CSCarl J. Snyder

Carl J. Snyder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carl J. Snyder has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-Spatial- and High-Temporal-Resolution Dynamic Contrast-enhanced MR Breast Imaging with Sweep Imaging with Fourier Transformation: A Pilot Study

    by Curtis A. Corum, John C. Benson, Djaudat Idiyatullin, Angela L. Snyder, Carl J. Snyder, Diane Hutter, Lenore I. Everson, Lynn E. Eberly, Michael T. Nelson, Michael Garwood

    Purpose To report the results of sweep imaging with Fourier transformation (SWIFT) magnetic resonance (MR) imaging for diagnostic breast imaging. Materials and Methods Informed consent was obtained from all participants under one of two institutional review board–approved, HIPAA-compliant protocols. Twelve female patients (age range, 19–54 years; mean age, 41.2 years) and eight normal control subjects (age range, 22–56 years; mean age, 43.2 years) enrolled and completed the study from January 28, 2011, to March 5, 2013. Patients had previous lesions that were Breast Imaging Reporting and Data System 4 and 5 based on mammography and/or ultrasonographic imaging. Contrast-enhanced SWIFT imaging was completed by using a 4-T research MR imaging system. Noncontrast studies were completed in the normal control subjects. One of two sized single-breast SWIFT-compatible transceiver coils was used for nine patients and five controls. Three patients and five control subjects used a SWIFT-compatible dual breast coil. Temporal resolution was 5.9–7.5 seconds. Spatial resolution was 1.00 mm isotropic, with later examinations at 0.67 mm isotropic, and dual breast at 1.00 mm or 0.75 mm isotropic resolution. Results Two nonblinded breast radiologists reported SWIFT image findings of normal breast tissue, benign fibroadenomas (six of six lesions), and malignant lesions (10 of 12 lesions) concordant with other imaging modalities and pathologic reports. Two lesions in two patients were not visualized because of coil field of view. The images yielded by SWIFT showed the presence and extent of known breast lesions. Conclusion The SWIFT technique could become an important addition to breast imaging modalities because it provides high spatial resolution at all points during the dynamic contrast-enhanced examination. © RSNA, 2014


  • Open Access

    Automated tuning of an eight‐channel cardiac transceive array at 7 tesla using piezoelectric actuators

    by Graeme A. Keith, Christopher T. Rodgers, Aaron T. Hess, Carl J. Snyder, J. Thomas Vaughan, Matthew D. Robson

    Purpose: Ultra‐high field (UHF) MR scanning in the body requires novel coil designs due to B1 field inhomogeneities. In the transverse electromagnetic field (TEM) design, maximum B1 transmit power can only be achieved if each individual transmit element is tuned and matched for different coil loads, which requires a considerable amount of valuable scanner time.Methods: An integrated system for autotuning a multichannel parallel transmit (pTx) cardiac TEM array was devised, using piezoelectric actuators, power monitoring equipment and control software. The reproducibility and performance of the system were tested and the power responses of the coil elements were profiled. An automated optimization method was devised and evaluated.Results: The time required to tune an eight‐element pTx cardiac RF array was reduced from a mean of 30 min to less than 10 min with the use of this system.Conclusion: Piezoelectric actuators are an attractive means of tuning RF coil arrays to yield more efficient B1 transmission into the subject. An automated mechanism for tuning these elements provides a practical solution for cardiac imaging at UHF, bringing this technology closer to clinical use. Magn Reson Med 73:2390–2397, 2015. © 2014 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.


  • Gap cycling for SWIFT

    by Curtis A. Corum, Djaudat Idiyatullin, Carl J. Snyder, Michael Garwood

    Purpose: SWIFT (SWeep Imaging with Fourier Transformation) is a non‐Cartesian MRI method with unique features and capabilities. In SWIFT, radiofrequency (RF) excitation and reception are performed nearly simultaneously, by rapidly switching between transmit and receive during a frequency‐swept RF pulse. Because both the transmitted pulse and data acquisition are simultaneously amplitude‐modulated in SWIFT (in contrast to continuous RF excitation and uninterrupted data acquisition in more familiar MRI sequences), crosstalk between different frequency bands occurs in the data. This crosstalk leads to a “bulls‐eye” artifact in SWIFT images. We present a method to cancel this interband crosstalk by cycling the pulse and receive gap positions relative to the un‐gapped pulse shape. We call this strategy “gap cycling.”Theory and Methods: We carry out theoretical analysis, simulation and experiments to characterize the signal chain, resulting artifacts, and their elimination for SWIFT.Results: Theoretical analysis reveals the mechanism for gap‐cycling's effectiveness in canceling interband crosstalk in the received data. We show phantom and in vivo results demonstrating bulls‐eye artifact free images.Conclusion: Gap cycling is an effective method to remove bulls‐eye artifact resulting from interband crosstalk in SWIFT data. Magn Reson Med 73:677–682, 2015. © 2014 Wiley Periodicals, Inc.


  • Stepped Impedance Resonators for High-Field Magnetic Resonance Imaging

    by Can E. Akgun, Lance DelaBarre, Hyoungsuk Yoo, Sung-Min Sohn, Carl J. Snyder, Gregor Adriany, Kamil Ugurbil, Anand Gopinath, J. Thomas Vaughan

    Multi-element volume radio-frequency (RF) coils are an integral aspect of the growing field of high-field magnetic resonance imaging. In these systems, a popular volume coil of choice has become the transverse electromagnetic (TEM) transceiver coil consisting of microstrip resonators. In this paper, to further advance this design approach, a new microstrip resonator strategy in which the transmission line is segmented into alternating impedance sections, referred to as stepped impedance resonators (SIRs), is investigated. Single-element simulation results in free space and in a phantom at 7 T (298 MHz) demonstrate the rationale and feasibility of the SIR design strategy. Simulation and image results at 7 T in a phantom and human head illustrate the improvements in a transmit magnetic field, as well as RF efficiency (transmit magnetic field versus specific absorption rate) when two different SIR designs are incorporated in 8-element volume coil configurations and compared to a volume coil consisting of microstrip elements.


  • Open Access

    Human cardiac 31P magnetic resonance spectroscopy at 7 tesla

    by Christopher T. Rodgers, William T. Clarke, Carl Snyder, J. Thomas Vaughan, Stefan Neubauer, Matthew D. Robson

    Purpose: Phosphorus magnetic resonance spectroscopy (31P‐MRS) affords unique insight into cardiac energetics but has a low intrinsic signal‐to‐noise ratio (SNR) in humans. Theory predicts an increased 31P‐MRS SNR at 7T, offering exciting possibilities to better investigate cardiac metabolism. We therefore compare the performance of human cardiac 31P‐MRS at 7T to 3T, and measure T1s for 31P metabolites at 7T.Methods: Matched 31P‐MRS data were acquired at 3T and 7T, on nine normal volunteers. A novel Look‐Locker CSI acquisition and fitting approach was used to measure T1s on six normal volunteers.Results: T1s in the heart at 7T were: phosphocreatine (PCr) 3.05 ± 0.41s, γ‐ATP 1.82 ± 0.09s, α‐ATP 1.39 ± 0.09s, β‐ATP 1.02 ± 0.17s and 2,3‐DPG (2,3‐diphosphoglycerate) 3.05 ± 0.41s (N = 6). In the field comparison (N = 9), PCr SNR increased 2.8× at 7T relative to 3T, the Cramer‐Ráo uncertainty (CRLB) in PCr concentration decreased 2.4×, the mean CRLB in PCr/ATP decreased 2.7× and the PCr/ATP SD decreased 2×.Conclusion: Cardiac 31P‐MRS at 7T has higher SNR and the spectra can be quantified more precisely than at 3T. Cardiac 31P T1s are shorter at 7T than at 3T. We predict that 7T will become the field strength of choice for cardiac 31P‐MRS. Magn Reson Med 72:304–315, 2014. © 2013 The Authors. Magnetic Resonance in Medicine Published by Wiley Periodicals, Inc. on behalf of International Society of Medicine in Resonance. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited.


  • Open Access

    Automated tuning and matching of a 16-channel TEM transmit-only array used in conjunction with a 32-channel receive-only loop array for MR cardiac imaging at 7 tesla

    by Carl J. Snyder, Lance DelaBarre, J. Thomas Vaughan

    Radiofrequency (RF) coils are antenna-like devices used in magnetic resonance imaging (MRI) to inductively excite and receive the nuclear magnetic resonance (NMR) signal in anatomy. Recently, coil arrays have shown significant advantages over large single channel volume coils at ultra-high magnetic field strengths. However, to maximize the full potential, each individual coil within the array needs to be “tuned and matched” to the anatomy (load) prior to imaging. Tuning and matching can be a tedious and time consuming process, and has been cited as a problem that precludes ultra-high field strength MRI from a becoming a clinical reality. Here, we have developed an electromechanical solution. A 16-channel transmit-only TEM array was designed and fitted with piezoelectric actuators mechanically linked to sliding cylindrical tuning and matching capacitors to automate the tuning and matching process, based on the coil's reflection coefficient.

  • Open Access

    Inversion recovery at 7 T in the human myocardium: Measurement of T1, inversion efficiency and B1+

    by Christopher T. Rodgers, Stefan K. Piechnik, Lance J. DelaBarre, Pierre‐François Van de Moortele, Carl J. Snyder, Stefan Neubauer, Matthew D. Robson, J. Thomas Vaughan

    At clinical MRI field strengths (1.5 and 3 T), quantitative maps of the longitudinal relaxation time T1 of the myocardium reveal diseased tissue without requiring contrast agents. Cardiac T1 maps can be measured by Look‐Locker inversion recovery sequences such as ShMOLLI at 1.5 and 3 T. Cardiovascular MRI at a field strength of 7 T has recently become feasible, but doubts have remained as to whether magnetization inversion is possible in the heart due to subject heating and technical limitations. This work extends the repertoire of 7 T cardiovascular MRI by implementing an adiabatic inversion pulse optimized for use in the heart at 7 T. A “ShMOLLI+IE” adaptation of the ShMOLLI pulse sequence has been introduced together with new postprocessing that accounts for the possibility of incomplete magnetization inversion. These methods were validated in phantoms and then used in a study of six healthy volunteers to determine the degree of magnetization inversion and the T1 of normal myocardium at 7 T within a 22‐heartbeat breathhold. Using a scanner with 16 × 1 kW radiofrequency outputs, inversion efficiencies ranging from −0.79 to −0.83 (intrasegment means; perfect 180° would give −1) were attainable across the myocardium. The myocardial T1 was 1925 ± 48 ms (mean ± standard deviation). Magn Reson Med, 70:1038–1046, 2013.


  • Open Access

    Comparison between eight‐ and sixteen‐channel TEM transceive arrays for body imaging at 7 T

    by C. J. Snyder, L. DelaBarre, S. Moeller, J. Tian, C. Akgun, P.‐F. Van de Moortele, P. J. Bolan, K. Ugurbil, J. T. Vaughan, G. J. Metzger

    Eight‐ and sixteen‐channel transceive stripline/TEM body arrays were compared at 7 T (297 MHz) both in simulation and experiment. Despite previous demonstrations of similar arrays for use in body applications, a quantitative comparison of the two configurations has not been undertaken to date. Results were obtained on a male pelvis for assessing transmit, signal to noise ratio, and parallel imaging performance and to evaluate local power deposition versus transmit B1 (B1+). All measurements and simulations were conducted after performing local B1+ phase shimming in the region of the prostate. Despite the additional challenges of decoupling immediately adjacent coils, the sixteen‐channel array demonstrated improved or nearly equivalent performance to the eight‐channel array based on the evaluation criteria. Experimentally, transmit performance and signal to noise ratio were 22% higher for the sixteen‐channel array while significantly increased reduction factors were achievable in the left–right direction for parallel imaging. Finite difference time domain simulations demonstrated similar results with respect to transmit and parallel imaging performance, however, a higher transmit efficiency advantage of 33% was predicted. Simulations at both 3 and 7 T verified the expected parallel imaging improvements with increasing field strength and showed that, for a specific B1+ shimming strategy used, the sixteen‐channel array exhibited lower local and global specific absorption rate for a given B1+. Magn Reson Med, 2011.


  • 7 Tesla (T) human cardiovascular magnetic resonance imaging using FLASH and SSFP to assess cardiac function: validation against 1.5 T and 3 T.

    by J. J. Suttie, L. DelaBarre, A. Pitcher, P. F. van de Moortele, S. Dass, C. J. Snyder, J. M. Francis, G. J. Metzger, P. Weale, K. Ugurbil, et al.

    We report the first comparison of cardiovascular magnetic resonance imaging (CMR) at 1.5 T, 3 T and 7 T field strengths using steady state free precession (SSFP) and fast low angle shot (FLASH) cine sequences. Cardiac volumes and mass measurements were assessed for feasibility, reproducibility and validity at each given field strength using FLASH and SSFP sequences. Ten healthy volunteers underwent retrospectively electrocardiogram (ECG) gated CMR at 1.5 T, 3 T and 7 T using FLASH and SSFP sequences. B1 and B0 shimming and frequency scouts were used to optimise image quality. Cardiac volume and mass measurements were not significantly affected by field strength when using the same imaging sequence (P > 0.05 for all parameters at 1.5 T, 3 T and 7 T). SSFP imaging returned larger end diastolic and end systolic volumes and smaller left ventricular masses than FLASH imaging at 7 T, and at the lower field strengths (P < 0.05 for each parameter). However, univariate general linear model analysis with fixed effects for sequence and field strengths found an interaction between imaging sequence and field strength (P = 0.03), with a smaller difference in volumes and mass measurements between SSFP and FLASH imaging at 7 T than 1.5 T and 3 T. SSFP and FLASH cine imaging at 7 T is technically feasible and provides valid assessment of cardiac volumes and mass compared with CMR imaging at 1.5 T and 3 T field strengths. Copyright © 2011 John Wiley & Sons, Ltd.