TWTobias Weissgerber

Tobias Weissgerber

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tobias Weissgerber has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automated, Radiation-Free Detection of Cochlear Implant Electrode Array Migration Using Routine Impedance Telemetry

    by Stephan Schraivogel, Tobias Rader, Tobias Weissgerber, Marco Caversaccio, Wilhelm Wimmer

    Electrode array migration is a rare condition after cochlear implantation that can impair auditory outcomes but often remains undetected during routine follow-up. We evaluated the clinical utility of an electrical impedance-based, machine learning method for detecting postoperative electrode array migration using routinely acquired telemetry data. In this retrospective analysis, we evaluated impedance telemetry data from 32 cochlear implant cases (16 with radiologically confirmed electrode array migration and 16 matched stable controls). A random forest regression model was trained to estimate the longitudinal position of the most basal electrode based on transimpedance matrices, cochlear dimensions, and implant parameters. Model predictions were compared against radiological ground truth, and migration was detected using a defined threshold of 1 mm. Electrode array migration was detected with a sensitivity of 88% and a specificity of 100%. Migration was identified in clinically inconspicuous cases with largely unremarkable impedance trajectories and across long-term follow-up. In addition to electrode emigration, postoperative imaging revealed non-surgically induced electrode immigration, a phenomenon not previously reported. Impedance-based machine learning could enable radiation-free detection of cochlear implant electrode array migration during routine follow-up. This low-burden approach has the potential to support earlier clinical review and intervention, particularly in pediatric patients. While this study represents a first proof-of-concept, validation on larger cohorts could allow this low-burden approach to be readily integrated into standard post-implantation care. The approach could enable earlier intervention and reduce revision surgeries in pediatric CI patients.

  • Open Access

    Impact of visual mouth image presentation on speech perception in noise in normal hearing subjects and cochlear implant users

    by Anna Maria Schneider, Timo Stöver, Tobias Weissgerber

    This study investigated the impact of visual speech cues on speech perception in noise and subjective listening effort in cochlear implant (CI) users compared with normal-hearing (NH) individuals. Furthermore, the study compared visual information presented either by a computer-generated avatar or by video recordings of a real speaker. Thirteen NH participants and twelve bilateral CI users completed the Oldenburg Sentence Test (OLSA) in six conditions: auditory‑only, visual‑only, and audiovisual presentations using either video recordings (female speaker) or a computer‑animated avatar (male speaker). Speech reception thresholds (SRTs) in noise and subjective listening effort (LE) were measured. Visual‑only lipreading performance and self‑assessed lipreading skills were also recorded. Video‑based audiovisual presentation significantly improved speech perception compared with audio‑only presentation (NH: 1.6 dB; CI: 3.5 dB). CI users demonstrated substantially higher lipreading scores than NH participants (51% vs. 28%), and lipreading performance strongly correlated with self‑reported ability. Despite SRT improvements, audiovisual presentation yielded only marginal reductions in listening effort for CI users and none for NH participants. In contrast, the computer‑animated avatar provided no measurable audiovisual benefit for speech perception or listening effort in either group. Real‑speaker video recordings considerably enhance audiovisual speech perception in both NH individuals and CI users, particularly benefiting CI listeners. However, reductions in listening effort were minimal, underscoring the dissociation between speech perception and perceived listening effort. Incorporating audiovisual measures may improve ecological validity in clinical assessment of CI outcomes.

  • Open Access

    Functional hearing and low frequency hearing preservation after cochlear implant surgery is achievable with FLEX electrode arrays: Real world evidence from the MEHS Registry

    by Uwe Baumann, Tobias Weissgerber, Andreas Radeloff, Ilona Anderson, Karin A. Koinig, Magdalena Breu, Stefano Morettini, Vera Lohnherr, Joachim Müller, Daniel Polterauer-Neuling

    This study uses data from the MED-EL Hearing Solutions (MEHS) multicenter registry to examine the impact of a series of flexible lateral wall electrode arrays on postoperative low frequency hearing preservation (LFHP) of cochlear implant (CI) users. Participants were members of the MEHS registry who had received a MED-EL CI with a FLEX electrode array. LFHP was evaluated using 2 formulae: the Vienna Consensus (VC), which assesses hearing preservation at 250‒1000 Hz; and the Minimum Reporting Standards for Adult Cochlear American Academy of Otolaryngology—Head and Neck Surgery (AAO), which assesses hearing preservation at 125‒500 Hz. LFHP was assessed via air conduction preoperatively and between 6 and 36 months postoperatively. LFHP was achievable with all the FLEX arrays evaluated, regardless of length. With the VC, 60% of ears (n = 95) had complete or partial LFHP at 6‒12 months postoperatively and 68.4% (n = 19) had complete or partial LFHP at 24‒36 months postoperatively. With the AAO, 43.4% of ears (n = 83) had LFHP at 6‒12 months postoperatively and 84.2% (n = 19) had functional low frequency residual hearing at 24‒36 months postoperatively. In conclusion, implantation with FLEX electrode arrays can preserve functional low-frequency residual hearing up to three years after implantation. The MEHS multicenter registry appears to be a valuable tool for collecting large amounts of real-world data from CI users despite challenges in harvesting usable data.

  • Open Access

    Impact of Reverberation on Speech Perception in Noise in Bimodal/Bilateral Cochlear Implant Users with and without Residual Hearing

    by Clara König, Uwe Baumann, Timo Stöver, Tobias Weissgerber

    (1) Background: The aim of the present study was to assess the impact of reverberation on speech perception in noise and spatial release from masking (SRM) in bimodal or bilateral cochlear implant (CI) users and CI subjects with low-frequency residual hearing using combined electric–acoustic stimulation (EAS). (2) Methods: In total, 10 bimodal, 14 bilateral CI users and 14 EAS users, and 17 normal hearing (NH) controls, took part in the study. Speech reception thresholds (SRTs) in unmodulated noise were assessed in co-located masker condition (S0N0) with a spatial separation of speech and noise (S0N60) in both free-field and loudspeaker-based room simulation for two different reverberation times. (3) Results: There was a significant detrimental effect of reverberation on SRTs and SRM in all subject groups. A significant difference between the NH group and all the CI/EAS groups was found. There was no significant difference in SRTs between any CI and EAS group. Only NH subjects achieved spatial release from masking in reverberation, whereas no beneficial effect of spatial separation of speech and noise was found in any CI/EAS group. (4) Conclusions: The subject group with electric–acoustic stimulation did not yield a superior outcome in terms of speech perception in noise under reverberation when the noise was presented towards the better hearing ear.


  • Open Access

    Thematic coverage and readability of online patient information on cochlear implant care

    by Anna Levi, Martin Leinung, Silke Helbig, Daniela Guderian, Christian Issing, Tobias Weissgerber, Maria Hartmann, Timo Stöver, Andreas G. Loth

    Introduction: The treatment of patients with a cochlear implant (CI) is usually an elective, complex and interdisciplinary process. As an important source of information, patients often access the internet prior to treatment. The quality of internet-based information regarding thematic coverage has not yet been analysed in detail. Therefore, the aim of this study was to analyse the information on CI care available on the internet regarding its thematic coverage and readability. Material methods: Eight search phrases related to CI care were defined as part of the study. A checklist for completeness of thematic coverage was then created for each search phrase. The current German CI clinical practice guideline and the white paper on CI care in Germany were used as a basis. As a further parameter, readability was assessed using Flesch Reading Ease Scores. The search phrases were used for an internet search with Google. The first ten results were then analysed with regard to thematic coverage, readability and the provider of the website. Results: A total of 80 websites were identified, which were set up by 54 different providers (16 providers were found in multiple entries) from eight different provider groups. The average completeness of thematic coverage was 41.6 ± 28.2%. Readability according to the Flesch Reading Ease Score was categorised as "hard to read" on average (34.7 ± 14.2 points, range: 0–72). There was a negative statistically significant correlation between the thematic coverage of content and readability (Spearman's rank correlation: r = − 0.413, p = 0.00014). Summary: The completeness of thematic coverage of information on CI care available on the internet was highly heterogeneous and had a significant negative correlation with the readability. This result should be taken into account by both the providers of internet information and by patients when using internet-based information on CI care and help to further improve the quality of web-based information.


  • Open Access

    Outcome Prediction of Speech Perception in Quiet and in Noise for Cochlear Implant Candidates Based on Pre-Operative Measures

    by Tobias Weissgerber, Marcel Löschner, Timo Stöver, Uwe Baumann

    (1) Background: The fitting of cochlear implants (CI) is an established treatment, even in cases with considerable residual hearing but insufficient speech perception. The aim of this study was to evaluate a prediction model for speech in quiet and to provide reference data and a predictive model for postoperative speech perception in noise (SPiN) after CI provision. (2) Methods: CI candidates with substantial residual hearing (either in hearing threshold or in word recognition scores) were included in a retrospective analysis (n = 87). Speech perception scores in quiet 12 months post-surgery were compared with the predicted scores. A generalized linear model was fitted to speech reception thresholds (SRTs) after CI fitting to identify predictive variables for SPiN. (3) Results: About two-thirds of the recipients achieved the expected outcome in quiet or were better than expected. The mean absolute error of the prediction was 13.5 percentage points. Age at implantation was the only predictive factor for SPiN showing a significant correlation (r = 0.354; p = 0.007). (4) Conclusions: Outcome prediction accuracy for speech in quiet was comparable to previous studies. For CI recipients in the included study population, the SPiN outcome could be predicted only based on the factor age.


  • Open Access

    Comparison of hearing performance in patients with borderline indication for active middle ear or cochlear implants: clinical outcomes to guide preoperative counseling and decision making

    by Constanze Herr, Timo Stöver, Uwe Baumann, Tobias Weissgerber

    Purpose: The aim of the presented study was to compare the audiological benefit achieved in cochlear implant (CI) patients who, in principle, could still have been treated with an active middle ear implant (AMEI) with a group of AMEI users. Methods: Results of 20 CI patients with a pure-tone average (PTA) of 70 dB HL prior to surgery were compared with a group of 12 subjects treated with a Vibrant Soundbridge (VSB). Pre-surgical comparison included PTA for air conduction and bone conduction, maximum speech recognition score for monosyllabic words (WRSmax), and aided monosyllabic word recognition at 65 dB SPL. One year after surgery, aided monosyllabic speech recognition score at 65 dB SPL was compared. Results: Mean PTA for air conduction in the VSB group was significantly lower than in the CI group (4.8 dB, Z = − 2.011, p < 0.05). Mean PTA for bone conduction in the VSB group was also significantly lower than in the CI group (23.4 dB, Z = − 4.673, p < 0.001). WRSmax in the VSB group was significantly better than in the CI group (40.7%, Z = − 3.705, p < 0.001). One year after treatment, there was no significant difference in aided speech perception in quiet between both subject groups. Conclusion: Comparison of the two methods showed equivalent results for both treatments in subjects with a borderline indication. Not only pure-tone audiometry results but, particularly, speech perception scores pre-surgery should be taken into account in preoperative counseling.


  • Open Access

    Speech perception in modulated noise assessed in bimodal CI users

    by Tobias Weißgerber, Timo Stöver, Uwe Baumann

    Although good speech perception in quiet is achievable with cochlear implants (CIs), speech perception in noise is severely impaired compared to normal hea


  • Open Access

    Speech perception in modulated noise assessed in bimodal CI users—German version

    by Tobias Weißgerber, Timo Stöver, Uwe Baumann

    Zusammenfassung Hintergrund Obwohl bei einer Versorgung mit Cochleaimplantaten (CI) ein gutes Sprachverstehen in Ruhe erreichbar ist, ist das Sprachverstehen im Störgeräusch gegenüber Normalhörenden (NH) stark beeinträchtigt. Bei einer bimodalen CI-Versorgung mit Hörgerät (HG) im Gegenohr beeinflusst das akustische Restgehör das Sprachverstehen im Störgeräusch. Fragestellung Ziel der Arbeit war es, das Sprachverstehen im Störgeräusch bei bimodaler CI-Nutzung zu untersuchen und mit gleichaltrigen HG-Tragenden und Menschen ohne subjektive Hörminderung sowie einer jungen NH-Gruppe zu vergleichen. Material und Methoden Es nahmen 19 bimodale CI-Tragende, 39 HG-Tragende und 40 subjektive Normalhörende der Altersklasse 60–90 Jahre und 14 junge NH teil. Die Sprachverständlichkeitsschwelle (SVS) im Störgeräusch wurde mit dem Oldenburger Satztest adaptiv für die 2 räumlichen Testkonditionen S0N0 (Sprache und Störgeräusch von vorne) und „multisource-noise field“ (MSNF, Sprache von vorne, 4 räumlich verteilte Störgeräuschquellen) jeweils im zeitlich kontinuierlichen Oldenburger Rauschen (Olnoise) und im zeitlich modulierten Fastl-Noise (amplitudenmoduliertes, sprachsimulierendes, fluktuierendes Störgeräusch nach Fastl) bestimmt. Ergebnisse Mit zunehmender Hörminderung wurde die mediane SVS in allen Bedingungen signifikant schlechter. In der Testbedingung S0N0 war die SVS der CI-Gruppe im Olnoise um 5,6 dB und im Fastl-Noise um 22,5 dB schlechter als die der jungen NH-Gruppe (mittleres Alter: 26,4 Jahre) im MSNF betrugen die Unterschiede 6,6 dB (Olnoise) bzw. 17,3 dB (Fastl-Noise). In der jungen NH-Gruppe verbesserte sich die mediane SVS in der Bedingung S0N0 durch Lückenhören um 11 dB, in der älteren NH-Gruppe um nur noch 3,1 dB. In der HG-Gruppe und der bimodal versorgten CI-Gruppe gab es kein Lückenhören, und die SVS war im Fastl-Noise schlechter als im Olnoise. Schlussfolgerung Bei fortschreitender Hörminderung wird das Sprachverstehen im modulierten Störgeräusch sogar stärker beeinträchtigt als im kontinuierlichen Störgeräusch.


  • Open Access

    Impact of processing-latency induced interaural delay and level discrepancy on sensitivity to interaural level differences in cochlear implant users

    by Monika Körtje, Timo Stöver, Uwe Baumann, Tobias Weissgerber

    Purpose: This study investigated whether an interaural delay, e.g. caused by the processing latency of a hearing device, can affect sensitivity to interaural level differences (ILDs) in normal hearing subjects or cochlear implant (CI) users with contralateral normal hearing (SSD-CI). Methods: Sensitivity to ILD was measured in 10 SSD-CI subjects and in 24 normal hearing subjects. The stimulus was a noise burst presented via headphones and via a direct cable connection (CI). ILD sensitivity was measured for different interaural delays in the range induced by hearing devices. ILD sensitivity was correlated with results obtained in a sound localization task using seven loudspeakers in the frontal horizontal plane. Results: In the normal hearing subjects the sensitivity to interaural level differences deteriorated significantly with increasing interaural delays. In the CI group, no significant effect of interaural delays on ILD sensitivity was found. The NH subjects were significantly more sensitive to ILDs. The mean localization error in the CI group was 10.8° higher than in the normal hearing group. No correlation between sound localization ability and ILD sensitivity was found. Conclusion: Interaural delays influence the perception of ILDs. For normal hearing subjects a significant decrement in sensitivity to ILD was measured. The effect could not be confirmed in the tested SSD-CI group, probably due to a small subject group with large variations. The temporal matching of the two sides may be beneficial for ILD processing and thus sound localization for CI patients. However, further studies are needed for verification.