Peter Šmeringai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peter Šmeringai has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Marcel Fedak
Department of Process Technique, Faculty of Manufacturing Technologies with a Seat in Presov, Technical University of Kosice, Bayerova 1, 080 01 Presov, Slovakia
9 shared publications - Miroslav Rimar
Department of Process Technique, Faculty of Manufacturing Technologies with a Seat in Presov, Technical University of Kosice, Bayerova 1, 080 01 Presov, Slovakia
9 shared publications - Andrii Kulikov
Faculty of Manufacturing Technologies with the Seat in Presov, Technical University of Kosice, Bayerova 1, 08001 Presov, Slovakia
4 shared publications Štefan Kuna
Mart System s.r.o.
3 shared publications- Anna Šmeringaiová
Faculty of Manufacturing Technologies, Technical University in Kosice, Sturova 31, 080 01 Presov, Slovakia
2 shared publications Michal Hatala
Department of Manufacturing Technologies, Faculty of Manufacturing Technologies, Technical University of Kosice with a Seat in Prešov, Sturova 31, 08001 Prešov, Slovakia
2 shared publications
Latest Publications
- 16 February 2019
- Published by Springer Nature
- p. 49-59
Operational Characteristics of Experimental Actuator with a Drive Based on the Antagonistic Pneumatic Artificial Muscles
- 16 February 2019
- Published by Springer Nature
- p. 49-59
Operational Characteristics of Experimental Actuator with a Drive Based on the Antagonistic Pneumatic Artificial Muscles
- 7 March 2018
- Published by MM Publishing, s.r.o. in MM Science Journal
- Vol. 2018 (01) , 2188-2191
STUDY OF GASEOUS FLOWS IN CLOSED AREA WITH FORCED VENTILATION
- 7 March 2018
- Published by MM Publishing, s.r.o. in MM Science Journal
- Vol. 2018 (01) , 2188-2191
STUDY OF GASEOUS FLOWS IN CLOSED AREA WITH FORCED VENTILATION
- Open Access
- 22 February 2017
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2017, 1-14
Analysis of Step Responses in Nonlinear Dynamic Systems Consisting of Antagonistic Involvement of Pneumatic Artificial Muscles
The paper describes a set of experimental measurements carried out on the experimental equipment with a drive based on pneumatic artificial muscles. Based on the analysis of the PAMS control systems issue in relation to the issue of a position control, a control algorithm has been designed and verified. The requirements of the control systems do not arise only from the condition of the desired positioning point rapid achievement, but also from the subsequent dynamics and accuracy repeatability. This algorithm enables an efficient way of stabilization of the actuator position in various dynamic conditions during the operation. It allows eliminating undesirable vibrations oscillating around the point of the required position and dampening them appropriately. The article describes a set of performed verification experimental measurements confirming the applicability in relation to the system that controls the position of the actuator utilizing the described algorithm. The algorithm application enables a positive influencing and optimization of the actuator positioning accuracy and a full-valued automation of its operation.
- 22 February 2017
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2017, 1-14
Open AccessAnalysis of Step Responses in Nonlinear Dynamic Systems Consisting of Antagonistic Involvement of Pneumatic Artificial Muscles
The paper describes a set of experimental measurements carried out on the experimental equipment with a drive based on pneumatic artificial muscles. Based on the analysis of the PAMS control systems issue in relation to the issue of a position control, a control algorithm has been designed and verified. The requirements of the control systems do not arise only from the condition of the desired positioning point rapid achievement, but also from the subsequent dynamics and accuracy repeatability. This algorithm enables an efficient way of stabilization of the actuator position in various dynamic conditions during the operation. It allows eliminating undesirable vibrations oscillating around the point of the required position and dampening them appropriately. The article describes a set of performed verification experimental measurements confirming the applicability in relation to the system that controls the position of the actuator utilizing the described algorithm. The algorithm application enables a positive influencing and optimization of the actuator positioning accuracy and a full-valued automation of its operation.
- 16 November 2016
- Published by MM Publishing, s.r.o. in MM Science Journal
- Vol. 2016 (5) , 1240-1243
TECHNOLOGY OF GASEOUS FUEL COMBUSTION RESPECT TO NOX FORMATION
- 16 November 2016
- Published by MM Publishing, s.r.o. in MM Science Journal
- Vol. 2016 (5) , 1240-1243
TECHNOLOGY OF GASEOUS FUEL COMBUSTION RESPECT TO NOX FORMATION
- 16 November 2016
- Published by MM Publishing, s.r.o. in MM Science Journal
- Vol. 2016 (05) , 1201-1204
DEPENDENCE OF HARDNESS OF CONTINUES DIE-CASTING PRODUCTS ON FE CONTENT
- 16 November 2016
- Published by MM Publishing, s.r.o. in MM Science Journal
- Vol. 2016 (05) , 1201-1204
DEPENDENCE OF HARDNESS OF CONTINUES DIE-CASTING PRODUCTS ON FE CONTENT
- 1 October 2015
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 18, 3-11
Alternatives for Real Time Positioning Control System in Mechatronic System with Pneumatic Artificial Muscles
This paper explains the design of real-time control system for control of drives containing the artificial muscles. Described is the design of hardware and software devices, as well as design of their involvement in the experimental device. In this paper are referred experimental measurements on the device, aimed at monitoring the change in observed characteristics caused by position changes in artificial muscles during their operation.
- 1 October 2015
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 18, 3-11
Alternatives for Real Time Positioning Control System in Mechatronic System with Pneumatic Artificial Muscles
This paper explains the design of real-time control system for control of drives containing the artificial muscles. Described is the design of hardware and software devices, as well as design of their involvement in the experimental device. In this paper are referred experimental measurements on the device, aimed at monitoring the change in observed characteristics caused by position changes in artificial muscles during their operation.
- 1 October 2015
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 669, 434-442
Dynamic Model of the Test Station for Gear Drives Dynamic Tests
The contribution deals with the issue of the experimental assessment of the dynamic behaviour of the gear drives. The objective is to design and to realize the experimental station for dynamic tests of gear drives in an accelerated mode. Described is the idea of the experimental station design, the procedure of creating its mathematical model and the model for computer simulation.
- 1 October 2015
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 669, 434-442
Dynamic Model of the Test Station for Gear Drives Dynamic Tests
The contribution deals with the issue of the experimental assessment of the dynamic behaviour of the gear drives. The objective is to design and to realize the experimental station for dynamic tests of gear drives in an accelerated mode. Described is the idea of the experimental station design, the procedure of creating its mathematical model and the model for computer simulation.
- 1 October 2015
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 669, 335-344
Real Time Pressure Control in Pneumatic Actuators
This paper explains the design of real-time control system for drives which use a pneumatic artificial muscles. Described is the design of hardware and software equipment, as well as design of these components involvement in the experimental facility with artificial muscles. In this paper are referred experimental measurements on the device aimed at monitoring the changes in observed PAMs characteristics caused by pressure changes in artificial muscles during their operation.
- 1 October 2015
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 669, 335-344
Real Time Pressure Control in Pneumatic Actuators
This paper explains the design of real-time control system for drives which use a pneumatic artificial muscles. Described is the design of hardware and software equipment, as well as design of these components involvement in the experimental facility with artificial muscles. In this paper are referred experimental measurements on the device aimed at monitoring the changes in observed PAMs characteristics caused by pressure changes in artificial muscles during their operation.
- 1 October 2015
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 669, 361-369
Technical and Software Equipment for the Real Time Positioning Control System in Mechatronic Systems with Pneumatic Artificial Muscles
This paper explains the design of real-time control system for control of drives containing the artificial muscles. Described is the design of devices hardware and software, as well as design of their involvement in the experimental device. In this paper are referred experimental measurements on the device, aimed at monitoring the change in observed characteristics caused by position changes in artificial muscles during their operation.
- 1 October 2015
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 669, 361-369
Technical and Software Equipment for the Real Time Positioning Control System in Mechatronic Systems with Pneumatic Artificial Muscles
This paper explains the design of real-time control system for control of drives containing the artificial muscles. Described is the design of devices hardware and software, as well as design of their involvement in the experimental device. In this paper are referred experimental measurements on the device, aimed at monitoring the change in observed characteristics caused by position changes in artificial muscles during their operation.
- Open Access
- 25 May 2015
- Published by Wiley in International Journal of Photoenergy
- Vol. 2015, 1-19
The Synergistic Effect of Thermal Collectors Rotation in relation to Their Energy Efficiency and Stagnation Compared with the Static Thermal System in the Conditions of Central Europe
The presented paper deals with the issue of the efficient use of solar energy potential gained from thermal panels via tracking the Sun’s trajectory. Based on long-term measurements of the selected parameters, the efficiency of the installed system in relation to the ecliptic was evaluated in the static regime as well as in a rotary regime. In the comparison of rotary and fixed system of the collectors the presented results show an increase of the effectiveness of rotary one during the period of the day. On closer view the increase is not constant. During the day it varies: the most significant increase is in the afternoon, while the time from 10:30 a.m. to 1:00 p.m. the effectiveness of both systems almost identical. The utilisation of the rotary system as a suitable instrument for the elimination of the system stagnation was also evaluated.
- 25 May 2015
- Published by Wiley in International Journal of Photoenergy
- Vol. 2015, 1-19
Open AccessThe Synergistic Effect of Thermal Collectors Rotation in relation to Their Energy Efficiency and Stagnation Compared with the Static Thermal System in the Conditions of Central Europe
The presented paper deals with the issue of the efficient use of solar energy potential gained from thermal panels via tracking the Sun’s trajectory. Based on long-term measurements of the selected parameters, the efficiency of the installed system in relation to the ecliptic was evaluated in the static regime as well as in a rotary regime. In the comparison of rotary and fixed system of the collectors the presented results show an increase of the effectiveness of rotary one during the period of the day. On closer view the increase is not constant. During the day it varies: the most significant increase is in the afternoon, while the time from 10:30 a.m. to 1:00 p.m. the effectiveness of both systems almost identical. The utilisation of the rotary system as a suitable instrument for the elimination of the system stagnation was also evaluated.