Joaquim Madeira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joaquim Madeira has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Beatriz Sousa Santos
IEETA, DETI, LASI, University of Aveiro, Aveiro, Portugal
27 shared publications - Samuel Silva
IEETA, DETI, LASI, University of Aveiro, Aveiro, Portugal
23 shared publications - Carlos Ferreira
University of Aveiro
11 shared publications - Augusto Silva
University of Aveiro
7 shared publications - Paulo Dias
IEETA, DETI, LASI, University of Aveiro, Aveiro, Portugal
6 shared publications Angela Pimentel
Univ. de Aveiro
2 shared publications
Latest Publications
- Open Access
- 7 August 2021
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (1) , 65-73
A virtual reality simulator for training the surgical reduction of patient-specific supracondylar humerus fractures
Purpose: Virtual reality has been used as a training platform in medicine, allowing the repetition of a situation/scenario as many times as needed and making it patient-specific prior to an operation. Of special interest is the minimally invasive plate osteosynthesis (MIPO). It represents a novel technique for orthopedic trauma surgery, but requires intensive training to acquire the required skills. In this paper, we propose a virtual reality platform for training the surgical reduction of supracondylar fractures of the humerus using MIPO. The system presents a detailed surgical theater where the surgeon has to place the bone fragments properly. Methods: Seven experienced users were selected to perform a surgical reduction using our proposal. Two paired humeri were scanned from a dataset obtained from the Complejo Hospitalario de Jaén. A virtual fracture was performed in one side of the pair, using the other as contralateral part. Users have to simulate a reduction for each case and fill out a survey about usability, using a five-option Likert scale. Results: The subjects have obtained excellent scores in both simulations. The users have notably reduced the time employed in the second experiment, being 60% less in average. Subjects have valued the usability (5.0), the intuitiveness (4.6), comfort (4.5), and realism (4.9) in a 1–5 Likert scale. The mean score of the usability survey was 4.66. Conclusion: The system has shown a high learning rate, and it is expected that the trainees will reach an expert level after additional runs. By focusing on the movement of bone fragments, specialists acquire motor skills to avoid the malrotation of MIPO-treated fractures. A future study can fulfill the requirements needed to include this training system into the protocol of real surgeries. Therefore, we expect the system to increase the confidence of the trainees as well as to improve their decision making.
- 7 August 2021
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (1) , 65-73
Open AccessA virtual reality simulator for training the surgical reduction of patient-specific supracondylar humerus fractures
Purpose: Virtual reality has been used as a training platform in medicine, allowing the repetition of a situation/scenario as many times as needed and making it patient-specific prior to an operation. Of special interest is the minimally invasive plate osteosynthesis (MIPO). It represents a novel technique for orthopedic trauma surgery, but requires intensive training to acquire the required skills. In this paper, we propose a virtual reality platform for training the surgical reduction of supracondylar fractures of the humerus using MIPO. The system presents a detailed surgical theater where the surgeon has to place the bone fragments properly. Methods: Seven experienced users were selected to perform a surgical reduction using our proposal. Two paired humeri were scanned from a dataset obtained from the Complejo Hospitalario de Jaén. A virtual fracture was performed in one side of the pair, using the other as contralateral part. Users have to simulate a reduction for each case and fill out a survey about usability, using a five-option Likert scale. Results: The subjects have obtained excellent scores in both simulations. The users have notably reduced the time employed in the second experiment, being 60% less in average. Subjects have valued the usability (5.0), the intuitiveness (4.6), comfort (4.5), and realism (4.9) in a 1–5 Likert scale. The mean score of the usability survey was 4.66. Conclusion: The system has shown a high learning rate, and it is expected that the trainees will reach an expert level after additional runs. By focusing on the movement of bone fragments, specialists acquire motor skills to avoid the malrotation of MIPO-treated fractures. A future study can fulfill the requirements needed to include this training system into the protocol of real surgeries. Therefore, we expect the system to increase the confidence of the trainees as well as to improve their decision making.
- 1 October 2019
- Published by IGI Global Scientific Publishing in International Journal of Mobile and Blended Learning
- Vol. 11 (4) , 59-79
Evaluation of a Mobile Augmented Reality Game Application as an Outdoor Learning Tool
There is a discussion on the potential of augmented reality (AR), mobile technologies to enhance learning. This article presents: 1) the EduPARK project's first cycle of design-based research for the development of a mobile AR game-like app that aims to promote learning in an urban park, and 2) an experience of students using it in loco. The focus is the students' perceptions regarding the usability and functionality of the app. Data collection involved focus groups, questionnaires and app usage information. Data was submitted to content analysis and descriptive statistics. Results revealed an excellent usability of the EduPARK app, with an average system usability scale of 85.6. Overall, students reported that the app was enjoyable, easy to use and promoted learning; however, improvements and more evaluation experiences are needed to better understand mobile AR game-like learning in urban parks.
- 1 October 2019
- Published by IGI Global Scientific Publishing in International Journal of Mobile and Blended Learning
- Vol. 11 (4) , 59-79
Evaluation of a Mobile Augmented Reality Game Application as an Outdoor Learning Tool
There is a discussion on the potential of augmented reality (AR), mobile technologies to enhance learning. This article presents: 1) the EduPARK project's first cycle of design-based research for the development of a mobile AR game-like app that aims to promote learning in an urban park, and 2) an experience of students using it in loco. The focus is the students' perceptions regarding the usability and functionality of the app. Data collection involved focus groups, questionnaires and app usage information. Data was submitted to content analysis and descriptive statistics. Results revealed an excellent usability of the EduPARK app, with an average system usability scale of 85.6. Overall, students reported that the app was enjoyable, easy to use and promoted learning; however, improvements and more evaluation experiences are needed to better understand mobile AR game-like learning in urban parks.
- 19 June 2015
- Published by SPIE-Intl Soc Optical Eng
- p. 95350T-95350T-8
Feature enhancement from electrical resistivity data in an archaeological survey: the Sapelos hillfort experiment (Boticas, Portugal)
- 19 June 2015
- Published by SPIE-Intl Soc Optical Eng
- p. 95350T-95350T-8
Feature enhancement from electrical resistivity data in an archaeological survey: the Sapelos hillfort experiment (Boticas, Portugal)
- 1 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 336-341
Computer-Assisted Myocardial Perfusion Assessment
Left ventricle functional analysis can be performed using coronary CT angiography (CTA) images. In recent years it has been proposed that CTA imaging might also be used for myocardial perfusion assessment, by visually looking for hypoattenuated regions that may correspond to hypoperfusion. Assigning a detected lesion to a specific myocardial segment requires significant effort while the clinician matches the American Heart Association (AHA) standard myocardial segments to the anatomy of each patient. This article presents an interactive tool which, based on the existence of a previous left ventricle segmentation, automatically matches the lesions detected by the clinician to a myocardial segment and provides feedback over the image regarding the myocardial segments with detected lesions and their severity.
- 1 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 336-341
Computer-Assisted Myocardial Perfusion Assessment
Left ventricle functional analysis can be performed using coronary CT angiography (CTA) images. In recent years it has been proposed that CTA imaging might also be used for myocardial perfusion assessment, by visually looking for hypoattenuated regions that may correspond to hypoperfusion. Assigning a detected lesion to a specific myocardial segment requires significant effort while the clinician matches the American Heart Association (AHA) standard myocardial segments to the anatomy of each patient. This article presents an interactive tool which, based on the existence of a previous left ventricle segmentation, automatically matches the lesions detected by the clinician to a myocardial segment and provides feedback over the image regarding the myocardial segments with detected lesions and their severity.
- 28 February 2012
- Published by Wiley in Computer Graphics Forum
- Vol. 31 (1) , 146-159
Exploring Different Parameters to Assess Left Ventricle Global and Regional Functional Analysis from Coronary CT Angiography
Coronary CT angiography is widely used in clinical practice for the assessment of coronary artery disease. Several studies have shown that the same exam can also be used to assess left ventricle (LV) function. Even though coronary CT angiography provides data concerning multiple cardiac phases, along the cardiac cycle, LV function is usually evaluated using just the end‐systolic and end‐diastolic phases. This unused wealth of data, mostly due to its complexity and the lack of proper tools, has still to be explored to assess if further insight is possible regarding regional LV functional analysis. Furthermore, different parameters can be computed to characterize LV function and though some are well known by clinicians others still need to be tested concerning their value in clinical scenarios. Based on these premises, we present several parameters characterizing global and regional LV function, computed for several cardiac phases over one cardiac cycle. The data provided by the computed parameters is shown using a set of visualizations allowing synchronized visual exploration of the different data. The main purpose is to provide means for clinicians to explore the data and gather insight over their meaning and their correlation with each other and with diagnosis outcomes.
- 28 February 2012
- Published by Wiley in Computer Graphics Forum
- Vol. 31 (1) , 146-159
Exploring Different Parameters to Assess Left Ventricle Global and Regional Functional Analysis from Coronary CT Angiography
Coronary CT angiography is widely used in clinical practice for the assessment of coronary artery disease. Several studies have shown that the same exam can also be used to assess left ventricle (LV) function. Even though coronary CT angiography provides data concerning multiple cardiac phases, along the cardiac cycle, LV function is usually evaluated using just the end‐systolic and end‐diastolic phases. This unused wealth of data, mostly due to its complexity and the lack of proper tools, has still to be explored to assess if further insight is possible regarding regional LV functional analysis. Furthermore, different parameters can be computed to characterize LV function and though some are well known by clinicians others still need to be tested concerning their value in clinical scenarios. Based on these premises, we present several parameters characterizing global and regional LV function, computed for several cardiac phases over one cardiac cycle. The data provided by the computed parameters is shown using a set of visualizations allowing synchronized visual exploration of the different data. The main purpose is to provide means for clinicians to explore the data and gather insight over their meaning and their correlation with each other and with diagnosis outcomes.
- 30 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Computer Graphics and Applications
- Vol. 31 (5) , 14-17
Integrating User Studies into Computer Graphics-Related Courses
This paper presents computer graphics. Computer graphics and visualization are essentially about producing images for a target audience, be it the millions watching a new CG-animated movie or the small group of researchers trying to gain insight into the large amount of numerical data resulting from a scientific experiment. To ascertain the final images' effectiveness for their intended audience or the designed visualizations' accuracy and expressiveness, formal user studies are often essential. In human-computer interaction (HCI), such user studies play a similar fundamental role in evaluating the usability and applicability of interaction methods and metaphors for the various devices and software systems we use.
- 30 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Computer Graphics and Applications
- Vol. 31 (5) , 14-17
Integrating User Studies into Computer Graphics-Related Courses
This paper presents computer graphics. Computer graphics and visualization are essentially about producing images for a target audience, be it the millions watching a new CG-animated movie or the small group of researchers trying to gain insight into the large amount of numerical data resulting from a scientific experiment. To ascertain the final images' effectiveness for their intended audience or the designed visualizations' accuracy and expressiveness, formal user studies are often essential. In human-computer interaction (HCI), such user studies play a similar fundamental role in evaluating the usability and applicability of interaction methods and metaphors for the various devices and software systems we use.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 3411-3414
Inter-observer variability assessment of a left ventricle segmentation tool applied to 4D MDCT images of the heart
Multiple detector row computed tomography (MDCT) cardiac angiography provides a large amount of data concerning multiple cardiac phases which are not often considered. Segmentation is a first step towards exploring how this additional data can be used to perform left ventricle functional analysis or myocardial perfusion assessment. We present preliminary results regarding the assessment of inter-observer variability for a semi-automatic (multi-phase) segmentation tool for the left-ventricle.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 3411-3414
Inter-observer variability assessment of a left ventricle segmentation tool applied to 4D MDCT images of the heart
Multiple detector row computed tomography (MDCT) cardiac angiography provides a large amount of data concerning multiple cardiac phases which are not often considered. Segmentation is a first step towards exploring how this additional data can be used to perform left ventricle functional analysis or myocardial perfusion assessment. We present preliminary results regarding the assessment of inter-observer variability for a semi-automatic (multi-phase) segmentation tool for the left-ventricle.
- 1 April 2011
- Published by Elsevier in Computers & Graphics
- Vol. 35 (2) , 320-333
Using color in visualization: A survey
- 1 April 2011
- Published by Elsevier in Computers & Graphics
- Vol. 35 (2) , 320-333
Using color in visualization: A survey
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7963, 796326
A preparatory study to choose similarity metrics for left-ventricle segmentations comparison
In medical image processing and analysis it is often required to perform segmentation for quantitative measures of extent, volume and shape. The validation of new segmentation methods and tools usually implies comparing their various outputs among themselves (or with a ground truth), using similarity metrics. Several such metrics are proposed in the literature but it is important to select those which are relevant for a particular task as opposed to using all metrics and therefore avoiding additional computational cost and redundancy. A methodology is proposed which enables the assessment of how different similarity and discrepancy metrics behave for a particular comparison and the selection of those which provide relevant data.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7963, 796326
A preparatory study to choose similarity metrics for left-ventricle segmentations comparison
In medical image processing and analysis it is often required to perform segmentation for quantitative measures of extent, volume and shape. The validation of new segmentation methods and tools usually implies comparing their various outputs among themselves (or with a ground truth), using similarity metrics. Several such metrics are proposed in the literature but it is important to select those which are relevant for a particular task as opposed to using all metrics and therefore avoiding additional computational cost and redundancy. A methodology is proposed which enables the assessment of how different similarity and discrepancy metrics behave for a particular comparison and the selection of those which provide relevant data.
- 1 January 2011
- Published by Springer Nature
- p. 717-725
Myocardial Perfusion Analysis from Adenosine-Induced Stress MDCT
- 1 January 2011
- Published by Springer Nature
- p. 717-725
Myocardial Perfusion Analysis from Adenosine-Induced Stress MDCT