KVKartik Mangudi Varadarajan

Kartik Mangudi Varadarajan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kartik Mangudi Varadarajan has a total of 71 co-authors. Here are the top co-authors by number of shared publications:

  • Orhun K. Muratoglu

    <!--2--> Harris Orthopaedics Laboratory, Department of Orthopaedic Surgery Massachusetts General Hospital 55 Fruit Street, GRJ‐12‐1223 02214 Boston MA USA

    8 shared publications
  • Alireza Borjali

    <!--2--> Harris Orthopaedics Laboratory, Department of Orthopaedic Surgery Massachusetts General Hospital 55 Fruit Street, GRJ‐12‐1223 02214 Boston MA USA

    5 shared publications
  • Henrik Malchau

    Harris Orthopedics Laboratory, Massachusetts General Hospital, Boston, MA, USA; Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden

    5 shared publications
  • Antonia F. Chen

    Department of Orthopaedic Surgery Brigham and Women's Hospital Harvard Medical School Boston MA USA

    4 shared publications
  • Mohammad A. Morid

    Department of Information Systems and Analytics Santa Clara University Leavey School of Business Santa Clara CA USA

    4 shared publications
  • Alireza Borjali

    Harris Orthopaedics Laboratory Department of Orthopaedic Surgery Massachusetts General Hospital 55 Fruit St. GRJ 1121B 02114 Boston MA USA

    3 shared publications

Latest Publications

  • Sex and Height Impact Tibial Tuberosity to Trochlear Groove Distance Thresholds for Malalignment on Magnetic Resonance Imaging When Comparing Knees With Patellar Instability Versus Age‐ and Sex‐Matched Controls

    by Varun Nukala, Alisha Sodhi, Isha Tushar Wadhavkar, Dharsini Rangaswamy, Maria Velasquez‐Hammerle, Kartik Mangudi Varadrajan, Miho Jean Tanaka

    Purpose: To identify magnetic resonance imaging (MRI)‐based thresholds for measurements of malalignment and assess their ability to identify knees with patellar instability, while evaluating the impact of patient sex and height on these thresholds. Methods: A retrospective analysis was conducted to identify patients with symptomatic patellar instability and compare them with age‐ and sex‐ matched controls, defined as patients with meniscus tears without patellofemoral pathology. Tibial tuberosity to trochlear groove (TTTG) and tibial tuberosity‐posterior cruciate ligament (TT‐PCL) distances were measured on axial knee MRI. Receiver operating characteristic curves were calculated, and an area under the curve greater than 0.7 was considered a good diagnostic test. Youden's J statistic was used to establish diagnostic thresholds. Subgroup analysis was performed based on sex and height. Results: The study included 240 patients (64% female; age: 27 ± 9 years). Area under the curve was 0.75 (0.69, 0.81) for TTTG distance, but below 0.7 for TT‐PCL distance. Cutoff values for TTTG distance identifying patellar instability were 13.7 mm and 14.7 mm in female patients < and >= 165.1 cm, respectively. In male patients, cutoff values were 16.1 mm and 20.1 mm for male patients < and >= 177.8 cm, respectively. TTTG distance had good diagnostic accuracy in both female patients (0.78 (0.7, 0.85)) and male patients (0.7 (0.57, 0.82)), with greater predictive ability in male patients below (0.79 (0.61, 0.94)) versus above (0.56 (0.39, 0.72)) the median height and similar efficacy among female patients below (0.76 (0.64, 0.86)) and above (0.77 (0.64, 0.88)) the median height. Conclusions: TTTG distance measurements on MRI showed that threshold values for patellar instability were 16.1 mm vs 20.1 mm in male patients below and above the median height, and in female patients were 13.7 mm vs 14.7 mm for those below and above the median height, respectively. These differences highlight a need for incorporating patient‐specific factors when using these thresholds in clinical decision‐making. Level of Evidence: Level IV, retrospective comparative case series.


  • The Ultrasound-Assisted Patellar Glide Test: A Novel Examination Method for Quantifying Patellar Instability

    by Miho J. Tanaka, Nikitha Crasta, Maria V. Velasquez Hammerle, Mark P. Cote, Ashwin N. Babu, Kartik Mangudi Varadarajan

    Background: Patellofemoral instability is a difficult problem to assess because of its dynamic nature, which is not easily quantified using physical examination techniques. This study aimed to describe and evaluate a novel examination method using stress ultrasonography to quantify patellar instability. The secondary aim was to assess the relationship of stress ultrasonography measurements with clinical and morphologic risk factors for patellar instability. Methods: Knees with symptomatic patellar instability underwent the ultrasound-assisted patellar glide test. In this test, the patella was translated laterally from its resting position during ultrasound visualization until an endpoint was reached. The medial patellofemoral distance (MPFD) was used to quantify the gap between the medial boundary of the patella and the trochlea, and the difference in MPFD between the resting (unloaded) and loaded conditions was defined as the delta MPFD. Measurements were compared with those in asymptomatic contralateral knees of patients with unilateral instability, asymptomatic knees after patellar stabilization surgery, and control knees. Regression analyses assessed for relationships of MPFD with morphological and clinical risk factors. Receiver operating characteristic (ROC) curve analysis assessed the ability of stress ultrasonography measurements to discriminate between knees with and without symptomatic patellar instability. Results: Four hundred and seventy-seven knees in 277 patients were included in this study; 173 of the knees had patellar instability (patient age, 24 ± 8 years; 72% female). Delta MPFD was 3 times greater in knees with patellar instability (median, 3.3 mm [95% confidence interval, 3.1 to 3.4 mm]) than in the contralateral asymptomatic (1.1 mm [0.9 to 1.3 mm]), postoperative (1.0 mm [0.8 to 1.2 mm]), and control knees (1.4 mm [1.1 to 1.6 mm]). ROC analysis demonstrated an optimal threshold value for delta MPFD of 2.0 mm, which had an area under the curve (AUC) of 0.97 (0.94 to 0.99), demonstrating excellent discrimination in identifying knees with patellar instability. No relationships of clinical or morphologic risk factors with delta MPFD were found. Conclusions: A delta MPFD of ≥2 mm on the ultrasound-assisted patellar glide test had an AUC of 0.97 for identifying knees with symptomatic patellar instability, indicating excellent discriminatory ability. Additional studies utilizing this method are recommended to standardize and quantify assessments of patellar instability. Level of Evidence: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.

  • Open Access

    Normative Grip Strength Reference Values for the Squegg® Smart Dynamometer and Hand Grip Trainer

    by Kartik Mangudi Varadarajan, Ajinkya Agnihotri, Saket Gunjan, Sunanda Verma, Winnie Tsui, Gabriella Francis

    Introduction: Grip strength measurement is crucial for assessing hand dysfunction and health status. Weakgrip strength is linked to various health issues and reduced quality of life, particularly in older adults. Traditional analog assessment methods pose challenges, including limited accessibility and technological constraints. The Squegg® Smart Dynamometer offers a solution by providing a user-friendly device with Bluetooth connectivity, combined with a mobile application, for remote monitoring and training of grip strength. Studies have shown its reliability and validity compared to the gold standard Jamar dynamometer. This study aims to establish normative reference values for Squegg grip strength across different age groups and compare them with existing literature.Methods: De-identified data from users performing self-guided grip strength assessments were utilizedfor the study. Each evaluation comprised three trials, with users instructed to follow standardized procedures via the Squegg Core application. Users also had ability to repeat trials if they so desired. Data filtering excluded users with missing or outlier data, resulting in grip strength data from 502 users being included in final analysis. A qualitative comparison of Squegg maximal grip strength values with literature involved screening 352 studies, with 14 selected for final comparison based on predefined criteria.Results: Analysis of 502 individuals' Squegg grip strength data revealed statistically significant effects of age, sex, and hand dominance (p ≤ 0.0038). Grip strength decreased with age, especially after 40-50 years, with females exhibiting ~26% lower strength than males across all ages. Additionally, a slight difference (~5-6%) was noted between dominant and non-dominant sides. Qualitative comparison to 14 studies showed Squegg grip strength trends aligning with those from literature, particularly for females, with values for males being slightly lower.Conclusion: This study presents normative values for maximal grip strength using the Squegg® Smart Dynamometer, which align with trends observed for other devices. Females exhibited lower maximal grip strength than males, with strength declining quadratically with age for both sexes. These findings, coupled with prior validation studies, support the Squegg® as a reliable tool for assessing hand impairment severity and tracking rehabilitation progress.


  • Open Access

    Comparing machine learning algorithms for non-invasive detection and classification of failure in piezoresistive bone cement via electrical impedance tomography

    by L. Keiderling, J. Rosendorf, C. E. Owens, K. M. Varadarajan, A. J. Hart, J. Schwab, T. N. Tallman, H. Ghaednia

    At an estimated cost of $8 billion annually in the United States, revision surgeries to total joint replacements represent a substantial financial burden to the health care system and a tremendous mental and physical burden on patients and their caretakers. Fixation failures, such as implant loosening, wear, and mechanical instability of the poly(methyl methacrylate) (PMMA) cement, which bonds the implant to the bone, are the main causes of long-term implant failure. Early and accurate diagnosis of cement failure is critical for developing novel therapeutic strategies and reducing the high risk of a misjudged revision. Unfortunately, prevailing imaging modalities, notably plain radiographs, struggle to detect the precursors of implant failure and are often interpreted incorrectly. Our prior work has shown that the modification of PMMA bone cement with low concentrations of conductive fillers makes it piezoresistive and therefore self-sensing. When combined with a conductivity imaging modality such as electrical impedance tomography (EIT), it is possible to monitor load transfer across the PMMA using cost-effective, physiologically benign, non-contact, and real-time electrical measurements. Despite the ability of EIT for monitoring load transfer across self-sensing PMMA bone cement, it is unable to accurately characterize failure mechanisms. Overcoming this challenge is critical to the success of this technology in practice. Therefore, we herein expand upon our previous results by integrating machine learning techniques with EIT for cement condition characterization with the goal of establishing the feasibility of even off-the-shelf machine learning algorithms to address this important problem. We survey a wide variety of different machine learning algorithms for application to this problem, including neural networks on voltage readings of an EIT phantom for tracking the spatial position of a sample, specifying defect orientation within a sample, and classifying defect types, including cracks and delaminations. In addition, we explore the utilization of principal component analysis (PCA) for pre-treating impedance signals in each of these problems. Within the tested algorithms, our results show clear advantages of neural networks, support vector machines, and K-nearest neighbor algorithms for interpreting EIT signals. We also show that PCA is an effective addition to machine learning. These preliminary results demonstrate that the combination of smart materials, EIT, and machine learning may be a powerful instrumentation tool for diagnosing the origin and evolution of mechanical failure in joint replacements.


  • Defining and predicting radiographic knee osteoarthritis progression: a systematic review of findings from the osteoarthritis initiative

    by Peter Y. Joo, Alireza Borjali, Antonia F. Chen, Orhun K. Muratoglu, Kartik M. Varadarajan

    Purpose: The purposes of this systematic review were to (1) identify the commonly used definitions of radiographic KOA progression, (2) summarize the important associative risk factors for disease progression based on findings from the OAI study and (3) summarize findings from radiographic KOA progression prediction modeling studies regarding the characterization of progression and outcomes.Methods: A systematic review was performed by conducting a literature search of definitions, risk factors and predictive models for radiographic KOA progression that utilized data from the OAI database. Radiographic progression was further characterized into “accelerated KOA” and “typical progression,” as defined by included studies.Results: Of 314 studies identified, 41 studies were included in the present review. Twenty‐eight (28) studies analyzed risk factors associated with KOA progression, and 13 studies created or validated prediction models or risk calculators for progression. Kellgren–Lawrence (KL) grade based on radiographs was most commonly used to characterize KOA progression (50%), followed by joint space width (JSW) narrowing (32%) generally over 48 months. Risk factors with the highest odds ratios (OR) for progression included periarticular bone mineral density (OR 10.40), any knee injury within 1 year (OR 9.22) and baseline bone mineral lesions (OR 7.92). Nine prediction modeling studies utilized both clinical and structural risk factors to inform their models, and combined models outperformed purely clinical or structural models.Conclusion: The cumulative evidence suggests that combinations of structural and clinical risk factors may be able to predict radiographic KOA progression, particularly in patients with accelerated progression. Clinically relevant and feasible prediction models and risk calculators may provide valuable decision‐making support when caring for patients at risk of KOA progression, although standardization in modeling and variable identification does not yet exist.


  • Top Cited Papers
    Open Access

    Assessing the utility of deep neural networks in predicting postoperative surgical complications: a retrospective study

    by Alexander Bonde, Kartik M Varadarajan, Nicholas Bonde, Anders Troelsen, Orhun K Muratoglu, Henrik Malchau, Anthony D Yang, Hasan Alam, Martin Sillesen


  • Comparing the performance of a deep convolutional neural network with orthopedic surgeons on the identification of total hip prosthesis design from plain radiographs

    by Alireza Borjali, Antonia F. Chen, Hany S. Bedair, Christopher M. Melnic, Orhun K. Muratoglu, Mohammad A. Morid, Kartik M. Varadarajan

    Purpose: A crucial step in the preoperative planning for a revision total hip replacement (THR) surgery is the accurate identification of the failed implant design, especially if one or more well‐fixed/functioning components are to be retained. Manual identification of the implant design from preoperative radiographic images can be time‐consuming and inaccurate, which can ultimately lead to increased operating room time, more complex surgery, and increased healthcare costs.Method: In this study, we present a novel approach to identifying THR femoral implants' design from plain radiographs using a convolutional neural network (CNN). We evaluated a total of 402 radiographs of nine different THR implant designs including, Accolade II (130 radiographs), Corail (89 radiographs), M/L Taper (31 radiographs), Summit (31 radiographs), Anthology (26 radiographs), Versys (26 radiographs), S‐ROM (24 radiographs), Taperloc Standard Offset (24 radiographs), and Taperloc High Offset (21 radiographs). We implemented a transfer learning approach and adopted a DenseNet‐201 CNN architecture by replacing the final classifier with nine fully connected neurons. Furthermore, we used saliency maps to explain the CNN decision‐making process by visualizing the most important pixels in a given radiograph on the CNN's outcome. We also compared the CNN's performance with three board‐certified and fellowship‐trained orthopedic surgeons.Results: The CNN achieved the same or higher performance than at least one of the surgeons in identifying eight of nine THR implant designs and underperformed all of the surgeons in identifying one THR implant design (Anthology). Overall, the CNN achieved a lower Cohen's kappa (0.78) than surgeon 1 (1.00), the same Cohen's kappa as surgeon 2 (0.78), and a slightly higher Cohen's kappa than surgeon 3 (0.76) in identifying all the nine THR implant designs. Furthermore, the saliency maps showed that the CNN generally focused on each implant's unique design features to make a decision. Regarding the time spent performing the implant identification, the CNN accomplished this task in ~0.06 s per radiograph. The surgeon's identification time varied based on the method they utilized. When using their personal experience to identify the THR implant design, they spent negligible time. However, the identification time increased to an average of 8.4 min (standard deviation 6.1 min) per radiograph when they used another identification method (online search, consulting with the orthopedic company representative, and using image atlas), which occurred in about 17% of cases in the test subset (40 radiographs).Conclusions: CNNs such as the one developed in this study can be used to automatically identify the design of a failed THR femoral implant preoperatively in just a fraction of a second, saving time and in some cases improving identification accuracy.


  • Open Access

    Is Machine Learning Able to Detect and Classify Failure in Piezoresistive Bone Cement Based on Electrical Signals?

    by Hamid Ghaednia, Crystal E. Owens, Lily E. Keiderling, Kartik M. Varadarajan, A. John Hart, Joseph H. Schwab, Tyler T. Tallman

    At an estimated cost of $8 billion annually in the United States, revision surgeries to total joint replacements represent a substantial financial burden to the health care system. Fixation failures, such as implant loosening, wear, and mechanical instability of the poly(methyl methacrylate) (PMMA) cement, which bonds the implant to the bone, are the main causes of long-term implant failure. Early and accurate diagnosis of cement failure is critical for developing novel therapeutic strategies and reducing the high risk of a misjudged revision. Unfortunately, prevailing imaging modalities, notably plain radiographs, struggle to detect the precursors of implant failure and are often interpreted incorrectly. Our prior work has shown that the modification of PMMA bone cement with low concentrations of conductive fillers makes it piezoresistive and therefore self-sensing such that when combined with a conductivity imaging modality, such as electrical impedance tomography (EIT), it is possible to monitor load transfer across the PMMA using cost-effective, physiologically benign, and real-time electrical measurements. Herein, we expand upon these results by integrating machine learning techniques with EIT. We survey different machine learning algorithms and principal component analysis for application to this problem, including neural networks on voltage readings of an EIT phantom for tracking position of a sample, specifying defect location, and classifying defect types. Our results show advantage of neural network with more than 91.9 %, 95.5 %, and 98 % accuracy in interpreting EIT signals for location tracking, specifying defect location, and defect classification respectively. These preliminary results show that the combination of smart materials, EIT, and machine learning may be a powerful tool for diagnosing the origin and evolution of failure in joint replacement.