SASam Ali

Sam Ali

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sam Ali has a total of 124 co-authors. Here are the top co-authors by number of shared publications:

  • Aris T. Papageorghiou

    Nuffield Department of Women’s and Reproductive Health, University of Oxford, Oxford, UK

    8 shared publications
  • Josaphat Byamugisha

    Department of Obstetrics and Gynecology, Makerere University Hospital, Makerere University, Kampala, Uganda

    5 shared publications
  • Josaphat Byamugisha

    Department of Obstetrics and Gynaecology, School of Medicine, Makerere University College of Health Sciences, Kampala, Uganda

    4 shared publications
  • Marcus Johannes Rijken

    Faculty Medicine, Utrecht University, Utrecht, the Netherlands; Department of Gynaecologic oncology, Dutch Cancer Institute, Amsterdam, the Netherlands; Julius Global Health, The Julius Center for Health Sciences and Primary Care, University medical Centre, Utrecht University, Utrecht, the Netherlands

    4 shared publications
  • Aris T. Papageorghiou

    Nuffield Department of Women’s and Reproductive Health, University of Oxford, Oxford, UK

    3 shared publications
  • Kerstin Klipstein-Grobusch

    Julius Global Health, Department of Global Public Health and Bioethics, Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands

    3 shared publications

Latest Publications

  • Open Access

    Community-Delivered Antenatal Care to Address Access Barriers: Perspectives of Women and Healthcare Workers

    by Olive Kabajaasi, Winfred Nakato Nansozi, Ashley Younger, Judith Kiconco, Shanitah Nankya, Daniel Lukakamwa, Assen Kamwesigye, Ibrahim Bwaga, Andrew Odur, Rose Mukisa-Bisoborwa, et al.

    Stillbirth remains a major public health concern, particularly in resource-constrained settings. Barriers to timely, high-quality antenatal care may delay the recognition and management of pregnancy complications. We explored the perspectives of women, Village Health Team (VHT) members and healthcare workers on community-delivered approaches to improve pregnancy care, in particular prevention of stillbirth in Uganda. An exploratory qualitative study was conducted at four referral hospitals in Uganda. Data were collected through focus group discussions, in-depth interviews, and key informants’ interviews with women, Village Health Team members and healthcare workers. Audio-recordings were transcribed verbatim and translated into English where required. Data were analysed thematically using an iteratively developed codebook and NVivo software. In total, 56 participants took part, comprising women (n=27), Village Health Team members (n=11) and frontline healthcare workers (n=18). Participants highlighted the need for the adoption of simple and user-friendly wearable pregnancy monitoring tools for self-monitoring of early warning signs. Health education sessions focused on identifying early warning signs of pregnancy complications highlighted, emphasizing the importance of empowering women with information to seek care early through digital platforms. Limited follow-up support was also a critical concern, with the majority of the women advocating for better emotional and psychological care after a stillbirth, both at a facility and at home. Participants viewed community-delivered antenatal care as an acceptable approach to reducing access barriers. Implementation would require trained personnel, quality-assured tools, clear referral pathways and integration with facility-based care. Structured communication and psychosocial support after stillbirth were also identified as priorities. These findings should inform co-design and prospective evaluation of community-delivered models.

  • Open Access

    Reducing stillbirth in high burden settings using biomarkers and ultrasound technologies: protocol for the multi-centre prospective iTECH cohort study

    by Sam Ali, Winfred Nakato, Josephine Tumuhamye, Sheila Nabweyambo, Obondo J. Sande, Rose Mukisa Bisoborwa, Wessel Ganzevoort, Sanne J Gordijn, Marcus J Rijken, Kerstin Klipstein Grobusch, et al.

    Introduction Stillbirth prevention requires reliable detection of potential causes for timely interventions. Currently, there is no effective screening strategy to identify fetuses at risk of stillbirth. Prognostic models have been proposed as a potential solution, but there is a shortage of robust, clinically applicable models in low- and middle-income countries. Early birth is frequently initiated without proper risk stratification, leading to increased neonatal and infant morbidity and mortality. This study aims to develop and validate multi modal multivariable prediction models for stillbirth and pathologies that lead to stillbirth (preeclampsia & fetal growth restriction) using widely accessible and cost-effective markers. Stakeholder perspectives will also be assessed. Methods and analysis This multi-center prospective cohort study is running in four high volume regional referral hospitals in Uganda: Kawempe, Hoima, Lira, and Mbale. We will enroll at least 6,075 pregnant women attending routine antenatal care (ANC), above 13 years of age, and greater than or equal to11 weeks of gestation. Data and biological samples will be collected at 11-23 weeks, 35-37 weeks and at birth in all women. In a subset of women, additional measurements will be obtained between 24-34 weeks and 38-42 weeks to allow for spread of the data across the full spectrum of pregnancy. This data will enable us to investigate the physiological changes with gestational development in healthy or unhealthy pregnancies, to guide future monitoring and management of women and establishment of reference values for novel markers. The placenta will be collected for histopathological analysis in women diagnosed with intrauterine fetal demise at greater than or equal to 20 weeks of gestation, stillbirth nearmiss and their corresponding controls. Data on socio-demographics, obstetric history, current pregnancy conditions, and tests such as maternal hemodynamics, ultrasound, and biochemical markers will be collected from each participant, and used to develop regression and machine learning prediction models. Models will be validated and evaluated by comparing their calibration plots, precision and recall, F1 scores and accuracy, aiming for less complexity and reliable predictions. Emerging models will be translated into software as a medical device (SAMD), while taking into account user experiences, regulatory requirements, data pipelines in clinical workflows and user-friendly interfaces that facilitate access and the interpretation of outputs, to allow for seamless integration into existing electronic health information systems and decision support tools. To assess stakeholder perceptions, we will employ an exploratory qualitative component using focus group discussions, semi-structured and key informant interviews. The sample will include 81 purposively selected women and their partners who use maternity care services, local leaders and healthcare providers in and out of the four hospitals implementing iTECH in Uganda. Qualitative data will be audio recorded, transcribed verbatim and thematic analysis performed using Nvivo 12.


  • Including pregnant and breastfeeding women in clinical trials

    by Sam Ali, Shakira Babirye, Fosca Tumushabe, Aris T Papageorghiou

    Studies must be adapted to fill the evidence gaps

  • Automated Placental ROI Selection for Quantitative Ultrasound Analysis Using Boundary-Aware Thresholding

    by William Hempstead, Hamid Moradi, Atugonza Gamukama, Bashir Ssuna, Winfred Nakato Nansozi, Eunice Namwase, Nabafu Flavia, Aris T. Papageorghiou, Sam Ali, Robert N. Rohling, et al.

    Quantitative ultrasound (QUS) analysis of placental tissue holds significant promise for evaluating pregnancy health and detecting placental pathologies. However, widespread clinical adoption of QUS is limited by the need for manual selection of a proper region of interest (ROI) for the calculation, which increases the analysis time and introduces operator variability. This study presents an automated ROI determination method that uses deep learning segmentation directly on minimally processed raw RF data (along with corresponding B-mode data for comparison) to replace manual ROI selection in placental QUS analysis while also taking advantage of the model’s internal confidence thresholds to reduce inclusion of non-placental tissue near ambiguous tissue boundaries. Using a diverse, multi-national data set of 1084 annotated ultrasound images, the proposed automated ROI model achieved a mean Dice similarity coefficient (DSC) above 0.8 for confidence thresholds between 50% to 75%. At thresholds above 75%, precision improved, but both DSC and recall performance declined, and the amount of placental tissue identified for an accurate QUS calculation fell below the minimum required ROI size. Bland-Altman analysis showed tight agreement between the QUS values derived from ground truth ROIs and automated ROIs up to a 75% confidence threshold, but reduced agreement at higher thresholds, consistent with inferior performance obtained for placental pixel area below the minimum. These findings demonstrate both the feasibility of automated ROI determination and the need for careful consideration of the confidence thresholds when assessing model performance.


  • Effect of supine or semi-recumbent positions on arterial stiffness among pregnant women

    by Sam Ali, Brendah Nambozo, Evalyne Tusiimirwe, Irene Ajenga, Eliot T. Kanyesigye, Jillian Awati, Adam Eminai, Helen Perry, Josaphat Byamugisha, Aris T. Papageorghiou

  • Open Access

    Predictive accuracy of ophthalmic artery Doppler for pre-eclampsia: a systematic review

    by Joseph Arkorful, Joyce Linda Browne, Kwame Adu-Bonsaffoh, Sam Ali, Emmanuel Srofenyoh, Kitty M W Bloemenkamp

    Objectives: This systematic review investigated available evidence on the stand-alone and incremental predictive performance of ophthalmic artery Doppler (OAD) for pre-eclampsia. Design: Systematic review. Data sources: We conducted a literature search from PubMed (Medline), the Cochrane CENTRAL, EMBASE and Scopus from inception to 8 April 2025. Eligibility criteria: Studies eligible for inclusion were prospective or retrospective cohort studies, case-control studies or randomised controlled trials that reported on the predictive performance of OAD for pre-eclampsia in singleton pregnancies; and conducted in either high-income country (HIC) or low- and middle-income country (LMIC). Data extraction and synthesis: Two reviewers independently screened and assessed articles for inclusion. One reviewer then extracted data using a standardised data extraction sheet, and any uncertainties were discussed with a second reviewer. The Prediction model Risk of Bias Assessment Tool was used for quality and risk of bias assessment. Findings were summarised and reported according to the Preferred Reporting Items for Systematic Review and Meta-Analyses statement and synthesised qualitatively. Results: We identified and included 11 observational studies (3 from HIC and 8 from LMICs) with a total of 12 150 singleton pregnancies, of which 517 (4.3%) were complicated by pre-eclampsia at end of follow-up. The included studies were of varied quality, with three at low risk of bias, four at unclear risk and four at high risk. No interventional study was identified. Three studies (27.3%) recruited high-risk pregnancies (defined according to the American College of Obstetricians and Gynecologists (ACOG) criteria as one or more of the following: chronic hypertension, personal or family history of pre-eclampsia, early (≤18 years) or late (≥40 years) first pregnancy, primipaternity, chronic kidney disease, increased body mass index >30 kg/m 2 , presence of diabetes mellitus prior to pregnancy, autoimmune disease and thrombophilia), while eight studies (72.7%) recruited undetermined risk pregnancies. Stand-alone performance of OAD (interpreted by area under the receiver operating curve at 95% CI) showed that in the first trimester, the peak systolic velocity (PSV) ratio demonstrated very good predictive ability (0.97, 95% CI 0.92 to 1.0) (n=1 study), and the second PSV (PSV 2 ) demonstrated very good predictive ability (0.91, 95% CI 0.82 to 0.99) (n=1 study). Also, PSV 2 demonstrated fair predictive ability (0.61, 95% CI 0.42 to 0.79; and 0.53, 95% CI 0.40 to 0.66) for early and late pre-eclampsia, respectively (n=1 study). In the second trimester, the PSV ratio demonstrated very good predictive ability (0.88, 95% CI 0.84 to 0.91) (n=1 study), and PSV 2 demonstrated good predictive ability (0.73, 95% CI 0.66 to 0.81; and 0.76, 95% CI 0.71 to 0.81) for pre-eclampsia (n=2 studies). In the third trimester, the PSV ratio demonstrated good predictive ability (0.82, 95% CI 0.73 to 0.89; and 0.77, 95% CI 0.71 to 0.82) for preterm and term pre-eclampsia, respectively (n=1 study). Also, PSV 2 demonstrated good predictive ability 0.70 (0.57 to 0.84) (n=1 study). Subsequently, in the second trimester, PSV ratio demonstrated better incremental predictive performance than uterine artery pulsatility index for preterm pre-eclampsia, when added to maternal factors and mean arterial pressure (MAP) (56.1%–80.2% vs 56.1%–74.8% detection rate (DR) at 10% FPR) (n=1 study). Also in the third trimester, adding PSV ratio to maternal factors and MAP was superior to soluble fms-like tyrosine kinase-1/placental growth factor ratio in predicting pre-eclampsia at 2 are potentially useful ultrasound markers for pre-eclampsia prediction. Particularly in the second trimester, adding PSV ratio to maternal factors and MAP significantly improved the prediction of preterm pre-eclampsia. Given the burden of early and preterm pre-eclampsia in low-resource settings, OAD appears promising for pre-eclampsia screening in these settings where serum biomarkers may be expensive and inaccessible, and where uterine artery Doppler may not be technically feasible. However, the extent to which this novel marker is implemented in routine antenatal care should be guided by larger and sufficiently powered validation studies. PROSPERO registration number: CRD42022324569.


  • Open Access

    Standardization and quality control of the introduction of a noninvasive cardiac output monitor for pregnancy measurements in a low‐ and middle‐income country

    by Helen Perry, Evalyne Tusiimirwe, Allen Nakayenga, Wessel Ganzevoort, Josephine Tumuhamye, Winfred Nakato, Josaphat Byamugisha, Kelvin Mbote, Aris T. Papageorghiou, Sam Ali, et al.

    Introduction: There is increasing awareness of the role of the maternal cardiovascular system in complicated pregnancies. Despite the high disease burden, noninvasive cardiac output monitors have not been used extensively in low‐ and middle‐income countries. The aim of this study was to evaluate the quality control of the use of the ultrasonic cardiac output monitor (USCOM) 1A® in a LMIC (low an middle income country).Material and Methods: This was a quality assessment study of the introduction of the USCOM 1A® to measure maternal hemodynamic indices. Inter‐observer agreement was assessed across all four study sites by intraclass correlation coefficient. Quality control was assessed using pre‐defined acceptability criteria, rated by 2 independent scorers.Results: On average, nurses or midwives needed to obtain 30.4 (range 24–36) Doppler waveform recordings to be deemed competent to undertake USCOM 1A® measurements. There was very good inter‐observer agreement across all 4 sites (intraclass correlation coefficient 0.86–0.93, all p < 0.001). A total of 138 images were randomly selected for quality review. Overall, 79 (89.8%) images were considered acceptable by both scorers; 4 (6.9%) were considered unacceptable by both scorers; and there was disagreement in 5 (5.7%) cases. Overall agreement was 94.3%. Agreement as assessed by Fleiss' kappa, was moderate (0.585 [95% CI 0.376–0.794], p < 0.001).Conclusions: Using a robust learning package and clearly defined image criteria, a novel cardiac‐output monitor can be successfully introduced into low‐ and middle‐income countries, in the context of research. Ongoing quality control measures are imperative to maintain the integrity of planned future studies using USCOM 1A®.

  • Open Access

    Relationship of maternal ophthalmic artery Doppler with uterine artery Doppler, hemodynamic indices and gestational age: prospective MATERA study

    by S. Ali, D. C. Mukasa, D. Lukakamwa, A. Nakayenga, P. Namagero, J. Biira, J. Byamugisha, A. T. Papageorghiou

    Objectives: To examine the relationship of ophthalmic artery (OA) Doppler indices with uterine artery (UtA) Doppler indices, selected maternal hemodynamic parameters and gestational age, and to evaluate the intraobserver reproducibility of OA Doppler indices.Methods: This was a prospective cohort study of women recruited between 11 + 0 and 23 + 6 weeks' gestation using a stratified and random sampling approach to ensure adequate distribution across the gestational‐age range. OA pulsatility index (PI), first peak systolic velocity (PSV1), second peak systolic velocity (PSV2) and peak systolic velocity ratio (PSV ratio), calculated as PSV2/PSV1, were measured twice in each eye by the same observer. UtA‐PI was also measured twice on each side by the same observer. Maternal hemodynamic assessment was undertaken using an ultrasonic cardiac output monitor (USCOM 1A). Pearson's and Spearman's rank correlation coefficients were used to assess the correlations between variables, and Bland–Altman plots were used to evaluate the intraobserver reproducibility of OA Doppler indices.Results: Of 194 women invited to participate in the study, 169 were eligible for inclusion, of whom 16 were excluded following an obstetric ultrasound scan and a further three owing to inadequate or incomplete OA or UtA Doppler assessment, leaving 150 women in the final analysis. Log UtA‐PI had a weak correlation with both OA‐PI (r = –0.19 (95% CI, –0.34 to –0.03), P = 0.021) and OA‐PSV ratio (r = 0.31 (95% CI, 0.15–0.45), P < 0.001). The correlation between gestational age and OA‐PI was non‐significant (r = 0.14 (95% CI, –0.03 to 0.29), P = 0.097), and that between gestational age and OA‐PSV ratio was weak (r = –0.23 (95% CI, –0.38 to –0.07), P = 0.004), as opposed to the strong correlation between gestational age and UtA‐PI (r = –0.68 (95% CI, –0.76 to –0.58), P < 0.001). No strong correlations were observed between OA‐PI or OA‐PSV ratio and maternal hemodynamic indices. The correlations were unaltered by adjustment for maternal age and body mass index. The intraobserver reproducibility of OA‐PI and OA‐PSV ratio in the same eye was high. The correlation between the right and left eyes was moderate for OA‐PI (r = 0.63 (95% CI, 0.53–0.72), P < 0.001) and strong for OA‐PSV ratio (r = 0.81 (95% CI, 0.75–0.86), P < 0.001).Conclusions: OA‐PI and OA‐PSV ratio had a weak or no correlation with UtA‐PI and maternal hemodynamic parameters, meaning that they can be used as independent predictors for pre‐eclampsia. Gestational age had no clinically relevant effect on OA‐PI and OA‐PSV ratio, suggesting that these indices could be measured without adjustment at any time between 11 and 23 weeks' gestation. OA Doppler indices had high intraobserver reproducibility and were strongly correlated between the right and left eyes. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


  • Near‐miss criteria for stillbirth in global research: the ‘In Utero’ consensus

    by S. J. Gordijn, A. T. Papageorghiou, A. L. David, S. Ali, W. Ganzevoort


  • Open Access

    Establishing Surrogate markers by Consensus for Antepartum and Intrapartum Stillbirth: The In-utero Consensus for Alternative outcomes in Research on Stillbirth (ICARES) project

    by Sanne Gordijn, Aris Papageorghiou, Anna David, Sam Ali, Wessel Ganzevoort

    Intervention bias refers to a systematic difference in management or variable exposure among subjects in studies, which can significantly influence outcomes.