AAAmir Hossein Ansari

Amir Hossein Ansari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Amir Hossein Ansari has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feature matching as improved transfer learning technique for wearable EEG

    by Elisabeth R. M. Heremans, Huy Phan, Amir H. Ansari, Pascal Borzée, Bertien Buyse, Dries Testelmans, Maarten De Vos

    Objective: With the rapid rise of wearable sleep monitoring devices with non-conventional electrode configurations, there is a need for automated algorithms that can perform sleep staging on configurations with small amounts of labeled data. Transfer learning has the ability to adapt neural network weights from a source modality (e.g. standard electrode configuration) to a new target modality (e.g. non-conventional electrode configuration). Methods: We propose feature matching, a new transfer learning strategy as an alternative to the commonly used finetuning approach. This method consists of training a model with larger amounts of data from the source modality and few paired samples of source and target modality. For those paired samples, the model extracts features of the target modality, matching these to the features from the corresponding samples of the source modality. Results: We compare feature matching to finetuning for three different target domains, with two different neural network architectures, and with varying amounts of training data. Particularly on small cohorts (i.e. 2 - 5 labeled recordings in the non-conventional recording setting), feature matching systematically outperforms finetuning with mean relative differences in accuracy ranging from 0.4% to 4.7% for the different scenarios and datasets. Conclusion: Our findings suggest that feature matching outperforms finetuning as a transfer learning approach, especially in very low data regimes. Significance: As such, we conclude that feature matching is a promising new method for wearable sleep staging with novel devices.

  • A Deep Shared Multi-Scale Inception Network Enables Accurate Neonatal Quiet Sleep Detection With Limited EEG Channels

    by Amir H. Ansari, Kirubin Pillay, Anneleen Dereymaeker, Katrien Jansen, Sabine Van Huffel, Gunnar Naulaers, Maarten De Vos

    In this paper, we introduce a new variation of the Convolutional Neural Network Inception block, called Sinc, for sleep stage classification in premature newborn babies using electroencephalogram (EEG). In practice, there are many medical centres where only a limited number of EEG channels are recorded. Existing automated algorithms mainly use multi-channel EEGs which perform poorly when fewer numbers of channels are available. The proposed Sinc utilizes multi-scale analysis to place emphasis on the temporal EEG information to be less dependent on the number of EEG channels. In Sinc, we increase the receptive fields through Inception while by additionally sharing the filters that have similar receptive fields, overfitting is controlled and the number of trainable parameters dramatically reduced. To train and test this model, 96 longitudinal EEG recordings from 26 premature infants are used. The Sinc-based model significantly outperforms state-of-the-art neonatal quiet sleep detection algorithms, with mean Kappa 0.77 ± 0.01 (with 8-channel EEG) and 0.75 ± 0.01 (with a single bipolar channel EEG). This is the first study using Inception-based networks for EEG analysis that utilizes filter sharing to improve efficiency and trainability. The suggested network can successfully detect quiet sleep stages with even a single EEG channel making it more practical especially in the hospital setting where cerebral function monitoring is predominantly used.


  • A convolutional neural network outperforming state-of-the-art sleep staging algorithms for both preterm and term infants

    by Amir Hossein Ansari, Ofelie De Wel, Kirubin Pillay, Anneleen Dereymaeker, Katrien Jansen, Sabine Van Huffel, Gunnar Naulaers, Maarten De Vos

    Objective . To classify sleep states using electroencephalogram (EEG) that reliably works over a wide range of preterm ages, as well as term age. Approach . A convolutional neural network is developed to perform 2- and 4-class sleep classification in neonates. The network takes as input an 8-channel 30 s EEG segment and outputs the sleep state probabilities. Apart from simple downsampling of the input and smoothing of the output, the suggested network is an end-to-end algorithm that avoids the need for hand-crafted feature selection or complex pre/post processing steps. To train and test this method, 113 EEG recordings from 42 infants are used. Main results . For quiet sleep detection (the 2-class problem), mean kappa between the network estimate and the ground truth annotated by EEG human experts is 0.76. The sensitivity and specificity are 90% and 88%, respectively. For 4-class classification, mean kappa is 0.64. The averaged sensitivity and specificity (1 versus all) respectively equal 72% and 91%. The results outperform current state-of-the-art methods for which kappa ranges from 0.66 to 0.70 in preterm and from 0.51 to 0.61 in term infants, based on training and testing using the same database. Significance . The proposed method has the highest reported accuracy for EEG sleep state classification for both preterm and term age neonates.


  • Open Access

    Developing a Smart Proxy for Fluidized Bed Using Machine Learning

    by Amir Ansari

    Using fossil fuel which has been grown dramatically during the recent century, causes an increase in greenhouse gas emission. The global warming issue pushes the engineers toward the cleaner type of energy like Hydrogen. Coal gasification is one of the cheapest methods to obtain Hydrogen. Coal gasification is a special case of more general problem called fluidized bed. In order to design and optimize a gasification process, a deep understanding of multiphase flow in a gasifier is needed. MFiX is a commercial multi-phase flow simulator which has been used to simulate the gas and solid transport and reaction in the gasifier using Computational Fluid Dynamics (CFD). Although simulating multiphase flow using commercial CFD software has a lot of flexibilities, it is really time-consuming and some other way could be implemented to reduce the run time. The effort of this project is to develop an alternate method to perform the same analysis but with much lower computational cost. A data-driven approach is used to build a smart proxy by employing the knowledge of Artificial Intelligence (AI) and Data Mining (DM).;In this project, a smart proxy will be developed to study and analyze the fluidized bed problem. This smart proxy is then will be used as a replicate of the CFD solver, with a good accuracy and faster speed. This proxy needs an incredible less amount of time in comparison to the CFD solver with a reasonable error (less than 10%). MATLAB neural network toolbox is used for training.;The goal of this project is to prove the concept of using AI&DM; for computational fluid dynamics especially predicting multiphase flow. Multiphase flow has a wide range of application in petroleum industry such as multi-phase flow in the wellbore, surface lines, and hydraulic fracturing such as proppant transport in the hydraulic fracture. This project opens a new way to accelerate the fluid dynamics analysis and reduce its costs.


  • Open Access

    NeoGuard: a public, online learning platform for neonatal seizures

    by Amir Hossein Ansari, Perumpillichira Joseph Cherian, Alexander Caicedo, Anneleen Dereymaeker, Katrien Jansen, Leen De Wispelaere, Charlotte Dielman, Jan Vervisch, Paul Govaert, Maarten De Vos, et al.

    Seizures occur in the neonatal period more frequently than other periods of life and usually denote the presence of serious brain dysfunction. The gold standard for detecting seizures is based on visual inspection of continuous electroencephalogram (cEEG) complemented by video analysis, performed by an expert clinical neurophysiologist. Previous studies have reported varying degree of agreement between expert EEG readers, with kappa coefficients ranging from 0.4 to 0.85, calling into question the validity of visual scoring. This variability in visual scoring of neonatal seizures may be due to factors such as reader expertise and the nature of expressed patterns. One of the possible reasons for low inter-rater agreement is the absence of any benchmark for the EEG readers to be able to compare their opinions. One way to develop this is to use a shared multi-center neonatal seizure database and use the inputs from multiple experts. This will also improve the teaching of trainees, and help to avoid potential bias from a single expert's opinion. In this paper, we introduce and explain the NeoGuard public learning platform that can be used by trainees, tutors, and expert EEG readers who are interested to test their knowledge and learn from neonatal EEG-polygraphic segments scored by several expert EEG readers. For this platform, 1919 clinically relevant segments, totaling 280h, recorded from 71 term neonates in two centers, including a wide variety of seizures and artifacts were used. These segments were scored by 4 EEG readers from three different centers. Users of this platform can score an arbitrary number of segments and then test their scoring with the experts' opinions. The kappa and joint probability of agreement, is then shown as inter-rater agreement metrics between the user and each of the experts. The platform is publicly available at the NeoGuard website (www.neoguard.net).


  • Weighted Performance Metrics for Automatic Neonatal Seizure Detection Using Multiscored EEG Data

    by Amir Hossein Ansari, Perumpillichira Joseph Cherian, Alexander Caicedo Dorado, Katrien Jansen, Anneleen Dereymaeker, Leen De Wispelaere, Charlotte Dielman, Jan Vervisch, Paul Govaert, Maarten De Vos, et al.

    In neonatal intensive care units, there is a need for around the clock monitoring of EEG, especially for recognizing seizures. An automated seizure detector with an acceptable performance can partly fill this need. In order to develop a detector, an extensive dataset labeled by experts is needed. However, accurately defining neonatal seizures on EEG is a challenge, especially when seizure discharges do not meet exact definitions of repetitiveness or evolution in amplitude and frequency. When several readers score seizures independently, disagreement can be high. Commonly used metrics such as good detection rate (GDR) and false alarm rate (FAR) derived from data scored by multiple raters have their limitations. Therefore, new metrics are needed to measure the performance with respect to the different labels. In this paper, instead of defining the labels by consensus or majority voting, popular metrics including GDR, FAR, positive predictive value, sensitivity, specificity, and selectivity are fuzzily modified such that they can take different scores into account. To this end, 353 hours of EEG data containing seizures from 81 neonates were visually scored by a clinical neurophysiologist and then processed by an automated seizure detector. The scored seizures were mixed with false detections of an automated seizure detector and were relabeled by 3 independent EEG readers. Then, all labels were used in the proposed performance metrics and the result was compared with the majority voting technique and showed higher accuracy and robustness for the proposed metrics. Results were confirmed using a bootstrapping test.


  • Corrigendum to “Improved multi-stage neonatal seizure detection using a heuristic classifier and a data-driven post-processor” [Clin Neurophysiol 127 (2016) 3014–3024]

    by A.H. Ansari, P.J. Cherian, A. Dereymaeker, V. Matic, K. Jansen, L. De Wispelaere, C. Dielman, J. Vervisch, R.M. Swarte, P. Govaert, et al.


  • Improved multi-stage neonatal seizure detection using a heuristic classifier and a data-driven post-processor

    by A.H. Ansari, P.J. Cherian, A. Dereymaeker, V. Matic, K. Jansen, L. De Wispelaere, C. Dielman, J. Vervisch, R.M. Swarte, P. Govaert, et al.