Allister F. McGuire
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Allister F. McGuire has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Bianxiao Cui
Stanford University
4 shared publications April D. Jewell
Department of Chemistry, Tufts University, Medford, Massachusetts 02155, USA
3 shared publications- Colin J. Murphy
Department of Chemistry, Tufts University, Medford, Massachusetts 02155, United States
3 shared publications Bianxiao Cui
Department of Chemistry, Stanford University Stanford, California 94305, USA
2 shared publicationsE. Charles H. Sykes
Department of Chemistry, Tufts University, 62 Talbot Avenue, Medford, Massachusetts 02155, United States
2 shared publicationsEmily A. Lewis
Department of Chemistry, Tufts University, Medford, Massachusetts 02155, USA
2 shared publications
Latest Publications
- Open Access
- 26 April 2022
- Published by Springer Nature in Nature Communications
- Vol. 13  (1) , 1-14
Nanocrown electrodes for parallel and robust intracellular recording of cardiomyocytes
Drug-induced cardiotoxicity arises primarily when a compound alters the electrophysiological properties of cardiomyocytes. Features of intracellular action potentials (iAPs) are powerful biomarkers that predict proarrhythmic risks. In the last decade, a number of vertical nanoelectrodes have been demonstrated to achieve parallel and minimally-invasive iAP recordings. However, the large variability in success rate and signal strength have hindered nanoelectrodes from being broadly adopted for proarrhythmia drug assessment. In this work, we develop vertically-aligned nanocrown electrodes that are mechanically robust and achieve > 99% success rates in obtaining intracellular access through electroporation. We validate the accuracy of nanocrown electrode recordings by simultaneous patch clamp recording from the same cell. Finally, we demonstrate that nanocrown electrodes enable prolonged iAP recording for continual monitoring of the same cells upon the sequential addition of four incremental drug doses. Our technology development provides an advancement towards establishing an iAP screening assay for preclinical evaluation of drug-induced arrhythmogenicity.
- 26 April 2022
- Published by Springer Nature in Nature Communications
- Vol. 13  (1) , 1-14
Open AccessNanocrown electrodes for parallel and robust intracellular recording of cardiomyocytes
Drug-induced cardiotoxicity arises primarily when a compound alters the electrophysiological properties of cardiomyocytes. Features of intracellular action potentials (iAPs) are powerful biomarkers that predict proarrhythmic risks. In the last decade, a number of vertical nanoelectrodes have been demonstrated to achieve parallel and minimally-invasive iAP recordings. However, the large variability in success rate and signal strength have hindered nanoelectrodes from being broadly adopted for proarrhythmia drug assessment. In this work, we develop vertically-aligned nanocrown electrodes that are mechanically robust and achieve > 99% success rates in obtaining intracellular access through electroporation. We validate the accuracy of nanocrown electrode recordings by simultaneous patch clamp recording from the same cell. Finally, we demonstrate that nanocrown electrodes enable prolonged iAP recording for continual monitoring of the same cells upon the sequential addition of four incremental drug doses. Our technology development provides an advancement towards establishing an iAP screening assay for preclinical evaluation of drug-induced arrhythmogenicity.
- 17 May 2019
- Published by Springer Nature in Nature Protocols
- Vol. 14  (6) , 1772-1802
A nanostructure platform for live-cell manipulation of membrane curvature
Membrane curvatures are involved in essential cellular processes, such as endocytosis and exocytosis, in which they are believed to act as microdomains for protein interactions and intracellular signaling. These membrane curvatures appear and disappear dynamically, and their locations are difficult or impossible to predict. In addition, the size of these curvatures is usually below the diffraction limit of visible light, making it impossible to resolve their values using live-cell imaging. Therefore, precise manipulation of membrane curvature is important to understanding how membrane curvature is involved in intracellular processes. Recent studies show that membrane curvatures can be induced by surface topography when cells are in direct contact with engineered substrates. Here, we present detailed procedures for using nanoscale structures to manipulate membrane curvatures and probe curvature-induced phenomena in live cells. We first describe detailed procedures for the design of nanoscale structures and their fabrication using electron-beam (E-beam) lithography. The fabrication process takes 2 d, but the resultant chips can be cleaned and reused repeatedly over the course of 2 years. Then we describe how to use these nanostructures to manipulate local membrane curvatures and probe intracellular protein responses, discussing surface coating, cell plating, and fluorescence imaging in detail. Finally, we describe a procedure to characterize the nanostructure–cell membrane interface using focused ion beam and scanning electron microscopy (FIB–SEM). Nanotopography-based methods can induce stable membrane curvatures with well-defined curvature values and locations in live cells, which enables the generation of a library of curvatures for probing curvature-related intracellular processes.
- 17 May 2019
- Published by Springer Nature in Nature Protocols
- Vol. 14  (6) , 1772-1802
A nanostructure platform for live-cell manipulation of membrane curvature
Membrane curvatures are involved in essential cellular processes, such as endocytosis and exocytosis, in which they are believed to act as microdomains for protein interactions and intracellular signaling. These membrane curvatures appear and disappear dynamically, and their locations are difficult or impossible to predict. In addition, the size of these curvatures is usually below the diffraction limit of visible light, making it impossible to resolve their values using live-cell imaging. Therefore, precise manipulation of membrane curvature is important to understanding how membrane curvature is involved in intracellular processes. Recent studies show that membrane curvatures can be induced by surface topography when cells are in direct contact with engineered substrates. Here, we present detailed procedures for using nanoscale structures to manipulate membrane curvatures and probe curvature-induced phenomena in live cells. We first describe detailed procedures for the design of nanoscale structures and their fabrication using electron-beam (E-beam) lithography. The fabrication process takes 2 d, but the resultant chips can be cleaned and reused repeatedly over the course of 2 years. Then we describe how to use these nanostructures to manipulate local membrane curvatures and probe intracellular protein responses, discussing surface coating, cell plating, and fluorescence imaging in detail. Finally, we describe a procedure to characterize the nanostructure–cell membrane interface using focused ion beam and scanning electron microscopy (FIB–SEM). Nanotopography-based methods can induce stable membrane curvatures with well-defined curvature values and locations in live cells, which enables the generation of a library of curvatures for probing curvature-related intracellular processes.
- 12 June 2018
- Published by Annual Reviews in Annual Review of Analytical Chemistry
- Vol. 11  (1) , 101-126
Interfacing Cells with Vertical Nanoscale Devices: Applications and Characterization
Measurements of the intracellular state of mammalian cells often require probes or molecules to breach the tightly regulated cell membrane. Mammalian cells have been shown to grow well on vertical nanoscale structures in vitro, going out of their way to reach and tightly wrap the structures. A great deal of research has taken advantage of this interaction to bring probes close to the interface or deliver molecules with increased efficiency or ease. In turn, techniques have been developed to characterize this interface. Here, we endeavor to survey this research with an emphasis on the interface as driven by cellular mechanisms.
- 12 June 2018
- Published by Annual Reviews in Annual Review of Analytical Chemistry
- Vol. 11  (1) , 101-126
Interfacing Cells with Vertical Nanoscale Devices: Applications and Characterization
Measurements of the intracellular state of mammalian cells often require probes or molecules to breach the tightly regulated cell membrane. Mammalian cells have been shown to grow well on vertical nanoscale structures in vitro, going out of their way to reach and tightly wrap the structures. A great deal of research has taken advantage of this interaction to bring probes close to the interface or deliver molecules with increased efficiency or ease. In turn, techniques have been developed to characterize this interface. Here, we endeavor to survey this research with an emphasis on the interface as driven by cellular mechanisms.
- Top Cited Papers
- 16 May 2017
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 114  (20) , 5107-5112
Biocompatible and totally disintegrable semiconducting polymer for ultrathin and ultralightweight transient electronics
Increasing performance demands and shorter use lifetimes of consumer electronics have resulted in the rapid growth of electronic waste. Currently, consumer electronics are typically made with nondecomposable, nonbiocompatible, and sometimes even toxic materials, leading to serious ecological challenges worldwide. Here, we report an example of totally disintegrable and biocompatible semiconducting polymers for thin-film transistors. The polymer consists of reversible imine bonds and building blocks that can be easily decomposed under mild acidic conditions. In addition, an ultrathin (800-nm) biodegradable cellulose substrate with high chemical and thermal stability is developed. Coupled with iron electrodes, we have successfully fabricated fully disintegrable and biocompatible polymer transistors. Furthermore, disintegrable and biocompatible pseudo-complementary metal–oxide–semiconductor (CMOS) flexible circuits are demonstrated. These flexible circuits are ultrathin (2) with low operating voltage (4 V), yielding potential applications of these disintegrable semiconducting polymers in low-cost, biocompatible, and ultralightweight transient electronics.
- 16 May 2017
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 114  (20) , 5107-5112
Top Cited PapersBiocompatible and totally disintegrable semiconducting polymer for ultrathin and ultralightweight transient electronics
Increasing performance demands and shorter use lifetimes of consumer electronics have resulted in the rapid growth of electronic waste. Currently, consumer electronics are typically made with nondecomposable, nonbiocompatible, and sometimes even toxic materials, leading to serious ecological challenges worldwide. Here, we report an example of totally disintegrable and biocompatible semiconducting polymers for thin-film transistors. The polymer consists of reversible imine bonds and building blocks that can be easily decomposed under mild acidic conditions. In addition, an ultrathin (800-nm) biodegradable cellulose substrate with high chemical and thermal stability is developed. Coupled with iron electrodes, we have successfully fabricated fully disintegrable and biocompatible polymer transistors. Furthermore, disintegrable and biocompatible pseudo-complementary metal–oxide–semiconductor (CMOS) flexible circuits are demonstrated. These flexible circuits are ultrathin (2) with low operating voltage (4 V), yielding potential applications of these disintegrable semiconducting polymers in low-cost, biocompatible, and ultralightweight transient electronics.
- Open Access
- 13 March 2017
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 3  (1) , 16080
Accurate nanoelectrode recording of human pluripotent stem cell-derived cardiomyocytes for assaying drugs and modeling disease
The measurement of the electrophysiology of human pluripotent stem cell-derived cardiomyocytes is critical for their biomedical applications, from disease modeling to drug screening. Yet, a method that enables the high-throughput intracellular electrophysiology measurement of single cardiomyocytes in adherent culture is not available. To address this area, we have fabricated vertical nanopillar electrodes that can record intracellular action potentials from up to 60 single beating cardiomyocytes. Intracellular access is achieved by highly localized electroporation, which allows for low impedance electrical access to the intracellular voltage. Herein, we demonstrate that this method provides the accurate measurement of the shape and duration of intracellular action potentials, validated by patch clamp, and can facilitate cellular drug screening and disease modeling using human pluripotent stem cells. This study validates the use of nanopillar electrodes for myriad further applications of human pluripotent stem cell-derived cardiomyocytes such as cardiomyocyte maturation monitoring and electrophysiology-contractile force correlation.
- 13 March 2017
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 3  (1) , 16080
Open AccessAccurate nanoelectrode recording of human pluripotent stem cell-derived cardiomyocytes for assaying drugs and modeling disease
The measurement of the electrophysiology of human pluripotent stem cell-derived cardiomyocytes is critical for their biomedical applications, from disease modeling to drug screening. Yet, a method that enables the high-throughput intracellular electrophysiology measurement of single cardiomyocytes in adherent culture is not available. To address this area, we have fabricated vertical nanopillar electrodes that can record intracellular action potentials from up to 60 single beating cardiomyocytes. Intracellular access is achieved by highly localized electroporation, which allows for low impedance electrical access to the intracellular voltage. Herein, we demonstrate that this method provides the accurate measurement of the shape and duration of intracellular action potentials, validated by patch clamp, and can facilitate cellular drug screening and disease modeling using human pluripotent stem cells. This study validates the use of nanopillar electrodes for myriad further applications of human pluripotent stem cell-derived cardiomyocytes such as cardiomyocyte maturation monitoring and electrophysiology-contractile force correlation.
- Open Access
- 16 December 2016
- Published by Springer Nature in Nature Communications
- Vol. 7  (1) , 13704
Imaging electric field dynamics with graphene optoelectronics
The use of electric fields for signalling and control in liquids is widespread, spanning bioelectric activity in cells to electrical manipulation of microstructures in lab-on-a-chip devices. However, an appropriate tool to resolve the spatio-temporal distribution of electric fields over a large dynamic range has yet to be developed. Here we present a label-free method to image local electric fields in real time and under ambient conditions. Our technique combines the unique gate-variable optical transitions of graphene with a critically coupled planar waveguide platform that enables highly sensitive detection of local electric fields with a voltage sensitivity of a few microvolts, a spatial resolution of tens of micrometres and a frequency response over tens of kilohertz. Our imaging platform enables parallel detection of electric fields over a large field of view and can be tailored to broad applications spanning lab-on-a-chip device engineering to analysis of bioelectric phenomena.
- 16 December 2016
- Published by Springer Nature in Nature Communications
- Vol. 7  (1) , 13704
Open AccessImaging electric field dynamics with graphene optoelectronics
The use of electric fields for signalling and control in liquids is widespread, spanning bioelectric activity in cells to electrical manipulation of microstructures in lab-on-a-chip devices. However, an appropriate tool to resolve the spatio-temporal distribution of electric fields over a large dynamic range has yet to be developed. Here we present a label-free method to image local electric fields in real time and under ambient conditions. Our technique combines the unique gate-variable optical transitions of graphene with a critically coupled planar waveguide platform that enables highly sensitive detection of local electric fields with a voltage sensitivity of a few microvolts, a spatial resolution of tens of micrometres and a frequency response over tens of kilohertz. Our imaging platform enables parallel detection of electric fields over a large field of view and can be tailored to broad applications spanning lab-on-a-chip device engineering to analysis of bioelectric phenomena.
- Top Cited Papers
- 16 October 2015
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 350  (6258) , 313-316
A skin-inspired organic digital mechanoreceptor
Sensing the force digitally: Our skin provides us with a flexible waterproof barrier, but it also contains a sensor array that feels the world around us. This array provides feedback and helps us to avoid a hot object or increase the strength of our grip on an object that may be slipping away. Tee et al. describe an approach to simulate the mechanoreceptors of human skin, using pressure-sensitive foils and printed ring oscillators (see the Perspective by Anikeeva and Koppes). The sensor successfully converted pressure into a digital response in a pressure range comparable to that found in a human grip. Science , this issue p. 313 ; see also p. 274
- 16 October 2015
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 350  (6258) , 313-316
Top Cited PapersA skin-inspired organic digital mechanoreceptor
Sensing the force digitally: Our skin provides us with a flexible waterproof barrier, but it also contains a sensor array that feels the world around us. This array provides feedback and helps us to avoid a hot object or increase the strength of our grip on an object that may be slipping away. Tee et al. describe an approach to simulate the mechanoreceptors of human skin, using pressure-sensitive foils and printed ring oscillators (see the Perspective by Anikeeva and Koppes). The sensor successfully converted pressure into a digital response in a pressure range comparable to that found in a human grip. Science , this issue p. 313 ; see also p. 274
- 11 February 2015
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 142  (10) , 101915
Impact of branching on the supramolecular assembly of thioethers on Au(111)
Alkanethiolate monolayers are one of the most comprehensively studied self-assembled systems due to their ease of preparation, their ability to be functionalized, and the opportunity to control their thickness perpendicular to the surface. However, these systems suffer from degradation due to oxidation and defects caused by surface etching and adsorbate rotational boundaries. Thioethers offer a potential alternative to thiols that overcome some of these issues and allow dimensional control of self-assembly parallel to the surface. Thioethers have found uses in surface modification of nanoparticles, and chiral thioethers tethered to catalytically active surfaces have been shown to enable enantioselective hydrogenation. However, the effect of structural, chemical, and chiral modifications of the alkyl chains of thioethers on their self-assembly has remained largely unstudied. To elucidate how molecular structure, particularly alkyl branching and chirality, affects molecular self-assembly, we compare four related thioethers, including two pairs of structural isomers. The self-assembly of structural isomers N-butyl methyl sulfide and tert-butyl methyl sulfide was studied with high resolution scanning tunneling microscopy (STM); our results indicate that both molecules form highly ordered arrays despite the bulky tert-butyl group. We also investigated the effect of intrinsic chirality in the alkyl tails on the adsorption and self-assembly of butyl sec-butyl sulfide (BSBS) with STM and density functional theory and contrast our results to its structural isomer, dibutyl sulfide. Calculations provide the relative stability of the four stereoisomers of BSBS and STM imaging reveals two prominent monomer forms. Interestingly, the racemic mixture of BSBS is the only thioether we have examined to date that does not form highly ordered arrays; we postulate that this is due to weak enantiospecific intermolecular interactions that lead to the formation of energetically similar but structurally different assemblies. Furthermore, we studied all of the molecules in their monomeric molecular rotor form, and the surface-adsorbed chirality of the three asymmetric thioethers is distinguishable in STM images.
- 11 February 2015
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 142  (10) , 101915
Impact of branching on the supramolecular assembly of thioethers on Au(111)
Alkanethiolate monolayers are one of the most comprehensively studied self-assembled systems due to their ease of preparation, their ability to be functionalized, and the opportunity to control their thickness perpendicular to the surface. However, these systems suffer from degradation due to oxidation and defects caused by surface etching and adsorbate rotational boundaries. Thioethers offer a potential alternative to thiols that overcome some of these issues and allow dimensional control of self-assembly parallel to the surface. Thioethers have found uses in surface modification of nanoparticles, and chiral thioethers tethered to catalytically active surfaces have been shown to enable enantioselective hydrogenation. However, the effect of structural, chemical, and chiral modifications of the alkyl chains of thioethers on their self-assembly has remained largely unstudied. To elucidate how molecular structure, particularly alkyl branching and chirality, affects molecular self-assembly, we compare four related thioethers, including two pairs of structural isomers. The self-assembly of structural isomers N-butyl methyl sulfide and tert-butyl methyl sulfide was studied with high resolution scanning tunneling microscopy (STM); our results indicate that both molecules form highly ordered arrays despite the bulky tert-butyl group. We also investigated the effect of intrinsic chirality in the alkyl tails on the adsorption and self-assembly of butyl sec-butyl sulfide (BSBS) with STM and density functional theory and contrast our results to its structural isomer, dibutyl sulfide. Calculations provide the relative stability of the four stereoisomers of BSBS and STM imaging reveals two prominent monomer forms. Interestingly, the racemic mixture of BSBS is the only thioether we have examined to date that does not form highly ordered arrays; we postulate that this is due to weak enantiospecific intermolecular interactions that lead to the formation of energetically similar but structurally different assemblies. Furthermore, we studied all of the molecules in their monomeric molecular rotor form, and the surface-adsorbed chirality of the three asymmetric thioethers is distinguishable in STM images.
- 18 June 2012
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 116  (28) , 14992-14997
Hydrogen Bonding and Chirality in Functionalized Thioether Self-Assembly
- 18 June 2012
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 116  (28) , 14992-14997
Hydrogen Bonding and Chirality in Functionalized Thioether Self-Assembly
- Top Cited Papers
- 4 September 2011
- Published by Springer Nature in Nature Nanotechnology
- Vol. 6  (10) , 625-629
Experimental demonstration of a single-molecule electric motor
For molecules to be used as components in molecular machines, methods that couple individual molecules to external energy sources and that selectively excite motion in a given direction are required. Significant progress has been made in the construction of molecular motors powered by light and by chemical reactions, but electrically driven motors have not yet been built, despite several theoretical proposals for such motors. Here we report that a butyl methyl sulphide molecule adsorbed on a copper surface can be operated as a single-molecule electric motor. Electrons from a scanning tunnelling microscope are used to drive the directional motion of the molecule in a two-terminal setup. Moreover, the temperature and electron flux can be adjusted to allow each rotational event to be monitored at the molecular scale in real time. The direction and rate of the rotation are related to the chiralities of both the molecule and the tip of the microscope (which serves as the electrode), illustrating the importance of the symmetry of the metal contacts in atomic-scale electrical devices.
- 4 September 2011
- Published by Springer Nature in Nature Nanotechnology
- Vol. 6  (10) , 625-629
Top Cited PapersExperimental demonstration of a single-molecule electric motor
For molecules to be used as components in molecular machines, methods that couple individual molecules to external energy sources and that selectively excite motion in a given direction are required. Significant progress has been made in the construction of molecular motors powered by light and by chemical reactions, but electrically driven motors have not yet been built, despite several theoretical proposals for such motors. Here we report that a butyl methyl sulphide molecule adsorbed on a copper surface can be operated as a single-molecule electric motor. Electrons from a scanning tunnelling microscope are used to drive the directional motion of the molecule in a two-terminal setup. Moreover, the temperature and electron flux can be adjusted to allow each rotational event to be monitored at the molecular scale in real time. The direction and rate of the rotation are related to the chiralities of both the molecule and the tip of the microscope (which serves as the electrode), illustrating the importance of the symmetry of the metal contacts in atomic-scale electrical devices.