SGSteven A. Gard

Steven A. Gard

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steven A. Gard has a total of 100 co-authors. Here are the top co-authors by number of shared publications:

  • Dudley S. Childress

    Biomedical Engineering Department, Northwestern University, Evanston, IL, USA

    10 shared publications
  • Stefania Fatone

    Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, Illinois, United States of America

    7 shared publications
  • Andrew H. Hansen

    Affiliations Minneapolis VA Health Care System, Minneapolis, Minnesota, United States of America, Department of Family Medicine and Community Health, Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota, United States of America

    5 shared publications
  • Stefania Fatone

    5 shared publications
  • Robert D. Lipschutz

    Northwestern University Prosthetics-Orthotics Center, Department of Physical Medicine & Rehabilitation, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611

    4 shared publications
  • Andrew H. Hansen

    Northwestern University Prosthetics Research Laboratory and Rehabilitation Engineering Research Program, Department of Physical Medicine and Rehabilitation, Northwestern University Feinberg School of Medicine, Chicago, IL, USA

    3 shared publications

Latest Publications

  • Open Access

    Development and application of a prosthetist-specific rectification template based on artificial intelligence for the fabrication of transfemoral prosthetic sockets

    by Maria Grazia Santi, Stefania Fatone, Andrew H. Hansen, Steven A. Gard, Andrea Giovanni Cutti

    The prosthetic socket is the most critical component of a lower limb prosthesis, requiring precise customization to the individual’s residual limb. This study presents proof-of-concept for a novel artificial intelligence (AI)-driven rectification template for transfemoral sockets tailored to a single prosthetist. Using a dataset of nine persons with transfemoral amputation, the study workflow required the manual casting and 3D scanning of unrectified and rectified plaster positives, anatomical landmark identification, and unsupervised training of an algorithm using Principal Component Analysis (PCA). The AI captured both explicit and implicit rectification strategies, generating an average rectification template and synergistic modes of variation. Validation was conducted via a leave-one-out approach, comparing AI-generated versus manually crafted rectified positives using clinically-relevant metrics: perimeter and volume differences. The first four PCA modes explained 78% of rectification variability, with key modifications observed in distal and medial regions. Volume differences between AI and manually rectified positives were within clinically acceptable limits for all participants, with 44% rated “good” and 56% “acceptable”. This proof-of-concept provides a new perspective on the application of AI to replicate prosthetist-specific rectification strategies for transfemoral sockets. It may potentially help streamline fabrication by capturing both explicit and implicit prosthetist knowledge. The approach may be useful in clinical training, documentation, and socket fabrication, particularly in resource-limited settings, and may contribute to more consistent and efficient prosthetics care.

  • Open Access

    Randomized crossover trial of hand and hydrostatic casting for custom lower limb prosthetic sockets: Assessing socket comfort and fabrication time

    by Stefania Fatone, Amy Gravely, Andrea Giovanni Cutti, Andrew H. Hansen, Steven A. Gard, on behalf of the Residual Limb Shape Capture Group

    The aim of this study was to compare diagnostic sockets made by hand casting and standing hydrostatic pressure casting in persons with lower limb amputation. This multi-site, single-masked, randomized crossover trial (ClinicalTrials.gov NCT04141748) involved a prosthetist at each site taking one cast by hand (H) and another using hydrostatic casting (S). The process of casting, rectifying and modifying a diagnostic socket was timed in minutes. Socket comfort score (SCS) was assessed during static fitting of the diagnostic socket before (initial) and after (final) any modifications were made by the prosthetist. Difference scores for comfort and timing were calculated for each pair of casts within prosthetist. Bootstrapping methods were used to determine if the mean difference scores were significantly different from zero. Eighty participants with unilateral lower limb amputation were enrolled, with 75 completing the study. The initial SCS was significantly better in the transfemoral amputation group (TFA, n = 24) for the socket made from hand casting (H: 7.1 ± 1.9, S: 6.5 ± 2.2; p = 0.043). The final SCS was significantly better in the transtibial amputation group (TTA, n = 51) for the socket made from hydrostatic casting (H: 7.5 ± 2.0, S: 8.1 ± 1.3; p = 0.025). Total fabrication time for hydrostatic casting was significantly greater than hand casting (H: 42.1 ± 15.6, S: 48.0 ± 10.7; p = 0.001). It took significantly more time to cast (H: 10.6 ± 5.5, S: 23.7 ± 6.1; p < 0.0001) and significantly less time to rectify with hydrostatic casting (H: 23.4 ± 11.1, S: 16.6 ± 17.2; p < 0.0001). There was no difference between casting approaches for time to modify the diagnostic socket (H: 8.1 ± 7.5, S: 7.7 ± 6.6; p = 0.641). In individuals with both TTA and TFA results suggest that hydrostatic casting took more total time than hand casting to fabricate a diagnostic socket. While hand casting resulted in a significantly more comfortable socket initially for the TFA group, hydrostatic casting led to a more comfortable final socket for the TTA group.


  • Spatiotemporal gait parameters influencing functional mobility of people with lower limb amputation

    by Anat Kristal, Ignacio Gaunaurd, Neva Kirk-Sanchez, Steven Gard, Natali Clark, Emika Da Silva, Forrest Stieg, Robert Gailey

    Background: Walking speed is a measure of functional mobility that is relatively easy to quantify. In people with lower limb amputation, reduced walking speed has been linked with specific atypical spatiotemporal gait parameters. However, the influence of atypical spatiotemporal gait parameters on the walking speed of people with unilateral transtibial amputation (TTA) and transfemoral amputation (TFA) remains unclear. Objectives: To identify spatiotemporal gait parameters influencing walking speed of people with unilateral TTA or TFA. Study design: Cross-sectional. Methods: The 10-meter walk test (10mWT) was used to measure walking speed, and an instrumented walkway was used to record spatiotemporal gait parameters. Regression analyses were used to determine the best subset of spatiotemporal gait parameters that influence the walking speed of people with TTA and TFA. Results: The study included 43 people with TTA and 49 with TFA. In the TTA group, spatiotemporal gait parameters accounted for 65.5% of the variance in walking speed, with prosthetic single limb support accounting for 52.2%, prosthetic terminal double limb support accounting for 8.9%, and stride width accounting for 4.4%. In the TFA group, intact swing accounted for 46.7% of the variance in walking speed. There was no significant difference in walking speed between the TTA and the TFA groups ( p > 0.05). Conclusions: The study's results highlight specific spatiotemporal gait parameters that affect the walking speed of people with unilateral TTA and TFA. In addition, results suggest that walking speed over short distances is not confounded by amputation level (i.e., TTA and TFA).


  • Using a Simple Walking Model to Optimize Transfemoral Prostheses for Prosthetic Limb Stability—A Preliminary Study

    by Anna Pace, David Howard, Steven A. Gard, Matthew J. Major

    The interaction between the prescribed prosthetic knee and foot is critical to the safety of transfemoral prosthesis users primarily during the stance phase of the gait, when knee buckling can result in a fall. Nonetheless, there is still a need for standardized approaches to quantify the effects of prosthetic component interactions and associated mechanical function on user gait biomechanics. A numerical model was defined to simulate sagittal plane prosthetic limb stance based on a single inverted pendulum and predict effects of prosthetic knee alignment and foot stiffness on knee moment to identify optimal solutions. Model validation against laboratory gait data suggests it is appropriate to preliminary simulate prosthetic gait during single-limb support, when prosthetic knee stability may be most at risk given reliance on the prosthetic limb and proximal anatomy, but only for knees with flexion smaller than 4°. Model predictions identify a solution space containing those combinations of knee alignment and foot stiffness (via roll-over shape radius) guaranteeing knee stability in early and mid- single-limb support, whilst facilitating knee break at the end of it. Specifically, a posterior to in-line knee alignment should be combined with low to medium ankle-foot stiffness, whereas anterior knee alignments and rigid feet should likely be avoided. Clinicians can use these solution spaces to optimize transfemoral prostheses including knees with little to no change in stance flexion, ensuring the safety of users. Model prediction can further inform in-vivo investigations on commercial device interactions, providing evidence for future Clinical Practice Guidelines on transfemoral prostheses design.


  • Open Access

    Rehabilitation Is a Global Health Priority

    by Allen W Heinemann, Michael Feuerstein, Walter R Frontera, Steven A Gard, Leonard A Kaminsky, Stefano Negrini, Lorie Gage Richards, Catherine Vallée, Maria Zalm

    An abstract is unavailable. This article is available as a PDF only.

  • A 2nd-Order Model of the Vertical Impedance of the Locomotor System During Human Walking

    by Georgios A. Bertos, Dudley S. Childress, Steven A. Gard

    Objective: To design better shock absorbing prosthetic components, walking machines, or bionic legs, values and properties of the mechanical impedance of the locomotor system of able-bodied ambulators need to be determined. Methods: The representation of a simple 2 nd -order shock absorption component (i.e., effective body mass, $M_{e}$ , supported by a stiffness, ${k}$ , and damping, ${B}$ , in parallel) was incorporated into a previously proposed rocker-based inverted pendulum model of walking to more accurately model the impedance associated with human walking, including the effects of shock absorption. Using system identification techniques and quantitative gait analysis data from able-bodied subjects ( ${n}\,\,=$ 7), the properties and values of the mechanical impedance for each subject’s trial were determined. Results: It was determined that stiffness, ${k}$ , increased linearly with walking speed while damping, ${B}$ , increased with the square root of walking speed. Furthermore, the locomotor system behaves like an optimal underdamped mechanical system (i.e., damping ratio $\zeta $ of approximately 0.5–0.7). Conclusion: The locomotor system seems to behave like an optimal and adaptive low-pass filter in which the cutoff frequency is adjusted based on the locomotor’s cadence. It could be hypothesized that this occurs due to the principle of conservation of the passenger’s well-being: the fact that one of the locomotor’s functional responsibilities is to prevent higher frequency vibrations that are harmful for the musculoskeletal system of the passenger. Significance: This is a holistic, simplified, and accurate model of the vertical leg mechanical impedance (locomotor system) that establishes parameters during walking over a range of speeds. These results can be used for the scientific design of better shock absorption prosthetic components and lower-limb prostheses, management of shock absorption related gait pathologies, or the design of human-like walking machines and rehabilitation robots.


  • Effect of foot and ankle immobilization on able-bodied gait as a model to increase understanding about bilateral transtibial amputee gait

    by Antonia Nepomuceno, Matthew J Major, Rebecca Stine, Steven Gard

    The anatomical foot–ankle complex facilitates advancement of the stance limb through foot rockers and late-stance power generation during walking, but this mechanism is altered for persons with bilateral transtibial amputation when using passive prostheses. To study the effects of bilateral foot and ankle immobilization on able-bodied gait to serve as a model for understanding gait of persons with bilateral transtibial amputation and associated compensatory mechanisms. Comparative analysis. Nine able-bodied persons walked at self-selected slow, normal, and fast speeds. They performed trials unaltered and when fitted with bilateral foot and ankle–immobilizing casts. Data from 10 individuals with bilateral transtibial amputation walking at self-selected fast speeds were used for qualitative comparison. The average speeds for the able-bodied fast speed cast and normal speed no-cast trials were similar and were compared with bilateral transtibial amputation data. The able-bodied cast condition data more closely matched bilateral transtibial amputation data than the no-cast data. Ankle range-of-motion and power generation at pre-swing in the cast condition were markedly decreased, while trunk lateral flexion and transverse rotation range-of-motion and peak hip power generation increased. Results suggest that the absence of active ankle range-of-motion and power generation contributes to the development of characteristic compensatory gait mechanisms displayed by persons with bilateral transtibial amputation. This study helps to improve understanding of compensatory mechanisms resulting from reduced foot and ankle joint motion to inform lower limb prosthesis design and function for improving gait quality of individuals with bilateral transtibial amputation.


  • Open Access

    How a diverse research ecosystem has generated new rehabilitation technologies: Review of NIDILRR’s Rehabilitation Engineering Research Centers

    by David J. Reinkensmeyer, Sarah Blackstone, Cathy Bodine, John Brabyn, David Brienza, Kevin Caves, Frank DeRuyter, Edmund Durfee, Stefania Fatone, Geoff Fernie, et al.

    Over 50 million United States citizens (1 in 6 people in the US) have a developmental, acquired, or degenerative disability. The average US citizen can expect to live 20% of his or her life with a disability. Rehabilitation technologies play a major role in improving the quality of life for people with a disability, yet widespread and highly challenging needs remain. Within the US, a major effort aimed at the creation and evaluation of rehabilitation technology has been the Rehabilitation Engineering Research Centers (RERCs) sponsored by the National Institute on Disability, Independent Living, and Rehabilitation Research. As envisioned at their conception by a panel of the National Academy of Science in 1970, these centers were intended to take a “total approach to rehabilitation”, combining medicine, engineering, and related science, to improve the quality of life of individuals with a disability. Here, we review the scope, achievements, and ongoing projects of an unbiased sample of 19 currently active or recently terminated RERCs. Specifically, for each center, we briefly explain the needs it targets, summarize key historical advances, identify emerging innovations, and consider future directions. Our assessment from this review is that the RERC program indeed involves a multidisciplinary approach, with 36 professional fields involved, although 70% of research and development staff are in engineering fields, 23% in clinical fields, and only 7% in basic science fields; significantly, 11% of the professional staff have a disability related to their research. We observe that the RERC program has substantially diversified the scope of its work since the 1970’s, addressing more types of disabilities using more technologies, and, in particular, often now focusing on information technologies. RERC work also now often views users as integrated into an interdependent society through technologies that both people with and without disabilities co-use (such as the internet, wireless communication, and architecture). In addition, RERC research has evolved to view users as able at improving outcomes through learning, exercise, and plasticity (rather than being static), which can be optimally timed. We provide examples of rehabilitation technology innovation produced by the RERCs that illustrate this increasingly diversifying scope and evolving perspective. We conclude by discussing growth opportunities and possible future directions of the RERC program.