Guowen Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Guowen Li has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Xudong Zhang
Radiotherapy Inpatient Ward II, The First Affiliated Hospital of Zhengzhou University, No. 1 Eastern Jianshe Road, Zhengzhou, 450000, Henan, China
3 shared publicationsBaohong Wang
Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan 450052, P.R. China
2 shared publicationsD. Xu
Radiotherapy Inpatient Ward II, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
2 shared publicationsDandan Xu
Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan 450052, P.R. China
2 shared publicationsFanyang Kong
Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan 450052, P.R. China
2 shared publicationsFei Jia
Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan 450052, P.R. China
2 shared publications
Latest Publications
- Open Access
- 11 September 2020
- Published by Springer Nature in Cancer Cell International
- Vol. 20 (1) , 1-7
Efficacy analysis of intraoperative radiotherapy in patients with early-stage breast cancer
Background: To analyze the clinical efficacy of intraoperative radiotherapy (IORT) after breast-conserving surgery (BCS) in patients with early-stage breast cancer (BC), and to investigate the relationship between its influencing factors and clinical efficacy and prognosis. Methods: A total of 73 patients with early-stage BC who underwent IORT after BCS in our hospital were selected in this research. Results: Kaplan-Meier survival analysis was used to analyze the related factors of BCS and IORT of disease-free survival (DFS) and overall survival (OS). It was found that only age (χ2 = 14.035, P = 0.003) was statistically positively correlated with the patient’s DFS, and local recurrence and metastasis rate and mortality were higher in patients over 70 years old. Log rank test was used to analyze multiple factors. Only the diameter of the applicator (χ2 = 70.378, P < 0.05) was statistically significant with wound complications, and the larger the diameter, the higher incidence of wound complications. The remaining risk factors did not increase the incidence of wound complications. COX multivariate analysis showed that age was an independent risk factor for DFS rate and the risk factor had no significant effect on the OS rate of patients undergoing IORT after BCS. Conclusions: IORT may be a safe form of treatment for the selected patients with early-stage BC, and can achieve satisfactory esthetic effect. Larger applicator diameters may increase the incidence of wound complications. Age is an independent risk factor for DFS in early-stage BC patients undergoing IORT after BCS.
- 11 September 2020
- Published by Springer Nature in Cancer Cell International
- Vol. 20 (1) , 1-7
Open AccessEfficacy analysis of intraoperative radiotherapy in patients with early-stage breast cancer
Background: To analyze the clinical efficacy of intraoperative radiotherapy (IORT) after breast-conserving surgery (BCS) in patients with early-stage breast cancer (BC), and to investigate the relationship between its influencing factors and clinical efficacy and prognosis. Methods: A total of 73 patients with early-stage BC who underwent IORT after BCS in our hospital were selected in this research. Results: Kaplan-Meier survival analysis was used to analyze the related factors of BCS and IORT of disease-free survival (DFS) and overall survival (OS). It was found that only age (χ2 = 14.035, P = 0.003) was statistically positively correlated with the patient’s DFS, and local recurrence and metastasis rate and mortality were higher in patients over 70 years old. Log rank test was used to analyze multiple factors. Only the diameter of the applicator (χ2 = 70.378, P < 0.05) was statistically significant with wound complications, and the larger the diameter, the higher incidence of wound complications. The remaining risk factors did not increase the incidence of wound complications. COX multivariate analysis showed that age was an independent risk factor for DFS rate and the risk factor had no significant effect on the OS rate of patients undergoing IORT after BCS. Conclusions: IORT may be a safe form of treatment for the selected patients with early-stage BC, and can achieve satisfactory esthetic effect. Larger applicator diameters may increase the incidence of wound complications. Age is an independent risk factor for DFS in early-stage BC patients undergoing IORT after BCS.
- 28 August 2020
- Published by Springer Nature in Clinical and Translational Oncology
- Vol. 23 (4) , 820-826
Magnetic resonance imaging evaluation of brain glioma before postoperative radiotherapy
Purpose To investigate the magnetic resonance imaging (MRI) images of brain glioma before postoperative radiotherapy, and to provide reference for the delineation of postoperative radiotherapy target area. Methods Retrospective analysis was performed on 106 cases of brain glioma confirmed by surgery and pathology in our hospital, including 70 cases of high-grade glioma (HGG) and 36 cases of low-grade glioma (LGG). The MRI images of the lesions within 1 month before and after surgery were analyzed, the apparent diffusion coefficient (ADC) values in the near and far tumor areas were measured, respectively, and the corresponding rADC values were calculated. Results The incidence of residual tumors of postoperative HGG and LGG was 0, 15.7% (0/36, 11/70), respectively. The incidence of postoperative reactive enhancement was 11.0% and 52.9% (4/36 and 37/70), respectively. About 30.6% and 81.4% (11/36 and 57/70) of patients with adjacent meningeal enhancement were found in the operative area. Conclusions The MRI images of HGG and LGG before postoperative radiotherapy had certain characteristics, providing a favorable guidance for the delineation of the target area of radiotherapy and the formulation of treatment plan.
- 28 August 2020
- Published by Springer Nature in Clinical and Translational Oncology
- Vol. 23 (4) , 820-826
Magnetic resonance imaging evaluation of brain glioma before postoperative radiotherapy
Purpose To investigate the magnetic resonance imaging (MRI) images of brain glioma before postoperative radiotherapy, and to provide reference for the delineation of postoperative radiotherapy target area. Methods Retrospective analysis was performed on 106 cases of brain glioma confirmed by surgery and pathology in our hospital, including 70 cases of high-grade glioma (HGG) and 36 cases of low-grade glioma (LGG). The MRI images of the lesions within 1 month before and after surgery were analyzed, the apparent diffusion coefficient (ADC) values in the near and far tumor areas were measured, respectively, and the corresponding rADC values were calculated. Results The incidence of residual tumors of postoperative HGG and LGG was 0, 15.7% (0/36, 11/70), respectively. The incidence of postoperative reactive enhancement was 11.0% and 52.9% (4/36 and 37/70), respectively. About 30.6% and 81.4% (11/36 and 57/70) of patients with adjacent meningeal enhancement were found in the operative area. Conclusions The MRI images of HGG and LGG before postoperative radiotherapy had certain characteristics, providing a favorable guidance for the delineation of the target area of radiotherapy and the formulation of treatment plan.
- Open Access
- 12 November 2018
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 16 (1) , 222
Application of red light phototherapy in the treatment of radioactive dermatitis in patients with head and neck cancer
To observe the effect of red light phototherapy (RLPT) on radioactive dermatitis (RD) caused by radiotherapy in patients with head and neck cancer (HNC). Sixty patients with HNC admitted to our hospital were randomly divided into experimental group and control group, 30 patients in each group. The control group received routine daily care during radiotherapy treatment. In the experimental group, in addition to routine daily care during radiotherapy treatment, photon therapy apparatus RLPT was added, 10 min/time, 2 times/day, and lasted until the end of radiotherapy. The pain and conditions of the patients’ skin were assessed daily, and the skin pain and dermatitis grades of the two groups were compared. In terms of the reaction degree of RD, experimental group was mainly grade 0–2, and control group was mainly grade 2–3, with a significant difference (P < 0.05). In terms of skin pain, according to the pain records at week 2, 3, and 4, the pain degree increased with time. However, the score of wound pain in experimental group was significantly lower than that in control group, and there was a significant difference between the two groups (P < 0.05). The application of RLPT in the treatment of RD can help accelerate wound healing and significantly shorten healing time. It can not only reduce wounds pain of patients, promote inflammation and ulcer healing, but also ensure the smooth progress of patients’ radiotherapy and improve their quality of lives, which is worth popularization and application in the clinical practice.
- 12 November 2018
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 16 (1) , 222
Open AccessApplication of red light phototherapy in the treatment of radioactive dermatitis in patients with head and neck cancer
To observe the effect of red light phototherapy (RLPT) on radioactive dermatitis (RD) caused by radiotherapy in patients with head and neck cancer (HNC). Sixty patients with HNC admitted to our hospital were randomly divided into experimental group and control group, 30 patients in each group. The control group received routine daily care during radiotherapy treatment. In the experimental group, in addition to routine daily care during radiotherapy treatment, photon therapy apparatus RLPT was added, 10 min/time, 2 times/day, and lasted until the end of radiotherapy. The pain and conditions of the patients’ skin were assessed daily, and the skin pain and dermatitis grades of the two groups were compared. In terms of the reaction degree of RD, experimental group was mainly grade 0–2, and control group was mainly grade 2–3, with a significant difference (P < 0.05). In terms of skin pain, according to the pain records at week 2, 3, and 4, the pain degree increased with time. However, the score of wound pain in experimental group was significantly lower than that in control group, and there was a significant difference between the two groups (P < 0.05). The application of RLPT in the treatment of RD can help accelerate wound healing and significantly shorten healing time. It can not only reduce wounds pain of patients, promote inflammation and ulcer healing, but also ensure the smooth progress of patients’ radiotherapy and improve their quality of lives, which is worth popularization and application in the clinical practice.
- 4 September 2018
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 24, 6151-6156
Use of a Smartphone Medical App Improves Complications and Quality of Life in Patients with Nasopharyngeal Carcinoma Who Underwent Radiotherapy and Chemotherapy
BACKGROUND:We explored the intervention effect of a smartphone medical app on complications and quality of life of patients with nasopharyngeal carcinoma who underwent radiotherapy and chemotherapy. MATERIAL AND METHODS:We divided 132 patients with n...
- 4 September 2018
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 24, 6151-6156
Use of a Smartphone Medical App Improves Complications and Quality of Life in Patients with Nasopharyngeal Carcinoma Who Underwent Radiotherapy and Chemotherapy
BACKGROUND:We explored the intervention effect of a smartphone medical app on complications and quality of life of patients with nasopharyngeal carcinoma who underwent radiotherapy and chemotherapy. MATERIAL AND METHODS:We divided 132 patients with n...
- Open Access
- 27 June 2018
- Published by Spandidos Publications in Molecular Medicine Reports
- Vol. 18 (3) , 2762-2770
Comparison of target volume and clinical effects of four radiotherapy plans for acute lymphoblastic leukemia prior to hematopoietic stem cell transplantation
The present study aimed to investigate the variations in target volume, clinical reaction and transplantation effects of helical tomotherapy (HT)‑total body irradiation (TBI), HT‑total marrow and lymphatic irradiation (TMLI), intensity modulated radiotherapy (IMRT)‑TBI and IMRT‑TMLI within patients with acute lymphoblastic leukemia (ALL). A total of 18 patients with ALL were treated with the four aforementioned radiotherapy plans prior to hematopoietic stem cell transplantation. A planned prescribed dose of 12 Gy/6 Frequency was administered to determine planning target volume (PTV). Dosimetry evaluation indexes in PTV and organs at risk were analyzed. Comparison of clinical untoward effects and the results of transplantation among the four plans were performed. The conformity index of HT plans was significantly increased compared with those in IMRT plans. The mean dose (D) to the lung and volume ratio of target volume occupied by 5 Gy (V5) in TMLI plans were lower compared with TBI plans. Doses to organs were controlled within the normal range. Dmax, Dmean and V5 of bilateral lungs and Dmax and Dmean of bilateral crystalline lens in IMRT plans were significantly higher compared with HT plans. There were no significant differences in untoward effects among the four plans. Subsequent to symptomatic treatments with antiemetic, antidiarrheal and fluid infusion, untoward effects improved, and all patients demonstrated tolerance to these therapies. A total of six patients treated with HT‑TBI revealed complete and successful transplantation; however, one patient following transplantation suffered from severe rejection and had succumbed to mortality due to severe infection. Patients treated with HT‑TMLI, IMRT‑TBI and IMRT‑TMLI completed successful transplantation and no rejection responses were observed. Conformity of HT plans are higher than that of IMRT plans. The four radiotherapy plans exhibit similar clinical untoward effects and the same transplantation success rate. HT‑TMLI is more feasible in dosimetry compared with HT‑TBI, IMRT‑TBI and IMRT‑TMLI, which require further long‑term observation.
- 27 June 2018
- Published by Spandidos Publications in Molecular Medicine Reports
- Vol. 18 (3) , 2762-2770
Open AccessComparison of target volume and clinical effects of four radiotherapy plans for acute lymphoblastic leukemia prior to hematopoietic stem cell transplantation
The present study aimed to investigate the variations in target volume, clinical reaction and transplantation effects of helical tomotherapy (HT)‑total body irradiation (TBI), HT‑total marrow and lymphatic irradiation (TMLI), intensity modulated radiotherapy (IMRT)‑TBI and IMRT‑TMLI within patients with acute lymphoblastic leukemia (ALL). A total of 18 patients with ALL were treated with the four aforementioned radiotherapy plans prior to hematopoietic stem cell transplantation. A planned prescribed dose of 12 Gy/6 Frequency was administered to determine planning target volume (PTV). Dosimetry evaluation indexes in PTV and organs at risk were analyzed. Comparison of clinical untoward effects and the results of transplantation among the four plans were performed. The conformity index of HT plans was significantly increased compared with those in IMRT plans. The mean dose (D) to the lung and volume ratio of target volume occupied by 5 Gy (V5) in TMLI plans were lower compared with TBI plans. Doses to organs were controlled within the normal range. Dmax, Dmean and V5 of bilateral lungs and Dmax and Dmean of bilateral crystalline lens in IMRT plans were significantly higher compared with HT plans. There were no significant differences in untoward effects among the four plans. Subsequent to symptomatic treatments with antiemetic, antidiarrheal and fluid infusion, untoward effects improved, and all patients demonstrated tolerance to these therapies. A total of six patients treated with HT‑TBI revealed complete and successful transplantation; however, one patient following transplantation suffered from severe rejection and had succumbed to mortality due to severe infection. Patients treated with HT‑TMLI, IMRT‑TBI and IMRT‑TMLI completed successful transplantation and no rejection responses were observed. Conformity of HT plans are higher than that of IMRT plans. The four radiotherapy plans exhibit similar clinical untoward effects and the same transplantation success rate. HT‑TMLI is more feasible in dosimetry compared with HT‑TBI, IMRT‑TBI and IMRT‑TMLI, which require further long‑term observation.
- 5 April 2018
- Published by Springer Nature in Clinical and Translational Oncology
- Vol. 20 (10) , 1329-1336
Dosimetry study of 18F-FMISO + PET/CT hypoxia imaging guidance on intensity-modulated radiation therapy for non-small cell lung cancer
This study was to evaluate the feasibility of simultaneous integrated boost on tumor hypoxia area by studying the dosimetric change of hypoxia imaging guidance on intensity-modulated radiation therapy for non-small cell lung cancer (NSCLC).
- 5 April 2018
- Published by Springer Nature in Clinical and Translational Oncology
- Vol. 20 (10) , 1329-1336
Dosimetry study of 18F-FMISO + PET/CT hypoxia imaging guidance on intensity-modulated radiation therapy for non-small cell lung cancer
This study was to evaluate the feasibility of simultaneous integrated boost on tumor hypoxia area by studying the dosimetric change of hypoxia imaging guidance on intensity-modulated radiation therapy for non-small cell lung cancer (NSCLC).
- Open Access
- 26 December 2017
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 16 (6) , 1266-1271
Dosimetric Study and Neurocognitive Function of Hippocampal-Sparing Whole-Brain Radiotherapy
Objective: To investigate the feasibility of hippocampal-sparing whole-brain radiotherapy and reduction in neurocognitive function impairment after radiotherapy. Methods: Forty-three patients with brain metastases were selected. Whole-brain radiotherapy was performed in 22 patients, with 3-dimensional conformal radiotherapy in parallel opposed fields. Twenty-one patients had significant difference. Planning parameter values and neurocognitive function scores in 2 groups were statistically analyzed. Results: Homogeneity index in the 3-dimensional conformal radiotherapy group and tomotherapy group was 0.12 ± 0.02 and 0.36 ± 0.03, respectively, with a significant difference ( P < .05). The homogeneity of target doses was better in the tomotherapy group than in the 3-dimensional conformal radiotherapy group. There was a statistical significance in Dmean and Dmax between the 2 groups ( P < .05). The dose in hippocampal was less in the tomotherapy group than in the other group. Dmean and Dmax of the left hippocampus declined to 20.14% and 35.39% of prescription dose, respectively, and Dmean and Dmax of the right hippocampus declined to 19.92% and 35.14% of prescription dose, respectively. Neurocognitive function score between the 2 groups before treatment and 1 month after treatment had no significant difference ( P > .05), while there was a significant difference in 3 and 6 months after treatment ( P < .05). Neurocognitive function score was higher in the tomotherapy group than in the other group. No level III or above adverse reactions were observed. Conclusions: Hippocampal-sparing whole-brain radiotherapy in brain metastases treatment is feasible. Homogeneity index value is higher in the tomotherapy group than in the 3-dimensional conformal radiotherapy group. All V95% in the 2 groups meet the requirements. Hippocampal sparing could avoid neurocognitive function impairment to some extent.
- 26 December 2017
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 16 (6) , 1266-1271
Open AccessDosimetric Study and Neurocognitive Function of Hippocampal-Sparing Whole-Brain Radiotherapy
Objective: To investigate the feasibility of hippocampal-sparing whole-brain radiotherapy and reduction in neurocognitive function impairment after radiotherapy. Methods: Forty-three patients with brain metastases were selected. Whole-brain radiotherapy was performed in 22 patients, with 3-dimensional conformal radiotherapy in parallel opposed fields. Twenty-one patients had significant difference. Planning parameter values and neurocognitive function scores in 2 groups were statistically analyzed. Results: Homogeneity index in the 3-dimensional conformal radiotherapy group and tomotherapy group was 0.12 ± 0.02 and 0.36 ± 0.03, respectively, with a significant difference ( P < .05). The homogeneity of target doses was better in the tomotherapy group than in the 3-dimensional conformal radiotherapy group. There was a statistical significance in Dmean and Dmax between the 2 groups ( P < .05). The dose in hippocampal was less in the tomotherapy group than in the other group. Dmean and Dmax of the left hippocampus declined to 20.14% and 35.39% of prescription dose, respectively, and Dmean and Dmax of the right hippocampus declined to 19.92% and 35.14% of prescription dose, respectively. Neurocognitive function score between the 2 groups before treatment and 1 month after treatment had no significant difference ( P > .05), while there was a significant difference in 3 and 6 months after treatment ( P < .05). Neurocognitive function score was higher in the tomotherapy group than in the other group. No level III or above adverse reactions were observed. Conclusions: Hippocampal-sparing whole-brain radiotherapy in brain metastases treatment is feasible. Homogeneity index value is higher in the tomotherapy group than in the 3-dimensional conformal radiotherapy group. All V95% in the 2 groups meet the requirements. Hippocampal sparing could avoid neurocognitive function impairment to some extent.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 589-591
A new fluorescent vesicular sensor for saccharides based on boronic acid-diol recognition on the interfaces of vesicles
A novel amphiphile containing two functional groups of both naphthalene and phenylboronic acid, p-((5-dodecyloxy-1-oxy) naphthalene) methyl-phenylboronic acid (DNMPBA), has been synthesized. The amphiphile has self-organized into vesicles in the selective solution of THF/water (phi=0.6) buffered at pH 6.86. The Tc of the vesicles from crystal to liquid crystal is 56.8degC. Addition of saccharides to the vesicular solution, the fluorescent intensities of naphthalene in DNMPBA vesicles centred at 345 nm increase dramatically with increasing concentration of saccharides. The changed tendency for fluorescent intensities of the DMNPAB vesicles with saccharides is similar to the other systems reported in literature to favor the binding with fructose over glucose and maltose. It is ascribed to boronic ester formation which might diminish the photoinduced electron transfer (PET) progress to induce fluorescence retrieval and, therefore, increase the fluorescence intensity. The vesicular sensor through the interactions between boronic acid and saccharides displayed at a biomimetic membrane interface can be detected by means of fluorescence intensities. The results suggest that the fluorescent vesicles might be used as biosensors to determine saccharides.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 589-591
A new fluorescent vesicular sensor for saccharides based on boronic acid-diol recognition on the interfaces of vesicles
A novel amphiphile containing two functional groups of both naphthalene and phenylboronic acid, p-((5-dodecyloxy-1-oxy) naphthalene) methyl-phenylboronic acid (DNMPBA), has been synthesized. The amphiphile has self-organized into vesicles in the selective solution of THF/water (phi=0.6) buffered at pH 6.86. The Tc of the vesicles from crystal to liquid crystal is 56.8degC. Addition of saccharides to the vesicular solution, the fluorescent intensities of naphthalene in DNMPBA vesicles centred at 345 nm increase dramatically with increasing concentration of saccharides. The changed tendency for fluorescent intensities of the DMNPAB vesicles with saccharides is similar to the other systems reported in literature to favor the binding with fructose over glucose and maltose. It is ascribed to boronic ester formation which might diminish the photoinduced electron transfer (PET) progress to induce fluorescence retrieval and, therefore, increase the fluorescence intensity. The vesicular sensor through the interactions between boronic acid and saccharides displayed at a biomimetic membrane interface can be detected by means of fluorescence intensities. The results suggest that the fluorescent vesicles might be used as biosensors to determine saccharides.
- 1 March 1997
- Published by Taylor & Francis in Molecular Crystals and Liquid Crystals
- Vol. 294 (1) , 181-184
Preparation and Spectroscopic Study of Langmuir-Blodgett Films of 4-[4(-(4(-Decyloxy Phenylazo) Naphthloxy] Butyl Trimethylamimonium Dextran Sulfate
4-[4(-(4(-decyloxy phenylazo) naphthloxy] butyltrimethylammonium bromide can form a stable monolayer on the subphase of an aqueous sodium dextran sulfate solution. Infrared transmission, reflection-absorption and ultraviolet-visible spectra have been measured for the one-and multi-layer LB films to study the molecular orientation and aggregation in the films. It was found that the title compound does not form molecular aggregation in the LB films. The alkyl tail is nearly perpendicular to the substrate surface and adopts largely trans-zigzag conformation.
- 1 March 1997
- Published by Taylor & Francis in Molecular Crystals and Liquid Crystals
- Vol. 294 (1) , 181-184
Preparation and Spectroscopic Study of Langmuir-Blodgett Films of 4-[4(-(4(-Decyloxy Phenylazo) Naphthloxy] Butyl Trimethylamimonium Dextran Sulfate
4-[4(-(4(-decyloxy phenylazo) naphthloxy] butyltrimethylammonium bromide can form a stable monolayer on the subphase of an aqueous sodium dextran sulfate solution. Infrared transmission, reflection-absorption and ultraviolet-visible spectra have been measured for the one-and multi-layer LB films to study the molecular orientation and aggregation in the films. It was found that the title compound does not form molecular aggregation in the LB films. The alkyl tail is nearly perpendicular to the substrate surface and adopts largely trans-zigzag conformation.