Matthias Malzacher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthias Malzacher has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Lothar R. Schad
Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
8 shared publications- Jorge Chacon-Caldera
Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
7 shared publications Mathias Davids
Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
2 shared publications- Nadia Paschke
Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
2 shared publications Ruomin Hu
Computer Assisted Clinical Medicine Medical Faculty Mannheim Heidelberg University Mannheim Germany
2 shared publicationsAlexander Fischer
Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
1 shared publication
Latest Publications
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 6 (1) , 146-152
Comparison of Time and Frequency Domain Solvers for Magnetic Resonance Coils at Different Field Strengths Using a Single Computational Platform
Rapid prototyping and safety assessments are essential in the modern development of radio frequency coils for magnetic resonance imaging. The use of 3D electromagnetic simulations can avoid expensive physical coil prototyping while providing quantities to determine local patient safety which is not measurable in vivo. Currently, 3D electromagnetic simulations are mostly solved on variations of two solver types, namely the time domain and the frequency domain solver. In this work, we compared these solvers and tested key simulation parameters using a single computational platform with state-of-the-art computational methods and computational human models. Our analysis included computational cost, B1+-field and power loss density for a range of common radio frequency setups used at different Larmor frequencies (field strengths, respectively) in magnetic resonance imaging systems. We found that a coarse mesh in a time solver has large unpredictable focal errors (>50%) due to partial volume artifacts while the frequency solver showed more linearity in the errors when reducing computational cost which could allow for more efficient simulations with reduced safety concerns. We expect our work to provide further insights into parameter and solver selection and contribute towards standardization in coil simulation in magnetic resonance imaging.
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 6 (1) , 146-152
Comparison of Time and Frequency Domain Solvers for Magnetic Resonance Coils at Different Field Strengths Using a Single Computational Platform
Rapid prototyping and safety assessments are essential in the modern development of radio frequency coils for magnetic resonance imaging. The use of 3D electromagnetic simulations can avoid expensive physical coil prototyping while providing quantities to determine local patient safety which is not measurable in vivo. Currently, 3D electromagnetic simulations are mostly solved on variations of two solver types, namely the time domain and the frequency domain solver. In this work, we compared these solvers and tested key simulation parameters using a single computational platform with state-of-the-art computational methods and computational human models. Our analysis included computational cost, B1+-field and power loss density for a range of common radio frequency setups used at different Larmor frequencies (field strengths, respectively) in magnetic resonance imaging systems. We found that a coarse mesh in a time solver has large unpredictable focal errors (>50%) due to partial volume artifacts while the frequency solver showed more linearity in the errors when reducing computational cost which could allow for more efficient simulations with reduced safety concerns. We expect our work to provide further insights into parameter and solver selection and contribute towards standardization in coil simulation in magnetic resonance imaging.
- 1 December 2019
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 29 (4) , 359-367
Feasibility study of a double resonant (1H/23Na) abdominal RF setup at 3 T
- 1 December 2019
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 29 (4) , 359-367
Feasibility study of a double resonant (1H/23Na) abdominal RF setup at 3 T
- 14 March 2019
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 59, 97-104
Feasibility study of a double resonant 8-channel 1H/ 8-channel 23Na receive-only head coil at 3 Tesla
- 14 March 2019
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 59, 97-104
Feasibility study of a double resonant 8-channel 1H/ 8-channel 23Na receive-only head coil at 3 Tesla
- 1 November 2018
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 53, 7-13
Evaluating the effects of receive-only arrays in specific absorption rate simulations at 3 and 7 T
- 1 November 2018
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 53, 7-13
Evaluating the effects of receive-only arrays in specific absorption rate simulations at 3 and 7 T
- 25 July 2018
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 53, 164-172
Evaluation of stacked resonators to enhance the performance of a surface receive-only array for prostate MRI at 3 Tesla
- 25 July 2018
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 53, 164-172
Evaluation of stacked resonators to enhance the performance of a surface receive-only array for prostate MRI at 3 Tesla
- Open Access
- 7 May 2018
- Published by MDPI AG in Journal of Imaging
- Vol. 4 (5) , 67
Radio Frequency Modeling of Receive Coil Arrays for Magnetic Resonance Imaging
The numerical calculation of the signal-to-noise ratio (SNR) of magnetic resonance imaging (MRI) coil arrays is a powerful tool in the development of new coil arrays. The proposed method describes a complete model that allows the calculation of the absolute SNR values of arbitrary coil arrays, including receiver chain components. A new method for the SNR calculation of radio frequency receive coil arrays for MRI is presented, making use of their magnetic transmit pattern and the S-parameters of the network. The S-parameters and fields are extracted from an electromagnetic field solver and are post-processed using our developed model to provide absolute SNR values. The model includes a theory for describing the noise of all components in the receiver chain and the noise figure of a pre-amplifier by a simple passive two-port network. To validate the model, two- and four-element receive coil arrays are investigated. The SNR of the examined arrays is calculated and compared to measurement results using imaging of a saline water phantom in a scanner. The predicted values of the model are in good agreement with the measured values. The proposed method can be used to predict the absolute SNR for any receive coil array by calculating the transmit pattern and the S-parameters of the network. Knowledge of the components of the receiver chain including pre-amplifiers leads to satisfactory results compared to measured values, which proves the method to be a useful tool in the development process of MRI receive coil arrays.- 7 May 2018
- Published by MDPI AG in Journal of Imaging
- Vol. 4 (5) , 67
Open AccessRadio Frequency Modeling of Receive Coil Arrays for Magnetic Resonance Imaging
The numerical calculation of the signal-to-noise ratio (SNR) of magnetic resonance imaging (MRI) coil arrays is a powerful tool in the development of new coil arrays. The proposed method describes a complete model that allows the calculation of the absolute SNR values of arbitrary coil arrays, including receiver chain components. A new method for the SNR calculation of radio frequency receive coil arrays for MRI is presented, making use of their magnetic transmit pattern and the S-parameters of the network. The S-parameters and fields are extracted from an electromagnetic field solver and are post-processed using our developed model to provide absolute SNR values. The model includes a theory for describing the noise of all components in the receiver chain and the noise figure of a pre-amplifier by a simple passive two-port network. To validate the model, two- and four-element receive coil arrays are investigated. The SNR of the examined arrays is calculated and compared to measurement results using imaging of a saline water phantom in a scanner. The predicted values of the model are in good agreement with the measured values. The proposed method can be used to predict the absolute SNR for any receive coil array by calculating the transmit pattern and the S-parameters of the network. Knowledge of the components of the receiver chain including pre-amplifiers leads to satisfactory results compared to measured values, which proves the method to be a useful tool in the development process of MRI receive coil arrays. - 1 April 2018
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 48B (2)
Reducing signal‐to‐noise ratio degradation due to coil coupling in a receiver array for 35Cl MRI at 9.4 T: A comparison of matching and decoupling strategies
Next to conventional magnetic resonance imaging (MRI), which utilizes hydrogen nuclei, other nuclei, so‐called X‐nuclei, are of increasing interest since they can provide additional diagnostic information. However, X‐nuclei MRI is challenging due to the lower Signal‐to‐Noise Ratio (SNR) compared to 1H (35Cl provides approximately 200 000 times lower SNR than 1H). In order to compete with this challenge, the use of high‐field strengths and optimized hardware is crucial. In this work, a transmit‐only receive‐only (TORO) system for 35Cl MRI at a preclinical 9.4 T scanner is presented, composed of a volumetric birdcage coil and a 3 channel Rx array. SNR degradation despite preamplifier decoupling can no longer be neglected since the resonance frequency of 35Cl is low. This paper will prove the SNR degradation due to the coil coupling of the receiver coils for this setup and evaluate three different approaches to mitigate the SNR degradation. The performance of the different approaches is evaluated via single channel and combined SNR maps using phantom measurements. Finally, the SNR maps acquired with the Rx array are compared to the SNR map acquired using the Birdcage coil as a reference.
- 1 April 2018
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 48B (2)
Reducing signal‐to‐noise ratio degradation due to coil coupling in a receiver array for 35Cl MRI at 9.4 T: A comparison of matching and decoupling strategies
Next to conventional magnetic resonance imaging (MRI), which utilizes hydrogen nuclei, other nuclei, so‐called X‐nuclei, are of increasing interest since they can provide additional diagnostic information. However, X‐nuclei MRI is challenging due to the lower Signal‐to‐Noise Ratio (SNR) compared to 1H (35Cl provides approximately 200 000 times lower SNR than 1H). In order to compete with this challenge, the use of high‐field strengths and optimized hardware is crucial. In this work, a transmit‐only receive‐only (TORO) system for 35Cl MRI at a preclinical 9.4 T scanner is presented, composed of a volumetric birdcage coil and a 3 channel Rx array. SNR degradation despite preamplifier decoupling can no longer be neglected since the resonance frequency of 35Cl is low. This paper will prove the SNR degradation due to the coil coupling of the receiver coils for this setup and evaluate three different approaches to mitigate the SNR degradation. The performance of the different approaches is evaluated via single channel and combined SNR maps using phantom measurements. Finally, the SNR maps acquired with the Rx array are compared to the SNR map acquired using the Birdcage coil as a reference.
- Open Access
- 13 July 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-14
Predicting Magnetostimulation Thresholds in the Peripheral Nervous System using Realistic Body Models
Rapid switching of applied magnetic fields in the kilohertz frequency range in the human body induces electric fields powerful enough to cause Peripheral Nerve Stimulation (PNS). PNS has become one of the main constraints on the use of high gradient fields for fast imaging with the latest MRI gradient technology. In recent MRI gradients, the applied fields are powerful enough that PNS limits their application in fast imaging sequences like echo-planar imaging. Application of Magnetic Particle Imaging (MPI) to humans is similarly PNS constrained. Despite its role as a major constraint, PNS considerations are only indirectly incorporated in the coil design process, mainly through using the size of the linear region as a proxy for PNS thresholds or by conducting human experiments after constructing coil prototypes. We present for the first time, a framework to simulate PNS thresholds for realistic coil geometries to directly address PNS in the design process. Our PNS model consists of an accurate body model for electromagnetic field simulations, an atlas of peripheral nerves, and a neurodynamic model to predict the nerve responses to imposed electric fields. With this model, we were able to reproduce measured PNS thresholds of two leg/arm solenoid coils with good agreement.
- 13 July 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-14
Open AccessPredicting Magnetostimulation Thresholds in the Peripheral Nervous System using Realistic Body Models
Rapid switching of applied magnetic fields in the kilohertz frequency range in the human body induces electric fields powerful enough to cause Peripheral Nerve Stimulation (PNS). PNS has become one of the main constraints on the use of high gradient fields for fast imaging with the latest MRI gradient technology. In recent MRI gradients, the applied fields are powerful enough that PNS limits their application in fast imaging sequences like echo-planar imaging. Application of Magnetic Particle Imaging (MPI) to humans is similarly PNS constrained. Despite its role as a major constraint, PNS considerations are only indirectly incorporated in the coil design process, mainly through using the size of the linear region as a proxy for PNS thresholds or by conducting human experiments after constructing coil prototypes. We present for the first time, a framework to simulate PNS thresholds for realistic coil geometries to directly address PNS in the design process. Our PNS model consists of an accurate body model for electromagnetic field simulations, an atlas of peripheral nerves, and a neurodynamic model to predict the nerve responses to imposed electric fields. With this model, we were able to reproduce measured PNS thresholds of two leg/arm solenoid coils with good agreement.
- Open Access
- 21 June 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 3943
Tracking protein function with sodium multi quantum spectroscopy in a 3D-tissue culture based on microcavity arrays
The aim of this study was to observe the effects of strophanthin induced inhibition of the Na-/K-ATPase in liver cells using a magnetic resonance (MR) compatible bioreactor. A microcavity array with a high density three-dimensional cell culture served as a functional magnetic resonance imaging (MRI) phantom for sodium multi quantum (MQ) spectroscopy. Direct contrast enhanced (DCE) MRI revealed the homogenous distribution of biochemical substances inside the bioreactor. NMR experiments using advanced bioreactors have advantages with respect to having full control over a variety of physiological parameters such as temperature, gas composition and fluid flow. Simultaneous detection of single quantum (SQ) and triple quantum (TQ) MR signals improves accuracy and was achieved by application of a pulse sequence with a time proportional phase increment (TQTPPI). The time course of the Na-/K-ATPase inhibition in the cell culture was demonstrated by the corresponding alterations of sodium TQ/SQ MR signals.
- 21 June 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 3943
Open AccessTracking protein function with sodium multi quantum spectroscopy in a 3D-tissue culture based on microcavity arrays
The aim of this study was to observe the effects of strophanthin induced inhibition of the Na-/K-ATPase in liver cells using a magnetic resonance (MR) compatible bioreactor. A microcavity array with a high density three-dimensional cell culture served as a functional magnetic resonance imaging (MRI) phantom for sodium multi quantum (MQ) spectroscopy. Direct contrast enhanced (DCE) MRI revealed the homogenous distribution of biochemical substances inside the bioreactor. NMR experiments using advanced bioreactors have advantages with respect to having full control over a variety of physiological parameters such as temperature, gas composition and fluid flow. Simultaneous detection of single quantum (SQ) and triple quantum (TQ) MR signals improves accuracy and was achieved by application of a pulse sequence with a time proportional phase increment (TQTPPI). The time course of the Na-/K-ATPase inhibition in the cell culture was demonstrated by the corresponding alterations of sodium TQ/SQ MR signals.
- 1 March 2016
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 26 (1) , 95-100
Sodium-23 MRI of whole spine at 3 Tesla using a 5-channel receive-only phased-array and a whole-body transmit resonator
- 1 March 2016
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 26 (1) , 95-100
Sodium-23 MRI of whole spine at 3 Tesla using a 5-channel receive-only phased-array and a whole-body transmit resonator