Johnathon D. Gard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Johnathon D. Gard has a total of 332 co-authors. Here are the top co-authors by number of shared publications:
- Douglas A. Bennett
National Institute of Standards and Technology
25 shared publications - Daniel R. Schmidt
National Institute of Standards and Technology
16 shared publications - Daniel S. Swetz
National Institute of Standards and Technology
15 shared publications - Joel N. Ullom
National Institute of Standards and Technology
12 shared publications - Kelsey M. Morgan
National Institute of Standards and Technology, Boulder, CO 80305, USA
12 shared publications - William Bertrand Doriese
National Institute of Standards and Technology
12 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
A 3 K Testbed to Screen Superconducting Circuits Based on a Commercial Probe Card With 140 Contacts
The NIST Quantum Sensors Division has developed a novel cryogenic testbed to qualify the two-dimensional superconducting quantum interference device (SQUID) time division multiplexer (TDM) devices that will provide front-end readout of the transition-edge-sensor detector array in the Xray Integral Field Unit (X-IFU) imaging spectrometer onboard NewAthena. This screening system uses a custom probe card with 140 tungsten-cantilever probe tips to connect to the device under test. Probing instead of wirebonding is required to enable subsequent bump bonding of TDM chips to X-IFU carrier wafers. It also allows testing of wafers before dicing, which allows some fabrication steps to occur after testing, including potential defect repair. The system is able to accommodate up to 150 mm wafers but is currently being used to test circuits on 76.5mm (‘3 inch’) wafers. The probe card is aligned and lowered to contact the DUT while at room temperature, so the system does not need or allow cold mechanical motion or cold optical access. The system is cooled by a commercial, two-stage, Gifford-McMahon cryomechanical cooler. Cooling to 3 K is achieved in less than 12 hours and the acquisition of a full set of test vectors takes less than an hour. Including re-warming to room temperature, the full test cycle can be run on a 48-hour cadence from one device to the next. With tens of test cycles successfully completed, this system has proven to be robust, reliable, and efficient.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
Open AccessA 3 K Testbed to Screen Superconducting Circuits Based on a Commercial Probe Card With 140 Contacts
The NIST Quantum Sensors Division has developed a novel cryogenic testbed to qualify the two-dimensional superconducting quantum interference device (SQUID) time division multiplexer (TDM) devices that will provide front-end readout of the transition-edge-sensor detector array in the Xray Integral Field Unit (X-IFU) imaging spectrometer onboard NewAthena. This screening system uses a custom probe card with 140 tungsten-cantilever probe tips to connect to the device under test. Probing instead of wirebonding is required to enable subsequent bump bonding of TDM chips to X-IFU carrier wafers. It also allows testing of wafers before dicing, which allows some fabrication steps to occur after testing, including potential defect repair. The system is able to accommodate up to 150 mm wafers but is currently being used to test circuits on 76.5mm (‘3 inch’) wafers. The probe card is aligned and lowered to contact the DUT while at room temperature, so the system does not need or allow cold mechanical motion or cold optical access. The system is cooled by a commercial, two-stage, Gifford-McMahon cryomechanical cooler. Cooling to 3 K is achieved in less than 12 hours and the acquisition of a full set of test vectors takes less than an hour. Including re-warming to room temperature, the full test cycle can be run on a 48-hour cadence from one device to the next. With tens of test cycles successfully completed, this system has proven to be robust, reliable, and efficient.
- Open Access
- 1 June 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (6)
A superconducting transition edge sensor array for synchrotron soft x-ray emission spectroscopies of low-dimensional and impurity-level concentration systems
We present a new instrument for soft x-ray absorption and emission spectroscopy based on the latest generation of transition edge sensor array optimized for soft x-ray detection, built on microwave superconducting quantum interference device multiplexing readout, and cooled with a dilution refrigerator. Its extreme collecting efficiency enables spectroscopy measurements on dilute systems. It also enables shorter acquisition time and large energy-range spectra. We describe the design and operation of the spectrometer and characterize its performance in terms of energy resolution, photon collecting efficiency, and stability. A resolution of 0.7–1.8 eV in the energy range 260–900 eV with a high detection rate of up to 10 000 photons per second across the array is achieved with minimal performance degradation. In addition, the use of the dilution refrigerator to cool the detector results in a robust and stable energy calibration over time. The spectrometer is attached to a dedicated ultra-high vacuum sample chamber equipped with a fully motorized sample cryostat for experiments at temperatures between 10 and 300 K, multi-sample mounting, and electric field-gated devices. The spectrometer-sample chamber is installed at a beamline providing full polarization control. We demonstrate the capabilities of the setup using two representative examples of XES on extremely low-concentration systems, namely monolayer hexagonal boron nitride and the K3[Fe(CN)6] molecular system at sub-millimolar concentration.
- 1 June 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (6)
Open AccessA superconducting transition edge sensor array for synchrotron soft x-ray emission spectroscopies of low-dimensional and impurity-level concentration systems
We present a new instrument for soft x-ray absorption and emission spectroscopy based on the latest generation of transition edge sensor array optimized for soft x-ray detection, built on microwave superconducting quantum interference device multiplexing readout, and cooled with a dilution refrigerator. Its extreme collecting efficiency enables spectroscopy measurements on dilute systems. It also enables shorter acquisition time and large energy-range spectra. We describe the design and operation of the spectrometer and characterize its performance in terms of energy resolution, photon collecting efficiency, and stability. A resolution of 0.7–1.8 eV in the energy range 260–900 eV with a high detection rate of up to 10 000 photons per second across the array is achieved with minimal performance degradation. In addition, the use of the dilution refrigerator to cool the detector results in a robust and stable energy calibration over time. The spectrometer is attached to a dedicated ultra-high vacuum sample chamber equipped with a fully motorized sample cryostat for experiments at temperatures between 10 and 300 K, multi-sample mounting, and electric field-gated devices. The spectrometer-sample chamber is installed at a beamline providing full polarization control. We demonstrate the capabilities of the setup using two representative examples of XES on extremely low-concentration systems, namely monolayer hexagonal boron nitride and the K3[Fe(CN)6] molecular system at sub-millimolar concentration.
- 1 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (11) , 113001
Measured and theoretical K α x-ray emission linewidths of U, Np, and Pu
We present measurements of the Kα_{1} and Kα_{2} natural x-ray linewidths of uranium, neptunium, and plutonium (Z=92, 93, 94) obtained using a superconducting transition-edge sensor microcalorimeter array. The relative uncertainties range from 0.5% to 1.5%, improving upon previous values by factors ranging from 3 to 8. These refined linewidths reduce systematic errors in gamma-ray spectroscopy assays of Pu-bearing materials, where Kα x-rays overlap with diagnostic gamma lines. We also present multiconfiguration Dirac-Fock calculations of the Kα linewidths for U, Np, and Pu, providing a benchmark for theory and experiment. These calculations reveal a discrepancy between ab initio theory and experiment possible to observe only with the improved experimental accuracy achieved in this work.
- 1 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (11) , 113001
Measured and theoretical K α x-ray emission linewidths of U, Np, and Pu
We present measurements of the Kα_{1} and Kα_{2} natural x-ray linewidths of uranium, neptunium, and plutonium (Z=92, 93, 94) obtained using a superconducting transition-edge sensor microcalorimeter array. The relative uncertainties range from 0.5% to 1.5%, improving upon previous values by factors ranging from 3 to 8. These refined linewidths reduce systematic errors in gamma-ray spectroscopy assays of Pu-bearing materials, where Kα x-rays overlap with diagnostic gamma lines. We also present multiconfiguration Dirac-Fock calculations of the Kα linewidths for U, Np, and Pu, providing a benchmark for theory and experiment. These calculations reveal a discrepancy between ab initio theory and experiment possible to observe only with the improved experimental accuracy achieved in this work.
- Open Access
- 17 April 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (16) , eaed3321
Direct observation of muonic molecules in resonance states critical to muon catalyzed fusion
Muon catalyzed fusion (μCF) is a plasma-free process in which the formation of muonic hydrogen molecules precedes and enables fusion between their constituent nuclei. Despite decades of study, the reaction dynamics of μCF remain elusive. Recent theories predict that resonance states of the muonic molecules play a key role and that these states can be probed using x-ray techniques. Using an array of transition-edge sensor microcalorimeters with 10-fold improved energy resolution compared to conventional silicon detectors, we observed x-rays from resonance states of muonic deuterium molecules despite an intense background. The spectrum is well explained by high-precision calculations incorporating the vibrational states. This work identifies the long-overlooked resonance state pathway as crucial in μCF and provides the direct evidence of the efficient muonic molecular formation.
- 17 April 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (16) , eaed3321
Open AccessDirect observation of muonic molecules in resonance states critical to muon catalyzed fusion
Muon catalyzed fusion (μCF) is a plasma-free process in which the formation of muonic hydrogen molecules precedes and enables fusion between their constituent nuclei. Despite decades of study, the reaction dynamics of μCF remain elusive. Recent theories predict that resonance states of the muonic molecules play a key role and that these states can be probed using x-ray techniques. Using an array of transition-edge sensor microcalorimeters with 10-fold improved energy resolution compared to conventional silicon detectors, we observed x-rays from resonance states of muonic deuterium molecules despite an intense background. The spectrum is well explained by high-precision calculations incorporating the vibrational states. This work identifies the long-overlooked resonance state pathway as crucial in μCF and provides the direct evidence of the efficient muonic molecular formation.
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-5
Time-Division SQUID Multiplexing With Nanohenry Scale Input Mutual Inductance Using Transformers With Intracoil Damping
Time division multiplexing (TDM) developed for the Athena X-ray integral field unit (X-IFU) has achieved readout performance that can be scaled to multiplexing factors of several hundred for TES bolometer missions. The lower slew rate requirements of bolometer and soft X-ray missions favor greater first stage SQUID amplifier input mutual inductance (Min) to reduce readout noise and compensate for aliasing as multiplexing factor is increased. We find that, as Min increases, TDM performance becomes sensitive to the design of the TES bias circuit, with degraded noise performance and the emergence of resonant features. In TDM chips with nanohenry scale Min, we demonstrate that this sensitivity can be eliminated by adding intra-coil damping resistors to the superconducting transformers, enabling the robust use of these higher Min multiplexers.
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-5
Time-Division SQUID Multiplexing With Nanohenry Scale Input Mutual Inductance Using Transformers With Intracoil Damping
Time division multiplexing (TDM) developed for the Athena X-ray integral field unit (X-IFU) has achieved readout performance that can be scaled to multiplexing factors of several hundred for TES bolometer missions. The lower slew rate requirements of bolometer and soft X-ray missions favor greater first stage SQUID amplifier input mutual inductance (Min) to reduce readout noise and compensate for aliasing as multiplexing factor is increased. We find that, as Min increases, TDM performance becomes sensitive to the design of the TES bias circuit, with degraded noise performance and the emergence of resonant features. In TDM chips with nanohenry scale Min, we demonstrate that this sensitivity can be eliminated by adding intra-coil damping resistors to the superconducting transformers, enabling the robust use of these higher Min multiplexers.
- 1 April 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 12 (02) , 1-11
Design of a mission to measure the shape and substructure of the 511 keV γ-ray line from the center of the Milky Way
The 511 keV electron-positron annihilation feature near the galactic center has been detected for more than half a century, yet its origin remains a mystery. We describe a concept for a balloon-borne 511 keV γ-ray mission called the 511-Spectrometer Mission. The mission will use transition-edge sensor (TES) arrays with thick metal absorbers that are thermally coupled to the TES. The strength of the approach is a projected energy resolution of 200-eV full-width half maximum (FWHM) at 511 keV, enabling detailed studies of the shape and substructure of the 511 keV emission from the galactic center region. A first mission equipped with 8192 γ-ray detectors and a fully active shield and collimator could detect the galactic center with 35 σ statistical significance. We present the mission concept as well as the first results obtained with a prototype detector equipped with 1.35×1.35×2 mm3 Bi absorbers. The detector has a quantum efficiency of 15% for 511 keV photons in photoelectric effect interactions. In tests with a Cs137 source, these prototype detectors show an energy resolution of 525 eV FWHM at 662 keV. We end with a discussion of follow-up missions that use coded mask imaging or use concentrating or focusing optics to scrutinize the sources of 511 keV γ-rays on smaller angular scales.
- 1 April 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 12 (02) , 1-11
Design of a mission to measure the shape and substructure of the 511 keV γ-ray line from the center of the Milky Way
The 511 keV electron-positron annihilation feature near the galactic center has been detected for more than half a century, yet its origin remains a mystery. We describe a concept for a balloon-borne 511 keV γ-ray mission called the 511-Spectrometer Mission. The mission will use transition-edge sensor (TES) arrays with thick metal absorbers that are thermally coupled to the TES. The strength of the approach is a projected energy resolution of 200-eV full-width half maximum (FWHM) at 511 keV, enabling detailed studies of the shape and substructure of the 511 keV emission from the galactic center region. A first mission equipped with 8192 γ-ray detectors and a fully active shield and collimator could detect the galactic center with 35 σ statistical significance. We present the mission concept as well as the first results obtained with a prototype detector equipped with 1.35×1.35×2 mm3 Bi absorbers. The detector has a quantum efficiency of 15% for 511 keV photons in photoelectric effect interactions. In tests with a Cs137 source, these prototype detectors show an energy resolution of 525 eV FWHM at 662 keV. We end with a discussion of follow-up missions that use coded mask imaging or use concentrating or focusing optics to scrutinize the sources of 511 keV γ-rays on smaller angular scales.
- Open Access
- 23 March 2026
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2026 (3)
Phenomenological modeling of the 163Ho calorimetric electron capture spectrum from the HOLMES experiment
A bstract: We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of 163 Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing 163 Ho, supporting both data analysis and experimental design.
- 23 March 2026
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2026 (3)
Open AccessPhenomenological modeling of the 163Ho calorimetric electron capture spectrum from the HOLMES experiment
A bstract: We present a comprehensive phenomenological analysis of the calorimetric electron capture (EC) decay spectrum of 163 Ho as measured by the HOLMES experiment. Using high-statistics data, we unfold the instrumental energy resolution from the measured spectrum and model it as a sum of Breit-Wigner resonances and shake-off continua, providing a complete set of parameters for each component. Our approach enables the identification and tentative interpretation of all observed spectral features, including weak and overlapping structures, in terms of atomic de-excitation processes. We compare our phenomenological model with recent ab initio theoretical calculations, finding good agreement for both the main peaks and the spectral tails, despite the limitations of current theoretical and experimental precision. The model delivers an accurate description of the endpoint region, which is crucial for neutrino mass determination, and allows for a realistic treatment of backgrounds such as pile-up and tails of low-energy components. Furthermore, our decomposition facilitates the generation of Monte Carlo toy spectra for sensitivity studies and provides a framework for investigating systematic uncertainties related to solid-state and detector effects. This work establishes a robust foundation for future calorimetric neutrino mass experiments employing 163 Ho, supporting both data analysis and experimental design.
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
Design, Fabrication, and Performance of Robust Gamma-Ray TES Detectors For Next-Generation Spectrometers
We discuss the development of molybdenum-gold bilayer transition edge sensors on solid silicon substrate microcalorimeter designs suitable for real-time measurement of gamma-ray sources in the keV to MeV range. These novel detector designs incorporate tunable thermal conductance over a range from 1x10-9 W/K to 4x10-7 W/K and are mechanically robust. We describe the micro-fabrication process and the gamma-ray absorber attachment in detail. Initial prototypes obtain detector response times twice as fast as our previous design while maintaining an energy resolution of less than 100 eV full-width-half-maximum at 100 keV.
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
Design, Fabrication, and Performance of Robust Gamma-Ray TES Detectors For Next-Generation Spectrometers
We discuss the development of molybdenum-gold bilayer transition edge sensors on solid silicon substrate microcalorimeter designs suitable for real-time measurement of gamma-ray sources in the keV to MeV range. These novel detector designs incorporate tunable thermal conductance over a range from 1x10-9 W/K to 4x10-7 W/K and are mechanically robust. We describe the micro-fabrication process and the gamma-ray absorber attachment in detail. Initial prototypes obtain detector response times twice as fast as our previous design while maintaining an energy resolution of less than 100 eV full-width-half-maximum at 100 keV.
- Open Access
- 29 September 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (14) , 141801
Most Stringent Bound on Electron Neutrino Mass Obtained with a Scalable Low-Temperature Microcalorimeter Array
The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the standard model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. Here we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of Ho 163 . The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of 7 × 10 7 decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of m β < 27 eV / c 2 at 90% credibility. These results validate the feasibility of Ho 163 calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.
- 29 September 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (14) , 141801
Open AccessMost Stringent Bound on Electron Neutrino Mass Obtained with a Scalable Low-Temperature Microcalorimeter Array
The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the standard model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. Here we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of Ho 163 . The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of 7 × 10 7 decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of m β < 27 eV / c 2 at 90% credibility. These results validate the feasibility of Ho 163 calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.
- 16 June 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (24) , 243001
Few-Electron Highly Charged Muonic Ar Atoms Verified by Electronic X RaysA highly charged muonic ion is a unique few-body atomic system where a negatively charged muon and a few electrons are simultaneously bound to a single nucleus. We report the first state-selective observation of highly charged muonic Ar (μAr) by electronic K x-ray spectroscopy using an array of transition-edge sensor microcalorimeters. The high-precision K x-ray spectra provide a clear signature of the presence of muonic atoms with one, two, and three electrons, i.e., H-like, He-like, and Li-like μAr. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflect deexcitation dynamics of highly charged μAr.
- 16 June 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (24) , 243001
Few-Electron Highly Charged Muonic Ar Atoms Verified by Electronic X RaysA highly charged muonic ion is a unique few-body atomic system where a negatively charged muon and a few electrons are simultaneously bound to a single nucleus. We report the first state-selective observation of highly charged muonic Ar (μAr) by electronic K x-ray spectroscopy using an array of transition-edge sensor microcalorimeters. The high-precision K x-ray spectra provide a clear signature of the presence of muonic atoms with one, two, and three electrons, i.e., H-like, He-like, and Li-like μAr. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflect deexcitation dynamics of highly charged μAr.