Aboutaleb Kermani
Aboutaleb Kermani has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Kaveh Edalati
WPI, International Institute for Carbon-Neutral Energy Research (WPI-I2CNER), Kyushu University, Fukuoka, Japan
8 shared publications A. Movafeghi
6 shared publicationsM. Seiedi
6 shared publications- Behrouz Rokrok
Nuclear Science and Technology Research Institute, Tehran, Iran
4 shared publications N. Rastkhah
Radiation Protection Technological Center of Iran 1 Department of NDT and Inspection Tehran, Iran
4 shared publicationsA Movafeghi
PhD Candidate, School of Mechanical Engineering, Sharif University of Technology, Tehran, NDT level-3 Certificate Holder
1 shared publication
Latest Publications
- 1 May 2008
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 36 (3) , 264-272
Thickness Gaging of Thin Plates by Multi-Peak Frequency Decomposition of Lamb Wave Signals
In the present work ultrasonic Lamb wave testing has been applied for thickness gaging of thin aluminum plates with 2, 3, and 4-mm thickness. Angle probes operated in pulse-echo arrangement with 0.98 MHz central frequency and 7°, 12°, and 20° incident angles were utilized for investigations. High order modes (A1, S1, A2, and S2) were selected and evaluated for measurements and a fast Fourier transform was utilized for frequency decomposition. The variation with thickness and frequency of the phase velocity was the basis of measurement. Two methods were proposed for thickness gaging: (1) a probe with 6000–8000 m/s phase velocity and one or two other probes with higher than 10 000 m/s phase velocity were utilized simultaneously to inspect each test area and the peak frequency with the highest amplitude excited by each probe was evaluated, and (2) a single probe was utilized and all visible peak frequencies were evaluated. These methods overcome the limitations of the previous research, which applied a peak frequency shift method for corrosion monitoring of plates only for a known mode and known initial thickness and low thickness reductions. The second method is more practical and accurate and has potential for on-line automatic thickness gaging of rolled plates.
- 1 May 2008
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 36 (3) , 264-272
Thickness Gaging of Thin Plates by Multi-Peak Frequency Decomposition of Lamb Wave Signals
In the present work ultrasonic Lamb wave testing has been applied for thickness gaging of thin aluminum plates with 2, 3, and 4-mm thickness. Angle probes operated in pulse-echo arrangement with 0.98 MHz central frequency and 7°, 12°, and 20° incident angles were utilized for investigations. High order modes (A1, S1, A2, and S2) were selected and evaluated for measurements and a fast Fourier transform was utilized for frequency decomposition. The variation with thickness and frequency of the phase velocity was the basis of measurement. Two methods were proposed for thickness gaging: (1) a probe with 6000–8000 m/s phase velocity and one or two other probes with higher than 10 000 m/s phase velocity were utilized simultaneously to inspect each test area and the peak frequency with the highest amplitude excited by each probe was evaluated, and (2) a single probe was utilized and all visible peak frequencies were evaluated. These methods overcome the limitations of the previous research, which applied a peak frequency shift method for corrosion monitoring of plates only for a known mode and known initial thickness and low thickness reductions. The second method is more practical and accurate and has potential for on-line automatic thickness gaging of rolled plates.
- 1 July 2007
- Published by Elsevier in International Journal of Pressure Vessels and Piping
- Vol. 84 (7) , 441-450
Scattering and image contrast simulation for double wall radiography of pipes
- 1 July 2007
- Published by Elsevier in International Journal of Pressure Vessels and Piping
- Vol. 84 (7) , 441-450
Scattering and image contrast simulation for double wall radiography of pipes
- 1 November 2006
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 34 (6) , 562-569
Sensitivity Evaluation in Double Wall Radiography of Pipes and Multilayer Plates by Assessment the Monte Carlo Simulation
Image quality indicator (IQI) is selected based on the single and/or double wall thickness of pipe with or without considering the radiographic techniques or applied radiation source (x ray or gamma ray), in accordance with the sensitivity requirements of reference codes. Discrepancies in the codes and standards for sensitivity evaluation and IQI selection have been investigated in the present work and some experiments have been performed to measure the gamma ray or x-ray radiographic sensitivity for pipes and plates to compare the results with sensitivity requirements of the standards. Due to the considerable effect of scattering on the sensitivity, Monte Carlo method has also been used to simulate the scattering for gamma ray radiography of pipes and plates. Experiments revealed that 2% sensitivity based on the single wall thickness was attainable for double wall exposure and single wall viewing (DWSI) technique, but it could not be easily obtained for double wall exposure and double wall viewing (DWDI) gamma ray technique. Higher sensitivity was obtained for x-ray radiography and a considerable sensitivity reduction was found for in-service radiography of pipes. Achieved sensitivities were in good agreement with measured effective attenuation coefficients and simulation results which confirmed that scattering was, respectively, higher for DWDI radiography of pipe, radiography of single layer plate, and DWSI radiography of two layer plate with identical penetrated thickness. Therefore, IQI selection was proposed to be based on the single wall thickness of component except for DWDI Gamma ray radiography, which was proposed to be based on the double wall thickness.
- 1 November 2006
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 34 (6) , 562-569
Sensitivity Evaluation in Double Wall Radiography of Pipes and Multilayer Plates by Assessment the Monte Carlo Simulation
Image quality indicator (IQI) is selected based on the single and/or double wall thickness of pipe with or without considering the radiographic techniques or applied radiation source (x ray or gamma ray), in accordance with the sensitivity requirements of reference codes. Discrepancies in the codes and standards for sensitivity evaluation and IQI selection have been investigated in the present work and some experiments have been performed to measure the gamma ray or x-ray radiographic sensitivity for pipes and plates to compare the results with sensitivity requirements of the standards. Due to the considerable effect of scattering on the sensitivity, Monte Carlo method has also been used to simulate the scattering for gamma ray radiography of pipes and plates. Experiments revealed that 2% sensitivity based on the single wall thickness was attainable for double wall exposure and single wall viewing (DWSI) technique, but it could not be easily obtained for double wall exposure and double wall viewing (DWDI) gamma ray technique. Higher sensitivity was obtained for x-ray radiography and a considerable sensitivity reduction was found for in-service radiography of pipes. Achieved sensitivities were in good agreement with measured effective attenuation coefficients and simulation results which confirmed that scattering was, respectively, higher for DWDI radiography of pipe, radiography of single layer plate, and DWSI radiography of two layer plate with identical penetrated thickness. Therefore, IQI selection was proposed to be based on the single wall thickness of component except for DWDI Gamma ray radiography, which was proposed to be based on the double wall thickness.
- 1 October 2006
- Published by Elsevier in International Journal of Pressure Vessels and Piping
- Vol. 83 (10) , 736-741
The use of radiography for thickness measurement and corrosion monitoring in pipes
- 1 October 2006
- Published by Elsevier in International Journal of Pressure Vessels and Piping
- Vol. 83 (10) , 736-741
The use of radiography for thickness measurement and corrosion monitoring in pipes
- 1 January 2006
- Published by Inderscience Publishers in International Journal of Materials and Product Technology
- Vol. 27 (3/4) , 156
Defect detection in thin plates by ultrasonic lamb wave techniques
In the present study, the ability of ultrasonic lamb wave testing for defect detection and sizing in a thin aluminium plate (2mm in thickness) was investigated. The numerical methods were applied for drawing the dispersion and displacement curves of lamb waves in order to adopt mode selection. Two ultrasonic lamb wave techniques, pulse-echo (a
- 1 January 2006
- Published by Inderscience Publishers in International Journal of Materials and Product Technology
- Vol. 27 (3/4) , 156
Defect detection in thin plates by ultrasonic lamb wave techniques
In the present study, the ability of ultrasonic lamb wave testing for defect detection and sizing in a thin aluminium plate (2mm in thickness) was investigated. The numerical methods were applied for drawing the dispersion and displacement curves of lamb waves in order to adopt mode selection. Two ultrasonic lamb wave techniques, pulse-echo (a
- 10 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (10823654) , 1845-1849
Quality improvement of digitized radiographs by filtering technique development based on morphological transformations
Radiographic inspection is the most appreciated technique among the other non-destructive testing methods due to producing unique finger print record as the film. Converting of radiographs to a digital format and further digital image processing is the best method of enhancing the image quality and assisting the interpreter on his evaluation. In this research, different algorithms were used for image enhancement and radiograph interpretation in Matlab environment. A graphical user interface (GUI) was created for implementation of different algorithms. Both spatial and frequency (wavelet) domains techniques were used for image enhancement. Results showed that the defect recognition probability can be increased effectively in both domains. However it was included that better results can be achieved using a supervised spatial technique based on morphological transformation (top-hat and bottom-hat transforms).
- 10 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (10823654) , 1845-1849
Quality improvement of digitized radiographs by filtering technique development based on morphological transformations
Radiographic inspection is the most appreciated technique among the other non-destructive testing methods due to producing unique finger print record as the film. Converting of radiographs to a digital format and further digital image processing is the best method of enhancing the image quality and assisting the interpreter on his evaluation. In this research, different algorithms were used for image enhancement and radiograph interpretation in Matlab environment. A graphical user interface (GUI) was created for implementation of different algorithms. Both spatial and frequency (wavelet) domains techniques were used for image enhancement. Results showed that the defect recognition probability can be increased effectively in both domains. However it was included that better results can be achieved using a supervised spatial technique based on morphological transformation (top-hat and bottom-hat transforms).
- 1 October 2004
- Published by British Institute of Non-Destructive Testing (BINDT) in Insight - Non-Destructive Testing and Condition Monitoring
- Vol. 46 (10) , 594-597
A radiographic calibration method for eddy current testing of heat exchanger tubes
- 1 October 2004
- Published by British Institute of Non-Destructive Testing (BINDT) in Insight - Non-Destructive Testing and Condition Monitoring
- Vol. 46 (10) , 594-597
A radiographic calibration method for eddy current testing of heat exchanger tubes
- 1 July 2004
- Published by British Institute of Non-Destructive Testing (BINDT) in Insight - Non-Destructive Testing and Condition Monitoring
- Vol. 46 (7) , 396-398
In-service corrosion evaluation in pipelines using gamma radiography – a numerical approach
Wall thickness measurement and deterioration determination of 6 and 10 inch pipes due to corrosion/erosion/pitting was evaluated by using radiographic film density measurements. Special reference blocks were prepared with defined step wall reductions and artificial defects. Gamma radiography with a Ir-192 source was used. A double-wall technique with longitudinal film arrangement was used for this purpose. Formulae were developed from the experiments for numerical calculations. It was observed that this method can determine remaining wall thickness as well as pitting corrosion in insulated and non-insulated pipes with differential and absolute density measurements. The purpose of the work was the optimisation of techniques, quality control, evaluation of radiographs and parameters affecting the results. Furthermore, the studies included investigation on the limitations of each technique and stability of test conditions. Results show good precision – above 97% – between real and calculated values.
- 1 July 2004
- Published by British Institute of Non-Destructive Testing (BINDT) in Insight - Non-Destructive Testing and Condition Monitoring
- Vol. 46 (7) , 396-398
In-service corrosion evaluation in pipelines using gamma radiography – a numerical approach
Wall thickness measurement and deterioration determination of 6 and 10 inch pipes due to corrosion/erosion/pitting was evaluated by using radiographic film density measurements. Special reference blocks were prepared with defined step wall reductions and artificial defects. Gamma radiography with a Ir-192 source was used. A double-wall technique with longitudinal film arrangement was used for this purpose. Formulae were developed from the experiments for numerical calculations. It was observed that this method can determine remaining wall thickness as well as pitting corrosion in insulated and non-insulated pipes with differential and absolute density measurements. The purpose of the work was the optimisation of techniques, quality control, evaluation of radiographs and parameters affecting the results. Furthermore, the studies included investigation on the limitations of each technique and stability of test conditions. Results show good precision – above 97% – between real and calculated values.
- 1 January 2004
- Published by ASME International
- p. 915-919
Corrosion Detection in Pipelines by Radiograph Density Measurements
In this study the thickness profile of pipes; with 6 inch in diameter and thickness ranges from 4.2 to 15.0 mm; was determined by using radiograph density measurements. It was concluded that thickness loss of 10, 20 and 50 percent and corrosion surface could be determined by this method in pipes. Also some Formulas were drawn and suggested for this method.
- 1 January 2004
- Published by ASME International
- p. 915-919
Corrosion Detection in Pipelines by Radiograph Density Measurements
In this study the thickness profile of pipes; with 6 inch in diameter and thickness ranges from 4.2 to 15.0 mm; was determined by using radiograph density measurements. It was concluded that thickness loss of 10, 20 and 50 percent and corrosion surface could be determined by this method in pipes. Also some Formulas were drawn and suggested for this method.