparable outcomes between new‐generation PCB and SCB in terms of MACE at 1‐year follow‐up, across different lesion settings.


  • Open Access

    Assessing the Novel Myval Balloon-Expandable Valve with the Evolut Valve: A Propensity-Matched Study

    by Jonathan Halim, Maxim Rooijakkers, Peter Den Heijer, Milad El Haddad, Ben van Den Branden, Jeroen Vos, Bas Schölzel, Martijn Meuwissen, Menno van Gameren, Saloua El Messaoudi, et al.

    Background: The Myval balloon-expandable (BE) valve has shown encouraging early clinical data in terms of safety and efficacy. Comparative data with other well-established contemporary valves are nonetheless still scarce. This study aims to compare the performance of the Myval BE valve with the Evolut self-expanding (SE) valve. Methods: In this retrospective single-center study, 223 patients with symptomatic severe aortic stenosis (AS) were included and treated with the Myval BE valve (n = 120) or with the Evolut SE valve (n = 103). Then, 91 pairs were compared after matching. Clinical outcomes were evaluated at 30 days and 1 year. Echocardiographic follow-up was performed at 30 days. Results: Procedural complications were rare in both groups. At the 30-day follow-up, no significant difference in cardiac death (Myval: 1% vs. Evolut: 2%, p = 0.56), stroke (2% vs. 4%, p = 0.41) and myocardial infarction (1% vs. 3%, p = 0.31) was observed. A permanent pacemaker implantation (PPI) was significantly less needed in the Myval group (4% vs. 15%, p = 0.01). At 1 year, cardiac death (2% vs. 4%, p = 0.41) and the stroke rate (7% vs. 5%, p = 0.76) were similar. Moderate–severe paravalvular leakage (PVL) was also comparable in both groups (1% vs. 4%, p = 0.17). Conclusion: Safety and efficacy outcomes were comparable between the two valves, except for a higher PPI rate for the Evolut SE valve. Up to 1-year follow-up, clinical outcomes showed acceptable rates of stroke and cardiac death with both valves. Valve hemodynamics were excellent with a low rate of moderate–severe PVL in both groups.


  • Open Access

    Upper Extremity Function following Transradial Percutaneous Coronary Intervention: Results of the ARCUS Trial

    by Eva M. Zwaan, Elena S. Cheung, Alexander J. J. Ijsselmuiden, Carlo A. J. Holtzer, Ton A. R. Schreuders, Marcel J. M Kofflard, J. Henk Coert

    Upper Extremity Function following Transradial Percutaneous Coronary Intervention: Results of the ARCUS Trial: Objectives. To determine the incidence of upper extremity dysfunction (UED), after a transradial percutaneous coronary intervention (TR-PCI). Background. Transradial approach (TRA) is the preferred approach for coronary interventions. However, upper extremity complications may be underreported. Methods. The ARCUS was designed as a prospective cohort study, including 502 consecutive patients admitted for PCI. Patients treated with transfemoral PCI (TF-PCI) acted as a control group. A composite score of physical examinations and questionnaires was used for determining UED. Clinical outcomes were monitored during six months of follow-up, with its primary endpoint at two weeks. Results. A total of 440 TR-PCI and 62 control patients were included. Complete case analysis (n = 330) at 2 weeks of follow-up showed that UED in the TR-PCI group was significantly higher than that in the TF-PCI group: 32.7% versus 13.9%, respectively ( ). The three impaired variables most contributing to UED were impaired elbow extension, wrist flexion, and extension. Multivariate logistic regression showed that smokers were almost three times more likely to develop UED. Conclusions. This study demonstrates that UED seems to occur two times more in TR-PCI than in TF-PCI at 2 weeks of follow-up. However, no significant long-term difference or difference between the intervention arm and the contralateral arm was found at all timepoints.


  • Clinical Performance of a Paclitaxel Drug-Coated Balloon in Real-World Percutaneous Coronary Intervention Practice: The PEARL Registry

    by Selina Vlieger, Jin Cheng, Rohit Oemrawsingh, Auke Weevers, Jawed Polad, Ben Gho, MD Martijn Meuwissen, Peter Den Heijer, Eric Boersma, Alexander Ijsselmuiden

    The aim of the registry was to evaluate the safety and efficacy of a paclitaxel DCB in real-world percutaneous coronary intervention practice.


  • Open Access

    The rationale of using cerebral embolic protection devices during transcatheter aortic valve implantation

    by C. Simsek, B. E. Schölzel, P. Den Heijer, J. Vos, M. Meuwissen, B. van Den Branden, A. J. J. Ijsselmuiden

    Aortic valve stenosis is one of the most common valvular abnormalities, which can manifest as angina, syncope, dyspnoea and sudden cardiac death. Transcatheter aortic valve implantation (TAVI) has been introduced as an alternative to surgical valve replacement in patients with severe aortic valve stenosis, resulting in less morbidity, shorter time to recovery and similar mortality rates. Progress in this field has reduced complication rates. However, the incidence of peri-procedural stroke remains relatively high (around 4%). To fully utilise the potential of TAVI, cerebral embolic protection devices (CEPD) have been developed and introduced. In this position paper, we aim to summarise the available data on several CEPD.


  • Dutch multicenter experience using the STENTYS Xposition S self‐apposing stent in complex coronary lesions

    by Selina Vlieger, Cihan Simsek, Anaïs Balland, Sami Somi, Gillian Jessurun, Giovanni Amoroso, Floris Kauer, Robert‐Jan van Geuns, Alexander Ijsselmuiden

    Objectives: The aim is to assess the experience in the Netherlands using the Xposition S self‐apposing stent in complex coronary lesions in clinical practice.Background: Treatment of complex coronary lesions could be accompanied with stent sizing difficulties and complications, particularly due to vessel overdilation or stent underexpansion. The self‐apposing feature of the Xposition S stent (STENTYS, Paris, France) supports good strut apposition in complex anatomies and allows for an increase in diameter after implantation.Methods: In this real‐world registry, data from patients treated with Xposition S in four Dutch clinical sites were prospectively collected and analyzed. Any patient suitable for implantation with Xposition S according to current recommendations was enrolled. Primary endpoint was major adverse cardiac events (MACE) at 1 year.Results: Between 2015 and 2018, data from 251 patients were collected. Clinical presentation was an acute coronary syndrome in majority of the patients (76.9%). Main angiographic indications were lesions in aneurysmatic or ectatic vessels (32.3%), thrombus containing lesions (13.1%), and bifurcation/left main stenosis (10.4%). Most of the target lesions (TLs) were classified as AHA/ACC Type C (53.6%). Despite lesion complexity, device was successfully implanted at TL in 96.8%. MACE rate, reported on patients having completed 1‐year follow‐up (n = 203), was 6.6%, with low rate of definite/probable stent thrombosis (1.0%).Conclusions: In clinical practice of several Dutch sites, STENTYS Xposition S showed good procedural results and low 1‐year clinical events rate, despite complex coronary anatomy.


  • Open Access

    Appropriate use criteria for optical coherence tomography guidance in percutaneous coronary interventions

    by A. J. J. Ijsselmuiden, E. M. Zwaan, R. M. Oemrawsingh, M. J. Bom, F. J. W. M. Dankers, M. J. de Boer, C. Camaro, R. J. M. van Geuns, J. Daemen, D. J. van der Heijden, et al.

    Optical coherence tomography (OCT) enables detailed imaging of the coronary wall, lumen and intracoronary implanted devices. Responding to the lack of specific appropriate use criteria (AUC) for this technique, we conducted a literature review and a procedure for appropriate use criteria.


  • Open Access

    Comparison between the STENTYS self-apposing bare metal and paclitaxel-eluting coronary stents for the treatment of saphenous vein grafts (ADEPT trial)

    by A. J. J. Ijsselmuiden, C. Simsek, A. G. van Driel, D. Bouchez, G. Amoroso, P. Vermeersch, P. P. Karjalainen

    To describe the safety and performance of STENTYS self-expandable bare metal stents (BMS) versus paclitaxel-eluting stents (PES) in saphenous vein grafts (SVGs).


  • Open Access

    Upper Extremity Function after Transradial Percutaneous Coronary Intervention Short-Term Interim Results of the ARCUS Study

    by Eva Zwaan, Alexander Jj Ijsselmuiden, Carlo. A.J Holtzer, Robert-Jan M van Geuns, Niels van Royen, Esther Moerman, Giovanni Amoroso, Marco J.Pf. Ritt, Ton A Schreuders, Marcel J.M Kofflard

    Aims: To examine the short-term effects of transradial percutaneous coronary interventions on the upper extremities function. Method and results: This is an interim analysis of the Effects of trAnsRadial perCUtaneouS coronary intervention on upper extremity function (ARCUS) study. Out of 191 patients evaluated at 2 weeks after they had undergone a transradial percutaneous coronary intervention, 120 (62.8%) had manifestations of upper extremity dysfunction on the side of the intervention. The main abnormalities were a decrease in sensibility, a ≥15% increase in the Disabilities of the Hand and Shoulder questionnaire score and a ≥2 cm increase in hand and forearm volumes. Radial artery occlusions occurred in 12 patients in the upper extremity dysfunction versus 1 patient in the no upper extremity dysfunction group (p=0.03). Patients with upper extremity dysfunction were significantly more likely to have a family history of heart disease (50% vs. 26.8%; p =0.002). In addition, there was a trend (p=0.07) toward a greater proportion of previous smokers in the group with upper extremity dysfunction than in the other group. Conclusions: Upper extremity dysfunction after transradial percutaneous coronary intervention is a medical concern. However, our original score may be overly sensitive and overestimate the rate of upper extremity dysfunction. Further analyses are needed, as well as perhaps a modification of the primary endpoint.