Kazutoshi Kobayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kazutoshi Kobayashi has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Jun Furuta
Okayama Prefectural University
13 shared publications - Kodai Yamada
Graduate School of Science and Technology, Kyoto Institute of Technology, Kyoto, Japan
4 shared publications - Mitsunori Ebara
Graduate School of Science and Technology, Kyoto Institute of Technology, Kyoto, Japan
4 shared publications Yuto Tsukita
Graduate School of Science and Technology, Kyoto Institute of Technology, Kyoto, Japan
4 shared publications- Kentaro Kojima
Graduate School of Science and Technology, Kyoto Institute of Technology, Kyoto, Japan
3 shared publications - Makoto Sakai
Gunma University
3 shared publications
Latest Publications
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (8) , 2881-2890
Direct Measurements of Single-Event Burnout Current Induced by Neutron Irradiation in a 1200 V Fast Recovery Diode
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (8) , 2881-2890
Direct Measurements of Single-Event Burnout Current Induced by Neutron Irradiation in a 1200 V Fast Recovery Diode
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (10) , 3235-3246
A Measurement Method for Neutron-Induced Soft-Error Rates in Terrestrial Applications Using a Clinical Carbon Beam
Soft errors in terrestrial applications are typically evaluated by irradiating semiconductor chips with high-energy neutrons or protons. We propose an alternative method using clinical carbon beam facilities, where carbon ions are irradiated onto an acrylic block to generate secondary particles. Test chips are irradiated with neutrons emitted from the block, while charged particles with high Linear Energy Transfer (LET), such as alpha particles, are shielded by Pb blocks. To evaluate the shielding effect, we investigated the dependence of Single Event Upset (SEU) rates and Single Event Transient (SET) pulse widths on Pb thickness. The SEU rate stabilized at 4 cm, but the total SET rate at this thickness was 70% higher than that at 8 cm. This increase was mainly due to an increased number of pulses shorter than 245 ps, likely caused by direct ionization from charged particles. We then compared our method with white neutron irradiation using six types of 65 nm flip-flops to validate its effectiveness. The SEU rates showed the correlation coefficient of 0.98 and differed by less than 1%. SET pulses longer than 245 ps were similar in both cases, while shorter pulses occurred more often with white neutrons. This difference is attributed to a higher fraction of medium-energy neutrons in the white neutron spectrum. These findings indicate that clinical carbon beam facilities offer a practical alternative for soft-error evaluation, particularly when the contribution of medium-energy neutrons is limited.
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (10) , 3235-3246
A Measurement Method for Neutron-Induced Soft-Error Rates in Terrestrial Applications Using a Clinical Carbon Beam
Soft errors in terrestrial applications are typically evaluated by irradiating semiconductor chips with high-energy neutrons or protons. We propose an alternative method using clinical carbon beam facilities, where carbon ions are irradiated onto an acrylic block to generate secondary particles. Test chips are irradiated with neutrons emitted from the block, while charged particles with high Linear Energy Transfer (LET), such as alpha particles, are shielded by Pb blocks. To evaluate the shielding effect, we investigated the dependence of Single Event Upset (SEU) rates and Single Event Transient (SET) pulse widths on Pb thickness. The SEU rate stabilized at 4 cm, but the total SET rate at this thickness was 70% higher than that at 8 cm. This increase was mainly due to an increased number of pulses shorter than 245 ps, likely caused by direct ionization from charged particles. We then compared our method with white neutron irradiation using six types of 65 nm flip-flops to validate its effectiveness. The SEU rates showed the correlation coefficient of 0.98 and differed by less than 1%. SET pulses longer than 245 ps were similar in both cases, while shorter pulses occurred more often with white neutrons. This difference is attributed to a higher fraction of medium-energy neutrons in the white neutron spectrum. These findings indicate that clinical carbon beam facilities offer a practical alternative for soft-error evaluation, particularly when the contribution of medium-energy neutrons is limited.
- Open Access
- 20 January 2025
- Published by Association for Computing Machinery (ACM)
- p. 1420-1425
Physics-based Modeling to Extend a MOSFET Compact Model for Cryogenic Operation
This paper extends the low-temperature modeling capabilities of an industry-standard compact metal-oxide-semiconductor field-effect transistor (MOSFET) model by incorporating physics-based representations of cryogenic effects in semiconductors. Specifically, the incomplete dopant ionization effect is integrated into the bulk Fermi potential calculation of the compact model and applied as a threshold voltage shift in the formulation of Poisson's equation. Temperature-related models for bandgap energy, saturation velocity, and contact resistance at the source/drain regions are also enhanced. Using transistors fabricated with 22 nm process technology, we demonstrate that this consistent modeling approach accurately reproduces current-voltage and threshold voltage-temperature characteristics across a temperature range from 300 K to 4 K.
- 20 January 2025
- Published by Association for Computing Machinery (ACM)
- p. 1420-1425
Open AccessPhysics-based Modeling to Extend a MOSFET Compact Model for Cryogenic Operation
This paper extends the low-temperature modeling capabilities of an industry-standard compact metal-oxide-semiconductor field-effect transistor (MOSFET) model by incorporating physics-based representations of cryogenic effects in semiconductors. Specifically, the incomplete dopant ionization effect is integrated into the bulk Fermi potential calculation of the compact model and applied as a threshold voltage shift in the formulation of Poisson's equation. Temperature-related models for bandgap energy, saturation velocity, and contact resistance at the source/drain regions are also enhanced. Using transistors fabricated with 22 nm process technology, we demonstrate that this consistent modeling approach accurately reproduces current-voltage and threshold voltage-temperature characteristics across a temperature range from 300 K to 4 K.
- Open Access
- 26 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 157-162
The Contribution of Secondary Particles Following Carbon Ion Radiotherapy to Soft Errors in CIEDs
Introduction: While carbon ion radiotherapy is highly effective in cancer treatment, it has a high risk of causing soft error, which leads to malfunctions in cardiac implantable electrical devices (CIEDs). To predict the risk of malfunction prior to treatment, it is necessary to measure the reaction cross-sections and contributions to the soft error of secondary particles generated during treatments. Methods: A field-programmable gate array was used instead of CIEDs to measure soft errors by varying the energy spectrum of secondary particles. Results and discussion: The reaction cross-sections measured for each secondary particle were 3.0 × 10 −9 , 2.0 × 10 −9 , 1.3 × 10 −8 , and 1.5 × 10 −8 [cm 2 /Mb] for thermal neutrons, intermediate-energy neutrons, high-energy neutrons above 10 MeV, and protons, respectively. The contribution of high-energy neutrons was the largest among them. Our study indicates that to reduce the risk of soft errors, secure distance and appropriate irradiation directions are necessary.
- 26 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 157-162
Open AccessThe Contribution of Secondary Particles Following Carbon Ion Radiotherapy to Soft Errors in CIEDs
Introduction: While carbon ion radiotherapy is highly effective in cancer treatment, it has a high risk of causing soft error, which leads to malfunctions in cardiac implantable electrical devices (CIEDs). To predict the risk of malfunction prior to treatment, it is necessary to measure the reaction cross-sections and contributions to the soft error of secondary particles generated during treatments. Methods: A field-programmable gate array was used instead of CIEDs to measure soft errors by varying the energy spectrum of secondary particles. Results and discussion: The reaction cross-sections measured for each secondary particle were 3.0 × 10 −9 , 2.0 × 10 −9 , 1.3 × 10 −8 , and 1.5 × 10 −8 [cm 2 /Mb] for thermal neutrons, intermediate-energy neutrons, high-energy neutrons above 10 MeV, and protons, respectively. The contribution of high-energy neutrons was the largest among them. Our study indicates that to reduce the risk of soft errors, secure distance and appropriate irradiation directions are necessary.
- 24 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Scalable Highly Integrated Quantum Bit Error Correction System by Classical Electronics
In this presentation, I will introduce our project named "Development Scalable Highly Integrated Quantum Bit Error Correction System (Qubecs)." It belongs to one of the governmental-funded project called Moonshot Goal 6 "Realization of a fault-tolerant universal quantum computer that will revolutionize economy, industry, and security by 2050."
- 24 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Scalable Highly Integrated Quantum Bit Error Correction System by Classical Electronics
In this presentation, I will introduce our project named "Development Scalable Highly Integrated Quantum Bit Error Correction System (Qubecs)." It belongs to one of the governmental-funded project called Moonshot Goal 6 "Realization of a fault-tolerant universal quantum computer that will revolutionize economy, industry, and security by 2050."
- 7 September 2023
- Published by Japan Society of Applied Physics
Total Ionizing Dose Effect by Gamma-ray Irradiation and Recovery Phenomenon by Applying High Gate Bias to Commercial SiC Power MOSFETs
2023 International Conference on Solid State Devices and Materials ,Total Ionizing Dose Effect by Gamma-ray Irradiation and Recovery Phenomenon by Applying High Gate Bias to Commercial SiC Power MOSFETs
- 7 September 2023
- Published by Japan Society of Applied Physics
Total Ionizing Dose Effect by Gamma-ray Irradiation and Recovery Phenomenon by Applying High Gate Bias to Commercial SiC Power MOSFETs
2023 International Conference on Solid State Devices and Materials ,Total Ionizing Dose Effect by Gamma-ray Irradiation and Recovery Phenomenon by Applying High Gate Bias to Commercial SiC Power MOSFETs
- 7 September 2023
- Published by Japan Society of Applied Physics
Circuit-level Insight into Reliability Issues of Si-based Semiconductor Chips
2023 International Conference on Solid State Devices and Materials ,Circuit-level Insight into Reliability Issues of Si-based Semiconductor Chips
- 7 September 2023
- Published by Japan Society of Applied Physics
Circuit-level Insight into Reliability Issues of Si-based Semiconductor Chips
2023 International Conference on Solid State Devices and Materials ,Circuit-level Insight into Reliability Issues of Si-based Semiconductor Chips
- Open Access
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 1652-1657
A Terrestrial SER Estimation Methodology Based on Simulation Coupled With One-Time Neutron Irradiation Testing
Terrestrial soft error rates (SERs) are generally estimated by performing an experiment using spallation neutron beam with the energy spectrum being similar to that of the terrestrial neutrons or at least four measurements using various (quasi-)mono-energetic neutron and/or proton sources to determine the parameters of the Weibull function. We here propose a method to estimate the terrestrial SERs based on simulation coupled with one-time neutron irradiation testing which can be applied to various kinds of neutron sources. In this method, the dependences of single event upset (SEU) cross sections on the neutron energy and the critical charge are calculated by simulation using Particle and Heavy Ion Transport code System (PHITS). The critical charge is used as the only calibration parameter, which is adjusted to reproduce the SER measured by one-time neutron irradiation. The validity of our method is investigated for 65-nm bulk SRAMs with the measured data using various neutron sources in Japan. Our method generally provides the reasonable terrestrial SERs compared with those obtained by the Weibull function method. This result indicates the feasibility of evaluating the terrestrial SER using one of the various neutron sources available all over the world, including those not dedicated to SER measurement. We also investigate the necessity of the elaborated geometry of device under test (DUT) for the accuracy of the simulation. It is shown that detailed material compositions of DUT are not necessary in our method except when the one-time irradiation is performed using the neutron source that contains a high-quantity of low-energy neutrons below 8 MeV. Furthermore, we confirm that the configuration of the sensitive volume can be simplified without sacrificing the estimation accuracy. These simplifications in the simulation help to reduce the modeling and calculation cost in SER estimation.
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 1652-1657
Open AccessA Terrestrial SER Estimation Methodology Based on Simulation Coupled With One-Time Neutron Irradiation Testing
Terrestrial soft error rates (SERs) are generally estimated by performing an experiment using spallation neutron beam with the energy spectrum being similar to that of the terrestrial neutrons or at least four measurements using various (quasi-)mono-energetic neutron and/or proton sources to determine the parameters of the Weibull function. We here propose a method to estimate the terrestrial SERs based on simulation coupled with one-time neutron irradiation testing which can be applied to various kinds of neutron sources. In this method, the dependences of single event upset (SEU) cross sections on the neutron energy and the critical charge are calculated by simulation using Particle and Heavy Ion Transport code System (PHITS). The critical charge is used as the only calibration parameter, which is adjusted to reproduce the SER measured by one-time neutron irradiation. The validity of our method is investigated for 65-nm bulk SRAMs with the measured data using various neutron sources in Japan. Our method generally provides the reasonable terrestrial SERs compared with those obtained by the Weibull function method. This result indicates the feasibility of evaluating the terrestrial SER using one of the various neutron sources available all over the world, including those not dedicated to SER measurement. We also investigate the necessity of the elaborated geometry of device under test (DUT) for the accuracy of the simulation. It is shown that detailed material compositions of DUT are not necessary in our method except when the one-time irradiation is performed using the neutron source that contains a high-quantity of low-energy neutrons below 8 MeV. Furthermore, we confirm that the configuration of the sensitive volume can be simplified without sacrificing the estimation accuracy. These simplifications in the simulation help to reduce the modeling and calculation cost in SER estimation.
- Open Access
- 1 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 4, 357-366
A Three-Level GaN Driver for High False Turn-ON Tolerance With Minimal Reverse Conduction Loss
This paper presents a three-level gate driver for GaN HEMTs (Gallium Nitride High Electron Mobility Transistors) for high false turn-on tolerance and low reverse conduction loss during both dead time at turn-on and turn-off. The proposed gate driver reduces the reverse conduction loss by clamping between the gate and source terminals only during dead time. It has a capacitor which works as a negative voltage source and prevents from the false turn-on phenomenon. It operates only with a single voltage source and a PWM (Pulse Width Modulation) output signal. The proposed gate driver is implemented on a 48V-to-12V synchronous rectifier buck (SR-buck) converter and compared with other countermeasure methods for the false turn-on phenomenon. At the condition of 1 MHz, 30 ns dead time, and 120 W output power, the efficiencies of the proposed and conventional operations are 95.1% and 92.8% respectively. The margin between the threshold voltage and the peak of oscillated voltage of the proposed method becomes 1.3 times larger than that of the conventional method on average.
- 1 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 4, 357-366
Open AccessA Three-Level GaN Driver for High False Turn-ON Tolerance With Minimal Reverse Conduction Loss
This paper presents a three-level gate driver for GaN HEMTs (Gallium Nitride High Electron Mobility Transistors) for high false turn-on tolerance and low reverse conduction loss during both dead time at turn-on and turn-off. The proposed gate driver reduces the reverse conduction loss by clamping between the gate and source terminals only during dead time. It has a capacitor which works as a negative voltage source and prevents from the false turn-on phenomenon. It operates only with a single voltage source and a PWM (Pulse Width Modulation) output signal. The proposed gate driver is implemented on a 48V-to-12V synchronous rectifier buck (SR-buck) converter and compared with other countermeasure methods for the false turn-on phenomenon. At the condition of 1 MHz, 30 ns dead time, and 120 W output power, the efficiencies of the proposed and conventional operations are 95.1% and 92.8% respectively. The margin between the threshold voltage and the peak of oscillated voltage of the proposed method becomes 1.3 times larger than that of the conventional method on average.
- 30 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (7) , 2098-2108
Disturbance Aware Dynamic Power Reduction in Synchronous 2RW Dual-Port 8T SRAM by Self-Adjusting Wordline Pulse Timing
An effective design is proposed to reduce dynamic power consumption for a common clock synchronous two-read/ write (2RW) dual-port (DP) 8T static random access memory (SRAM). A self-adjusting wordline (WL) pulse timing control circuit is newly introduced for read/write operations. Row address inputs of ports A and B are compared in each cycle to detect the same row access or not. In the same row access from both ports, the disturbance should happen, which is an inherent mode of 2RW DP 8T SRAM. Then, the WL pulsewidth is extended to prevent the disturbance, while maintaining sufficient read/write margins. In the different row access, where there is no disturbance, the WL pulsewidth is shortened to reduce excessive bitline (BL) discharge power. Test chips are designed and fabricated to implement the proposed 2RW DP SRAM macros on 40-, 28-, and 7-nm Fin-FET technologies. Measured data show that read and write powers are reduced, respectively, by 6%–13% and 13%–28% with the proposed circuits. No speed degradation is found compared to conventional designs. Area overheads are found to be less than 1%.
- 30 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (7) , 2098-2108
Disturbance Aware Dynamic Power Reduction in Synchronous 2RW Dual-Port 8T SRAM by Self-Adjusting Wordline Pulse Timing
An effective design is proposed to reduce dynamic power consumption for a common clock synchronous two-read/ write (2RW) dual-port (DP) 8T static random access memory (SRAM). A self-adjusting wordline (WL) pulse timing control circuit is newly introduced for read/write operations. Row address inputs of ports A and B are compared in each cycle to detect the same row access or not. In the same row access from both ports, the disturbance should happen, which is an inherent mode of 2RW DP 8T SRAM. Then, the WL pulsewidth is extended to prevent the disturbance, while maintaining sufficient read/write margins. In the different row access, where there is no disturbance, the WL pulsewidth is shortened to reduce excessive bitline (BL) discharge power. Test chips are designed and fabricated to implement the proposed 2RW DP SRAM macros on 40-, 28-, and 7-nm Fin-FET technologies. Measured data show that read and write powers are reduced, respectively, by 6%–13% and 13%–28% with the proposed circuits. No speed degradation is found compared to conventional designs. Area overheads are found to be less than 1%.