I-Jung Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
I-Jung Lee has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Bor-Shing Lin
Department of Computer Science and Information Engineering, National Taipei University, New Taipei City, Taiwan
17 shared publications - Chih-Wei Peng
Taipei Medical University
5 shared publications - Jean-Lon Chen
Department of Physical Medicine & Rehabilitation, Chang Gung Memorial Hospital at Linkou, College of Medicine, Chang Gung University, Guishan District, Taoyuan City 33343, Taiwan
3 shared publications Pei-Chi Hsiao
Department of Physical Medicine and Rehabilitation, Chi-Mei Medical Center, Tainan, Taiwan
3 shared publications- Alexandre Calado
Department of Electronic Engineering, University of Rome Tor Vergata Rome, Italy
2 shared publications - Chueh-Ho Lin
Master program in Long-Term Care, College of Nursing, Taipei Medical University, Taipei, Taiwan
2 shared publications
Latest Publications
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24  (2) , 2162-2171
Quasi-Static Measurement Performances of Flex-Sensor-Based and Inertial- Measurement -Unit-Based Sensory Gloves
Sensory gloves convert hand postures and movements of fingers into electric signals. Different technologies can be adopted to achieve this conversion, and different approaches can be used to evaluate its effectiveness. In this study, we adopted two types of sensory gloves based on two types of sensors, namely the Resistive Flex Sensor (RFS) and the Inertial Measurement Unit (IMU). We evaluated the conversion effectiveness in terms of repeatability, reproducibility and reliability of quasi-static measurements. In particular, to take into account the nonlinear characteristics of sensors, we propose an improvement of the usually adopted measurement test protocol used for assessing the performance of sensory gloves. According to our results, the two sensory gloves have similar reliability. However, the IMU-based glove provides better repeatability, and the RFS-based glove provides better reproducibility. Overall, the average range ± standard deviation and intraclass correlation coefficient of the RFS-based glove were 5.66° ± 2.22° and 0.73 ± 0.17, respectively, and those of the IMU-based glove were 7.80° ± 2.47° and 0.76 ± 0.14, respectively. All in all, the novelty of this work concerns the comparison of two types of sensory gloves in terms of quasi-static measurement reproducibility and reliability and the improvement of an existing standard protocol for sensory glove assessment aimed at providing a more comprehensive analysis.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24  (2) , 2162-2171
Quasi-Static Measurement Performances of Flex-Sensor-Based and Inertial- Measurement -Unit-Based Sensory Gloves
Sensory gloves convert hand postures and movements of fingers into electric signals. Different technologies can be adopted to achieve this conversion, and different approaches can be used to evaluate its effectiveness. In this study, we adopted two types of sensory gloves based on two types of sensors, namely the Resistive Flex Sensor (RFS) and the Inertial Measurement Unit (IMU). We evaluated the conversion effectiveness in terms of repeatability, reproducibility and reliability of quasi-static measurements. In particular, to take into account the nonlinear characteristics of sensors, we propose an improvement of the usually adopted measurement test protocol used for assessing the performance of sensory gloves. According to our results, the two sensory gloves have similar reliability. However, the IMU-based glove provides better repeatability, and the RFS-based glove provides better reproducibility. Overall, the average range ± standard deviation and intraclass correlation coefficient of the RFS-based glove were 5.66° ± 2.22° and 0.73 ± 0.17, respectively, and those of the IMU-based glove were 7.80° ± 2.47° and 0.76 ± 0.14, respectively. All in all, the novelty of this work concerns the comparison of two types of sensory gloves in terms of quasi-static measurement reproducibility and reliability and the improvement of an existing standard protocol for sensory glove assessment aimed at providing a more comprehensive analysis.
- Open Access
- 30 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 143649-143656
Biomechanical Evaluation of Fingers Repetitive Voluntary Tasks in Chronic Stroke Survivors
A chronic stroke affects hand mobility limiting the normal functioning of the finger joints. The voluntary tasks with a repetitive motion can identify the limitation in the range of motion (ROM) to enhance the hand functioning of stroke survivors. Therefore, we compared two voluntary tasks fast ball squeezing (FBS) and slow ball squeezing (SBS), and analyzed the variability of these tasks for finger pressure and ROM in chronic stroke survivors. An experimental study with 22 healthy and 39 chronic stroke participants was conducted. All of them wore an upper limb motion capture device (UMCD) to record the active (AROM) of finger joints during FBS and SBS tasks for 20 repetitions. The data were analyzed into the joint angle and pressure to compare these tasks and their variability. While comparing the FBS and SBS tasks, left-side pressure and both sides’ ROM attained the level of significance (p < 0.05) except for right-side pressure in healthy controls. However, for stroke participants, right-side pressure and left-side ROM differed significantly. The finger pressure and ROM for the right vs. left side are changed significantly for both tasks in healthy control and stroke survivors except for SBS pressure in the stroke group (p = 0.119). The right FBS and SBS are more sensitive to changes in finger pressure and left SBS for ROM in healthy control while in stroke survivors, left FBS and SBS pressure and ROM are sensitive. The variability for pressure is higher and easy to detect as compared to ROM.
- 30 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 143649-143656
Open AccessBiomechanical Evaluation of Fingers Repetitive Voluntary Tasks in Chronic Stroke Survivors
A chronic stroke affects hand mobility limiting the normal functioning of the finger joints. The voluntary tasks with a repetitive motion can identify the limitation in the range of motion (ROM) to enhance the hand functioning of stroke survivors. Therefore, we compared two voluntary tasks fast ball squeezing (FBS) and slow ball squeezing (SBS), and analyzed the variability of these tasks for finger pressure and ROM in chronic stroke survivors. An experimental study with 22 healthy and 39 chronic stroke participants was conducted. All of them wore an upper limb motion capture device (UMCD) to record the active (AROM) of finger joints during FBS and SBS tasks for 20 repetitions. The data were analyzed into the joint angle and pressure to compare these tasks and their variability. While comparing the FBS and SBS tasks, left-side pressure and both sides’ ROM attained the level of significance (p < 0.05) except for right-side pressure in healthy controls. However, for stroke participants, right-side pressure and left-side ROM differed significantly. The finger pressure and ROM for the right vs. left side are changed significantly for both tasks in healthy control and stroke survivors except for SBS pressure in the stroke group (p = 0.119). The right FBS and SBS are more sensitive to changes in finger pressure and left SBS for ROM in healthy control while in stroke survivors, left FBS and SBS pressure and ROM are sensitive. The variability for pressure is higher and easy to detect as compared to ROM.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24  (1) , 920-930
Analysis of Gait Data Based on Deep Learning to Predict Multiple Balance Scale Scores
Unbalanced walking is increasingly common among older adults. Therefore, routinely assessing the balance of older adults is crucial. The traditional method of assessing balance uses scales, requires supervision of a physical therapist (PT), and is time-consuming. Therefore, the present study proposes a deep learning model architecture that combines a convolutional neural network (CNN) and a long short-term memory network model (LSTM) to predict the scores of three scales, namely the Berg balance scale (BBS), timed up and go (TUG), and single-leg stance (SLS). The gait data of 15 m of walking were collected from seven inertial measurement units (IMUs) and input into the CNN–LSTM model for evaluation. The BBS and TUG only require the participants to wear two IMUs on the left and right thighs, respectively for accurate predictions. The mean absolute errors (MAEs) of predicting the scores of the BBS and TUG are 1.2562 and 1.4016 s, respectively. However, the MAE of score predictions of SLS is higher than that of the BBS and TUG, indicating that gait data cannot be used for assessing SLS. Moreover, participants only wear one IMU on the right calf for BBS and TUG evaluations, which yield MAEs of 1.4334 and 1.5229 s, respectively. The proposed system can quickly and accurately predict the scores of the BBS and TUG. The proposed model can assist PTs with making clinical decisions.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24  (1) , 920-930
Analysis of Gait Data Based on Deep Learning to Predict Multiple Balance Scale Scores
Unbalanced walking is increasingly common among older adults. Therefore, routinely assessing the balance of older adults is crucial. The traditional method of assessing balance uses scales, requires supervision of a physical therapist (PT), and is time-consuming. Therefore, the present study proposes a deep learning model architecture that combines a convolutional neural network (CNN) and a long short-term memory network model (LSTM) to predict the scores of three scales, namely the Berg balance scale (BBS), timed up and go (TUG), and single-leg stance (SLS). The gait data of 15 m of walking were collected from seven inertial measurement units (IMUs) and input into the CNN–LSTM model for evaluation. The BBS and TUG only require the participants to wear two IMUs on the left and right thighs, respectively for accurate predictions. The mean absolute errors (MAEs) of predicting the scores of the BBS and TUG are 1.2562 and 1.4016 s, respectively. However, the MAE of score predictions of SLS is higher than that of the BBS and TUG, indicating that gait data cannot be used for assessing SLS. Moreover, participants only wear one IMU on the right calf for BBS and TUG evaluations, which yield MAEs of 1.4334 and 1.5229 s, respectively. The proposed system can quickly and accurately predict the scores of the BBS and TUG. The proposed model can assist PTs with making clinical decisions.
- Open Access
- 1 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10  (11) , 1273
Prediction of Spasticity through Upper Limb Active Range of Motion in Stroke Survivors: A Generalized Estimating Equation Model
Background: We aim to study the association between spasticity and active range of motion (ROM) during four repetitive functional tasks such as cone stacking (CS), fast flexion–extension (FFE), fast ball squeezing (FBS), and slow ball squeezing (SBS), and predicted spasticity models. Methods: An experimental study with control and stroke groups was conducted in a Medical Center. A total of sixty-four participants, including healthy control (n = 22; average age (years) = 54.68 ± 9.63; male/female = 12/10) and chronic stroke survivors (n = 42; average age = 56.83 ± 11.74; male/female = 32/10) were recruited. We employed a previously developed smart glove device mounted with multiple inertial measurement unit (IMU) sensors on the upper limbs of healthy and chronic stroke individuals. The recorded ROMs were used to predict subjective spasticity through generalized estimating equations (GEE) for the affected side. Results: The models have significant (p ≤ 0.05 *) prediction of spasticity for the elbow, thumb, index, middle, ring, and little fingers. Overall, during SBS and FFE activities, the maximum number of upper limb joints attained the greater average ROMs. For large joints, the elbow during CS and the wrist during FFE have the highest average ROMs, but smaller joints and the wrist have covered the highest average ROMs during FFE, FBS, and SBS activities. Conclusions: Thus, it is concluded that CS can be used for spasticity assessment of the elbow, FFE for the wrist, and SBS, FFE, and FBS activities for the thumb and finger joints in chronic stroke survivors.
- 1 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10  (11) , 1273
Open AccessPrediction of Spasticity through Upper Limb Active Range of Motion in Stroke Survivors: A Generalized Estimating Equation Model
Background: We aim to study the association between spasticity and active range of motion (ROM) during four repetitive functional tasks such as cone stacking (CS), fast flexion–extension (FFE), fast ball squeezing (FBS), and slow ball squeezing (SBS), and predicted spasticity models. Methods: An experimental study with control and stroke groups was conducted in a Medical Center. A total of sixty-four participants, including healthy control (n = 22; average age (years) = 54.68 ± 9.63; male/female = 12/10) and chronic stroke survivors (n = 42; average age = 56.83 ± 11.74; male/female = 32/10) were recruited. We employed a previously developed smart glove device mounted with multiple inertial measurement unit (IMU) sensors on the upper limbs of healthy and chronic stroke individuals. The recorded ROMs were used to predict subjective spasticity through generalized estimating equations (GEE) for the affected side. Results: The models have significant (p ≤ 0.05 *) prediction of spasticity for the elbow, thumb, index, middle, ring, and little fingers. Overall, during SBS and FFE activities, the maximum number of upper limb joints attained the greater average ROMs. For large joints, the elbow during CS and the wrist during FFE have the highest average ROMs, but smaller joints and the wrist have covered the highest average ROMs during FFE, FBS, and SBS activities. Conclusions: Thus, it is concluded that CS can be used for spasticity assessment of the elbow, FFE for the wrist, and SBS, FFE, and FBS activities for the thumb and finger joints in chronic stroke survivors.
- 14 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 8  (1) , 255-263
Adaptive Indoor People-Counting System Based on Edge AI Computing
Since the outbreak of COVID-19 in 2019, people counting in confined spaces has become essential for controlling the flow of people and reducing viral spread. Many people-counting systems use a fisheye lens to achieve a wide viewing range. However, the images captured with a fisheye lens can have different sizes and deformations due to different camera heights, which consequently affects the accuracy of people counting. In this study, a Raspberry Pi 4 development board attached to a fisheye lens was used to construct an edge computing platform for people counting by using artificial intelligence. A modified You Only Look Once (YOLO) model, which has three output layers and a spatial pyramid pooling module, is proposed to recognize people in images captured at various heights. For efficiently running this deep learning model on the proposed edge computing platform, a TensorFlow Lite framework was used to reduce the model size. The final experimental results indicated that the mean average error and mean squared error of the modified tiny version of the YOLO v4 model were 0.249 and 0.292, respectively, and the detection speed of the platform was 2 frames per second. The results indicate that the proposed edge computing platform can efficiently and accurately count the number of people. Because the proposed system uses edge computing, it can effectively solve personal privacy and transmission bandwidth problems.
- 14 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 8  (1) , 255-263
Adaptive Indoor People-Counting System Based on Edge AI Computing
Since the outbreak of COVID-19 in 2019, people counting in confined spaces has become essential for controlling the flow of people and reducing viral spread. Many people-counting systems use a fisheye lens to achieve a wide viewing range. However, the images captured with a fisheye lens can have different sizes and deformations due to different camera heights, which consequently affects the accuracy of people counting. In this study, a Raspberry Pi 4 development board attached to a fisheye lens was used to construct an edge computing platform for people counting by using artificial intelligence. A modified You Only Look Once (YOLO) model, which has three output layers and a spatial pyramid pooling module, is proposed to recognize people in images captured at various heights. For efficiently running this deep learning model on the proposed edge computing platform, a TensorFlow Lite framework was used to reduce the model size. The final experimental results indicated that the mean average error and mean squared error of the modified tiny version of the YOLO v4 model were 0.249 and 0.292, respectively, and the detection speed of the platform was 2 frames per second. The results indicate that the proposed edge computing platform can efficiently and accurately count the number of people. Because the proposed system uses edge computing, it can effectively solve personal privacy and transmission bandwidth problems.
- 28 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27  (7) , 3549-3558
System Based on Artificial Intelligence Edge Computing for Detecting Bedside Falls and Sleep Posture
Bedside falls and pressure ulcers are crucial issues in geriatric care. Although many bedside monitoring systems have been proposed, they are limited by the computational complexity of their algorithms. Moreover, most of the data collected by the sensors of these systems must be transmitted to a back-end server for calculation. With an increase in the demand for the Internet of Things, problems such as higher cost of bandwidth and overload of server computing are faced when using the aforementioned systems. To reduce the server workload, certain computing tasks must be offloaded from cloud servers to edge computing platforms. In this study, a bedside monitoring system based on neuromorphic computing hardware was developed to detect bedside falls and sleeping posture. The artificial intelligence neural network executed on the back-end server was simplified and used on an edge computing platform. An integer 8-bit-precision neural network model was deployed on the edge computing platform to process the thermal image captured by the thermopile array sensing element to conduct sleep posture classification and bed position detection. The bounding box of the bed was then converted into the features for posture classification correction to correct the posture. In an experimental evaluation, the accuracy rate, inferencing speed, and power consumption of the developed system were 94.56%, 5.28 frames per second, and 1.5 W, respectively. All the calculations of the developed system are conducted on an edge computing platform, and the developed system only transmits fall events to the back-end server through Wi-Fi and protects user privacy.
- 28 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27  (7) , 3549-3558
System Based on Artificial Intelligence Edge Computing for Detecting Bedside Falls and Sleep Posture
Bedside falls and pressure ulcers are crucial issues in geriatric care. Although many bedside monitoring systems have been proposed, they are limited by the computational complexity of their algorithms. Moreover, most of the data collected by the sensors of these systems must be transmitted to a back-end server for calculation. With an increase in the demand for the Internet of Things, problems such as higher cost of bandwidth and overload of server computing are faced when using the aforementioned systems. To reduce the server workload, certain computing tasks must be offloaded from cloud servers to edge computing platforms. In this study, a bedside monitoring system based on neuromorphic computing hardware was developed to detect bedside falls and sleeping posture. The artificial intelligence neural network executed on the back-end server was simplified and used on an edge computing platform. An integer 8-bit-precision neural network model was deployed on the edge computing platform to process the thermal image captured by the thermopile array sensing element to conduct sleep posture classification and bed position detection. The bounding box of the bed was then converted into the features for posture classification correction to correct the posture. In an experimental evaluation, the accuracy rate, inferencing speed, and power consumption of the developed system were 94.56%, 5.28 frames per second, and 1.5 W, respectively. All the calculations of the developed system are conducted on an edge computing platform, and the developed system only transmits fall events to the back-end server through Wi-Fi and protects user privacy.
- 6 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72  (00189456) , 1-10
Dynamic Measurement Assessments of Sensory Gloves Based on Resistive Flex Sensors and Inertial Measurement Units
Sensory gloves are devices capable of measuring finger movements and are useful in numerous applications, many of which require real-time data acquisition. However, the procedures explored in the literature to assess measurement repeatability and reliability mainly rely on static or quasi-static conditions. To overcome this limitation, here we propose a testing procedure for assessing measurements under dynamic conditions (slow, medium, and rapid finger joint movements). To this aim, we used two sensory gloves, one based on resistive flex sensors (RFSs) and another based on inertial measurement units (IMUs) – as two of the most adopted types. Our study demonstrated the feasibility of measuring dynamic finger movements and the differences in dynamic measurement repeatability and reliability between RFS- and IMU-based gloves when considering the angles (in degrees) of each finger joint. The RFS-based glove scored with an average range ± standard deviation (SD) of 6.84 ± 2.77°, and an intraclass correlation coefficient (ICC) of 0.77 ± 0.14, whereas the IMU-based glove scored with an average range of 8.49 ± 2.72°, and an ICC of 0.75 ± 0.14. Both gloves exhibited better repeatability and reliability at the slowest speed, with the RFS-based glove having an higher repeatability than the IMU-based one ( p < 0.001). Moreover, when compared to previous studies, the results (in terms of reliability and repeatability) here obtained under dynamic conditions are comparable to those obtained under static or quasi-static conditions. In summary, our results indicate that both proposed sensory gloves are suitable for most applications that require dynamic interactions.
- 6 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72  (00189456) , 1-10
Dynamic Measurement Assessments of Sensory Gloves Based on Resistive Flex Sensors and Inertial Measurement Units
Sensory gloves are devices capable of measuring finger movements and are useful in numerous applications, many of which require real-time data acquisition. However, the procedures explored in the literature to assess measurement repeatability and reliability mainly rely on static or quasi-static conditions. To overcome this limitation, here we propose a testing procedure for assessing measurements under dynamic conditions (slow, medium, and rapid finger joint movements). To this aim, we used two sensory gloves, one based on resistive flex sensors (RFSs) and another based on inertial measurement units (IMUs) – as two of the most adopted types. Our study demonstrated the feasibility of measuring dynamic finger movements and the differences in dynamic measurement repeatability and reliability between RFS- and IMU-based gloves when considering the angles (in degrees) of each finger joint. The RFS-based glove scored with an average range ± standard deviation (SD) of 6.84 ± 2.77°, and an intraclass correlation coefficient (ICC) of 0.77 ± 0.14, whereas the IMU-based glove scored with an average range of 8.49 ± 2.72°, and an ICC of 0.75 ± 0.14. Both gloves exhibited better repeatability and reliability at the slowest speed, with the RFS-based glove having an higher repeatability than the IMU-based one ( p < 0.001). Moreover, when compared to previous studies, the results (in terms of reliability and repeatability) here obtained under dynamic conditions are comparable to those obtained under static or quasi-static conditions. In summary, our results indicate that both proposed sensory gloves are suitable for most applications that require dynamic interactions.
- 11 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28  (2) , 742-752
AI-Based Automatic System for Assessing Upper-Limb Spasticity of Patients With Stroke Through Voluntary Movement
Spasticity is a common complication for patients with stroke, but only few studies investigate the relation between spasticity and voluntary movement. This study proposed a novel automatic system for assessing the severity of spasticity (SS) of four upper-limb joints, including the elbow, wrist, thumb, and fingers, through voluntary movements. A wearable system which combined 19 inertial measurement units and a pressure ball was proposed to collect the kinematic and force information when the participants perform four tasks, namely cone stacking (CS), fast flexion and extension (FFE), slow ball squeezing (SBS), and fast ball squeezing (FBS). Several time and frequency domain features were extracted from the collected data, and two feature selection approaches based on recursive feature elimination were adopted to select the most influential features. The selected features were input into five machine learning techniques for assessing the SS for each joint. The results indicated that using CS task to assess the SS of elbow and fingers and using FBS task to assess the SS of thumb and wrist can reach the highest weighted-average F1-score. Furthermore, the study also concluded that FBS is the optimal task for assessing all the four upper-limb joints. The overall result shown that the proposed automatic system can assess four upper-limb joints through voluntary movements accurately, which is a breakthrough of finding the relation between spasticity and voluntary movement.
- 11 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28  (2) , 742-752
AI-Based Automatic System for Assessing Upper-Limb Spasticity of Patients With Stroke Through Voluntary Movement
Spasticity is a common complication for patients with stroke, but only few studies investigate the relation between spasticity and voluntary movement. This study proposed a novel automatic system for assessing the severity of spasticity (SS) of four upper-limb joints, including the elbow, wrist, thumb, and fingers, through voluntary movements. A wearable system which combined 19 inertial measurement units and a pressure ball was proposed to collect the kinematic and force information when the participants perform four tasks, namely cone stacking (CS), fast flexion and extension (FFE), slow ball squeezing (SBS), and fast ball squeezing (FBS). Several time and frequency domain features were extracted from the collected data, and two feature selection approaches based on recursive feature elimination were adopted to select the most influential features. The selected features were input into five machine learning techniques for assessing the SS for each joint. The results indicated that using CS task to assess the SS of elbow and fingers and using FBS task to assess the SS of thumb and wrist can reach the highest weighted-average F1-score. Furthermore, the study also concluded that FBS is the optimal task for assessing all the four upper-limb joints. The overall result shown that the proposed automatic system can assess four upper-limb joints through voluntary movements accurately, which is a breakthrough of finding the relation between spasticity and voluntary movement.
- Open Access
Design of a Multi-Sensor System for Exploring the Relation between Finger Spasticity and Voluntary Movement in Patients with Stroke
A novel wearable multi-sensor data glove system is developed to explore the relation between finger spasticity and voluntary movement in patients with stroke. Many stroke patients suffer from finger spasticity, which is detrimental to their manual dexterity. Diagnosing and assessing the degrees of spasticity require neurological testing performed by trained professionals to estimate finger spasticity scores via the modified Ashworth scale (MAS). The proposed system offers an objective, quantitative solution to assess the finger spasticity of patients with stroke and complements the manual neurological test. In this work, the hardware and software components of this system are described. By requiring patients to perform five designated tasks, biomechanical measurements including linear and angular speed, acceleration, and pressure at every finger joint and upper limb are recorded, making up more than 1000 features for each task. We conducted a preliminary clinical test with 14 subjects using this system. Statistical analysis is performed on the acquired measurements to identify a small subset of features that are most likely to discriminate a healthy patient from patients suffering from finger spasticity. This encouraging result validates the feasibility of this proposed system to quantitatively and objectively assess finger spasticity.
Open AccessDesign of a Multi-Sensor System for Exploring the Relation between Finger Spasticity and Voluntary Movement in Patients with Stroke
A novel wearable multi-sensor data glove system is developed to explore the relation between finger spasticity and voluntary movement in patients with stroke. Many stroke patients suffer from finger spasticity, which is detrimental to their manual dexterity. Diagnosing and assessing the degrees of spasticity require neurological testing performed by trained professionals to estimate finger spasticity scores via the modified Ashworth scale (MAS). The proposed system offers an objective, quantitative solution to assess the finger spasticity of patients with stroke and complements the manual neurological test. In this work, the hardware and software components of this system are described. By requiring patients to perform five designated tasks, biomechanical measurements including linear and angular speed, acceleration, and pressure at every finger joint and upper limb are recorded, making up more than 1000 features for each task. We conducted a preliminary clinical test with 14 subjects using this system. Statistical analysis is performed on the acquired measurements to identify a small subset of features that are most likely to discriminate a healthy patient from patients suffering from finger spasticity. This encouraging result validates the feasibility of this proposed system to quantitatively and objectively assess finger spasticity.
- Open Access
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30  (15344320) , 2682-2691
Development of a Smartphone-Based mHealth Platform for Telerehabilitation
Telerehabilitation is becoming increasingly valuable as a method for expanding medical services. The smartphone-based mHealth platform (SMPT) has been developed to provide high-quality remote rehabilitation through a smartphone and inertial measurement units. The SMPT uses smartphone as a main platform with connection to medical backend server to provide telerehabilitation. Patients would be referred to therapists to receive a tutorial of exercise technique prior to conducting their home exercise. Once patients begin their home exercises, they can report any problems instantly through the SMPT. The medical staff can adjust the exercise program according to patient feedback and the data collected by the SMPT. After completing the exercise program, patients visit their clinician for re-evaluation. A Service User Technology Acceptability Questionnaire from both medical professional and public perspective revealed a high level of agreement on enhanced care, increased accessibility, and satisfaction and a moderate level of agreement on the use of this platform as a substitute for traditional rehabilitation. Concerns about privacy and discomfort were low in the medical professional and public groups. Concerns about care personnel were also significantly different between the two groups. The SMPT is a promising system for providing telerehabilitation as an adjunct to traditional rehabilitation, which may result in improved outcomes compared with those achieved when using traditional rehabilitation alone.
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30  (15344320) , 2682-2691
Open AccessDevelopment of a Smartphone-Based mHealth Platform for Telerehabilitation
Telerehabilitation is becoming increasingly valuable as a method for expanding medical services. The smartphone-based mHealth platform (SMPT) has been developed to provide high-quality remote rehabilitation through a smartphone and inertial measurement units. The SMPT uses smartphone as a main platform with connection to medical backend server to provide telerehabilitation. Patients would be referred to therapists to receive a tutorial of exercise technique prior to conducting their home exercise. Once patients begin their home exercises, they can report any problems instantly through the SMPT. The medical staff can adjust the exercise program according to patient feedback and the data collected by the SMPT. After completing the exercise program, patients visit their clinician for re-evaluation. A Service User Technology Acceptability Questionnaire from both medical professional and public perspective revealed a high level of agreement on enhanced care, increased accessibility, and satisfaction and a moderate level of agreement on the use of this platform as a substitute for traditional rehabilitation. Concerns about privacy and discomfort were low in the medical professional and public groups. Concerns about care personnel were also significantly different between the two groups. The SMPT is a promising system for providing telerehabilitation as an adjunct to traditional rehabilitation, which may result in improved outcomes compared with those achieved when using traditional rehabilitation alone.