Shanshan Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shanshan Chen has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Benny Lo
Hamlyn Centre, Department of Surgery and Cancer, Imperial College London, London SW7 2AZ, UK
1 shared publication - Bernard F. Fuemmeler
Department of Family Medicine and Population Health, Virginia Commonwealth University, Richmond, USA
1 shared publication Bernard Fuemmeler
Department of Family Medicine Virginia Commonwealth University Richmond Virginia USA
1 shared publicationBin Ni
Department of Internal Medicine, Virginia Commonwealth University, Richmond, Virginia, United States of America
1 shared publication- Caitlin Eileen Martin
Institute for Drug and Alcohol Studies Virginia Commonwealth University Richmond Virginia USA
1 shared publication Cory Scott
Department of Kinesiology and Health Sciences, Virginia Commonwealth University, Richmond, USA
1 shared publication
Latest Publications
- Open Access
- 17 September 2024
- Published by Wiley in Journal of Sleep Research
- Vol. 34 (2) , e14331
Profiling the sleep architecture of ageing adults using a seven‐state continuous‐time Markov model
Summary: Sleep is a complex biological process regulated by networks of neurons and environmental factors. As one falls asleep, neurotransmitters from sleep–wake regulating neurones work in synergy to control the switching of different sleep states throughout the night. As sleep disorders or underlying neuropathology can manifest as irregular switching, analysing these patterns is crucial in sleep medicine and neuroscience. While hypnograms represent the switching of sleep states well, current analyses of hypnograms often rely on oversimplified temporal descriptive statistics (TDS, e.g., total time spent in a sleep state), which miss the opportunity to study the sleep state switching by overlooking the complex structures of hypnograms. In this paper, we propose analysing sleep hypnograms using a seven‐state continuous‐time Markov model (CTMM). This proposed model leverages the CTMM to depict the time‐varying sleep‐state transitions, and probes three types of insomnia by distinguishing three types of wake states. Fitting the proposed model to data from 2056 ageing adults in the Multi‐Ethnic Study of Atherosclerosis (MESA) Sleep study, we profiled sleep architectures in this population and identified the various associations between the sleep state transitions and demographic factors and subjective sleep questions. Ageing, sex, and race all show distinctive patterns of sleep state transitions. Furthermore, we also found that the perception of insomnia and restless sleep are significantly associated with critical transitions in the sleep architecture. By incorporating three wake states in a continuous‐time Markov model, our proposed method reveals interesting insights into the relationships between objective hypnogram data and subjective sleep quality assessments.
- 17 September 2024
- Published by Wiley in Journal of Sleep Research
- Vol. 34 (2) , e14331
Open AccessProfiling the sleep architecture of ageing adults using a seven‐state continuous‐time Markov model
Summary: Sleep is a complex biological process regulated by networks of neurons and environmental factors. As one falls asleep, neurotransmitters from sleep–wake regulating neurones work in synergy to control the switching of different sleep states throughout the night. As sleep disorders or underlying neuropathology can manifest as irregular switching, analysing these patterns is crucial in sleep medicine and neuroscience. While hypnograms represent the switching of sleep states well, current analyses of hypnograms often rely on oversimplified temporal descriptive statistics (TDS, e.g., total time spent in a sleep state), which miss the opportunity to study the sleep state switching by overlooking the complex structures of hypnograms. In this paper, we propose analysing sleep hypnograms using a seven‐state continuous‐time Markov model (CTMM). This proposed model leverages the CTMM to depict the time‐varying sleep‐state transitions, and probes three types of insomnia by distinguishing three types of wake states. Fitting the proposed model to data from 2056 ageing adults in the Multi‐Ethnic Study of Atherosclerosis (MESA) Sleep study, we profiled sleep architectures in this population and identified the various associations between the sleep state transitions and demographic factors and subjective sleep questions. Ageing, sex, and race all show distinctive patterns of sleep state transitions. Furthermore, we also found that the perception of insomnia and restless sleep are significantly associated with critical transitions in the sleep architecture. By incorporating three wake states in a continuous‐time Markov model, our proposed method reveals interesting insights into the relationships between objective hypnogram data and subjective sleep quality assessments.
- Open Access
- 29 May 2024
- Published by The Royal Society in Royal Society Open Science
- Vol. 11 (5) , 231468
Validating CircaCP: a generic sleep–wake cycle detection algorithm for unlabelled actigraphy data
Sleep–wake (SW) cycle detection is a key step for extracting temporal sleep metrics from actigraphy. Various supervised learning algorithms have been developed, yet their generalizability from sensor to sensor or study to study is questionable. In this paper, we detail and validate an unsupervised algorithm—CircaCP—for detecting SW cycles from actigraphy. It first uses a robust cosinor model to estimate circadian rhythm, then searches for a single change point (CP) within each circadian cycle. Using CircaCP, we estimated sleep/wake onset times (S/WOTs) from 2125 individuals’ data in the MESA sleep study and compared the estimated S/WOTs against self-reported S/WOT event markers, using Bland–Altman analysis as well as variance component analysis. On average, SOTs estimated by CircaCP were 3.6 min behind those reported by event markers, and WOTs by CircaCP were less than 1 min behind those reported by markers. These differences accounted for less than 0.2% variability in S/WOTs, considering other sources of between-subject variations. Rooted in first principles of human circadian rhythms, our algorithm transferred seamlessly from children’s hip-worn ActiGraph data to ageing adults’ wrist-worn Actiwatch data. The generalizability of our algorithm suggests that it can be widely applied to actigraphy collected by other sensors and studies.
- 29 May 2024
- Published by The Royal Society in Royal Society Open Science
- Vol. 11 (5) , 231468
Open AccessValidating CircaCP: a generic sleep–wake cycle detection algorithm for unlabelled actigraphy data
Sleep–wake (SW) cycle detection is a key step for extracting temporal sleep metrics from actigraphy. Various supervised learning algorithms have been developed, yet their generalizability from sensor to sensor or study to study is questionable. In this paper, we detail and validate an unsupervised algorithm—CircaCP—for detecting SW cycles from actigraphy. It first uses a robust cosinor model to estimate circadian rhythm, then searches for a single change point (CP) within each circadian cycle. Using CircaCP, we estimated sleep/wake onset times (S/WOTs) from 2125 individuals’ data in the MESA sleep study and compared the estimated S/WOTs against self-reported S/WOT event markers, using Bland–Altman analysis as well as variance component analysis. On average, SOTs estimated by CircaCP were 3.6 min behind those reported by event markers, and WOTs by CircaCP were less than 1 min behind those reported by markers. These differences accounted for less than 0.2% variability in S/WOTs, considering other sources of between-subject variations. Rooted in first principles of human circadian rhythms, our algorithm transferred seamlessly from children’s hip-worn ActiGraph data to ageing adults’ wrist-worn Actiwatch data. The generalizability of our algorithm suggests that it can be widely applied to actigraphy collected by other sensors and studies.
- Open Access
- 31 August 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-8
An appraisal of whole-room indirect calorimeters and a metabolic cart for measuring resting and active metabolic rates
Whole-room indirect calorimeters (WRICs) have traditionally been used for real-time resting metabolic rate (RMR) measurements, while metabolic rate (MR) during short-interval exercises has commonly been measured by metabolic carts (MCs). This study aims to investigate the feasibility of incorporating short-interval exercises into WRIC study protocols by comparing the performance of WRICs and an MC. We assessed the 40-min RMR of 15 subjects with 2-day repeats and the 10–15 min activity MR (AMR) of 14 subjects at three intensities, using a large WRIC, a small WRIC, and an MC. We evaluated the biases between the instruments and quantified sources of variation using variance component analysis. All three instruments showed good agreement for both RMR (maximum bias = 0.07 kcal/min) and AMR assessment (maximum bias = 0.53 kcal/min). Moreover, the majority of the variability was between-subject and between-intensity variation, whereas the types of instrument contributed only a small amount to total variation in RMR (2%) and AMR (0.2%) data. In Conclusion, the good reproducibility among the instruments indicates that they may be used interchangeably in well-designed studies. Overall, WRICs can serve as an accurate and versatile means of assessing MR, capable of integrating RMR and short-interval AMR assessments into a single protocol.
- 31 August 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-8
Open AccessAn appraisal of whole-room indirect calorimeters and a metabolic cart for measuring resting and active metabolic rates
Whole-room indirect calorimeters (WRICs) have traditionally been used for real-time resting metabolic rate (RMR) measurements, while metabolic rate (MR) during short-interval exercises has commonly been measured by metabolic carts (MCs). This study aims to investigate the feasibility of incorporating short-interval exercises into WRIC study protocols by comparing the performance of WRICs and an MC. We assessed the 40-min RMR of 15 subjects with 2-day repeats and the 10–15 min activity MR (AMR) of 14 subjects at three intensities, using a large WRIC, a small WRIC, and an MC. We evaluated the biases between the instruments and quantified sources of variation using variance component analysis. All three instruments showed good agreement for both RMR (maximum bias = 0.07 kcal/min) and AMR assessment (maximum bias = 0.53 kcal/min). Moreover, the majority of the variability was between-subject and between-intensity variation, whereas the types of instrument contributed only a small amount to total variation in RMR (2%) and AMR (0.2%) data. In Conclusion, the good reproducibility among the instruments indicates that they may be used interchangeably in well-designed studies. Overall, WRICs can serve as an accurate and versatile means of assessing MR, capable of integrating RMR and short-interval AMR assessments into a single protocol.
- Open Access
A Generic Algorithm for Sleep-Wake Cycle Detection using Unlabeled Actigraphy Data
One key component when analyzing actigraphy data for sleep studies is sleep-wake cycle detection. Most detection algorithms rely on accurate sleep diary labels to generate supervised classifiers, with parameters optimized for a particular dataset. However, once the actigraphy trackers are deployed in the field, labels for training models and validating detection accuracy are often not available. In this paper, we propose a generic, training-free algorithm to detect sleep-wake cycles from minute-by-minute actigraphy. Leveraging a robust nonlinear parametric model, our proposed method refines the detection region by searching for a single change point within bounded regions defined by the parametric model. Challenged by the absence of ground truth labels, we also propose an evaluation metric dedicated to this problem. Tested on week-long actigraphy from 112 children, the results show that the proposed algorithm improves on the baseline model consistently and significantly (p<3e-15). Moreover, focusing on the commonality in human circadian rhythm captured by actigraphy, the proposed method is generic to data collected by various actigraphy trackers, circumventing the laborious label collection step in developing customized classifiers for sleep detection.
Open AccessA Generic Algorithm for Sleep-Wake Cycle Detection using Unlabeled Actigraphy Data
One key component when analyzing actigraphy data for sleep studies is sleep-wake cycle detection. Most detection algorithms rely on accurate sleep diary labels to generate supervised classifiers, with parameters optimized for a particular dataset. However, once the actigraphy trackers are deployed in the field, labels for training models and validating detection accuracy are often not available. In this paper, we propose a generic, training-free algorithm to detect sleep-wake cycles from minute-by-minute actigraphy. Leveraging a robust nonlinear parametric model, our proposed method refines the detection region by searching for a single change point within bounded regions defined by the parametric model. Challenged by the absence of ground truth labels, we also propose an evaluation metric dedicated to this problem. Tested on week-long actigraphy from 112 children, the results show that the proposed algorithm improves on the baseline model consistently and significantly (p<3e-15). Moreover, focusing on the commonality in human circadian rhythm captured by actigraphy, the proposed method is generic to data collected by various actigraphy trackers, circumventing the laborious label collection step in developing customized classifiers for sleep detection.
- Open Access
- 24 April 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (4) , e0193467
Improving temporal accuracy of human metabolic chambers for dynamic metabolic studies
Metabolic chambers are powerful tools for assessing human energy expenditure, providing flexibility and comfort for the subjects in a near free-living environment. However, the flexibility offered by the large living room size creates challenges in the assessment of dynamic human metabolic signals—such as those generated during high-intensity interval training and short-term involuntary physical activities—with sufficient temporal accuracy. Therefore, this paper presents methods to improve the temporal accuracy of metabolic chambers. The proposed methods include 1) adopting a shortest possible step size, here one minute, to compute the finite derivative terms for the metabolic rate calculation, and 2) applying a robust noise reduction method—total variation denoising—to minimize the large noise generated by the short derivative term whilst preserving the transient edges of the dynamic metabolic signals. Validated against 24-hour gas infusion tests, the proposed method reconstructs dynamic metabolic signals with the best temporal accuracy among state-of-the-art approaches, achieving a root mean square error of 0.27 kcal/min (18.8 J/s), while maintaining a low cumulative error in 24-hour total energy expenditure of less than 45 kcal/day (188280 J/day). When applied to a human exercise session, the proposed methods also show the best performance in terms of recovering the dynamics of exercise energy expenditure. Overall, the proposed methods improve the temporal resolution of the chamber system, enabling metabolic studies involving dynamic signals such as short interval exercises to carry out the metabolic chambers.
- 24 April 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (4) , e0193467
Open AccessImproving temporal accuracy of human metabolic chambers for dynamic metabolic studies
Metabolic chambers are powerful tools for assessing human energy expenditure, providing flexibility and comfort for the subjects in a near free-living environment. However, the flexibility offered by the large living room size creates challenges in the assessment of dynamic human metabolic signals—such as those generated during high-intensity interval training and short-term involuntary physical activities—with sufficient temporal accuracy. Therefore, this paper presents methods to improve the temporal accuracy of metabolic chambers. The proposed methods include 1) adopting a shortest possible step size, here one minute, to compute the finite derivative terms for the metabolic rate calculation, and 2) applying a robust noise reduction method—total variation denoising—to minimize the large noise generated by the short derivative term whilst preserving the transient edges of the dynamic metabolic signals. Validated against 24-hour gas infusion tests, the proposed method reconstructs dynamic metabolic signals with the best temporal accuracy among state-of-the-art approaches, achieving a root mean square error of 0.27 kcal/min (18.8 J/s), while maintaining a low cumulative error in 24-hour total energy expenditure of less than 45 kcal/day (188280 J/day). When applied to a human exercise session, the proposed methods also show the best performance in terms of recovering the dynamics of exercise energy expenditure. Overall, the proposed methods improve the temporal resolution of the chamber system, enabling metabolic studies involving dynamic signals such as short interval exercises to carry out the metabolic chambers.
- Open Access
Quantifying Variation in Gait Features from Wearable Inertial Sensors Using Mixed Effects Models
The emerging technology of wearable inertial sensors has shown its advantages in collecting continuous longitudinal gait data outside laboratories. This freedom also presents challenges in collecting high-fidelity gait data. In the free-living environment, without constant supervision from researchers, sensor-based gait features are susceptible to variation from confounding factors such as gait speed and mounting uncertainty, which are challenging to control or estimate. This paper is one of the first attempts in the field to tackle such challenges using statistical modeling. By accepting the uncertainties and variation associated with wearable sensor-based gait data, we shift our efforts from detecting and correcting those variations to modeling them statistically. From gait data collected on one healthy, non-elderly subject during 48 full-factorial trials, we identified four major sources of variation, and quantified their impact on one gait outcome—range per cycle—using a random effects model and a fixed effects model. The methodology developed in this paper lays the groundwork for a statistical framework to account for sources of variation in wearable gait data, thus facilitating informative statistical inference for free-living gait analysis.
Open AccessQuantifying Variation in Gait Features from Wearable Inertial Sensors Using Mixed Effects Models
The emerging technology of wearable inertial sensors has shown its advantages in collecting continuous longitudinal gait data outside laboratories. This freedom also presents challenges in collecting high-fidelity gait data. In the free-living environment, without constant supervision from researchers, sensor-based gait features are susceptible to variation from confounding factors such as gait speed and mounting uncertainty, which are challenging to control or estimate. This paper is one of the first attempts in the field to tackle such challenges using statistical modeling. By accepting the uncertainties and variation associated with wearable sensor-based gait data, we shift our efforts from detecting and correcting those variations to modeling them statistically. From gait data collected on one healthy, non-elderly subject during 48 full-factorial trials, we identified four major sources of variation, and quantified their impact on one gait outcome—range per cycle—using a random effects model and a fixed effects model. The methodology developed in this paper lays the groundwork for a statistical framework to account for sources of variation in wearable gait data, thus facilitating informative statistical inference for free-living gait analysis.
- Top Cited PapersOpen Access
- 22 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 20 (6) , 1521-1537
Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
After decades of evolution, measuring instruments for quantitative gait analysis have become an important clinical tool for assessing pathologies manifested by gait abnormalities. However, such instruments tend to be expensive and require expert operation and maintenance besides their high cost, thus limiting them to only a small number of specialized centers. Consequently, gait analysis in most clinics today still relies on observation-based assessment. Recent advances in wearable sensors, especially inertial body sensors, have opened up a promising future for gait analysis. Not only can these sensors be more easily adopted in clinical diagnosis and treatment procedures than their current counterparts, but they can also monitor gait continuously outside clinics – hence providing seamless patient analysis from clinics to free-living environments. The purpose of this paper is to provide a systematic review of current techniques for quantitative gait analysis and to propose key metrics for evaluating the existing, as well as emerging methods for qualifying the gait features extracted from wearable sensors. It aims to highlight key advances in this rapidly evolving research field and outline potential future directions for both research and clinical applications.
- 22 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 20 (6) , 1521-1537
Top Cited PapersOpen AccessToward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
After decades of evolution, measuring instruments for quantitative gait analysis have become an important clinical tool for assessing pathologies manifested by gait abnormalities. However, such instruments tend to be expensive and require expert operation and maintenance besides their high cost, thus limiting them to only a small number of specialized centers. Consequently, gait analysis in most clinics today still relies on observation-based assessment. Recent advances in wearable sensors, especially inertial body sensors, have opened up a promising future for gait analysis. Not only can these sensors be more easily adopted in clinical diagnosis and treatment procedures than their current counterparts, but they can also monitor gait continuously outside clinics – hence providing seamless patient analysis from clinics to free-living environments. The purpose of this paper is to provide a systematic review of current techniques for quantitative gait analysis and to propose key metrics for evaluating the existing, as well as emerging methods for qualifying the gait features extracted from wearable sensors. It aims to highlight key advances in this rapidly evolving research field and outline potential future directions for both research and clinical applications.
- 1 January 2013
- Published by European Alliance for Innovation n.o.
- p. 185-188
Nonlinear Feature for Gait Speed Estimation using Inertial Sensors
Gait speed is an important feature in many health applications. To obtain this information, a machine-learning approach is often preferred to first principle modeling for its generality in dealing with systematic errors. In this approach, extracting predictive features is critical to the estimation accuracy. Therefore, identifying and extracting highly correlated features for gait speed estimation become the first important steps for the machine-learning framework. This paper proposes a novel nonlinear feature for gait speed estimation using shank-mounted inertial sensors. Rooted in analytic mechanics, this nonlinear feature captures the dynamics of angular position and angular velocity -- two interdependent variables for gait speed -- simultaneously by examining the area of the phase portrait. Among all the features extracted, this nonlinear feature was ranked as the most important by an automatic feature selection algorithm given its highest correlation with gait speed among all features evaluated, and it improves the accuracy for gait speed estimation in intra-subject cross validation compared to using commonly extracted linear features alone.
- 1 January 2013
- Published by European Alliance for Innovation n.o.
- p. 185-188
Nonlinear Feature for Gait Speed Estimation using Inertial Sensors
Gait speed is an important feature in many health applications. To obtain this information, a machine-learning approach is often preferred to first principle modeling for its generality in dealing with systematic errors. In this approach, extracting predictive features is critical to the estimation accuracy. Therefore, identifying and extracting highly correlated features for gait speed estimation become the first important steps for the machine-learning framework. This paper proposes a novel nonlinear feature for gait speed estimation using shank-mounted inertial sensors. Rooted in analytic mechanics, this nonlinear feature captures the dynamics of angular position and angular velocity -- two interdependent variables for gait speed -- simultaneously by examining the area of the phase portrait. Among all the features extracted, this nonlinear feature was ranked as the most important by an automatic feature selection algorithm given its highest correlation with gait speed among all features evaluated, and it improves the accuracy for gait speed estimation in intra-subject cross validation compared to using commonly extracted linear features alone.